3200 Electrical Test Equipment Calibrator The Total Solution to Electrical Test Equipment Calibration.

Slides:



Advertisements
Similar presentations
Digital Current Transformer Reporter
Advertisements

CABLE FAULT ANALYSIS BY UTMANCO SYSTEMS (P) LTD. What is a Fault ? DEFECT WEAKNESS INCONSISTENCY OR NON- HOMOGENEITY THAT AFFECTS THE PERFORMANCE OF THE.
Electrical Installation
imnot50 and suite4121 The form of protection provided by the insulation of live parts would be: Protection against direct contact.
Understanding GFCIs Developed by NEMA Ground Fault Personnel Protection Section (5PP) Developed by NEMA Ground Fault Personnel Protection Section (5PP)
Potentiostat Basics I’m Max Yaffe
Inspection & Test Overview suite412.
30th Nov 2005Imnot50 Question 1 State the necessary action that should be taken by an inspector on discovering a damaged socket outlet with exposed live.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
EET Electronics Survey Chapter 8 - Measuring Voltage, Current, and Resistance.
The Association of Electrical and Medical Imaging Equipment Manufacturers Understanding GFCIs Developed by the NEMA 5PP Personnel Protection Technical.
Electrical Safety Testing of Electrical Installations and the verification of Electricians Test Tools Michael Bailey Transmille Ltd NCSLi 2014Transmille.
PRACTICAL ELECTRONICS MASTERCLASS (Mr Bell) 1. Fault finding A fault is when a piece of equipment does not work the way it had been intended too. Fault.
Circuit Protection Electrical circuits require protection to prevent fire or electrocution in the event of a fault. There are two main types of circuit.
Safety Testers (plus more) from Dranetz and Gossen Metrawatt General Presentation.
3200A Electrical Test Equipment Calibrator. Automatic Loop Correction To simplify calibration of loop testers, the 3200A can be fitted with the Auto.
3200A Options / Technical Overview. 3200A Electrical Test Calibrator Innovative design to bring advances in technology to the calibration of Electrical.
Why do wires get hot when a current passes through them?
INSULATION TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
Area of Study 2: Electricity
Electrical Safety Mark Gough Electrical Inspector Northern Specialist Group.
Electricity at Work.
Unit 201: Health and safety in building services engineering
Electricity Current Voltage Resistance Current, Voltage, Resistance characteristics AC DC Plugs Earth Fuses Power.
PROEDIT WRITING A PROCEDURE USING THE BUILT-IN PROCEDURE WIZARD.
Phase Presence and Sequence Tester (FAST-1) Boris Fradkin 2015 A.L.F. Enterprise.
RCD TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
CHAPTER 6 EARTHING SYSTEM.
20.3 Electric Circuits
MAINS ELECTRICITY. Specification Electricity Mains electricity understand and identify the hazards of electricity including frayed cables, long cables,
Lesson 6 Voltage Do we need to MEASURE it? OR Do we need to DETECT it?
 “A multimeter is an instrument designed to measured electric current, voltage and usually resistance, typically over several ranges of value”.
ADT490 Panel Theory. 2 System Power Supply Grounding ‣ Circuit separates positive / negative from Ground ‣ Ground fault - resistance to ground ≤ 10 kΩ.
Electricity It’s Shocking!!. Current Electricity Current Electricity is a constant flow of electrons through a circuit. There are three main parts to.
Grounding.
PAT TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
Electrical Current and Circuits How Electricity Gets To Where It Is Going.
Main contacts closed – RED Colour with ON
Testing of Low Voltage Installations
LOOP TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
Self Switching Power Supply. Introduction Self Switching Power Supply  Embedded system requires a regulated power supply.
Electrical Circuits Chapter 20 Section Three. Science Journal Entry #42 Expound upon Ohm’s Law and its relationship to current, resistance, and voltage.
Direct current Cells and batteries supply electric current which always flows in the same direction. This is called direct current (d.c.). Direct current.
LOCATION OF CABLE FAULTS
By: 47.M.B.J.Varma 48.Mallikarjuna Abhilash 49.Maraka Kulateja 50.Prajakta Mategadikar 51.Medepalli Nikhil Raj.
Current Transformer Testing
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
Introduction High Voltage!!.
PROTECTION AGAINST INDIRECT CONTACT
THREE PHASE FAULT ANALYSIS WITH AUTO RESET ON TEMPORARY FAULT AND PERMANENT TRIP OTHERWISE Submitted by:
Grounding.
Electrical Safety Describe and explain how a fuse works as safety device. Describe and explain how a circuit breaker works as a safety device. Explain.
Starter Review your filament lamp experiment and make corrections (in green pen) Review your test and complete the front cover sheet, correct any mistakes.
GROUND-FAULT GROUND-CHECK MONITOR
HVI HIPOT TEST SET Pft sERIES.
Effects of an Electric Current and Domestic Circuits
Electrical Safety in the Home
Calculating the maximum allowable earth fault loop impedance.
What Is to Be Covered? Electrical Shock - Why Have GFCIs?
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
MAINS ELECTRICITY.
Electrical components and systems
Electrical components and systems
Electrical components and systems
Electronics Current Practice Problems LabRat Scientific © 2018.
724 Temperature Calibrator
Presentation transcript:

3200 Electrical Test Equipment Calibrator The Total Solution to Electrical Test Equipment Calibration

3200 Electrical Test Equipment Calibrator – Five Calibrators In One Calibrates…  INSULATION TESTERS  RCD TESTERS  LOOP TESTERS  PORTABLE APPLIANCE TESTERS  HIPOT / BREAKDOWN TESTERS

3200 Electrical Test Equipment Calibrator – Insulation Tester Calibration Calibrating Insulation testers with the 3200 is simple. All the functions required are in one instrument, making calibration fast and simple. Use with ProCal software to automate and save even more time.  Insulation Resistance from 100kohms to 10Gohms at 1kV  Measurement of Insulation Test Voltage at 1mA load  AC Voltage Calibration to 400 Volts  Continuity Resistance from 0 to 1kohms  Continuity Resistance Current to 300mA Measured into 1ohm

3200 Electrical Test Equipment Calibrator – RCD Tester Calibration Residual circuit breaker testers are designed to test and measure the break time of AC mains (RCB) trips at set test currents. Fault current is allowed to pass between live phase and earth. The ‘fault’ current is started by pressing a button on the tester, usually an LCD counter on the tester measures the time in milliseconds until the mains supply is disconnected. The 3200 has been specially designed to make the calibration of RCD testers safe & straight forward, which can otherwise be quite difficult and even dangerous. To calibrate an RCD tester, it is necessary to measure the current taken from the mains supply by the tester on each of its ranges and the time period measured shown on the testers display to the disconnection of supply. The 3200 can calibrate both functions. Intelligent firmware measures the correct fault current ignoring pre-test currents from testers such as the AVO CM500. The 3200 also provides accurate timed disconnection of the supply to verify the testers timing accuracy. Some RCB testers have additional functions such as which half cycle of the mains the fault current started, fault current duration etc. which can also be tested by the 3200.

3200 Electrical Test Equipment Calibrator – Loop Tester Calibration To calibrate a Loop Tester simple connect to the 3200, select the loop function and run auto loop. Select the required loop value on the 3200 and press test. The 3200 automatically checks for a faulty loop tester before applying the full mains supply.  Automatic Measurement and compensation of supply loop impedance  Automatic detection of faulty Tester preventing damage to 3200  8 loop values from 0.05ohm to 1kohm.

3200 Electrical Test Equipment Calibrator – PAT Calibration There are several different measurement functions to be calibrated on a PAT tester. The functions required are all in the 3200 ensuring fast and efficient calibration of these instruments.  Earth Bond Resistance  Earth Bond Current Measurement to 30 Amps  Insulation resistance from 1M to 10Gohms  Leakage Current Measurement  Class 1 & 2 Flash Voltage Measurement

3200 Electrical Test Equipment Calibrator – HIPOT / Breakdown Tester Calibration  3kV & 12kV AC/DC Measurement Ranges  200uA 2mA 20mA Current Ranges  200uA : 5M  10M  20M  Loads  2mA : 500k  1M  2M  Loads  20mA : 50k  100k  200k  Loads  Current ranges : 1kV maximum  Power On & Overload Indicators  Requires 3200 Calibrator VOLTAGE MEASUREMENT  Connects between ground and appropriate voltage terminal  Select voltage range (3kV / 12kV AC/DC) and read back the voltage measured from the display of the CURRENT LOAD  Three electronically selectable ranges, nine current loads Select current range using the 3200 ‘softkeys’  Connect breakdown tester between ground and the appropriate resistor socket.