Pixel Endcap Power Distribution Phase 1 Upgrade Plans Fermilab, University of Mississippi, University of Iowa Lalith Perera University of Mississippi CMS.

Slides:



Advertisements
Similar presentations
F. Formenti - ALICE forum 16/03/ Contacted some teams for system GND discussions: cases analyzed are presented here Planned to continue with others.
Advertisements

DC/DC Converters Markus Friedl (HEPHY Vienna) B2GM, 14 March 2012.
M.PEGORARO Grounding Workshop 24th Jan 08 DT GROUNDING & SHIELDING Presented by A. BENVENUTI.
8/11/2006 FPIX TB meeting L. Perera 1 Pixel Power Supply Response Measurement Lalith Perera - Univ. of Iowa Carlos Florez, Simon Kwan, Charles Newsom,
Control & Monitoring of DC-DC Buck Converters Satish Dhawan Yale University Power Distribution Working Group Meeting- Tuesday 24 February 2009 ATLAS Upgrade.
Tullio Grassi ATLAS–CMS Power Working Group 31 March 2010 DC-DC converters and Power Supplies requirements for CMS HCAL Phase 1 Upgrade.
Power Distribution Studies at Fermilab Aida Todri, FNAL ATLAS/CMS Power WG Meeting March 31 st, 2010.
Powering for Future Detectors: DC-DC Conversion for the CMS Tracker Upgrade Powering for Future Detectors: DC-DC Conversion for the CMS Tracker Upgrade.
Welcome Jan Sammet- 1 - A DC-DC converter based powering scheme for the upgrade of the CMS pixel detector TWEPP-11, Wien Arndt Schultz.
Infrastructure for LHCb Upgrade workshop – MUON detector Infrastructure for LHCB Upgrade workshop: MUON power, electronics, cable Muon upgrade in a nutshell.
DC/DC Converter Update Markus Friedl (HEPHY Vienna) B2GM, 22 July 2012.
Electromagnetic Compatibility of a DC Power Distribution System for the ATLAS Liquid Argon Calorimeter G. BLANCHOT CERN, CH-1211 Geneva 23, Switzerland.
DC-DC Buck Converter in Inner Detector Environment
Low Voltage Power Requirement of TOF FEEs. Maximum tray. Low Noise:  Periodic and Random Distortion (PARD) < few mV RMS Floating.
Switched capacitor DC-DC converter ASICs for the upgraded LHC trackers M. Bochenek 1,2, W. Dąbrowski 2, F. Faccio 1, S. Michelis 1 1. CERN, Conseil Européen.
Pulsed power poster introduction Cristián Fuentes 19/09/ > CERN DCDC converters group with F. Faccio and G. Blanchot March.
CMS Upgrade Workshop November Fermilab POWER DISTRIBUTION SYSTEM STUDIES FOR THE CMS TRACKER Fermilab,University of Iowa and University of Mississippi.
F. Arteche, C. Esteban Instituto Tecnológico de Aragón D. Moya, I. Vila, A. L. Virto, A. Ruiz Instituto de Física de Cantabria Powering requirements and.
LSST Electronics Review – BNL, January LSST Electronics Review BNL January Power & Voltage Plan R. Van Berg Electronics Mini-Review.
Modelling of TPM noise problems Greg, following discussions and measurements with David and Senerath.
NA62 GigaTracKer Working Group meeting Integration and GTK-carrier PCB design April 9, 2013 Michel Morel.
1 Module and stave interconnect Rev. sept. 29/08.
Design studies of a low power serial data link for a possible upgrade of the CMS pixel detector Beat Meier, Paul Scherrer Institut PSI TWEPP 2008.
Power Distribution Peter W Phillips STFC Rutherford Appleton Laboratory ECFA HL-LHC Workshop, Aix-les-Bains, 1-3 October 2013.
Laura Gonella – University of Bonn – 27/09/20111 The Shunt-LDO regulator for powering the upgraded ATLAS pixel detector Laura Gonella University of Bonn.
Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN
Power Distribution Existing Systems Power in the trackers Power in the calorimeters Need for changes.
Status of SVD Readout Electronics Markus Friedl (HEPHY Vienna) on behalf of the Belle II SVD Collaboration BPAC October 2012.
Work Package 3 On-detector Power Management Schemes ESR Michal Bochenek ACEOLE Twelve Month Meeting 1st October 2009 WPL Jan Kaplon.
W. Karpinski, Nov CMS Electronics week CMS Microstrip Tracker grounding & shielding of the CMS Tracker R. Hammarstrom (CERN EP/CMT) & W. Karpinski.
Electromagnetic Compatibility Test for CMS Experiment. Authors C. Rivetta– Fermilab F. Arteche, F. Szoncso, - CERN.
1 Possible integrated solutions to the power distribution puzzle in LHC upgrades F.Faccio, S.Michelis CERN – PH/MIC.
20 Mar 2007ACES workshop -- Switched Capacitors -- M. Garcia-Sciveres1 Switched Capacitor DC-DC converters Peter Denes, Bob Ely, Maurice Garcia-Sciveres.
The Inclusive (Measurement ) FVTX aka iFVTX sponsored by LANL-DR in FY ‘06-08 FPIX Chip Module/Hybrid Testcard Pixel Plane Assembly/Integration.
L0 Technical Readiness Review-Electronics Installation Linda Bagby L0 Electronics Installation  System Electronics Overview u Low Voltage s Filter.
1 07/10/07 Forward Vertex Detector Technical Design – Electronics DAQ Readout electronics split into two parts – Near the detector (ROC) – Compresses and.
ASIC buck converter prototypes for LHC upgrades
A common 400 Hz AC Power Supply Distribution System for CMS FEE. Authors C. Rivetta– Fermilab. F. Arteche, F. Szoncso, - CERN.
Compilation of Dis-/Advantages of DC-DC Conversion Schemes Power Task Force Meeting December 16 th, 2008 Katja Klein 1. Physikalisches Institut B RWTH.
CMS pixel telescope at MTEST 1 A. Kumar, S. Kwan, A. Prosser, R. Rivera, M. Turqueti, L. Uplegger.
A complete DC/DC converter ASIC for LHC upgrades S. Michelis, F. Faccio, G. Blanchot, I. Troyano CERN PH-ESE S.Saggini University of Udine, Italy Twepp.
Pixel power R&D in Spain F. Arteche Phase II days Phase 2 pixel electronics meeting CERN - May 2015.
9/17/2008TWEPP 2008, R. Stringer - UC Riverside 1 CMS Tracker Services: present status and potential for upgrade Robert Stringer University of California,
Infrastructure for LHCb Upgrade workshop – MUON detector Infrastructure for LHCB Upgrade workshop: MUON power, electronics Muon upgrade in a nutshell LV.
Saverio MINUTOLITOTEM Electronics W.G., 9 December T1 electronics status.
Rd07 Conference th June 2007 Florence, Italy 1 High frequency stepdown DC-DC converter with switched capacitors This work is part of the INFN DACEL.
Prototype Sensor Status and Measurements u Sensor Response Measurements u Mechanical Response u Noise Expectations u DAQ Status.
Tracking at the Fermilab Test Beam Facility Matthew Jones, Lorenzo Uplegger April 29 th Infieri Workshop.
Pixel Pilot system Hardware Status Simon Kwan August 28, 2012 CMS Pixel Upgrade Workshop, Grindelwald1.
Dr.F. Arteche EMC DEPFET Project: A general overview.
PXD – DEPFET PS noise emission tests Mateo Iglesias Fernando Arteche.
EMC issues for cabling and racks layout design. (Belle II – Grounding) F.Arteche.
Design summary Status of the development & production - test run with S3a and S3b prototype - performance tests To do list for production & development.
CMS Upgrade CERN April 27, 2010 W. Bertl PSI Power & Cooling: Design Status of BPIX.
29/05/09A. Salamon – TDAQ WG - CERN1 LKr calorimeter L0 trigger V. Bonaiuto, L. Cesaroni, A. Fucci, A. Salamon, G. Salina, F. Sargeni.
David Cussans, University of BristolCERN, 7 th October Air Core Magnetic Components for CMS SLHC Tracker DC-DC converters David Cussans, Powering.
EMC review for Belle II (Grounding & shielding plans) PXD system - July 2012 Dr. Fernando Arteche.
PADME Front-End Electronics
PIXEL CAEN Installation Status
TOF Low Voltage and High Voltage Systems Vahe Ghazikhanian UCLA Department of Physics and Astronomy V. Ghazikhanian July 21, 2005.
Calorimeter Mu2e Development electronics Front-end Review
M. Hansen, CERN S. Lusin, CMS TC / UW
Christian Veelken last updated 11/09/06
A few ideas about detector grounding and shielding D. Breton
T1 Electronic status Conclusions Electronics Cards:
ALICE Muon Tracking Upgrade EDR Answers
Work packages status in Torino and perspectives
Compilation of Dis-/Advantages of DC-DC Conversion Schemes
RPC Electronics Overall system diagram Current status At detector
Presentation transcript:

Pixel Endcap Power Distribution Phase 1 Upgrade Plans Fermilab, University of Mississippi, University of Iowa Lalith Perera University of Mississippi CMS Upgrade Workshop 10/28/2009

10/28/2009 CMS Upgrade Workshop 2 Current Endcap Power Distribution System PP0 port card adapter card ~40m cable CAEN A4603 PP1 filter card ~1m ~4m Power filter cards Cables from filter card Flex cable to the adapter card ~ 1.5m

10/28/2009 CMS Upgrade Workshop 3 Current endcap power cont… Each cable powers 6 panels ROC, 6 TBMs Vdig/Vana voltage sensing is done very close to the detector on the adapter card Overall resistance – mostly in the 40m cable –analog 0.6 ohms –digital 0.4 ohms VsetVconn I Analog1.6V3.6V3.4A Digital2.6V4.2V3.8A

10/28/2009 CMS Upgrade Workshop 4 Endcap Phase 1 Upgrade Requirements Current CAEN A4603 supplies are marginally adequate for the phase 1 upgraded endcap detector –lower safety margin –At the turn on, ROC (PSI46) takes a higher current –have to modify CAEN modules for more voltage/power Phase 1 upgrade - –7 blades per cable ROC, 14 TBMs Digital current will go up with the luminosity – say 30% VsetVconImax Vconmax I analog1.6V4.9V5.6A5.8V6A digital2.6V5.8V8.6A7V13A CAEN A4603 rating

10/28/2009 CMS Upgrade Workshop 5 Upgrade power requirements cont.. Pixel barrel detector has to use DC-DC converters to provide power with the existing power infrastructure. –Need modifications to CAEN modules suitable to use DC-DC converters Modifications to CAEN modules are expensive –quote 6k Euro/module for changing maximum V/I set values – for higher maximum driving voltage (Vcon) it would be more (a new design) We will follow the same scheme as the barrel detector using DC-DC converters –Same power system for the whole pixel detector –Experience for the Phase 2 upgrade

10/28/2009 CMS Upgrade Workshop 6 Possible layout for DC-DC converters Phase 1: Analog current 6A, digital current 9A We will need multiple converters per each segment/cable –DC-DC converter rating about 3A –3-4 converters for the analog –4 or 7 converters for digital They will be placed on a PCB equivalent to the current power filter card near the end flange Issues: –This is about 2m from the detector: there will be a voltage drop. How do we measure the actual voltage/current at the detector

10/28/2009 CMS Upgrade Workshop 7 Possible layout, cont... –Only fixed set of voltages are available (AMIS2). –Hardwired - less flexible in case require to change voltages. –May not be a problem with the new ROC. Even if the DC-DC converter chip is remotely programmable it is not straightforward to establish a communication path. –Few spare cables in the power cable may be used for signaling but the other end of the cable is at the CAEN racks (X2F balcony) –DCU/portcars are located about 1.5 from the end flange, communicate through FEC may need additional cabling in the service cylinder

10/28/2009 CMS Upgrade Workshop 8 Work done at the Fermilab We have built DC-DC converters with commercially available converters –used with the PSI46 and the CAPTAN system. Noise Susceptibility measurements –Studied the behavior of the ROC injecting noise to the digital power line Results have been presented in previous power WG meetings –No significant degradation of the ROC performance with noise in power. Threshold distribution (S-curve) LM2734 vs Linear regulator Test setup with DAQ /Power boards ROCs Vcal # of pixels

10/28/2009 CMS Upgrade Workshop 9 EMI Noise measurements We are in the process of setting up an EMI test stand –Followed CERN set up –Home built LISN similar to CERN design, 100 Ohm AC resistance 200k- 50 MHz

10/28/2009 CMS Upgrade Workshop 10 EMI noise measurement cont We also built a RF shield box –Metal box to shield from external RF sources –Inside covered with RF absorbing ceramic to minimize reflecting RF from the DUT. Ohms MhZ LISN impedance

10/28/2009 CMS Upgrade Workshop 11 Plans Test the DC-DC converter with the CERN power converter chip and make performance tests. –Performance of the pixel ROC –EMI noise Test the system at a 1.5 Tesla field Do a full scale test with actual power cable, modified CAEN power modules, DC-DC converter and an Fpix pixel detector panel