The I 2 Air Fluid Protocol; The Eco-friendly method for the elimination of bio-fouling in heat exchangers utilizing I 2 infused mixed media.

Slides:



Advertisements
Similar presentations
Australian water filter.
Advertisements

Aseptic Technique: Media and Equipment
ENERGY CONVERSION MME 9617A Eric Savory
Chapter 24 Dental Unit Waterlines
The I 2 Air Fluid Protocol; The Eco-friendly method for eliminating bio-fouling in heat exchangers and cooling towers utilizing I 2 infused mixed media.
I 2 Air Infuser. CONFIDENTIALITY STATEMENT: This presentation, including all attachments, is confidential and/or may include proprietary content or intellectual.
Bacterial reduction in water and surfaces using the I 2 Air Infusion method. Click to continue.
Functional benefits for heat exchangers cleaned with I 2 Air Infusion. Click to continue.
Basic Refrigeration Cycle
December 2010 Your Natural Microbial Service Provider Efficiency and Cost-Effectiveness.
ChE 131: Transport Processes
SANITARY DESIGN PRINCIPLES FOR FACILITIES. ZONES OF CONTROL.
Chilled Water, Hot Water, Heat Pump and Glycol Loops
Cold-Plus™ Refrigerant Enhancer
Surface Water Treatment Plant
Antunes Water Filtration Technologies Introduces to You:
Chapter 3.2: Heat Exchanger Analysis Using -NTU method
Drug Delivery & Tissue Engineering Laboratory
Normal Operating Parameters Maintenance Schedule Common Problems Normal Operating Parameters Maintenance Schedule Common Problems ClearWater Tech, LLC.
Industrial Ventilation - A major control measure Dr. AA, UTM.
The I 2 Air Fluid Protocol; The Eco-friendly method for the elimination of bio-fouling in heat exchangers.
Microbial Ecology Ecology: interactions among living things and their environments Think globally act locally: microbes metabolize in microenvironments,
Microbial Ecology Ecology: interactions among living things and their environments –Think globally act locally: microbes metabolize in microenvironments,
Law of Conservation of Energy
Cleaning and disinfection a summary FS
COMMERCIAL REFRIGERATION
Heat exchangers The device at which heat exchange between two fluids at different temperatures and separated by a solid wall occurs is called heat exchanger.
Cold-Plus™ Refrigerant Enhancer
Cold-Plus™ by TRIFECTA DISTRIBUTORS LLC
BCE Environmental Engineering Water Treatment Mdm Nur Syazwani binti Noor Rodi.
OZONE DRINKING WATER SYSTEM. CONTENTS Properties of Ozone Production of Ozone Water Treatment Plant – 25 m 3 /hr Ozone Generation System.
Designing an Internal Corrosion Program NACE Eastern Area Conference Roy D. Fultineer Jr.
Fuel Tank Inerting Joint Airbus/FAA, A320 Flight Tests
Sustainable Management Resources Inc Join SMRI as we work on: “Creating a Sustainable New Economy” SMRI, San Diego CA, ~ ~ Steve Kaplan ~
Day 1 Please get a computer up and running. Launch molecular workbench Objectives: –Explain the difference between heat and temperature –Explain the three.
JC Equipments Pvt. Ltd Heat Exchanger Manufacturers Off Ph : , Tele Fax :
Health, Medicine and Biotechnology Opportunity Accurate Measurement of OPA Concentration for Disinfection Applications Benefits: An analytical process.
INTRODUCTION Definition:
Dealing with Impurities in Processes and Process Simulators ChEN 5253 Design II Terry A. Ring There is not chapter in the book on this subject.
Reverse Osmosis Feed Treatment, Biofouling, and Membrane Cleaning
Cleaning & Sanitizing for Food Plants. 22 Dec 07Effective Cleaning2 Introduction All equipment must be cleaned and sanitized prior to use and following.
NOTES: 2.2 – Properties of Water. Water Overview… Water is perhaps the most important compound in living organisms Because so many substances can dissolve.
The Family of Shell and Tube Heat Exchangers P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Family members with Simple Geometrical.
UNIT THREE: Matter, Energy, and Earth  Chapter 8 Matter and Temperature  Chapter 9 Heat  Chapter 10 Properties of Matter  Chapter 11 Earth’s Atmosphere.
Aquatic Ecology374 First Term of year Nuha AL-Abdulhadi Dr.promy lab 9.
The Nature of Solubility
Introduction to Energy Management. Week/Lesson 9 part a Evaporative Cooling and Cooling Towers.
Chemistry of Life Bio.2 a,b – Cells Macromolecules Molecules Atoms.
By: Jim Kibby Fouling and ROI Tools (Return On Investment)
Temperature and Specific Heat Capacity 11/5/10. I.Temperature & Heat  temperature and heat are not the same thing!  temperature = a measure of the average.
Overview of HVAC Filtration
Membrane Processes Introduction Membrane processes represent an important subset of filtration processes as there are very few pollutants found in water.
Presentation Title Presented by Joe Blow Heat Transfer 101 & ROI.
HYDRO NANO GAS - AN ANSWER TO GREENHOUSE GASES presented by sai sujan piriya.
What is Degassing? Degassing is removing dissolved gases from liquids. Applications includes: Removing biogenic hydrogen sulfide from groundwater, used.
NOTES: 2.2 – Properties of Water
GROUND SERVICING OF VARIOUS SUB SYSTEMS
In-feed and Amine Sweetening 11/4/09
Case sample of a CT option
Thermal mass dynamics 1.00 Heat absorption
WHAT IS HX……??? Heat exchangers are equipment that transfer
CUTTING FLUIDS Lesson Objectives
Basis Operations in Industrial Fermentations
Bacterial reduction in water using the
Effects of Free and Forced Convection on the Convection Coefficient and Time to Steady State for Various Objects Christian Roys, Jon Zywusko, and Julie.
Functional benefits for heat exchangers cleaned with I2 Air Infusion.
12. Heat Exchangers Chemical engineering 170.
PANDA Collaboration Meeting
PowerScrub™ Evac System Cleaner;
Presentation transcript:

The I 2 Air Fluid Protocol; The Eco-friendly method for the elimination of bio-fouling in heat exchangers utilizing I 2 infused mixed media.

CONFIDENTIALITY STATEMENT: This presentation, including all attachments, is confidential and/or may include proprietary content or intellectual property. This presentation is intended for the sole use of the individual(s) or entity being presented to. If you have received this presentation by mistake, please notify the sender by immediately and delete this message from your system. If you are not the intended recipient, be aware that any disclosure, copying, distribution or use of the contents of this information is strictly prohibited. Protocol and application is based upon the art and science of U.S. Patent No. 7,329,385 and is the intellectual property of the inventor(s).

The Problem Heat exchangers are the heart of any cooling system found in industry. Unfortunately, the efficiency of any exchanger can be compromised when geo- thermal wells or cooling towers become contaminated by bacteria of many kinds. Iron, sulfur and other species of bacteria adhere to the walls of the exchanger and form a gelatinous coating known as bio-film. Bio-film causes a reduction in heat transfer through; Occluded space which increases temperature and pressure through decreased flow within the geothermal or cooling tower side of the heat exchanger. Thermal insulating matter on the plates impedes heat transfer. Pitting corrosion on plate surfaces reduces plate heat transfer coefficient. Additionally, bio-film and planktonic bacteria can move downstream to diffusion wells where occlusion occurs on screens and in cooling towers where bacterial contamination occurs.

Temp. Inlet PSI Flow Heat transfer Flow Corrosion caused by bacteria.

The Answer The APF Cleaning Protocol and I 2 Air Infused mixed media. The APF protocol is used to clean the interior surfaces of the heat exchanger of existing bio-film. It is a once a month procedure that requires approx. one hour per month labor time and no disassembly of the exchanger. It consists of the following: First, voiding the exchanger of any standing water within the exchanger through the introduction of air using the APF manifold.

Second, introduce the I2 AFI cleaning solution. Third, provide for continuous 30 min. agitation. Fourth, liquefy bio-film. Fifth, purge exchanger of cleaning solutions. Finally, start of normal water flow. Note: cleaning solution is retained only in the exchanger and not allowed into the injection well. This is an Eco-friendly protocol.

Throughout the month, the plate walls are continually bathe in extremely low dose I 2 bubbles which keep bio-films from forming in various ways.

Turbulent bubbles lift and dislodge bio-film. Low dose Iodine reduces microbial content Bubble flurry prevent planktonic bacteria from adhering to plate surface. Bubbles impart low dose iodine into water for downstream disinfection of cooling tower and diffusion screens

The patented I 2 Air Fluid Infusor Cartridge produces I 2 infused bubbles that are dosed for accurate elution. Elutes only grams per month into water stream. Adjustable based on need and standards. are unaffected by water temperature, turbidity, mineral content or pH. converts to Eco-Friendly iodide after contact with bacteria. will not effect most materials. will have the same effect on microbes as much higher concentrations. are negatively charged.

The cell wall is exposed continually to new low dose iodine within the air bubbles. Iodine is drawn into the cell and key amino acids in the respiratory chain are broken down. The bacteria is destroyed. The I2 infused air molecule eliminates free floating bacteria and bacteria resident in existing biolms. Iodine converts to Eco-friendly iodide and moves downstream.

The continual profusion of I2 infused bubbles keeps the plates clean providing optimal heat transfer. The bubbles continue on to the diffusion well screens and cooling towers where bio-film is eliminated at those sites.

Does it really work? 300 GPM system, plate heat exchanger/ geothermal well; Inlet pressures average 13 psi and outlet pressures 4 psi. Total labor: 75 minutes/month! What about diffusion screens? “Hi Mike, We have been running one 300 GPM supply well. We have left all 3 diffusion wells open. Each diffusion well has a capacity of 300 GPM. In order to determine if all 3 diffusion wells are working properly, we turned two off at a time so that we tested each diffusion well by itself to ensure that it was taking 300 GPM. All 3 took the 300 GPM of water without increases in incoming or outgoing pressure at the heat exchanger. I took that to mean that all 3 diffusion wells are working properly.”

The benefits The APF Cleaning Protocol and I 2 Air Infused mixed media; Increases system efficiency. Effectively removes bio-film and minerals. Eliminates exchanger breakdown. Prevents the reformation of bio-films. Does not use caustic chemicals. Uses very low dose iodine. Does not allow exchanger cleaner into groundwater or well System down time is under 2 hours per month. Low cost of use. Does not expose staff and environment to bio-films and dangerous chemicals. Environmentally friendly.