Section 13 Analytical Voltammetry.

Slides:



Advertisements
Similar presentations
EEE 529 Microsystems Amperometric Biosensors
Advertisements

Cells and Potentials. Voltaic Cells In spontaneous oxidation- reduction (redox) reactions, electrons are transferred and energy is released. © 2009, Prentice-Hall,
DO NOW: Questions in M.C. packet. 1. An oxidation-reduction reaction involves the transfer of electrons 2. Reduction is the gain of electrons and decrease.
Electrochemical Cells
Introduction to Electroanalytical Chemistry
Unit 2 B Voltammetry and Polarography
VOLTAMMETRY A.) Comparison of Voltammetry to Other Electrochemical Methods 1.) Voltammetry: electrochemical method in which information about an analyte.
Yat Li Department of Chemistry & Biochemistry University of California, Santa Cruz CHEM 146C_Experiment #8 Surface Electrochemistry: Adsorption of Polyoxometalate.
ERT207 Analytical Chemistry Oxidation-Reduction Titration Pn Syazni Zainul Kamal PPK Bioproses.
VOLTAMMETRY A.) Comparison of Voltammetry to Other Electrochemical Methods 1.) Voltammetry: electrochemical method in which information about an analyte.
+ current, cathodic ic + potential, V - potential, V - current, anodic
Amperometric Biosensors. Introduction Enzyme Catalyzed redox reactions The function of the enzyme is to generate or consume an electroactive species in.
OK, so you’ve made the Ru complexes. Now, how are you going to determine what it does with DNA? Will your complex bind DNA, like this? Will the other complexes.
Voltammetry Nov 16, 2004 Lecture Date: March 27th, 2006.
Electrochemistry for Engineers
Experimental techniques Linear-sweep voltammetry At low potential value, the cathodic current is due to the migration of ions in the solution. The cathodic.
Voltaic Cells Chapter 20.
Lecture 244/1/05. Quiz 1) Balance the following redox equation: Ag(s) + NO 3 -  NO 2 (g) + Ag + (aq) 2) What is the oxidation number for Chlorine in.
Electrochemistry Chapter 4.4 and Chapter 20. Electrochemical Reactions In electrochemical reactions, electrons are transferred from one species to another.
Electrochemistry Chapter 21. Electrochemistry and Redox Oxidation-reduction:“Redox” Electrochemistry: study of the interchange between chemical change.
Electrochemistry. Electrochemical Cells  Electrons are transferred between the particles being oxidized and reduced  Two types –Spontaneous = Voltaic.
Other Electrochemical Methods
Section 10 Electrochemical Cells and Electrode Potentials.
ELECTROCHEMICAL CELLS
Reduction- Oxidation Reactions (1) 213 PHC 10th lecture (1) Gary D. Christian, Analytical Chemistry, 6 th edition. 1.
E LECTROCHEMISTRY Kristin Shepard Brooke Petersen.
Chapter 18 Notes1 Chapter 18 Electrochemistry 1. review of terms; balancing redox equations 2. galvanic cell notation, relationships 3. standard reduction.
Ch 17: Instrumental Methods in Electrochemistry Principle parts of a personal glucose monitor (covered in the section on Amperometry) The following chapter.
Chapter 20 Electrochemistry. © 2009, Prentice-Hall, Inc. Oxidation Numbers In order to keep track of what loses electrons and what gains them, we assign.
VOLTAMMETRY A.) Comparison of Voltammetry to Other Electrochemical Methods 1.) Voltammetry: electrochemical method in which information about an analyte.
Electrochemistry Electrolysis.
Oxidation-Reduction Dr. Ron Rusay Fall 2001 © Copyright 2001 R.J. Rusay.
Electrochemistry Oxidation-Reduction Dr. Ron Rusay Spring 2004 © Copyright 2004 R.J. Rusay.
REVISION ELECTROCHEMISTRY. OXIDATION Oxidation is a loss of electrons The oxidation number increases E.g. Electrodes where oxidation take place will reduce.
Best seen broken into four categories Part 1: Ion Selective Electrodes Part 3: Step Voltammetry Part 2: Amperometric Sensors Part 4: Cyclic Voltammetry.
Electrolysis  Section Electrolysis Occurs in an electrolytic cell Can be the molten salt, or ions in solution Cations are attracted to the cathode.
Consider the reduction half reaction: M z+ + ze → M The Nernst equation is E = E ө + (RT/zF) ln(a) When using a large excess of support electrolyte, the.
Chapter Menu Electrochemistry Section 20.1Section 20.1Voltaic Cells Section 20.2Section 20.2 Batteries Section 20.3Section 20.3 Electrolysis Exit Click.
In voltaic cells, oxidation takes place at the anode, yielding electrons that flow to the cathode, where reduction occurs. Section 1: Voltaic Cells K What.
Dr. Rasha Hanafi Lecture 8 Non- potentiometric methods of analysis: Amperometry and Voltammetry (Polarography) Dr. Rasha Hanafi Dr. Rasha Hanafi, GUC.
Home Reading Skoog et al. Fundamentals of Analytical Chemistry. Sections 18A, 18C ( in chapter 18 ), Chapter 23.
Electrochemistry. To obtain a useful current, we separate the oxidation and reduction half-reactions so that electron transfer occurs thru an external.
Introduction to Electroanalytical Chemistry
Chapter 20 Electrochemistry
CHEMISTRY CHAPTER 19 LEO SAYS GER
Chapter 10.7 Electrolysis.
Lecture 7a Cyclic Voltammetry.
Electrolysis.
Chp 17 Electrochemistry.
Electron Transfer and Redox Reactions
Electrolysis.
1. Introduction to Electrochemical Cells
Electrochemistry.
Redox Reactions.
Electrochemistry.
An electrolytic cell uses electricity to do a chemical reaction.
Electrochemistry Chapter 17.
Aim # 36: What is the difference between a
Chapter Fifteen VOLTAMMETRY AND ELECTROCHEMICAL SENSORS
3- Oxidation-Reduction (Redox) titration
A Deeper Insight into the Meaning of k° and α.
Voltametric techniques Chapter 2 Prof. Rezvani.
2. Electrochemical techniques complementary to cyclic voltammetry.
from a battery or other external energy source
Cyclic Voltammetry Dr. A. N. Paul Angelo Associate Professor,
Chapter 15 Notes Oxidation number - number of electrons an element wants to gain or lose to become stable. Determining oxidation number: Ex. CaSO4 CCl4.
Electrochemistry Kenneth E. Schnobrich.
What is a redox reaction?
Redox in Electrochemistry
Presentation transcript:

Section 13 Analytical Voltammetry

Fig Setup for voltammetric measurements. There is a micro working electrode, a reference electrode, and an auxiliary electrode. Current flows between the working and auxiliary electrodes. The voltage between the working and reference electrodes is recorded. There is a micro working electrode, a reference electrode, and an auxiliary electrode. Current flows between the working and auxiliary electrodes. The voltage between the working and reference electrodes is recorded. ©Gary Christian, Analytical Chemistry, 6th Ed. (Wiley)

Fig Different types of voltammetric curves. (a) Stirred solution or rotated electrode. (b) unstirred solution, and (c) stepwise reduction (or oxidation) of analyte or of a mixture of two electroactive substances (unstirred solution). When the decomposition potential for reduction or oxidation of the analyte is reached, electrolysis begins. A limiting current is reached when the rate of electrolysis equals the rate of diffusion. In an unstirred solution, the diffusion layer extends futher into the solution with time, so the limiting current decreases exponentially. Stepwise electrolysis occurs for species with different oxidation states, or for mixtures. When the decomposition potential for reduction or oxidation of the analyte is reached, electrolysis begins. A limiting current is reached when the rate of electrolysis equals the rate of diffusion. In an unstirred solution, the diffusion layer extends futher into the solution with time, so the limiting current decreases exponentially. Stepwise electrolysis occurs for species with different oxidation states, or for mixtures. ©Gary Christian, Analytical Chemistry, 6th Ed. (Wiley)

Fig Construction of an oxygen electrode. This is a complete cell. Oxygen diffuses through the membrane and is reduced at the platinum cathode ring. The anode coil is a Ag/AgCl reference electrode. This is a complete cell. Oxygen diffuses through the membrane and is reduced at the platinum cathode ring. The anode coil is a Ag/AgCl reference electrode. ©Gary Christian, Analytical Chemistry, 6th Ed. (Wiley)

Fig Amperometric glucose electrode. Glucose oxidase is immobilized on the Pt electrode. This catalyzes reaction of glucose with oxygen: glucose + O 2 = gluconic acid + H 2 O 2 The H 2 O 2 is oxidized at the Pt electrode by applying +0.6 V vs. Ag/AgCl: H 2 O 2 = O 2 + 2H + + 2e - Glucose oxidase is immobilized on the Pt electrode. This catalyzes reaction of glucose with oxygen: glucose + O 2 = gluconic acid + H 2 O 2 The H 2 O 2 is oxidized at the Pt electrode by applying +0.6 V vs. Ag/AgCl: H 2 O 2 = O 2 + 2H + + 2e - ©Gary Christian, Analytical Chemistry, 6th Ed. (Wiley)

Fig Redox modified electrode. Red is the analyte being measured, in the reduced form. The mediator layer, M ox, acts as an electrocatalyst for the electrooxidation of an analyte with slow electron transfer. So a smaller potential needs to be applied, giving better selectitvity. The mediator layer, M ox, acts as an electrocatalyst for the electrooxidation of an analyte with slow electron transfer. So a smaller potential needs to be applied, giving better selectitvity. ©Gary Christian, Analytical Chemistry, 6th Ed. (Wiley)

Fig Ultramicro electrode. The microdisk electrode is about 5-30  m. This smaller than the diffusion layer thickness. This results in: enhanced mass transfer independence on flow increased signal-to-noise ratio S-shaped curve in an unstirred solution can measure in nonaqueous solvents i l = 2nFDCd The microdisk electrode is about 5-30  m. This smaller than the diffusion layer thickness. This results in: enhanced mass transfer independence on flow increased signal-to-noise ratio S-shaped curve in an unstirred solution can measure in nonaqueous solvents i l = 2nFDCd ©Gary Christian, Analytical Chemistry, 6th Ed. (Wiley)