The School of Forest Resources Building Aquaculture Lab Lighting Layouts Chris Hoyman Dr. Mistrick, Faculty Advisor February 3, 2006.

Slides:



Advertisements
Similar presentations
EGEE 102 – Energy Conservation And Environmental Protection Energy Efficient Lighting.
Advertisements

LAMPS (Chapter 3) Lamp efficacy, life, and color Incandescent
Lighting Tax Deduction The Energy Efficient Commercial Buildings Tax Deduction.
Professor Mark A. Comeau, AIA © Interior Environment Week 9 Lighting: High efficiency Day-lighting Occupancy & daylight sensing, programmable operations.
Technology in Architecture Lecture 4 Lighting Design Example Lecture 4 Lighting Design Example.
The Franklin Care Center Addition and Renovation Franklin Lakes, New Jersey Jennifer Curley Lighting/Electrical Option Faculty Advisor: Dr. Moeck.
Emerging Lighting Technologies Roundup
Management and Organisation of Electricity Use Energy Efficient Lighting Techniques Belgrade November 2003.
Thesis Presentation April 13, 2004 Brian Regan The Virginia Historical Society Building Lighting/Electrical.
Hall Corporate Headquarters Dan Rusnack Tuesday April 13 th, 2004 Lighting/Electrical Emphasis Thesis Presentation Thesis Presentation.
Lighting Fixtures and Bulbs Mrs. Molino Interior Design.
Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.
Lighting Calculations
Why BoldPlay? Brilliant Design. Intuitive Engineering Innovation + Design = Performance Serious Energy Savings Ideal direct/indirect distribution maximum.
Building Statistics Owner – Dansko, Inc. Owner – Dansko, Inc. Manufacturer of shoes sold in over 3500 stores in the US and Canada Manufacturer of shoes.
1) This classroom has _______. A)Too much lighting B)Not enough lighting C)About the right amount of lighting.
1. 2 Low profile, High performance 3 Key Features Up-to 108 lm/w Ultra wide row spacing Module lengths of 4’, 8’ and new 6’ Suspended and wall Mount.
R e n e w a b l e E n e r g y E d u c a t i o n L e s s o n 4 ENERGY CONSERVATION J E O P A R D Y Unit 4: Energy Conservation: Here, There, Everywhere.
Lighting Dr. Vivian G. Baglien. Natural Light First light source to consider. Sunlight that enters the house through windows, doors, skylights, etc. North.
Lighting In Interior Design. 1. Facts about Lighting….. Lighting manipulates the mood or feeling of any interior Lighting can alter responses from the.
Lighting Interior Design II. Natural Light Provided by the sun Makes color sharper and brighter Generates a feeling of well being.
Bowie State University Fine and Performing Arts Center Zachary Lippert Faculty Advisor: Dr. Stephen Treado.
HOUSING DECISIONS p How are these mounted? Which way do they direct light? Valance lighting Bracket lighting Recessed down lights Surface mounted.
Thesis Presentation April 13, 2004
George Mason University Art & Visual Technology Building Allen Walker Schematic Design Phase George Mason University Art & Visual Technology Building.
Schematic Design Proposal Dan Rusnack 11/14/03 Lighting/Electrical option Thesis project The Hall Corporate Headquarters.
Artificial Lighting Design Task lighting for general purpose rooms involves the installation of light sources that will provide the optimum amount of.
Wegmans Fairfax Schematic Design Joseph Lookup The Pennsylvania State University 5 th Year - Architectural Engineer Lighting/Electrical.
FLUORESCENT LUMINAIRES Fluorescent Luminaires U.S. Department of Energy Rebuild America Business Partners And Lithonia Lighting.
Background Design Concept Gallery Lecture Hall (acoustics) Meeting Room Conclusions The Bahen Centre for Information Technology Spring 2003 Senior Thesis.
Senior Thesis Presentation: The Westlake Recreation Center Summer Padgett Faculty Advisor: Dr. Mistrick Westlake Recreation Center Westlake, Ohio Electrical.
Solid State Lighting July 1, Overview Basics Review Potential SSL Measures & Applications Scale of Conservation Potential Initial Cost-Effectiveness.
Solution Profile LED Light Bars Outshine Fluorescents, Reduce Machine Build Times & Expenses.
Southeast View of IRMC West View of IRMC. Presentation Outline Introduction Existing Structure Thesis Goals Structural Depth Lighting Breadth Conclusion.
The Dubois Educational Foundation Workforce Development & Technology Building Josh Lutton Lighting/Electrical Option.
ACOSHAPE Acoustic Lighting Case Study Document. Requirements General school areas such as; meeting rooms, offices, libraries and classrooms have to reach.
Howard County General Hospital
Arlington National Cemetery Renovation Show Building Overview Picture My name Date.
Circuits Series & Parallel.
Slide: 1 Sync ™ with MesoOptics. Key Features Slide: 2 Sophisticated low-profile look that accommodates T5, T5 HO and T8 True Direct/Indirect performance.
Thesis Lighting Design Proposal Dan Rusnack 12/9/03 Lighting/Electrical option Senior Thesis project Hall Corporate Headquarters.
Chapter 8 Quantity of Lighting © 2006 Fairchild Publications, Inc.
Schematic Lighting Design Natty Boh Building Baltimore, Maryland Eric Singley Penn State University Architectural Engineering.
Howard County General Hospital Schematic Design Proposal Casey Schardt.
Howard County General Hospital
Because spaces come in all shapes and sizes.... Key Features Slide: 2 Highly versatile – Voice works in almost any building and adapts to almost any architectural.
Dorrance H. Hamilton Building
The School Of Forest Resources Building University Park, Pennsylvania Chris Hoyman The Pennsylvania State University Architectural Engineering Lighting/Electrical.
Objectives Learn about lighting design.
North Hills Junior High School Schematic Lighting Design
Schematic Lighting Design Natty Boh Building Baltimore, Maryland Eric Singley Penn State University Architectural Engineering.
North Hills Junior High School Pittsburgh, PA Senior Thesis Final Presentation 2005 Chris Rush Lighting / Electrical Faculty Consultant: Dr. Mistrick.
Newseum and Freedom Forum Headquarters Washington, D.C. Ryan Wise Lighting/Electrical Option Consultant: Dr. Mistrick Dec. 14, 2007.
Senior Thesis Presentation: The Westlake Recreation Center Summer Padgett Faculty Advisor: Dr. Mistrick Electrical / Lighting Option April 13th, 2004.
Cost of lighting Facts $14B in Rate Freezes expiring now National Average nearing 10¢ kwh Lighting Represents % of Utility Bills Investment required.
Lighting CHS Interior Design.
Incandescent Light Bulb LUMEN DESIGN METHOD Where: N = E A F UF LLF N = number of lamps E = level of illuminance A = Area at working plane.
Nonresidential Lighting Alterations
frost theater building
Night of Lighting Housing I Objective 4.05.
Greenwich Academy Upper School
Fixtures and Bulbs Mrs. Molino Interior Design
Lighting Objective /13/2018.
Greenwich Academy Upper School
Point-by-Point Factors
Technology in Architecture
Objectives Learn about lighting design.
Announcement Filed trip is on Monday, May 6th from 8 to 9 AM
Announcement Next class: 15 minutes quiz
Objectives Finish Lighting system design Daylighting.
Presentation transcript:

The School of Forest Resources Building Aquaculture Lab Lighting Layouts Chris Hoyman Dr. Mistrick, Faculty Advisor February 3, 2006

Overview The first space chosen for redesign was the Aquaculture Lab located in the basement. An analysis of the general room lighting was performed. Lights in the individual tanks are controlled centrally from a dimming panel with a day/night cycle setting.

Overview The original design, pictured here, used suspended linear fluorescent downlight fixtures, with no drop ceiling. For the redesign, I applied two new systems along with a drop ceiling.

Overview In applying the drop ceiling, I hope to create a brighter, more uniform looking space. Hiding the currently exposed piping will give the room a cleaner look as well. With the increased reflectance off the drop ceiling tiles it may be possible to reduce the overall number of fixtures in the room (saving on fixture and energy costs).

Original Design Original design featured 18 suspended fluorescent fixtures –Two 32W T8 bulbs each –59W Input for two lamp ballast, 18 total –1062W total over an are of 760 sq. ft. –Power Density = 1.4 sq. ft.

Original Design

New Design- Suspended New design features 15 suspended fluorescent fixtures with a drop ceiling –Two 28W T5 bulbs each –63W Input for two lamp ballast, 15 total –945W total over an are of 760 sq. ft. –Power Density = 1.24 sq. ft.

New Design- Suspended

New design useless less energy, fewer fixtures, has lower Avg./Min. and Max./Min. ratios, and creates a more comfortable space.

New Design- Recessed New design features 15 recessed fluorescent fixtures with a drop ceiling –One 54W T5 bulb each –62W Input for one lamp ballast, 15 total –930W total over an are of 760 sq. ft. –Power Density = 1.22 sq. ft.

New Design- Recessed

New design useless less energy, fewer fixtures, has lower Avg./Min. and Max./Min. ratios, and creates a more comfortable space.

New Design Both new designs performed better than the existing, however the suspended system yields higher illumination and better uniformity for only a small increase in power density. The suspended system with the drop ceiling was chosen for the final design.

Light Loss Factors LDD- suspended- Category II, very clean environment, 12 month cycle, LDD=0.97 LDD- recessed- Category IV, very clean environment, 12 month cycle, LDD=0.94 LLD- suspended- 2697/2900=0.93 LLD- recessed- 4650/5000=0.93

Light Loss Factors RSDD-suspended- 7% expected dirt depreciation, Direct/Indirect, RCR= 3.1 (H=8’), RSDD= 0.94 from table RSDD-recessed- 7% expected dirt depreciation, Direct, RCR= 3.9 (H=10’), RSDD= 0.97 from table

Suspended System- Circuits 63W/ fixture * 15 fixtures= 945 W Power factor = W / 0.99 pf = 955 VA 955 VA / 277V = 3.45 A 16A limit, only one circuit needed

Suspended System- Switching General lighting in the room is for the occupants only, during observation and experiments. Dimming on this lighting is not required. For some flexibility of light levels, and potential energy savings, each row of lights (in the longer direction) will be switched together. In this manner the two outer rows could be on leaving the middle row off if desired (see next slide).

Suspended System-Switching

Notes This space is not going to be one of the photo quality rendering spaces I complete for the final submission All AGI files, cutsheets, and assorted information are available on my P Drive, under thesis/aquaculture.