Stuti Misra Dipika V. Patel Jennifer P. Craig Charles N.J. McGhee Department of Ophthalmology, New Zealand-National Eye Centre, Faculty of Medical & Health.

Slides:



Advertisements
Similar presentations
Endothelial Cell Changes as an Indicator for Upcoming Allograft Rejection Following Descemet Membrane Endothelial Keratoplasty Jack Parker Jr, MD; Lamis.
Advertisements

3D Stereo Data for the Estimation of Pavement Construction Quantities and Costs Mr. Donald L. Reid Department of Public Works Nashville Metropolitan Government.
Corneal morphology in Epithelial Basement Membrane Dystrophy: A large cross-sectional study with in vivo confocal microscopy Johan Germundsson M.D, Per.
TELEMEDICINE IN THE MODERN EYE BANK Eric Abdullayev MD, MBA,CEBT International Sight Restoration Eye Bank (ISR), Tampa FL, USA Author Has No Financial.
Pooja B. Jamnadas, MD, Peter Russo, OD, William Bonk, Shuchi Patel, MD Loyola University Chicago, Stritch School of Medicine, Department of Ophthalmology,
Swept Source Optical Coherence Tomography for Evaluation of Posterior Corneal Changes after Refractive Surgery Dr. Tommy Chung Yan Chan Dr. Vishal Jhanji.
World Cornea Congress VII 2015 Akilesh Gokul PhD Candidate1
Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.
Biomechanical Properties of Healthy and Keratoconic Corneas Evaluated Using an Ultra-High-Speed Scheimpflug Camera nznec Department of Ophthalmology University.
What is OCT? Ultrahigh resolution optical coherence tomography (UHR OCT) is an upcoming new technology that allows non-invasive, optical medical diagnostic.
David Zadok MD, Isaac Avni MD
University of Verona Eye Clinic Department of Neurological and Motor Science Head: Prof. Giorgio Marchini Prevalence of Corneal Ectasia in Patients With.
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. David Zadok, MD, Yakov Goldich, MD, Yaniv Barkana,
The authors have no financial interest in the subject matter of this poster. The Effect of Topical Epigallocatechin Gallate (EGCG) Treatment on Murine.
Deep Stromal Dissection for Endothelial Keratoplasty Obtained with a Femtosecond Laser and a Microkeratome with Different Head Advancement Speeds. A Scanning.
Department of Ophthalmology
Ahmad Kheirkhah MD, Rodrigo Muller MD, Deborah Pavan-Langston MD, Andrea Cruzat MD, Pedram Hamrah MD Ocular Surface Imaging Center, Massachusetts Eye and.
Saratov State University ______________________________________________ Department of Optics & Biophotonics __________________________________________________.
Changes of Ocular Surface in a Rabbit Model of Short Term Desiccating Stress Wei-Li Chen, MD, PhD Associate Professor, National Taiwan University Hospital.
Evaluation of Epithelial Changes in Limbal Stem Cell Deficiency Using in Vivo Confocal Microscopy ERIC CHAN, Luxia Chen, Sophie X. Deng Cornea and Uveitis.
Evaluation of Interface Reflectivity and Corneal Aberrations following DSAEK Hamid Khakshoor, MD Professor of Ophthalmology Mashhad University of Medical.
H. Ueno, G. Ferrari, T. Hattori, T. Funaki, D.R. Saban, S.K. Chauhan, R. Dana The authors have no financial interest in the subject matter of this poster.
Photorefractive Keratectomy in Posterior Polymorphous Dystrophy [CONTROL ID: ] Edward W. Trudo 1, Kraig S. Bower 2, Charles D. Coe 2, Denise A. Sediq.
Anterior Segment Optical Coherence Tomography and In Vivo Confocal Microscopy Findings in Femtosecond Laser- Assisted Keratoplasty Kurt H. Kelley, MD;
Femtosecond Laser ‘Second Pass’ for Incomplete LASIK Flaps Due to Suction Loss and Analysis of Flap Morphology 1 Anil Vedula*, Takeshi Ide*, Payman Haft*
Inhibition of Experimental Corneal Neovascularization by Bevacizumab (Avastin) Baskent University, School of Medicine Department of Ophthalmology, Ankara.
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. Yakov Goldich, MD, David Zadok MD, Yaniv Barkana,
Metallic Foreign Body Embedded in the Posterior Lens Capsule Helen R. Moreira, MD; Michele S. Todman, MD; Paul J. Botelho, MD Division of Ophthalmology,
Confocal scan study of corneal grafts following Descemet-on versus Descemet-off deep anterior lamellar keratoplasty Zare M, Feizi S, Rezaie M, Hoseini.
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
Descemet-Stripping Automated Endothelial Keratoplasty Grafts Prepared from Endothelial Side Using a 500 kHz Femtosecond Laser: Six-Month Outcomes Jesper.
1 Non-contact Specular Microscopy for Evaluation of Corneal Endothelium in Early Fuchs’ Endothelial Corneal Dystrophy Jianyan Huang 1, MD, PhD; Tudor Tepelus.
Tissue Engineered Human Corneas for In Vitro Testing May Griffith 1, Rosemarie Osborne 2, Eric J. Suuronen 1, Christopher R. McLaughlin 1 and Mitchell.
Science 10 – Unit C BIOLOGY Chapter 1 – The Microscope.
Khakshoor Hamid Eslampoor Alireza Saffarian Ladan
Epithelial Dendritic Cells and Subbasal Nerve Plexus in Infectious Keratitis: An In Vivo Confocal Microscopy Study. Andrea Cruzat, MD, Dimos Mantopoulos,
Thomas John, MD Clinical Associate Professor Loyola University at Chicago Maywood, Illinois Ritika Patel Chicago Medical School.
PTERYGIUM PROGRESSION DETECTED BY IN VIVO CONFOCAL MICROSCOPY Martone Gianluca, Malandrini Alex, Balestrazzi Angelo, Tosi Gian Marco, Pichierri Patrizia,
Diminished Endothelial Cell Counts in Corneas with Krukenberg Spindles Authors: Tod M. Haller1, Chad B. Haller2, Melvin L. Haller1, Judah Beck3, Keith.
Comparing Factors Affecting Surgically Induced Astigmatism
The authors have no conflicting interest in the subject matter of this poster. In Vivo Evaluation of DSAEK Interface with Scanning- Laser Confocal Microscopy.
Date of download: 5/30/2016 Copyright © 2016 American Medical Association. All rights reserved. From: Correlation of Retinal Nerve Fiber Layer Measured.
Evaluating Post Laser Refractive Surgery Corneal Thickness Using Artemis-2 Very High Frequency Arc-Scanning Ultrasonography Versus Pentacam * † Sharon.
Liquifaction Method and Extent of Posterior Capsule Opacification: Two-Year Follow-up Marie Kalfertova, Mariya Burova, Pavel Rozsival, Nada Jiraskova Nada.
Correlation of in-vivo confocal microscopy findings with clinical severity of aniridia related keratopathy. Mandal N 1 Shortt A.J. 1,2,3 1. Cornea and.
Poster# P36 Comparison of Techniques of Measuring Anterior Chamber Depth and Corneal Curvature in Indian Eyes Sujata Das, MS, FRCS Anjula Kumari, B.Optom.
Date of download: 6/29/2016 Copyright © 2016 American Medical Association. All rights reserved. From: Anterior Keratocyte Depletion in Fuchs Endothelial.
Department of Ophthalmology, University of Ulsan College of Medicine,
In Vivo Confocal Microscopy after Corneal Collagen Crosslinking
From: Early Corneal Nerve Damage and Recovery Following Small Incision Lenticule Extraction (SMILE) and Laser In Situ Keratomileusis (LASIK) Invest. Ophthalmol.
From: Staining Ability and Biocompatibility of Brilliant Blue GPreclinical Study of Brilliant Blue G as an Adjunct for Capsular Staining Arch Ophthalmol.
From: The Use of Autologous Serum in the Development of Corneal and Oral Epithelial Equivalents in Patients with Stevens-Johnson Syndrome Invest. Ophthalmol.
From: Elevated Expression of O-GlcNAc–Modified Proteins and O-GlcNAc Transferase in Corneas of Diabetic Goto-Kakizaki Rats Invest. Ophthalmol. Vis. Sci..
From: Early Corneal Nerve Damage and Recovery Following Small Incision Lenticule Extraction (SMILE) and Laser In Situ Keratomileusis (LASIK) Invest. Ophthalmol.
From: Stiffening of Rabbit Corneas by the Bacteriochlorophyll Derivative WST11 Using Near Infrared Light Invest. Ophthalmol. Vis. Sci ;53(10):
From: Anti-Inflammatory and Antioxidative Effects of Camellia japonica on Human Corneal Epithelial Cells and Experimental Dry Eye: In Vivo and In Vitro.
From: Cibinetide Improves Corneal Nerve Fiber Abundance in Patients With Sarcoidosis-Associated Small Nerve Fiber Loss and Neuropathic Pain Invest. Ophthalmol.
From: Early Corneal Nerve Damage and Recovery Following Small Incision Lenticule Extraction (SMILE) and Laser In Situ Keratomileusis (LASIK) Invest. Ophthalmol.
From: Corneal Cross-Linking with Riboflavin and UV-A in the Mouse Cornea in Vivo: Morphological, Biochemical, and Physiological Analysis Trans. Vis. Sci.
From: The TFOS International Workshop on Contact Lens Discomfort: Report of the Subcommittee on Neurobiology Invest. Ophthalmol. Vis. Sci ;54(11):TFOS71-TFOS97.
Invest. Ophthalmol. Vis. Sci ;50(2): doi: /iovs Figure Legend:
Nuclear Length-to-Width ratio
Prepared by Dr Diane Aston, IOM3
Comparison of Automated and Manual Measurements of Horizontal Corneal Diameter in Contact Lens Wearers Using Orbscan Eye Metrics Function and Orbscan 11z.
Three-Year Follow-up after LASIK in Eye with Extremely Thin Corneal Bed Hidemasa Torii, MD, Kazuno Negishi, MD, Murat Dogru, MD, Takefumi Yamaguchi, MD,
Use of Intravital Multi-Photon Microscopy to Study In Vivo Migratory Kinetics of Corneal Bone Marrow-Derived Cells Pedram Hamrah, M.D., Dimosthenis Mantopoulos,
Microfibril angles of softwood and hardwood pulp fibres
Jianjiang Xu, Wenqing Zhu, Jiaxu Hong
Cardiomyocytes cultured on microgroove-patterned structural color hydrogel films. Cardiomyocytes cultured on microgroove-patterned structural color hydrogel.
IHC characterization of 15-week-old mature corneal organoid in suspension. IHC characterization of 15-week-old mature corneal organoid in suspension. Confocal.
Presentation transcript:

Stuti Misra Dipika V. Patel Jennifer P. Craig Charles N.J. McGhee Department of Ophthalmology, New Zealand-National Eye Centre, Faculty of Medical & Health Sciences, University of Auckland, New Zealand Authors have no financial interest to declare

Traditionally light and electron microscopy have been used to visualise the cornea at a cellular level but these can be only performed ex-vivo. In vivo confocal microscopy enables the corneal nerve microstructure to be viewed non-invasively. To date, published data on the human corneal sub-basal nerve plexus configuration is limited to only 4 eyes. Therefore, the extent of variation between individuals or between the eyes of an individual remains unknown.

The aim was to compare the configuration of the sub-basal nerve plexus in both eyes of four normal subjects.

Four participants (2 females, 2 males), age range years Laser scanning in vivo confocal microscopy (IVCM) was performed on both eyes of each subject on separate days within two weeks A contiguous montage of IVCM images was prepared using Macromedia Freehand 10 (Macromedia Inc, USA). Sub-basal nerve density and angle of nerve rotation were analysed using analySIS 3.1 software (Soft Imaging System, Germany)

Laser scanning confocal microscope HRTII Rostock Corneal Module (Heidelberg Engineering, Germany) Non-invasive Corneal layers visible at a cellular level (a) HRT base unit (b) Corneal module Confocal image of a normal eye (a) Epithelium (b) Sub-basal nerve plexus (c) Keratocytes and beaded stromal nerves (d) Keratocytes and thicker stromal nerves in mid stroma (a)(b) (c)(d) 400µm

Four confocal images arranged to demonstrate preparation of montage 

Sub-basal epithelial nerve plexus map, centred on the whorl region 400µm

Whorl pattern of (a) the right eye and (b) the left eye of the same individual demonstrating a similar clockwise pattern in both (a)(b) 400µm

Nerve density (whorl region) o Right eyes ± 4.95 mm/mm² o Left eyes ± 4.19 mm/mm² (t-test, p=0.59) Whorl orientation - clockwise in both eyes Nerve rotational angle o Right eyes 61.0 ± 16.2° o Left eyes 59.2 ± 16.4° (t-test, p=0.45)

This is the first study to report the sub-basal nerve plexus configuration in paired human eyes. No statistical difference was observed in nerve density and nerve rotation between the eyes. The sub-basal nerve plexus whorl demonstrated a clockwise configuration in both the right and left eyes in all subjects in this study.

Interestingly, the sub-basal corneal nerve plexus in both right and left eyes of all individuals in the current study exhibited a whorl pattern with clockwise orientation similar to previous reports of non-paired right and left eyes (Patel and McGhee 2005; Efron 2007). The comparable nerve plexus configuration in the right and left eyes suggests that the mirror imaging corneal topographic patterns, typically observed between eyes, is not obeyed in respect to corneal innervation.

University of Auckland Doctoral scholarship University of Auckland PReSS account Study participants