Grounding Studies Metal box sensor SVX4/hybrid Analog cable GND(20W)

Slides:



Advertisements
Similar presentations
Richard J. Mohr President, R. J. Mohr Associates, Inc.
Advertisements

F. Formenti - ALICE forum 16/03/ Contacted some teams for system GND discussions: cases analyzed are presented here Planned to continue with others.
M.PEGORARO Grounding Workshop 24th Jan 08 DT GROUNDING & SHIELDING Presented by A. BENVENUTI.
Layer 0 Grounding Requirement in terms of noise performance Grounding/Shielding studies with L0 prototype Summary Kazu Hanagaki / Fermilab.
EE 587 SoC Design & Test Partha Pande School of EECS Washington State University
Grounding and Testing L0 (L1) --- noise studies --- Kazu Hanagaki, Sara Lager, Gustavo Otero Introduction of noise issue What is going on the other side.
Here’s a partial schematic we’ll use to illustrate the advantage of a ground plane. The idea is that an output pin on the microprocessor is driving an.
1Daya Bay RPC HV FDR 6/17/2008 RPC HV cable pick-up noise issue C. Lu, Princeton University (6/17/2008)
Nasty Realities EECS 150 – Lab6 Spring 2001 By Steve Fang.
EELE 461/561 – Digital System Design Module #6 Page 1 EELE 461/561 – Digital System Design Module #6 – Differential Signaling Topics 1.Differential and.
The maximum current flows when |X C |
November Vertex 2002 Kazu Hanagaki1 Layer 0 in D0 Silicon Tracker for run2b Kazu Hanagaki / Fermilab for D0 run2b Silicon Tracker group Motivation.
CMPE 118 MECHATRONICS Noise Isolation Keeping the Gremlins Out.
Vertex2002, Kailua-Kona, HI 11/07/02 B. Quinn1 Carbon Fiber Grounding Issues in the DØ Run IIb Silicon Detector Design Breese Quinn Marvin Johnson, Mike.
1 Module and stave interconnect Rev. sept. 29/08.
EMC review for Belle II (Grounding & shielding plans) Sub-systems ( XXXXX)
Low Noise Detector Design
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
Analog Cable Status Basic design fixed --- the latest cable has good quality. (report by Frank) Capacitance for single cable ~0.35pF/cm --- both new and.
Experimental Area Meeting V. Bobillier1 Good connection to earth (in many points) of every metallic parts to be installed in the cavern is very.
VELO upgrade electronics – HYBRIDS Tony Smith University of Liverpool.
PROFIBUS wiring/installation can be done with:
SVX4 chip 4 SVX4 chips hybrid 4 chips hybridSilicon sensors Front side Back side Hybrid data with calibration charge injection for some channels IEEE Nuclear.
PCB Layout Introduction
17/06/2010UK Valencia RAL Petals and Staves Meeting 1 DC-DC for Stave Bus Tapes Roy Wastie Oxford University.
Chiho Wang ATLAS TRT Duke University CERN, Feb Fuse Box Status Chiho Wang Duke University.
Modelling of TPM noise problems Greg, following discussions and measurements with David and Senerath.
VELO upgrade Front-end ECS LHCb upgrade electronics meeting 12 April 2012 Martin van Beuzekom on behalf of the VELO upgrade group Some thoughts, nothing.
1 Module and stave interconnect Rev. sept. 29/08.
PCB Layout Introduction
Transmission Lines No. 1  Seattle Pacific University Transmission Lines Kevin Bolding Electrical Engineering Seattle Pacific University.
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Third Edition, by Allan R. Hambley, ©2005 Pearson Education, Inc. Chapter 9 Computer-Based Instrumentation.
IPC Power Distribution Considerations A predominately important factor that should be considered in the design of a printed board is power distribution.
PXL Cable Options LG 1HFT Hardware Meeting 02/11/2010.
W. Karpinski, Nov CMS Electronics week CMS Microstrip Tracker grounding & shielding of the CMS Tracker R. Hammarstrom (CERN EP/CMT) & W. Karpinski.
The LHCb Outer Tracker Front End, what does it look like and what is the status Talk for the LHCb Electronics Working Group /TS A Collaboration.
07 - Winter 2005 ECE ECE 766 Computer Interfacing and Protocols 1 Grounding Grounds: –Common reference for the circuit –Safety What is the potential problem.
Design Discussion of Mechanical / Electrical Interfaces Bill Cooper (Fermilab) (Layer 1) VXD.
Shielded Wires Let us say that the voltages measured at the terminal of the receptor circuit are beyond the desired level. What can we do? Two common solutions.
11/22/2004EE 42 fall 2004 lecture 351 Lecture #35: data transfer Last lecture: –Communications synchronous / asynchronous –Buses This lecture –Transmission.
D. Nelson October 7, Serial Power Overview Presented by David Nelson
Grounding Guidelines Developed for LBNE
ELECTRICAL ENGINEERING Principles and Applications THIRD EDITION ALLAN R. HAMBLEY ©2002 Prentice-Hall, Inc. Chapter 9 Computer-Based Instrumentation Systems.
24/05/2010Rui De Oliveira1 Resistive protections for Bulk Micromegas Rui de oliveira, Joerg Wotschack Venetios Polychronakos.
Global Circuit Page 1  Basic Design Rule for Advanced PCB (1) 1. High speed current path Load Driving gate Current trace At low frequency current, follows.
False asymmetries/Ground Loops David Bowman 4/27/12.
Compilation of Dis-/Advantages of DC-DC Conversion Schemes Power Task Force Meeting December 16 th, 2008 Katja Klein 1. Physikalisches Institut B RWTH.
Getting faster bandwidth HervéGrabas Getting faster bandwidth - Hervé Grabas1.
Grounding.
Inductance Screening and Inductance Matrix Sparsification 1.
High Frequency Flex Project Definition Phase Project Lead: TBD Project Facilitator: John Davignon, HDPUG HDP User Group Member Meeting Santa Clara, CA.
Grounding & Shielding Ved Prakash Sandlas Director General
Carlos A. Martins ESS – Accelerator Division - RF Electrical Power Systems June 2 th, 2014 Design, construction and measurement.
TRIPLEGEM and VFATs at The Test Beam Area TRIPLEGEM and VFATs at The Test Beam Area N. Turini……reporter Eraldo Oliveri! Eraldo Oliveri main worker! N.
Transmission Line Studies Need to understand data transmission at 640 Mbps along bus tape. Analytic formulae FEA calculations from Roy. Network analyser.
Belle-II bKLM RPC Readout Power & Ground Discussion 12 th Belle II General Meeting Gerard Visser Indiana University CEEM 7/24/2012.
EMC review for Belle II (Grounding & shielding plans) PXD system - July 2012 Dr. Fernando Arteche.
Noise & Grounding Andrei Nomerotski (U.Oxford) 17 July 2007.
5 November 2002J.Pater - Systemtest Report1 Endcap Systemtest Current Grounding/Shielding status Recent Upgrades to sector Measurements with 6 Modules.
Common Base and Common Collector Amplifiers
Grounding.
Markus Friedl (HEPHY Vienna)
Meeting on Services and Power Supplies
DT & RPC Grounding STATUS
What Rare Minerals are in your cell phone?
Compilation of Dis-/Advantages of DC-DC Conversion Schemes
Open book, open notes, bring a calculator
Overview of T1 detector T1 is composed by 2 arms
Inductance Screening and Inductance Matrix Sparsification
Applied Electromagnetic Waves
Presentation transcript:

Grounding Studies Metal box sensor SVX4/hybrid Analog cable GND(20W) Signal return L0 support Kapton flex GND hybrid GND sensor GND Signal ground

L0 prototype module sensor ground hybrid ground

Effect of Grounding Structure inside the aluminum box. Hybrid only Sensor only Both hybrid and sensor

Equivalent (?) circuit (cont’d) Metal box sensor SVX4/hybrid Signal ground Signal return L0 support Kapton flex GND hybrid GND sensor GND Connection important Smaller inductance (or smaller loop) Least impedance = least inductance for high frequency (not resistance).

After putting extra grounding plane Note! Still the hybrid grounding is not perfect in terms of getting low inductance… but the effect of the extra ground plane is clearly seen. Single ground at hybrid Common ground at both hybrid and sensor

Importance of low inductance connection 1 wire between hybrid and the extra grounding plane. 3 wires 4 wires

Low inductance connection (cont’d) 2 wires (~4cm) 2 wires (~2cm)

Reducing the inductance Having lower inductance connection to GND seems crucial. L ~ (wire) length/radius: M=ml/2p[log(2l/r)-1] L = Y/I Y ~ area of the closed circuit People know these rules well, but sometimes forget to apply. But these rules are always critical for any grounding connections, both locally and generally. better

Low-pass filter board for HV How do we achieve???????????? Sensor grounding. The sensor and hybrid need to be connected through rigid ground plane. This should work also as a shielding.  extension of kapton flex with copper mesh embedded. Need to decide; multi point ground vs single point ground at hybrid end.  Marvin prefers multi point ground to avoid an accidental (capacitive) coupling which screws up the single point grounding scheme. Carbon Fiber Flex Circuits Vias Low-pass filter board for HV Sensor Copper Mesh

Grounding scheme for hybrid Low inductance grounding connection to hybrid is very important (let me repeat). Direct connection to the support structure.  minor concern on the L0B hybrids. Another option? Hybrid support rail as grounding plane. Kapton flex for the connection