11/8/2000 1 Sensitivity of Spectroscopic Scatterometry: Sub-100nm Technology SFR Workshop November 8, 2000 Ralph Foong, Costas Spanos Berkeley, CA 2001.

Slides:



Advertisements
Similar presentations
Spectroscopic Ellipsometry University of Texas at El Paso Lynn Santiago Dr. Elizabeth Gardner Chem 5369.
Advertisements

RMS VISION SYSTEMS Innovative Solutions for the Semiconductor Industry Application Note: CD Measurement for FET Features NGS 3500 Advanced Metrology System.
Lecture 21 QCM and Ellipsometry
Selectivity, Sensitivity, Signal to Noise, Detection Limit
Microwindow Selection for the MIPAS Reduced Resolution Mode INTRODUCTION Microwindows are the small subsets of the complete MIPAS spectrum which are used.
PERFORMANCE OF THE DELPHI REFRACTOMETER IN MONITORING THE RICH RADIATORS A. Filippas 1, E. Fokitis 1, S. Maltezos 1, K. Patrinos 1, and M. Davenport 2.
Toward Performance-Driven Reduction of the Cost of RET-Based Lithography Control Dennis Sylvester Jie Yang (Univ. of Michigan,
Woodpile Structure Fabrication Chris McGuinness July 8, 2009 Workshop on Novel Concepts for Linear Accelerators and Colliders Working Group 2: Dielectric.
Spontaneous Radiation at LCLS Sven Reiche UCLA - 09/22/04 Sven Reiche UCLA - 09/22/04.
Chapter 5 Signals and Noise  Signal carries information about the analyte that is of interest to us.  Noise is made up of extraneous information that.
FMS review, Sep FPD/FMS: calibrations and offline reconstruction Measurements of inclusive  0 production Reconstruction algorithm - clustering.
Small Feature Reproducibility A Focus on Photolithography
Solvency Testing Model SD-CNSF México October, 2002.
Virtual Metrology to Measure Mass Loss at Deep Trench Processes
Infrasound detector for Apatity group Asming V.E., Kola Regional Seismological Center, Apatity, Russia.
Analytical capability of neutron sensor incorporated into UNCOSS ROV Project meeting and workshop: Dubrovnik 30th November and 01st December 2011.
Analytical considerations
Measurement of through-going particle momentum by means of Multiple Scattering with the T600 TPC Talk given by Antonio Jesús Melgarejo (Universidad de.
A. Blondel, M.Campanelli, M.Fechner Energy measurement in quasi-elastics Unfolding detector and physics effects Alain Blondel Mario Campanelli Maximilien.
Rationale / value of using statistics statistics is a powerful tool to objectively compare experimental data uncover relationships among variables experience.
SRRTTF Technical Activities Where We’ve Been, Where We’re Going Dave Dilks Spokane River Regional Toxics Task Force Workshop January 13,
The aerogel radiator: optical characterization and performances L.L. Pappalardo INFN - University of Ferrara 1 CLAS12 RICH Review – JLab - September 5-6.
UV-Vis Absorption Spectroscopy
Digital Imaging. Digital image - definition Image = “a two-dimensional function, f(x,y), where x and y are spatial coordinates, and the amplitude of f.
1 A Bayesian statistical method for particle identification in shower counters IX International Workshop on Advanced Computing and Analysis Techniques.
Calibration software for the HADES electromagnetic calorimeter (EMC) Dimitar Mihaylov Excellence Cluster ‘Universe’, TU Munich HADES collaboration meeting.
Quality Assurance How do you know your results are correct? How confident are you?
Divergent Illumination Optical Testing Device M. Fried 1, Z. Horváth 2, G. Juhász 1, O. Polgár 1, T. Mosoni 1, P. Petrik 1 1 Research Institute for Technical.
Frequency Scanned Interferometer Demonstration System Tim Blass, Jason Deibel, Sven Nyberg, Keith Riles, Haijun Yang University of Michigan, Ann Arbor.
C. Fischer – LHC Instrumentation Review – 19-20/11/2001 Gas Monitors for Transverse Distribution Studies in the LHC LHC Instrumentation Review Workshop.
Sources of noise in instrumental analysis
11/8/ Microplasma Optical Emission Spectrometer (MOES) on a chip SFR Workshop November 8, 2000 Michiel Krüger, David Hsu, Scott Eitapence, K. Poolla,
Trilinear Gauge Couplings at TESLA Photon Collider Ivanka Božović - Jelisavčić & Klaus Mönig DESY/Zeuthen.
Fast Electron Temperature Scaling and Conversion Efficiency Measurements using a Bremsstrahlung Spectrometer Brad Westover US-Japan Workshop San Diego,
Melissa, Connie, Melissa, Jieyi, Ambereen, Dorothy King Edward VI High school for Girls.
Analysis of Nonlinearity Correction for CrIS SDR April 25, 2012 Chunming Wang NGAS Comparisons Between V32 and V33 Engineering Packets.
Optical Receivers Theory and Operation
11/8/99 1 Autonomous On-Wafer Sensor Arrays SFR Workshop November 8, 1999 Mason Freed, Kameshwar Poolla, and Costas Spanos Berkeley, CA This project involves.
Gordana Milutinovic-Dumbelovic Vinca Institute of Nuclear Sciences, Belgrade Ivanka Bozovic-Jelisavcic, Strahinja Lukic, Mila Pandurovic Branching ratio.
5/24/ DUV ASML 5500/90 Stepper for Novel Lithography SFR Workshop May 24, 2001 SFR:Andrew R. Neureuther, Mosong Cheng, Haolin Zhang SRC/DARPA Garth.
5/24/ Towards a Complete Plasma Diagnostic System SFR Workshop May 24, 2001 Dong Wu Zhao, Costas Spanos Berkeley, CA 2001 GOAL: Install automated.
10 March 2016Materi ke-3 Lecture 3 Statistical Process Control Using Control Charts.
8:30 – 9:00 Research and Educational Objectives / Spanos 9:00 – 9:50 Plasma, Diffusion / Graves, Lieberman, Cheung, Haller 9:50 – 10:10 break 10:10 – 11:00.
H. Matis, S. Hedges, M. Placidi, A. Ratti, W. Turner [+several students] (LBNL) R. Miyamoto (now at ESSS) H. Matis - LARP CM18 - May 8, Fluka Modeling.
Date of download: 6/3/2016 Copyright © 2016 SPIE. All rights reserved. (a) The working principle of the tilt-beam CD-SEM. The feature of interest is imaged.
TAUCHI PHILOSOPHY SUBMITTED BY: RAKESH KUMAR ME
A. Ealet Berkeley, december Spectrograph calibration Determination of specifications Calibration strategy Note in
Date of download: 7/7/2016 Copyright © 2016 SPIE. All rights reserved. Illumination geometry for vertical and horizontal lines, respectively. The illumination.
July 11, 2016 Run-to-Run Control of Linewidth and Overlay in Semiconductor Manufacturing Christopher Allen Bode Dr. Thomas F. Edgar, Advisor University.
Date of download: 9/17/2016 Copyright © 2016 SPIE. All rights reserved. (a) Schematic definition of line edge roughness (LER) and line width roughness.
Automated Characterization of Optical Image Quality
Proposing Data Mining for Plasma Diagnosis
Laser Physics & Nonlinear Optics
3rd Annual SFR Workshop & Review, May 24, 2001
BAHIRDAR UNIVERSTY COLLEGE OF SCIENCE DEPARTMENT :MATERIAL SCIENCE AND ENGINNERING PRESENTETON ON: ELLIPSOMETRY INSTRUMENT PREPEARED BY :ZELALEM GETU AMSALE.
Sensitivity of Spectroscopic Scatterometry: Sub-100nm Technology
Lithography Diagnostics Based on Empirical Modeling
Enabling Full Profile CMP Metrology and Modeling
Autonomous temperature sensor for bake plate calibration
Profile Extraction with Specular Spectroscopic Scatterometry
Process Recipe Optimization using Calibrated Simulation Engine
Plasma Chamber Spectrographic Data Acquisition and Archival
Kostas Adam, Andrew Neureuther
Resist Resolution Enhancement and Line-end Shortening Simulation
Acoustic Emission Sensing for Chemical Mechanical Polishing (CMP)
Resist modeling, Simulation and Line-End Shortening effects
Junwei Bao, Costas Spanos
Effects of LER on MOSFET Electrical Behavior
Full Profile CMP Metrology
Fitting Systematics Sensitivity of overall fitting to ratio fit
Presentation transcript:

11/8/ Sensitivity of Spectroscopic Scatterometry: Sub-100nm Technology SFR Workshop November 8, 2000 Ralph Foong, Costas Spanos Berkeley, CA 2001 GOAL: To fully characterize the capabilities of scatterometry in fulfilling the metrology needs of the 100nm technology node.

11/8/ Motivation Capabilities of scatterometry and required equipment specifications need to be formalized for 100nm metrology. –Commercial ellipsometers have been identified as being able to perform spectroscopic scatterometry. Hence, the focus of this study is on these equipment. –Precision of current generation commercial ellipsometers in measuring profiles consistent with 100nm technology node has to be confirmed. Scalability of scatterometry towards 70nm and 50nm metrology has to be explored. –Minimum commercial ellipsometer specifications necessary to successfully implement 70nm and 50nm metrology need to be determined.

11/8/ Overall Framework of Sensitivity Analysis Commercial Equipment Analysis Profile Parameters Simulations for variation in parameter X [X (-),X (Nominal), X (+) ] Cos  Lambda Tan  Lambda Determine Noise Contributions Tan , Cos  Noise Spectrum Are Variations Detectable? No Yes EM Response Variations Which part of the spectrum contains the most information?

11/8/ Methodology Electromagnetic simulations are conducted for small changes in profile parameters to measure variations in EM response. Noise analysis of commercial ellipsometers is carried out to determine detectability of EM response variations. d(Beam Divergence) d(I Source ) d(  Polarizer ) d(  Analyzer ) d(I Detector ) Sample PR ARC Poly-Si Rounding Slope Angle Height CD Footing Si

11/8/ Signal-to-Noise Ratio for SOPRA Ellipsometer Signal averaged over 30 measurements Noise represents 1  standard deviation for each wavelength Empirical formula for signal-to- noise ratio: Noise = 0.412(Intensity) (R 2 Value = 0.937) Intensity fluctuation is the main contributor of measurement noise in ellipsometers. Monte-Carlo simulations incorporating intensity fluctuations are used to determine the final distributions of Tan  and Cos  The ‘Minimum Detectable Variation’ lines represent the sum of the 3  errors of each of the 2 profiles measured to obtain the variation. The graphs demonstrate a trend toward significant information contained in a narrow band in the lower wavelength spectrum.

11/8/ nm Technology Simulations Undetectable (Below yellow line) Detectable (Above yellow line) Undetectable (Below yellow line) 100nm Dense Lines (ASIC) 65nm Isolated Lines (MPU) spectrum of information content

11/8/ nm Technology Simulations 70nm Dense Lines (ASIC) 45nm Isolated Lines (MPU) Detectable (Above yellow line) Undetectable (Below yellow line)

11/8/ nm Technology Simulations 50nm Dense Lines (ASIC) 30nm Isolated Lines (MPU) Detectable (Above yellow line) Undetectable (Below yellow line)

11/8/ & 2003 Goals Study the feasibility of building 100nm capable profile extraction using small footprint, in-line spectroscopic ellipsometry, by 9/30/2002 Implement lithography controller that merges full profile in- line information with available metrology, by 9/30/2003 Profile Diagnostics DUV Photolithography PR Deposition, Focus, Exposure, Bake Time, Development Time, etc Process Flow In-Line Scatterometry Process Flow Wafers Feedback Control Loop