1 International Federation for Consulting GmbH IFC Method Validation and QC for Pesticide Residue Analysis SANCO/2007/3131 by Dr. Michael Scheutwinkel.

Slides:



Advertisements
Similar presentations
Supplementary Training Modules on Good Manufacturing Practices
Advertisements

LABORATORY CERTIFICATION & DATA QUALITY MICHAEL W. MILLER, Ph.D. NJ-DEP Office of Quality Assurance
An Introduction to Quality Assurance in Analytical Science
Instrumental Analysis
UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc.
1 Method Selection and Development l Initial Considerations n What does the method need to do? 3 What analyte/s need to be assayed? 3 What range or concentration.
THCA in Head Hair: A Comparison with Fingernail. Conflict of Interest  Employees of USDTL Privately held company Commercial laboratory Sells hair testing.
The New TNI Laboratory Accreditation Standards Requirements for an Accreditation Body.
Florida Pilot Initiative for the Performance Approach to Measurement Systems Stephen Arms Florida Department of Health.
Pesticide screening LC-QTOF, Agilent. National Food Institute, Technical University of Denmark Disposition National Food Institute –EURL –NRL –Personale.
Spring in the Bridger Mountains. MONTANA: METHOD SELECTION AND VALIDATION Lab Accreditation Meeting San Diego, March 10 th.
World Health Organization
Training Workshop on Pharmaceutical Development with a Focus on Paediatric Medicines / October |1 | Pharmaceutical Development Analytical.
MFRPS 10 Laboratory Support: Relationship to the Sampling Agreement Requirement Steven M. Sobek Director - Bureau of Laboratory Services State of Wisconsin.
FEDERAL PUBLIC SERVICE (FPS) HEALTH, FOOD CHAIN SECURITY AND ENVIRONMENT 1 Validation of confirmatory methods for MRPL and MRL substances in matrices of.
Accreditation & Validation
Validation Part 2: Cleaning validation
Copyright © 2015, TestAmerica Laboratories, Inc. All rights reserved. 1 EPAs New MDL Procedure What it Means, Why it Works, and How to Comply Richard Burrows.
Supplementary Training Modules on Good Manufacturing Practice
Control charts Pharos University. An internal system for quality control is needed to ensure that valid data continue to be produced. This implies that.
Kyiv, TRAINING WORKSHOP ON PHARMACEUTICAL QUALITY, GOOD MANUFACTURING PRACTICE & BIOEQUIVALENCE Validation of Analytical Methods Used For Bioequivalence.
Chemometrics Method comparison
Lecture 7 Analytical Quality Control
Validation of Analytical Method
Dr. Michael Scheutwinkel
Introduction to Analytical Chemistry
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
Analytical considerations
Introduction to Analytical Chemistry Dr M. Abd-Elhakeem Faculty of Biotechnology General Chemistry Lecture 7.
Quality WHAT IS QUALITY
How to Select a Test Method Marlene Moore Advanced Systems, Inc. June 15, 2010.
OFFICIAL FOOD CONTROL IN AUSTRIA Franz VOJIR Federal Ministry of Health and Women Vienna, Austria.
1 International Federation for Consulting GmbH IFC Validation on the basis of Commission Decision 2002/657/EC by Dr. Michael Scheutwinkel.
1 Exercise 7: Accuracy and precision. 2 Origin of the error : Accuracy and precision Systematic (not random) –bias –impossible to be corrected  accuracy.
Prof. Dr. Magdy M. Saad Food Safety Dept., NRC, Egypt.
MPA requirements on validation of bioanalytical methods The analytical method should be validated before analysing of specimens from GLP and GCP studies.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Metrology for Chemical Analysis
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 1 Learning.
Industrial Technology Institute Test Method Validation & Verification H.P.P.S.Somasiri Principal Research Scientist / SDD-QAD /QM Industrial Technology.
Control Charts and Trend Analysis for ISO 17025
Is it Method Validation, Verification or or Just Semantics?
Control Charting Mississippi Style ASHLI BROWN, GALE HAGOOD, DONGPING JIANG MISSISSIPPI STATE CHEMICAL LABORATORY GOVERNMENTAL FOOD AND FEED LABORATORIES.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
International Office for Water B. Fribourg-Blanc, WG-E (6), Brussels, 6/7/2009 slide 1 Agenda Item 5 : (a) Data collection, associated data treatments.
= the matrix for T relative to the standard basis is a basis for R 2. B is the matrix for T relative to To find B, complete:
Copyright © 2015, TestAmerica Laboratories, Inc. All rights reserved. 1 EPAs New MDL Procedure What it Means, Why it Works, and How to Comply Richard Burrows.
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
Workshop Method Validation in Analytical Sciences Current practices and future challenges Gent, 9-10 May 2016 Report from WG 4.
QUALITY REQUIREMENTS FOR OFFICIAL FOOD LABORATORIES WITHIN EURL AND NRL (LABORATORY NETWORKS IN EUROPE) dr. Tina Pirš, dr. vet. med. Quality Manager, Veterinary.
Validation of the AOAC method for pesticides residues analysis in oranges and mandarins in LATU Marina Torres (1) 1, Lucía Alcarraz 1 (2) 1 Laboratorio.
SEMINAR ON PRESENTED BY BRAHMABHATT BANSARI K. M. PHARM PART DEPARTMENT OF PHARMACEUTICS AND PHARMACEUTICAL TECHNOLGY L. M. COLLEGE OF PHARMACY.
ÚKZÚZ - NRL RO Praha1 COMMISSION REGULATION (EC) No 152/2009 of 27 January 2009 laying down the methods of sampling and analysis for the official.
Method Validation of VINDTA 3C (TA/DIC) Marine Scotland Science (MSS) Experience and Concerns Pamela Walsham.
Maximum residue limits on agrichemicals
Challenges in Method Validation – A Regulatory Laboratory Perspective
Multi-Analyte LC-MS/MS Methods – Best Practice.
On behalf of Jerry Parr, Executive Director, TNI
The 2015/2016 TNI Standard and the EPA MDL Update
EPA Method Equivalency
Workshop Method Validation in Analytical Sciences Current practices and future challenges Gent, 9-10 May 2016 Report from WG 1 Day2.
An Introduction to Quality Assurance in Analytical Science
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
METHOD VALIDATION: AN ESSENTIAL COMPONENT OF THE MEASUREMENT PROCESS
Режа: 1. Метрология тушунчаси 2. Валидация
IMPLEMENTING DIRECTIVE 2000/60/EC CONCERNING MINIMUM PERFORMANCE CRITERIA FOR CHEMICAL MONITORING METHODS AND THE QUALITY OF ANALYTICAL RESULTS via a.
Draft concept to assess quality of monitoring database
Quality assessment of the monitoring database on priority substances
Agenda Item 6: Review of the list of priority substances (Decision 2455/2001/EC) EAF(9)-06/02/INERIS - Data processing - preparation for data collection.
Օրենսդրական բացերը ընդերքօգտագործման ոլորտում
Presentation transcript:

1 International Federation for Consulting GmbH IFC Method Validation and QC for Pesticide Residue Analysis SANCO/2007/3131 by Dr. Michael Scheutwinkel

2 Outline - This SANCO paper applies for all governmental laboratories and those private ones working in the official food control. - Accreditation Bodies are using this paper as basis for validation and quality control. SANCO/2007/3131

3 Calibration…. -representative analytes for each bach of analyses -all substances at least every 3 months At least 15 analytes + 25% of total number of analytes (100 analytes = 40 components) At least 15 analytes + 25% of total number of analytes (100 analytes = 40 components) SANCO/2007/3131

4 Calibration…. -Matrix matched … - Grouping of food stuff … The most effective way to negate matrix effects is to calibrate with standard addition. The most effective way to negate matrix effects is to calibrate with standard addition. SANCO/2007/3131

5 Validation Model List of all pesticides analysed in routine List of all pesticides analysed in routine Repeatability Recoveries, 70 – 120 % Recoveries, 70 – 120 % LOD‘s /LOQ in different types of matrix reproducibiity LOD‘s /LOQ in different types of matrix reproducibiity Reproducibility Pesticide concept Which pesticide is detected how? Which pesticide is detected how? Fulfilment of legal requirements Fulfilment of legal requirements