Precept Marine Conventional Control Panels

Slides:



Advertisements
Similar presentations
Prescient II Extinguishing Control Panels
Advertisements

Trystar Generator Docking Stations & Portable Power Cable
Variable Frequency Drives Bypass Options
Electrical Trunking Lincoln Robinson Caliphor Fagan Richard Lawrence
Nexus 1-8 Loop (XP95) Analogue Addressable Control Panels
Fischer Manufacturing is an electrical fabrication company based in New Brighton, MN. We specialize in building to engineering specified requirements.
ID to 8 Loop Intelligent Fire Alarm Panel
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
Installation. Indoor Unit Installation Typical Installation.
Discovery 1-4 Loop Analogue Addressable Control Panels
Mounting instruction – Hi-Fi-Series – HE-01 / HE-02 Specification : Color: black / silver Measurement: 445 x 460 x 135mm (w x d x h) Material: all-aluminium.
Material Handling Modules Configuring Your Own Work Cells.
Universal Holding Cabinet Two screws hold each side; four screws secure the top.
 Salient characteristics / Approvals  Non-illuminated Switches  Illuminated Switches  Pilot Lights  Contact Elements Control & Signalling Devices.
Introduction System Schematic ~ LON-FO NC EC200 LOOPS 2-4 FIBRE OPTIC
Applied Control Systems
3U ATCA Shelf October Proprietary and Confidential-
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
MIS 1.5 Hardware Overview.
The Vanjen Group • Manufacture's Representative – Power Generation/Oil & Gas • Covering TX, OK, LA, AK, in some cases NM and MS • Extensive.
Manufacture's Representative – Power Generation/Oil & Gas Covering TX, OK, LA, AK, in some cases NM and MS Extensive Power Gen Experience Extensive Docking.
Precept Conventional Control Panels
8/10/20151 THE BASICS OF INFRATECH HEATER CONTROLS.
INTRUSION ALARM TECHNOLOGY
Addressable Fire Alarms
RP-2000 Series Deluge & Agent Releasing Panels
Wiring Schematics 101 Electrical Symbols Supplemental Inflatable Restraint (SIR) or Supplemental Restraint System (SRS) Icon This icon is used to alert.
An Introduction to the Windows-based PC Programming Tool Version 0.91
© 2006, ZTE Corporation. All rights reserved.   E300 Series Mini-type Integrated Universal Inverter.
NFS System Components & Installation.
Installation. Indoor Unit Installation Typical Installation.
Confidential Battery Operated Photoelectric Detector AX-100TFR (30m) AX-200TFR (60m)
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Single Loop Analogue addressable fire control Panel
High Sensitivity Smoke Detection
The AFD-01, part of FIRE END range of steel doors, is an economical flush door set, for most internal or external applications in commercial buildings.
ECP Extinguishing Control Panel. Extinguishing Control Panel General overview Technical overview.
An Introduction to the R3 19 inch Rack The R3 control system comprises a number of different plug in modules, each of which is dedicated to a particular.
TL70 The Choice is Yours: You choose how to order and build the TL70 with the flexibility to customize the tower light as needed and change positions in.
HP900 (ESP Protocol) Analogue Addressable Control Panels
KIDDE FIRE PROTECTION Vega Peer to Peer Networking.
SIP POU cooler Installation Guide. Getting Started The SIP 2000 can be easily installed in most POU coolers in just a few minutes. The tools needed are.
Please read all the instructions carefully before the installation. Installation shall be carried out by experienced mechanic. Follow the steps in the.
Framed Canopy Fitting Instructions Contents – 6- Angled frame fixing brackets 1 x handle pack 6 x self drilling tech screws 3 keys 1x door 6 x coach screws.
AUP2G57 configured as flip flop Dual Configurable Logic Design Contest.
NFS System Components & Installation.
IPod analyses Paul, Ethan, Niels. Casing: Plastic cover Dual injection molding ▫White cover ▫Transparant layer on top of this Advantages ▫Lower part cost.
CB200 Conventional Control Panels
-Proprietary and Confidential-
2 December, 2015 New Conventional Fire Control Panel.
The Next Generation HSSD HART XL. Why Hart XL Aspirating Smoke Detection? l Earliest detection to enable business continuity l Extra time is required.
CB200 e Cabinet Extinguishant Control Panels Designed for cabinet extinguishant systems 2 zone extinguishant co-incidence operation Selectable discharge.
Xplorer 1-2 Loop Analogue Addressable Control Panels From 1-2 loops EN54 2 & 4 Compliance Fully compatible with all Apollo XP95 and Xplorer devices Extensive.
SmartMQn Motor Horner APG, LLC September 9, 2008.
Dual Sparkle Circuit Green connections are wires – they can be any colour. Make sure all + and - connections match up. Make sure the larger battery terminal.
Puissant Panel User Training Esc.. 09:11:35 ACTIVE # * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE.
Product Overview. Hazardous & Industrial Enclosures ATEX & IECEx Compliant.
GmbH Specialist hotel application ComplianceCommercial refrigeration Industrial refrigeration Light Industrial Gas Detection MGS-550 Product Portfolio.
New Energy Centre at Megawatt Park 15 April 2014.
User Operation Presentation
MKTG 2016.
MKTG 2016.
ActivRAC® 16P Mobilized Storage System
Technician Operation Presentation
Fin & Countertop Sample Kit Instructions
Honeywell Fire Systems Group RFX SLC L1: Det.159 Mod. 159 SLC L2: Det.159 Mod. 159 SLC L3 ~ L10 EIA 485 EIA 232 RDP Up to 32 Noti-Fire-Net Onyxworks.
Presentation transcript:

Precept Marine Conventional Control Panels Lloyds approved to BS5839 pt 4 and ENV & ENV2 2, 4, 8, 16 and 32 zones 240V / 24V dual supply options Easily-removable chassis & removable cable-entry grommets Single man test facility Membrane fascia with tactile switches and user-friendly controls Non latching option on zone 1 Two-stage alarm outputs Zonal and relay outputs & remote silence, reset & evacuate inputs Complies with EMC and LVD directives For use with marine-approved accessories Esc.

Surface Cabinets All cabinets are manufactured from sheet steel and finished in satin texture epoxy powder stove paint. Top entry grommets and rear entry knockouts are provided for ease of wiring. Cabinet colour reference is: RAL7035 Textured - Light Grey. For details of panel dimensions - see Application Guide. Esc.

For details of dimensions - see Application Guide. Semi-flush Bezels The semi-flush bezel locates to the rear of the bevelled edge of the back box, leaving the bevelled edge and door raised out from the wall. It is finished in the same colour as the back box and is fitted by means of pinch bolts, thus avoiding the need to drill the cabinet. For details of dimensions - see Application Guide. Esc.

Fully-flush Bezels Esc. The fully-flush option is achieved by fixing a flat bezel assembly to the standard back box, replacing the standard door. Custom-made to a high quality, full-flush bezels are available in brass, stainless steel, or painted. The panel comes with assembly already fitted but can if necessary be supplied for later on-site fitting, although this may be a little time-consuming. This option not submitted to Lloyds for marine approval. Esc. For details of dimensions - see Application Guide.

Mechanical Assembly Esc. Display and motherboard chassis are removable for ease of wall mounting. Multiple earth termination points located adjacent to cable entries. Mounting points for the Precept motherboard chassis. 24V battery set. Cabinet mounting holes. Esc.

User Controls Esc. User’s zone identification label. Lloyds approval details. The Precept Marine panel has clear, unambiguous LED indications. These single-function user controls are easy to operate. User operating instructions. Esc.

Motherboard This is the motherboard for the 2/4 zone Precept Marine panel. Motherboards for the 8 and 16 zone panels are shown in the Application Guide. The fault LEDs, fuses and DIL switch are easily accessible for the engineer when the user display board has been removed. Esc.

Typical Wiring Schematic Apollo Marine S60 detectors are illustrated, but the Precept panel supports a wide variety of other manufacturers’ detectors - details in the Application Guide. This is a typical Precept wiring illustration as it appears in the product documentation. Alarm Circuit terminals Zone terminals Repeater panel terminals. One per zone, One each for common fault, remote inputs for silence alarms, reset and evacuate, 24V and 0 V supply This option was not submitted to Lloyds for Marine Approval Battery Terminals 2 fire and 1 fault c/o relay Esc. DIL switch for panel configuration

Panel Configuration The engineer’s controls are located on the bottom of the control board. They are in the form of a 4-way DIL switch. Switch 1 Pulsing or continuous alarms Switch 2 Non-latching zone (zone 1) Does not operate fire relays (Disallowed under BS5839 pt 4) Switch 3 One man test facility Switch 4 Operates the processor fault counter in accordance with BS5839 pt 4 (8, 16, 32 zone panels only) or Disable auxiliary fire relay on evacuate (4 zone panel only) Switch 2 & 4 Shop unit specification (4 zone panel only) Esc.

Marine Approved Field Devices Esc.