The Next Generation HSSD HART XL. Why Hart XL Aspirating Smoke Detection? l Earliest detection to enable business continuity l Extra time is required.

Slides:



Advertisements
Similar presentations
Prescient II Extinguishing Control Panels
Advertisements

Auto–Addressable Systems
CL100D series DSP controlled Uninterruptible power supplies.
Nexus 1-8 Loop (XP95) Analogue Addressable Control Panels
Philip Anderson National Sales Manager System Sensor Canada.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
- Product Overview – The LMD DEFLECTOMETER ® Series Inductive Loop Detector Why guess when you can know! © Copyright EDI 2013.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
Business Protection Earliest warning: minutes before combustion
© Castle Care-Tech Euro MERiDIAN Automatic Remote Maintenance Software ARM ® The flexible, automated solution to your security servicing needs.
Digital Celeris Integrated System Patient Room Isolation Room Programmable Controllers Local Display & Command Unit.
Remote Monitoring and Management Solutions ®
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
3U ATCA Shelf October Proprietary and Confidential-
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
April 2004 page 1 Confidential and propietary CentraLine Portfolio c l o s e t o y o u.
Representative Sampling By Chuck Abbott. Automatic Samplers.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
1 ASPIRATING SYSTEMS TRAINING e-series. 2 Overview e-series model range ASD Software  NetTracer  Detector Monitor  PipeTracer.
Monitoring Vibration on Tunnel Fans Safety First The worlds developing infrastructure creates many technical challenges for engineering and construction.
SafeLINC™ Fire Panel Internet Interface
AN INTRODUCTION TO THE CIRRUS PRO RANGE OF FIRE DETECTION DETECTORS
Wireless Remote Control Derail System CSX Atlanta, GA Track and Derail Graphic layout CSX Atlanta, GA.
 Wireless, Web-Based Monitoring System  Alarm/Event Notifications by Text Message and or  VPN Connection for Fast Response to Alarms and Events.
Precept Conventional Control Panels
© 2010 McQuay International 1 McQuay Delivered VAV System Product Overview October 2010.
Iris Range : «Unconventional» conventional detectors.
Addressable Fire Alarms
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
Copyright © 2008 Rockwell Automation, Inc. All rights reserved. Direct-to-Drive Technology Product Feature Overview.
Fire Detection Presentation
Benefit and advantages using Iris conventional detectors range.
ASPIRATING SYSTEMS TRAINING
GasGard® XL Monitor.
Enea Detectors Range.
BioWin ®. Bio Gas – The alternative energy source of the future! BioWin ® - Bio Gas Analysis of the future!
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
High Sensitivity Smoke Detection
Atrium Fire Protection
ACCESS CONTROL ExpansE - Distributed Access Control.
HP900 (ESP Protocol) Analogue Addressable Control Panels
1 Product & Technology Quality Excellence Support American Global Products Product & Technology TeSysPort Ethernet Interface for TeSys June 5, 2007.
Laser- based smoke detectors
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
Introduction to the ASD Suppression Actuation Threshold (ASAT) Calculator July _03_ASAT Calculator Sales and Marketing Introduction Presentation.
Intelligent Detection Systems l integrity of system confirmed continuously l pre-alarm facility l high flexibility of system configuration l performance.
THE INTELLIGENT SOLUTION FOR HIGH SENSITIVITY ASPIRATING SMOKE DETECTION SM AirSense Technology USA Limited April, 2007 Aspirating Smoke Detection TECHNOLOGY.
High Sensitivity Smoke Detection
1 Internal | ST/PRM2-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of.
Precept Marine Conventional Control Panels
Xplorer 1-2 Loop Analogue Addressable Control Panels From 1-2 loops EN54 2 & 4 Compliance Fully compatible with all Apollo XP95 and Xplorer devices Extensive.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
The D50 Is a state of the art environmental monitor using only the best quality components available. It offers multiple sensors in a single unit with.
Small Telco Facility Protection Small, business-critical spaces where business interruption cannot be tolerated.
1 System Design. 2 Primary Detection Secondary Detection Standards Pipe Design.
What can the Aerospace Industry Contribute to Very Early Fire Detection? Presented by: Stephen Lederer Marketing Manager, Honeywell, Inc.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
LEADING THE PACK.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
FLATPACK Rev.5 September 2002 Updated versions may be available.
Overview Presentation MKT-DSRV-P- 001E. Product Overview Network based video transmission product with on-board digital recording Allows analogue fixed/PTZ.
CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS
C1300 advanced circular chart recorder
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
Programmable Logic Controllers (PLCs) An Overview.
HELIOS AMX5000 Minimax GmbH & Co. KG © Minimax 2009.
Vibration Monitoring System M14
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Panel 4 Panel 1 Panel 6 Panel 3 Panel 5 Panel 2.
Presentation transcript:

The Next Generation HSSD HART XL

Why Hart XL Aspirating Smoke Detection? l Earliest detection to enable business continuity l Extra time is required for safe evacuation l Unnecessary suppression release must be avoided l Smoke is difficult to detect l Environmentally challenging areas l Aesthetics & concealed detection are important l Maintenance access is limited

Stages of Fire Obscuration Time

HART Detector Schematic

Detector Operation

Balanced sampling system

Pipe Network l Pipe has sealed end l Variable length pipe branches l Pipe layout as desired l Sample holes located where required l Sample hole sizes vary to balance system

Distributed Sampling Types l Computer calculated systems “SNIFF” l Balanced system l Equal sensitivity at each hole

Offshore platform Warehouse Computer/EDP rooms Libraries/Deed stores Heritage buildings Telecommunications High Sensitivity Smoke Detection Applications

Heritage Buildings & Architectural Landmarks l Important buildings l Discreet detection l High value articles l Aesthetics

Museums & Libraries l Valuable equipment artefacts etc. l Discrete detection l Busy environments l Life protection

Earliest Detection to Enable Business Continuity Critical processes that cannot incur any business disruption l Telecommunications facilities l Computer rooms l Banking operations l Production facilities l Internet Service Providers

Extra Time is Required for Controlled Evacuation Environments where rapid exit can be impeded l Underground Stations l Theatres l Public buildings l Airports

Unnecessary Suppression Release can be Avoided Early warning gives time to investigate to avoid unnecessary suppression release l Telecommunication facilities l EDP facilities l Computer rooms l Electrical sub-stations

Smoke is Difficult to Detect Environments with high ceilings, high air flows or vast open areas provide unique characteristics l Clean rooms l Warehouses l Aircraft hangers l Computer rooms l Atria

Environmentally Challenging Areas Aggressive environments with high levels of pollution or extreme temperature conditions can be protected reliably with acceptable maintenance levels l Cold Stores l Production areas l Paper mills l Underground tunnels l Mines

Aesthetics are Important & Replacement Impossible Interiors that must not be spoilt by unsightly conventional detectors - Hart XL can be installed unobtrusively l Cathedrals l Stately Homes l Museums l Art Galleries

Maintenance Access is Limited Hart XL can be located at an accessible location while the sampling pipework makes its way to the restricted area l Warehouses l Production machinery l Prisons l Restricted areas l EMC Controlled areas l Hospitals

In-Cabinet Sampling

Typical Computer/ EDP Room Set-up Air Handling Unit

The new Hart XL Product Design Benefits l Aesthetic l Pleasing design l Small size l Unobtrusive l Modular construction l Easy to maintain l Quick release components l Simple to use

Detection Performance l Superior particle counting technology l Dust particle discrimination l No filters l Digital processing l Automatic sensitivity & calibration checking

Particle Discrimination 10 micron particle size Typical smoke particle 10 micron particle size Typical dust particle Upper threshold Lower threshold Upper threshold Lower threshold Photodiode output

Detection Performance Benefits l High immunity smoke discrimination l Simple low cost maintenance l High reliability l High immunity to unwanted alarms l Long term stability l No re-calibration required

The Family of Hart XL Products & How they are Configured XL detectorDisplay Control Unit PSU & Batteries IIMPC

Configured for Top Inlet Configured for Bottom Inlet Wall or flush mounted, rear or side Outlet

Display Control Unit can be an Integral part of the Hart XL Detector Unit or located remotely No separate cabinet required for Display unit Detector retains local Status LED

Can be attached to the unit or remotely located Hart XL Unilaser with Power Supply & Battery Box Unit attached

Status Normal Indication Time and Date Cursor Menu Control Password Access for Further Information Hart XL Display Control Unit Large LCD Display Clear Information Three Colour Status LED

Hart XL Display Control Unit l Alarm condition l Ten bar graph scale l Location identifier l Fault type identified through password access

NormalPre-Alarm AlarmFault LED Status Indicator Hart XL Detector Unit- Option without Display Control Unit

Hart XL HSSD Networking Capability With the addition of the HART Intelligent Interface Module (IIM), up to 128 standard Hart XL HSSDs can be networked and displayed on a PC monitor

Networking Local PC Relays IIM Fire Alarm Control Panel Remote Display Option First Detector Last Detector Up to 127 detectors Address module Remote PC with modem Phone line Relays Network Loop Exhaust Inlet

Direct connection to PC for Programming and Downloading using LaserNet Software. No programmers or interfaces are required Programming and Diagnostics

Programming Options l Fixed or automatically set sensitivity l Hart XL 0.05%/m to 1%/m obscuration l Programmable relays l Referencing l Latching or non latching alarms l Two or Four levels of Alarm Diagnostics & Monitoring l Download history & event log l Full fault analysis l Dial in & dial out via modem monitoring l Intelligent interface module common alarm & fault relay outputs

History Log accessed through Lasernet

Hart XL Commissioning & Diagnostic Features Configuration parameters - can be saved to disk or printed Benefits l Simple operation for commissioning l Configuration or diagnostics l No special equipment required l Clear and simple information l Full analysis of fault or fire events

Laser Detector UnitMain Control Board Fan Assembly Servicing and Maintenance Clip-in modular assembly, removable cable connectors

Meeting our customers needs The New HART XL HSSD system from Kidde Fire Protection l Superior performance l Flexibility & simplicity l High quality information l High reliability l Operator friendly l Low cost of ownership l Easy to install, configure & commission