12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University ICD Status High Voltage Changes Invalid Alarms ICD channels in caladdress.

Slides:



Advertisements
Similar presentations
ATLAS Tile Calorimeter Performance Henric Wilkens (CERN), on behalf of the ATLAS collaboration.
Advertisements

M. Dracos LNGS, 03 August Target Tracker. M. Dracos LNGS, 03 August Rate tests SM1 Sensor (1,3,4) no signal Plane 6 absent Sensor (1,2,7)
D0 Calorimeter Meeting 11 Feb 2003 Lee Sawyer Louisiana Tech University ICD Update: January Shutdown Work Lee Sawyer On behalf of Andy White, Mark Sosebee,
SPD commissioning Ricci, Míriam, Daniel, Edu, Hugo et al. from 1.
Mechanical check of PMT Check base: Remove black tape and two small screws that secure the base. Tighten the nuts on the BNC connector for the HT input.
Neutron Detector Shutdown Procedure 1.Turn Off Photomultiplier Tube High Voltages There are two HV channels per red module, each with it’s own black dial.
Veto Wall Test Hyupwoo Lee MINERvA/Jupiter Group Meeting Feb, 13, 2008.
Veto Wall Test Hyupwoo Lee MINERvA/Jupiter Group Meeting Oct, 3, 2007.
6 June 2002UK/HCAL common issues1 Paul Dauncey Imperial College Outline: UK commitments Trigger issues DAQ issues Readout electronics issues Many more.
Veto Wall Test Hyupwoo Lee MINERvA/Jupiter Group Meeting July 18, 2007.
SSD Operations Manual March 2014 SSD: 4 th layer of vertex detector Heavy Flavor Tracker Silicon Strip Detector – Operations Manual PXL Inserted from this.
13 January All Experimenters’ MeetingAlan L. Stone - Louisiana Tech University1 Data Taking Statistics Week of 2003 January 6-12 We had to sacrifice.
Status of QBPM Electronics and Magnet Movers as of June 3 rd 2008 D. McCormick, J Nelson, G White SLAC S Boogert Royal Holloway Y. Honda, Y.Inoue KEK.
The MINER A Operations Report All Experimenters Meeting Howard Budd, University of Rochester July 8, 2013.
12 February 2002 Cal Mtg - D0 Collaboration Alan L. Stone Louisiana Tech University ICD LED Run Status Purpose ADC to GeV Conversion Basics of ICD LED.
Status of NA62 straw electronics and services Peter LICHARD, Johan Morant, Vito PALLADINO.
FEE LVPS 1. INTRODUCTION This section describes the Low Voltage Power Supplies (LVPS) for the TPC FEEs and RDOs. Plans currently call for all of the old.
25 March DOE Review Alan L. Stone Louisiana Tech University The ICD Project  Purpose & Location within the DØ Detector  History: Run 1 vs 2.
FLC Group Test-beam Studies of the Laser-Wire Detector 13 September 2006 Maximilian Micheler Supervisor: Freddy Poirier.
Figure 1: ICD Single Channel Block Diagram Schematic PMT High Voltage Supply (see Figure 4 & 4a) LED Pulser PMT Calibration (see Figure 6) ICD Scintillator.
1 Status of the calorimeter PMT’s time alignment LHCb CALO meeting Anatoli Konoplyannikov /ITEP/ Introduction Development status of the PMT time.
The MINER A Operations Report All Experimenters Meeting Howard Budd, University of Rochester June 17, 2013.
1 Online Calibration of Calorimeter Mrinmoy Bhattacharjee SUNY, Stony Brook Thanks to: D. Schamberger, L. Groer, U. Bassler, B. Olivier, M. Thioye Institutions:
ATLAS Liquid Argon Calorimeter Monitoring & Data Quality Jessica Levêque Centre de Physique des Particules de Marseille ATLAS Liquid Argon Calorimeter.
25-May-03 jadzia warchol, ext. 8341, phone Calibration of FPD detector Content Page General2 Calibration 3 Taking data (Calibration or Pedestal.
Calorimeter Status Nirmalya Parua, Brook.
17 February All Experimenters’ MeetingAlan L. Stone - Louisiana Tech University1 Data Taking Statistics Week of 2003 February Dedicated some.
Status of the Remote HV System 10 June 2015 TileCal week, upgrade session Roméo Bonnefoy, Romain Madar and François Vazeille ● Summary of performances.
On behalf of joint ITEP / IHEP team: A. Arefiev, N. Filimonov, T. Kvaratskheliya, I. Machikhiliyan, P. Shatalov, T. Zakoryuchkina, A. Zhokhov, S. Zvyagintsev.
L0 Technical Readiness Review-Electronics Installation Linda Bagby L0 Electronics Installation  System Electronics Overview u Low Voltage s Filter.
High Gain Mystery of WS(1-5) Solved (Hopefully…) C.Woody HBD Meeting April 13, 2010.
D0 Status: 01/14-01/28 u Integrated luminosity s delivered luminosity –week of 01/ pb-1 –week of 01/ pb-1 –luminosity to tape: 40% s major.
ROBOX with Multi Anode PMT’s Status and plans A.Mestvirishvili, I. Schmidt, S. Sen, F. Ozok University of Iowa.
Ursula Bassler, LPNHE Paris1Collaboration Meeting - 13 Sept Calorimeter: Status & Plans Preamp/ Driver Trig. sum Filter/ Shaper x1 x8 SCA (48 deep)
All Experimenters MeetingDmitri Denisov Week of July 7 to July 15 Summary  Delivered luminosity and operating efficiency u Delivered: 1.4pb -1 u Recorded:
18 March 2002 All Experimenters’ Meeting Alan L. Stone Louisiana Tech University 1 DØ Status: 03/11 – 03/18 Week integrated luminosity –1.1 pb -1 delivered.
28 June 2004ATLAS Pixel/SCT TIM FDR/PRR1 TIM tests with ROD Crate John Hill.
The MINER A Operations Report All Experimenters Meeting Howard Budd, University of Rochester June 24, 2013.
MINER A Operations Report All Experimenters’ Meeting Steve Hahn, FNAL July 1, 2013.
S.MonteilCOMMISSIONING1 PS/SPD ELECTRONICS OUTLINE 1)STATUS OF PS/SPD FE BOARDS PRODUCTION 2)PHASES OF PS/SPD COMMISSIONING 1)LEDs AND DETECTORS 2)TUBES.
Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.
Calibration instructions for Quarknet Cosmic-Ray Detector How to Plateau the Counters A friendly guide for students and teachers Edited by Jeremy Paschke,
DØ Calorimeter Software Meeting April 26, Leslie Groer Columbia UniversityCalorimeter Online Software Status + Needs 1  Examines  Crate Unpacking.
1 Calorimeters LED control LHCb CALO meeting Anatoli Konoplyannikov /ITEP/ Status of the calorimeters LV power supply and ECS control Status of.
Status of the PSD upgrade - Problems with PSD in Be runs - Modification of cooling system - New temperature control - Upgrade of HV control system - MAPD.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
DØ Algorithms Meeting April 6, Leslie Groer, Columbia Univ Ursula Bassler, LPNHE, ParisCalorimeter Online Software Status 1  Examines  Crate Unpacking.
HBD Report Craig Woody BNL DC Meeting January 7, 2009.
1 HBD Commissioning Itzhak Tserruya DC meeting, BNL December 13, 2006 Progress from October 3 to November 28, 2006.
LHCf Detectors Sampling Calorimeter W 44 r.l, 1.6λ I Scintilator x 16 Layers Position Detector Scifi x 4 (Arm#1) Scilicon Tracker x 4(Arm#2) Detector size.
Status of MAPMT FEE Electronics Boards Connector board – have 5 boards, 1 assembled Readout board (“MUX” board) – layout completed 12/2, but unfortunately.
1 HBD Update Bill and Ted’s Excellent Adventure T.K. Hemmick for the Wyld Stallions.
May E906 Work and Status TDC readout – One full TDC board, 4 ECL cables/modules KTEV UCLA LV PS – Thanks Dave N.! – +/- 5V, 18A each – Spade /10-12AWG.
June 30th 2008Jacques Lefrancois1 CW base studies Last week June 24th at calo meeting : news that preliminary test done by Yuri Gilitski indicated that.
Preparations to Install the HBD for Run 6 Craig Woody BNL PHENIX Weekly Meeting January 26, 2006.
Piquet report Pascal, Yuri, Valentin, Tengiz, Miriam Calorimeter meeting 16 March 2011.
The ICD Project Alan L. Stone Louisiana Tech University All D0 Meeting - 7 September 2001.
1 Top Level of CSC DCS UI 2nd PRIORITY ERRORS 3rd PRIORITY ERRORS LV Primary - MaratonsHV Primary 1 st PRIORITY ERRORS CSC_COOLING CSC_GAS CSC – Any Single.
Recent Gain Changes C.Woody HBD Meeting March 23, 2010.
E.Gushchin,S.Filippov(INR,Moscow) 16 April 2008Calo commissioning meeting CERN PS/SPD LED monitoring system status General status LED signal is used for.
PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND Doug Roberts U of Maryland, College Park.
The MINER A Operations Report All Experimenters Meeting Howard Budd, University of Rochester Oct 14, 2013.
Current Status of QBPM Electronics and Magnet Movers D. McCormick, J Nelson, G White SLAC S Boogert Royal Holloway Y. Honda, Y.Inoue KEK.
Calorimeter Status Electronics Installation and Commissioning
Calibration Instructions for Quarknet Cosmic Ray Detector
PreShower Characterisations
LKr status R. Fantechi.
PSD Front-End-Electronics A.Ivashkin, V.Marin (INR, Moscow)
Shifter Instructions regarding the ZD, Dan Peterson
Report on ATF2 Third Project Meeting ATF2 Magnet Movers ATF2 Q-BPM Electronics Is SLAC ILC Instrumentation Group a good name?
Presentation transcript:

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University ICD Status High Voltage Changes Invalid Alarms ICD channels in caladdress LED pulser & Taking Runs Calibration Data from Feb 5th Strange behavior of LED Calibration Data from Mar 5th How to proceed next?

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 2 ICD High Voltage Changes High Voltage System conversion by Fritz Bartlett –Global HV GUI will show green (holding) or turquoise (locked state) only when both voltage & current readbacks are within acceptable limits for data-taking Minor alarm state (LO or HI) = yellow Major alarm state (LOLO or HIHI) = pastel red Saturated red color indicates a trip condition while pastel red indicates a major alarm in one or both readback values –Voltages cannot be changed while in locked state HV cannot be raised above V_set value ICD channels have very narrow Voltage limits –Voltages are very stable - PMTs very sensitive to HV change Will need specific interface to deal with LO/HI & LOLO/HIHI alarms for ICD currents –Only I_trip exists at this time

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 3 High Voltage Test Point Drifting ICD HV pods in rack MCH116 provide voltage to 378 PMTs in detector –Not enough money or room for a new rack in MCH for one-to-one pod to PMT matching Use 1:3 adjustable fanout boxes (1 input, 3 output V) –Set pod voltage in GUI in control room –48 test points on front panel of fanout box Safety bar – live voltages  800 V Previously, we used a 1% resistor which was susceptable to moisture which left mineral deposits. This changed the resistance with time, so the test point voltages drifted! Did not affect the voltage received by PMT, but made the modification of voltages very difficult. –48 set screws on each fanout box –  100 V variance Match PMTs to minimize voltage difference between PMT sets Ted Elzroth measured test points – no apparent drift after initial setup in December. Very good news!

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 4 Invalid Alarms Sent to Bill Lee to have the following alarms deleted ICD only uses three of the eight LV modules in the LVPS ICD_LVCP_PW09/12VB ICD_LVCP_PW09/8VC ICD_LVCP_PW09/8VD ICD_LVCP_PW09/8VE ICD_LVCP_PW09/6VH ICD LVPS does not have a magnetic field sensor (sits in rack PW09) ICD_LVCP_PW09/M* These two HV pods are not used (no cables connected - no PMTs in detector) CALS_HVC_SE11 CALS_HVC_SE11/STATE CALS_HVC_SE11/VOLT CALS_HVC_SE11/CURR CALS_HVC_SE12 CALS_HVC_SE12/STATE CALS_HVC_SE12/VOLT CALS_HVC_SE12/CURR These two pods show up as Offline or disabled in the channel HV GUI. Problem over weekend with ICD Preamp row in Supply GUI. What, why & how?

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 5

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 6 ICD channels in caladdress Backplanes of Southwest & Northeast crates have fiber order reversed “accidentally” –Affects only ieta = 12 & 14 –Used RU-106 source to test map Instead of dismounting two 200+ kg crates to fix problem: –Change trigger summers on half of the L-type BLS cards (now L2) –Modify caladdress package for those channels specified as:  = -12  -14 for  = 1-32,49-64  = 12  14 for  = Bob Kehoe modified caladdress last week – need to still verify

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 7 Purpose of LED Runs Long term monitoring of PMT response –The photomultiplier tubes for the Run II ICD sub-detector were recycled from the Run I ICD boxes –Each channel was individually tuned in order to achieve a mean MIP peak on the cosmic ray test stand Only lever arm is the high voltage setting –Over a dozen PMTs have already been replaced About a dozen channels have failed or dropped significantly in gain since the end of the Oct-Nov shutdown –Establish a real world baseline for the full ICD – from scintillator tile to the BLS card Determine correction for channel to channel variation

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 8 The Basics of the ICD LED Pulser Scintillator LED Pulser (SLP) – borrowed from the Muon calibration system –ICD shares VME board with FPD – sits in MCH308 –Accepts external NIM test pulse trigger –VME controlled channel enable, trigger, amplitude and delay Steve Doulas provided the documentation and expertise! Excellent GUI created by Marc Hohlfeld! –DC offset resistively coupled to a TTL signal pulse TTL pulse triggers a transistor which discharges a capacitor into a group of four LEDs DC offset provides the bias voltage for these LEDs

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 9 Taking ICD LED Runs Detailed instructions now part of the Cal Shifters’ Guide (still being fine-tuned) –Needs to be given priority during periods without beam –A baseline still needs to be determined What is the optimum delay time (between 0 and 170 ns)? What DC offset(s) should be used? –The turn-on voltage as seen on the oscilloscope directly from the electronics is about 6.6 Volts. The LED pulser needs to be issued a command to turn off during the prepare-for-run-1.2 download –There is currently no alarm to check that the ICD LED pulser is off during global data-taking Bill Lee & Ulla Blumenschein working on this

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 10 > setup d0online > cd /home/d0icd/vme >./lmb_int.py & More on LED Pulser Runs  Voltage is adjustable up to 10.0 Volts in increments of 0.2 Volts  Delay is adjustable from 0 to 170 ns in increments of 2 ns  All Download is preferable – Read feature sets ALL to zero  The only way to turn off the pulser is to set ALL (voltage & delay) to zero - then click on Read - all fields should be 0.0 or 0!

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 11 Last time... Stephanie Beauceron took the full set of runs (six DC offsets at six different time delays) on Feb 6 th ! –Too much work – need to reduce the number of steps –hbook saved files very useful to make plots/printouts offline From the spreadsheet, I was able to make plots for each channel (ADC counts vs DC offset and delay time) –Choose a delay time so the signal is sampled at or near the peak Ted Elzroth determined ADC count value for one good channel from each Cal Crate in which the ICD is part of the readout - [Crates 0,1,4,5,6,7,10,11]. Did this for each DC offset & time delay setting – 8  6  6 = 288!

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 12 ICD-CAL Preamp/BLS Signal Shape

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 13 ICD Beam Signal

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 14 All ICD channels in Cal Crates 10 & 11 readout

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 15 ICD in Cal Crate 0

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 16 ICD in Cal Crate 11

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 17 LED Pulser Runs There is a difference in the timing between East/West –180 feet SLP cable on East & 210 feet on West SLP maximum delay is 170 ns –All channels are coming in very early West appears to be near maximum, but East is even earlier Dean added 130 ns delay to the trigger (both preamp and LED pulser) –This shifts the scale adding another 140 ns of delay range Dropped two of the six DC offsets from the LED pulser runs

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 18 Something Strange Happened... Florian Beaudette took ICD LED pulser runs on owl shift of February 22 –4 DC offsets (7.8, 8.2, 8.6, 9.0) & 6 Delays (0,10,20,30,40,50) –Wrote script renamehbk which changes cal_elec default hbook name to include DC offset & delay time Next owl shift, Florian noticed that most of the ICD cells had about -1 GeV. –He looked in the crate_all_bad.txt file, noticing most of the cells reported were ICD Both Florian, and the next shifter, Lee Sawyer, checked: –Pulsers (preamp & LED) were off & LV/HV was OK –redownloaded cal_prepare_for_run-1.2

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 19 More strange behavior I looked at the hbook files on Feb 24th –only 2 of the 24 runs had signal - the rest showed only pedestal for all channels The 2 with signal were at the same DC offset at 40 & 50 ns delay Despite the LED pulser GUI reading all zeroes, it seemed the SLP card was still sending signals! –Ran cal_elec: all ICD channels were firing as one would expect if the LED pulser was on –I disconnected two of the four SLP cables - half of the ICD signals returned to pedestal (as seen in cal_elec) –The only immediate solution (we were in shot set-up) I disconnected all SLP output cables from the SLP card in M308 –Mingcheng & Bernard took new pedestals - ICD channels looked normal again (eve of Feb 24th)

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 20 Fixing ICD LED Pulser I cannot explain it! Eve of Feb 27th, I reconnected the SLP output cables –Dean & I looked at the VME page and LED GUI Nothing unusual - I described my tests in detail in the logbook –I took several separate cal_elec runs, using different DC offsets & delay times - the SLP did not “lock-up” What have we learned: –Shifters hesitate TOO LONG to page expert (generalization) During physics data taking – Always fix problem ASAP! – s and Logbook entries are not enough! –Need for a NEW dedicated person to become ICD expert I will help as much as I can…

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 21 Calibration Data from March 5th Ulla took fourteen runs: fixed DC offset of 8.6 V –delay time from ns in increments of 10 ns L3/DAQ work prevented her from going to 170 ns –Took about two hours Primarily interested in optimizing delay time –What was the effect of Dean shifting trigger by 130 ns? To verify the SLP did not “lock” in one state –Ulla ran a new cal_elec_ICD & looked at a few channels to watch for small changes from run to run I took this step out after Stephanie tried the procedure, to make it easier - if this had been left in, I think Florian would have noticed a problem, so I will keep it from now on Ted looked at the hbook files & created a spreadsheet

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 22

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 23

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 24

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 25

12 March 2002 Calorimeter Software Mtg Alan L. Stone Louisiana Tech University 26 What Steps should we take next? Less than 2% difference between min/max ADC count value for West channels between 10 & 130 ns delay East is still early - increase of 6-8% in ADC count value from 10 ns to 130 ns delay –Add cable to East? Or take separate runs for East & West? Continue to remove the “black-box” treatment of ICD –Suggestions? Documentation is up-to-date. 44 New PMTs arrived – a gift from Heidi and Dean - will ship to UTA for testing by Kaushik et al. (?) –Have commitment for tested PMTs at D0 by May 1st –Tentative plans: 2 week access in late May/early June & 4-5 week shutdown beginning in August detector will open both times, so bad/marginal PMTs can be replaced