Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Peter Križan University of Ljubljana and J. Stefan Institute RICH counters for HERA-B and Belle.

Slides:



Advertisements
Similar presentations
Picosecond Timing Workshop 18 November Sales meeting 2005 Discovering the Future.
Advertisements

Barrel PID upgrade K. Inami (Nagoya-u) and PID group - R&D status - TOP counter - iTOP - Focusing DIRC - To do, cost estimation.
Peter Križan, Ljubljana Peter Križan University of Ljubljana and J. Stefan Institute The HERA-B RICH counter.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan 1.Introduction 2.Recent.
Assisi – 23 June 2005 Tito Bellunato 1 Status of the LHCb RICH detector and the HPD Beauty 2005 Assisi – 23 June 2005 Tito Bellunato – Università degli.
Peter Križan, Ljubljana April 20, 2005Super B Factory Workshop, Hawaii Peter Križan University of Ljubljana and J. Stefan Institute For Belle Aerogel RICH.
Could CKOV1 become RICH? 1. Simulations 2. Sensitive area of the detection plane 3. Example of a workable solution 4. Geometrical efficiency of the photon.
10 Picosecond Timing Workshop 28 April PLANACON MCP-PMT for use in Ultra-High Speed Applications.
Lens ALens B Avg. Angular Resolution Best Angular Resolution (deg) Worst Angular Resolution (deg) Image Surface Area (mm 2 )
Latest developments in Hamamatsu Large Format PMTs
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
T. Sumiyoshi (TMU) 30, Nov del Carmen 1 Development of HPD (HAP D) Photon-detector for the Aerogel RICH Photon-detector for the Aerogel.
SuperKEKB to search for new sources of flavor mixing and CP violation - Introduction - Introduction - Motivation for L= Motivation for L=
The HERMES Dual-Radiator Ring Imaging Cerenkov Detector N.Akopov et al., Nucl. Instrum. Meth. A479 (2002) 511 Shibata Lab 11R50047 Jennifer Newsham YSEP.
Carsten Schwarz PANDA June 2004 CID Cherenkov Imaging Detectors ● RICH software at HERMES, Ralf Kaiser, Glasgow ● Present status of DIRC, C.S., GSI ● Spiralling.
Peter Križan, Ljubljana March 17, 2006 Super B Workshop, Frascati Peter Križan University of Ljubljana and J. Stefan Institute Aerogel RICH and TOP: summary.
Position Sensitive SiPMs for Ring Imaging Cherenkov Counters C.Woody BNL January 17, 2012.
A Reconstruction Algorithm for a RICH detector for CLAS12 Ahmed El Alaoui RICH Workchop, Jefferson Lab, newport News, VA November th 2011.
May 31, 2008 SuperB PID sessionMarko Starič, Ljubljana Marko Starič J. Stefan Institute, Ljubljana Report on hardware tests and MC studies in Ljubljana.
Blair Ratcliff2 nd Workshop on SuperB, Frascati, March Status Update: the Focusing DIRC Prototype at SLAC Blair Ratcliff Blair Ratcliff Representing:
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
RICH detectors for LHCb Tito Bellunato INFN Milano-Bicocca On behalf of the LHCb RICH collaboration 10th International Conference on Instrumentation for.
Performance of the PANDA Barrel DIRC Prototype 1 GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt 2 Goethe-Universität Frankfurt Marko Zühlsdorf.
Photodetection EDIT EDIT 2011 N. Dinu, T. Gys, C. Joram, S. Korpar, Y. Musienko, V. Puill, D. Renker 1 Micro Channel plate PMT (MCP-PMT) Similar to ordinary.
Development of 144 Channel Multi-Anode HPD for Belle Aerogel RICH Photon Detector Development of 144 Channel Multi-Anode HPD for Belle Aerogel RICH Photon.
Peter Križan, Ljubljana May 10, 2007 SuperB V Peter Križan University of Ljubljana and J. Stefan Institute PID in the endcap region: proximity focusing.
J. Stefan Institute, Ljubljana Institute: Multidisciplinary institute, largest research institution in Slovenia Physics (solid state,
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Development of the RICH Detectors in LHCb S. Easo Rutherford-Appleton Laboratory June 5, 2002 RICH2002 PYLOS, GREECE For the LHCb-RICH Group.
TOP counter overview and issues K. Inami (Nagoya university) 2008/7/3-4 2 nd open meeting for proto-collaboration - Overview - Design - Performance - Prototype.
work for PID in Novosibirsk E.A.Kravchenko Budker INP, Novosibirsk.
Development of TOP counter for Super B factory K. Inami (Nagoya university) 2007/10/ th International Workshop on Ring Imaging Cherenkov Counters.
PID for super Belle (design consideration) K. Inami (Nagoya-u) - Barrel (TOP counter) - Possible configuration - Geometry - Endcap (Aerogel RICH) - Photo.
Timing properties of MCP-PMT K.Inami (Nagoya university, Japan) - Time resolution - Lifetime - Rate dependence Photon Detector Workshop at Kobe,
July 4, 2008 SuperBelle Meeting, KEKPeter Križan, Ljubljana Peter Križan University of Ljubljana and J. Stefan Institute Burle MCP PMTs as photon detector.
Updates at Nagoya univ. K.Inami (Nagoya) - Photon detector R&D - Lifetime improvements - Simulation design study.
BURLE update Peter Križan Friday meeting, Mar 24, 2006.
Study of a Proximity Focusing RICH with Aerogel Radiator for Future Belle Upgrade Toru Iijima Nagoya University October 18, th International Workshop.
2004/11/30RICH04 Workshop 1 Timing Property of MCP-PMT for Single Photon Detection Toru Iijima Nagoya University Contents Studies of MCP-PMT performance.
Barrel PID upgrade K. Inami (Nagoya) Ljubljana, Hawaii, Cincinnati and PID group - R&D status - Structure design - Prototype study - Beam test - Photon.
The RICH Detectors of the LHCb Experiment Carmelo D’Ambrosio (CERN) on behalf of the LHCb RICH Collaboration LHCb RICH1 and RICH2 The photon detector:
Barrel PID summary K.Inami (Nagoya) Summary of R&D at Hawaii, Cincinnati, Ljubljana and Nagoya.
October 2002Sienna, JL. Faure, DAPNIA/SPP In 8th Topical Seminar on Innovative Particle and Radiation Detectors Jean-louis Faure CEA-DAPNIA-SPP Progress.
Particle Identification with the LHCb Experiment
RICH meeting, F.Muheim1 Proposal for MAPMTs as Photodetectors for the LHCb RICH Franz Muheim University of Edinburgh on behalf of the MAPMT group.
Tests of a proximity focusing RICH with aerogel as radiator and flat panel PMT (Hamamatsu H8500) as photon detector Rok Pestotnik Jožef Stefan Institute,
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan for the GLD Calorimeter.
Aerogel RICH & TOP counter for super KEKB Y.Mazuka Nagoya University June 14-16, 2006 The 3 rd SuperB workshop at SLAC.
TORCH – a Cherenkov based Time-of- Flight Detector Euan N. Cowie on behalf of the TORCH collaboration E N Cowie - TORCH - TIPP June 2014.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Matthias Hoek Institut für Kernphysik Next Generation Cherenkov Counters* *For Accelerator Experiments 52. International Winter Meeting on Nuclear Physics.
Peter Križan, Ljubljana September 17, 2008 SuperB PID Peter Križan University of Ljubljana and J. Stefan Institute Forward PID: - SiPM as photon detectors.
FARICH status E.A.Kravchenko Budker INP, Novosibirsk, Russia.
The Ring Imaging Cherenkov Detectors for LHCb Antonis Papanestis CCLRC – RAL On behalf of the LHCb RICH group.
Prospect of SiPM application to TOF in PANDA
Fabio, Francesco, Francesco and Nicola INFN and University Bari
Proximity focusing RICH with TOF capabilities for the Belle upgrade
Particle Identification (PID) at HIEPA Experiment
Status of the PandaRoot simulation of the Forward RICH
Focusing Aerogel RICH with SiPM Photodetectors
Photon detector R+D for the forward PID device
Ljubljana contribution
Particle Identification in LHCb
E.A.Kravchenko Budker INP, Novosibirsk, Russia
Multianode Photo Multipliers for Ring Imaging Cherenkov Detectors
Progress on the Focusing DIRC R&D
LHCb Particle Identification and Performance
Particle Identification with the LHCb Experiment
The MPPC Study for the GLD Calorimeter Readout
Performance test of a RICH with time-of-flight information
Presentation transcript:

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Peter Križan University of Ljubljana and J. Stefan Institute RICH counters for HERA-B and Belle PID upgrade CBM RICH Workshop, GSI, March 6-7, 2006

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Contents HERA-B RICH RICH for the Belle PID upgrade Summary

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop 920 GeV protons p + A   s = 41.6 GeV The HERA-B Experiment

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop The HERA-B Detector

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop HERA-B RICH Requirements: High QE over ~3m 2 Rates ~1MHz per channel Long term stability NIM A516 (2004) 445

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop HERA-B RICH: rates on the photon detector Few MHz per channel

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop HERA-B RICH photon detector Cadidates – original: CsI based wire chamber with pads TMAE based wire chamber with ‘egg-crate’ structure Backup solution: Multianode PMTs Hamamatsu R5900 series

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop CsI chamber A lot of very good results NIM A300 (1991) 213; NIM A307 (1991) 145; NIM A364 (1995) 243 Show-stoppers for the use in HERA-B: High rate instabilities NIM A371 (1996) 151 Ageing NIM A387 (1997) 146

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop TMAE chamber Photons enter the chamber from the left. Optical thickness: along the anode wires. Rather fast (<100ns) cc

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop TMAE chamber Excellent performance: No feed-back photons Stable at high rates NIM A371 (1996) 289 Show-stopper for HERA-B: ageing NIM A414 (1998) 170 Possible remedy: heating in situ NIM A515 (2003) 302

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop HERA-B RICH photon detector Status in 1996: TMAE and CsI have serious problems in long term operation at very high rates Hamamatsu just came out with the metail foil multianode PMTs of the R5900 series: first multianode PMTs with very little cross-talk Tested on the bench and in the beam: excellent performance  easy decision  NIM A394 (1997) 27

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Multianode PMTs Hamamatsu R5900-M16 (4x4 channels) R5900-M4 (2x2 channels) Key features: Single photon pulse height spectrum Low noise Low cross-talk

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Multianode PMTs Uniformity: Large variation (3-4x) in amplification – no problem in photon counting (in case of low noise) Good uniformity in QE x photo-electron collection efficiency QE x collect. eff.  NIM A478 (2002) 391

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop HERA-B RICH tiling scheme Match the occupancy and resolution needs: Finer granularity in the central part Upper detector half: M16 PMTs M4 PMTs

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Multianode PMTs Large statistics (2300 pcs) QA tests  NIM A442 (2000) 316

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Multianode PMT read-out Front-end readout electronics: Based on ASD8 read-out chips ASD8 = 8 channel amplifier, shaper and discriminator: ● ENC ~ /pF ● shaping time ~ 10ns ● sensitivity ~ 2.5mV/fC ASD8 board: 16 channels (2 x ASD8 chips)  NIM A541 (2005) 610 Voltage divider: integrated in the PMT base board

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Light collection system Light collection system (imaging!) to: -Adapt the pad size -Eliminate dead areas

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Light collection system Light collection system features: -Only slightly aspheric -Easy to fabricate plastic lenses -Mold production, cheap -Integrated into the support structure T   of the lens system, QE   of PMT 

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Mechanics inside outside

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Photon detector: Upper half

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Photon detector form Minimize the error due to spherical aberration. Specific: Mirror tilted by 9 0. The optimal surface could be approximated by a deformed cyllinder, by about 20cm from the naive focal surface at R/2, and slightly tilted.  NIM A433 (1996) 124

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Mirrors Spherical mirrors: hexagons of 7mm Pyrex glass, coated with 200nm Al and 30 nm of MgF 2 Planar mirrors: rectangles of float glass

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Mirrors Each segment: computer controlled motors for alignment

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Mirrors - alignment Initial alignment: with teodolite inside the vessel Final alignment: using data Use rings with photons from different mirror segments for relative alignment  NIM A433 (1999) 408

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop HERA-B RICH performace Little noise, very clear rings with ~30k read- out channels

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Performance Typical event... Background mainly from other tracks  adapt the extented maximum likelihood analysis with expectation-maximisation algorithm  NIM A433 (1999) 279

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Performance Figure of merit: N 0 =42/cm (=expected) Number of photons for =1 particles: 33 Single photon resolution:    0.8 mrad for finer granularity region (R5900-M16 tubes)   .0 mrad for coarser granularity region (R5900-M4 tubes)

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Performace It actually works very well!  NIM A516 (2004) 445 Idenfication of pions: pion efficiency, p, K fake probability Idenfication of kaons: K efficiency, pion fake probability Idenfication of protons: p efficiency, K fake probability

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop HERA-B RICH photon detector: how could we do it today? We employed R5900 PMTs with a rather low active area fraction of 25% (36% for dense packing) + optical system. Today: could go for a better active a. ratio  In the meantime the same package comes without the nose at the sides - R7600 and recently with an even better active area ratio (83%): R or use the H8500 (‘flat pannel’) PMT  52mm

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Belle Upgrade for Super-B SC solenoid 1.5T New readout and computing systems CsI(Tl) 16X 0  pure CsI (endcap) Aerogel Cherenkov counter + TOF counter  “TOP” or DIRC + Aerogel RICH Si vtx. det. 4 lyr. DSSD  2 pixel/striplet lyrs. + 4 lyr. DSSD Tracking + dE/dx small cell + He/C 2 H 5  remove inner lyrs. fast gas+Si r<20 cm  / K L detection 14/15 lyr. RPC+Fe  tile scintillator

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Belle upgrade – side view Two new particle ID devices, both RICHes: Barrel: TOP or focusing DIRC Endcap: proximity focusing RICH

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Endcap: Proximity focusing RICH K/  separation at 4 GeV/c  c (  ) ~ 308 mrad ( n = 1.05 )  c (  )–  c (K) ~ 23 mrad d  c (meas.) =   ~ 13 mrad With 20mm thick aerogel and 6mm PMT pad size  6  separation with N pe ~10

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Beam test: Cherenkov angle resolution and number of photons Beam test results with 2cm thick aerogel tiles: >4  K/  separation -> Number of photons has to be increased.  0 ~ 15mrad N pe ~6 NIM A521 (2004)367; NIM A553 (2005) 58

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop How to increase the number of photons? What is the optimal radiator thickness? Use beam test data on  0 and N pe Minimize the error per track:  track     N pe Optimum is close to 2 cm 00 N pe  track     N pe

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop How to increase the number of photons without degrading the resolution? normal Radiator with multiple refractive indices NIM A548 (2005) 383  stack two tiles with different refractive indices: “focusing” configuration

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Beam tests Photon detector: array of 16 H8500 PMTs

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Beam tests: events Clear rings, little background Photon detector: 4x4 H8500 PMTs

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop 4cm aerogel single index 2+2cm aerogel Focusing configuration – data

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Photon detectors for the aerogel RICH Needs: Operation in high magnetic field (1.5T) High efficiency at >350nm Pad size ~5-6mm Candidates: large area HPD of the proximity focusing type MCP PMT (Burle 85011) N.B. H8500 PMT unfortunately does not work in high B field

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Development and testing of photon detectors for 1.5 T Candidate: large area HPD of the proximity focusing type -10kV 15~25mm e- Multialkali photocathode Pixel PD or APD R&D project in collaboration with HPK Tests with single channel and 3x3 channel devices look very promissing. 1pe 2pe 3pe 4pe

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop HPD development 59mm x 59mm active area (65%), 12x12 channels Ceramic HPD box Several tests carried out. Problems with sealing the tube at the window-ceramic box interface.

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Photon detector R&D: Burle MCP-PMT BURLE MCP-PMT: ● multi-anode PMT with 2 MCPs ● 25  m pores ● bialkali photocathode ● gain ~ 0.6 x 10 6 ● collection efficiency ~ 60% ● box dimensions ~ 71mm square ● 64(8x8) anode pads ● pitch ~ 6.45mm, gap ~ 0.5mm ● active area fraction ~ 52% ● fast: ~55ps time resolution

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Burle MCP-PMT bench tests Study uniformity of the sensitivity over the surface Example: single channel response of the H8500 PMT count rates - all channels: charge sharing at pad boundaries single channel response: ● uniform over pad area ● extends beyond pad area (charge sharing) 2300 V Proc. IEEE NSS 2004

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Burle MCP-PMT bench tests charge sharing at pad boundaries Proc. IEEE NSS 2004 ● slice of the counting rate distribution including the central areas of 8 pads (single channels - colored, all channels - black)

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop ● BURLE MCP-PMT mounted together with an array of 12(6x2) Hamamatsu R5900-M16 PMTs at 30mm pitch (reference counter) Burle MCP PMT beam test

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Resolution and number of photons (clusters) Burle MCP PMT beam test ●  ~13 mrad (single cluster) ● number of clusters per track N ~ 4.5 ●  ~ 6 mrad (per track) -> ~ 4  /K separation at 4 GeV/c Operation in high magnetic field: ● the present tube with 25  m pores only works up to 0.8T, for 1.5T need ~10  m ● 10  m version with 4 channels available since June, some tests done (Va’vra) Number of photons per ring: too small. Possible improvements: ● bare tubes (52%->63%) ● increase active area fraction (bare tube 63%->85%) ● increase the photo-electron collection efficiency (from 60% at present up to 70%) -> Extrapolation from the present data 4.5 ->8.5 hits per ring  : 6 mrad -> 4.5 mrad (per track) -> >5  /K separation at 4 GeV/c Aging of MCP-PMTs ? Open questions

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Belle barrel upgrade: TOP counter Simulation 2GeV/c,  =90 deg.  -ray, had. int. KK Time-of-Propagation counter: Measurement of –One (or two coordinates) with a few mm precision –Time-of-arrival Excellent time resolution < ~40ps for single photons at B=1.5T

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Belle barrel upgrade: TOP counter Tests on the bench: amplification and time resolution in high magnetic field. 3 MCP-PMTs studied –Burle (25  m pores) –Novosibirsk (6  m pores) –Hamamatsu (6 and 10  m pores) All: good time resolution at B=0 25  m pore tube does not work at 1.5T Hamamatsu SL10 NIM A528 (2004) 763

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop TOP: Beam tests 2100 V

Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Summary What are the messages from our experience for the CBM RICH designers? HERA-B RICH: R5900 MA PMTs have proven to be an extremly reliable and easy to use detector for Cherenkov photons. Excellent performance in very adverse conditions. Belle forward region PID upgrade: excellent performance of the flat pannel PMT (R8500) in beam tests; for operation in 1.5T field, Burle MCP PMT seems to be a good candidate (with some changes).