Feedback Control Systems Dr. Basil Hamed Electrical Engineering Islamic University of Gaza.

Slides:



Advertisements
Similar presentations
Chapter 5 – The Performance of Feedback Control Systems
Advertisements

Nise/Control Systems Engineering, 3/e
Chapter 4 Continuous Time Signals Time Response Continuous Time Signals Time Response.
Feedback Control Systems Dr. Basil Hamed Electrical & Computer Engineering Islamic University of Gaza.
Chapter 10: Frequency Response Techniques 1 ©2000, John Wiley & Sons, Inc. Nise/Control Systems Engineering, 3/e Chapter 10 Frequency Response Techniques.
Frequency Response Techniques
Lect.7 Steady State Error Basil Hamed
Feedback Control Systems
Chapter 8 Root Locus <<<4.1>>>
4.3. Time Response Specification in Design
Chapter 5 – The Performance of Feedback Control Systems
Feedback Control Systems
Transient and steady state response (cont.)
Feedback Control Systems
Transient & Steady State Response Analysis
Lecture 9: Compensator Design in Frequency Domain.
Modern Control Systems (MCS)
Review last lectures.
ECE Introduction to Control Systems -
PID Control and Root Locus Method
Out response, Poles, and Zeros
Feedback Control Systems (FCS) Dr. Imtiaz Hussain URL :
Combined State Feedback Controller and Observer
Lect.5 Reduction of Multiple Subsystems Basil Hamed
Automatic Control System
سیستمهای کنترل خطی پاییز 1389 بسم ا... الرحمن الرحيم دکتر حسين بلندي- دکتر سید مجید اسما عیل زاده.
It is the time response of a system to an input that sets the criteria for our control systems. Many quantitative criteria have been defined to characterise.
NUAA-Control System Engineering
Automatic Control Systems
1 Chapter 11 Compensator Design When the full state is not available for feedback, we utilize an observer. The observer design process is described and.
Performance of Feedback Control Systems. Test Input Signals:
Chapter 10 Frequency Response Techniques Frequency Response Techniques.
Modern Control System EKT 308 Steady-State and Stability.
System Time Response Characteristics
1 Time Response. CHAPTER Poles and Zeros and System Response. Figure 3.1: (a) System showing input and output; (b) Pole-zero plot of the system;
Overhead Controller Design Project Name Department and University Date Class Name.
1 Steady-State Error M. Sami Fadali Professor of Electrical Engineering University of Nevada.
Control Systems Engineering, Fourth Edition by Norman S. Nise Copyright © 2004 by John Wiley & Sons. All rights reserved. Figure 10.1 The HP 35670A Dynamic.
Intelligent Robot Lab Pusan National University Intelligent Robot Lab Chapter 7. Forced Response Errors Pusan National University Intelligent Robot Laboratory.
Control Systems Lect.3 Steady State Error Basil Hamed.
SKEE 3143 Control Systems Design Chapter 2 – PID Controllers Design
Signals and Systems, 2/E by Simon Haykin and Barry Van Veen Copyright © 2003 John Wiley & Sons. Inc. All rights reserved. Figure 9.1 (p. 664) Two different.
Lecture 7/8 Analysis in the time domain (II) North China Electric Power University Sun Hairong.
Feedback Control System THE ROOT-LOCUS DESIGN METHOD Dr.-Ing. Erwin Sitompul Chapter 5
Chapter 12 Design via State Space <<<4.1>>>
Automatic Control Theory CSE 322
Youngjune, Han Chapter 4 Time Response Youngjune, Han
Time Response Analysis
Design via Root Locus (Textbook Ch.9).
Control Systems (CS) Lecture-12-13
Chapter 9 Design via Root Locus <<<4.1>>>
Islamic University of Gaza Faculty of Engineering
Time Response System & Control Engineering Lab.
UNIT-II TIME RESPONSE ANALYSIS
Frequency Response Techniques
Compensators.
Frequency Response Techniques
UNIVERSITI MALAYSIA PERLIS SCHOOL OF ELECTRICAL SYSTEM ENGINEERING
Root Locus Techniques CH 8: Islamic University of Gaza
Chapter 4. Time Response I may not have gone where I intended to go, but I think I have ended up where I needed to be. Pusan National University Intelligent.
Lecture 6: Time Domain Analysis and State Space Representation
Root Locus Techniques CH 8: Islamic University of Gaza
B.Tech – II – ECE – II SEMESTER ACE ENGINEERING COLLEGE
Frequency Response Techniques
Chapter 5 – The Performance of Feedback Control Systems
Time Response, Stability, and
Exercise 1 For the unit step response shown in the following figure, find the transfer function of the system. Also find rise time and settling time. Solution.
Control System and Transfer Function
By: Nafees Ahamad, AP, EECE, Dept. DIT University, Dehradun
The Frequency-Response Design Method
Presentation transcript:

Feedback Control Systems Dr. Basil Hamed Electrical Engineering Islamic University of Gaza

Time Response

Problem In Ch. 4 (p. 212) Ships in turbulent seas incur motion about their roll axis. Stabilizing fins, which can be positioned by a closed-loop control system, can be used to reduce this motion. Components describing this system include fin actuators, sensors, and roll dynamics.

Transfer Function

Using MATLAB do the following A)Find the natural frequency, damping ratio, peak time, settling time, rise time, and percent overshoot. B) Find the analytical expression for the output response to a unit step input in voltage. C) Plot the response found in (B).

Part A

Part A From these pole locations the two quantities describing the transient response of this second-order system are found

Part A

Part B Using partial fraction expansion and unit step input, the Laplace transform of the response θ(s) is: A = 1, B=0.1, C = 0.5

Part C

Animation

Problem 2

PROBLEM DEFINITION Most manufacturing welding situations involve many uncertainties, including dimensions of the part, joint geometry, and the welding process itself. To ensure weld quality, sensors are therefore necessary. Some such systems, as described by Figure 1, use a vision system to measure the geometry of the puddle of melted metal. Here, it is assumed that the rate of feeding the wire to be melted is constant

Block Diagram of the System

Using MATLAB do the following A.Determine a second-order model for the closed-loop system. B.Find the overshoot and peak time of the system with gain K = 10 using both the second-order model and original system, then compare the results. (Assume a step input.) C.Using the second-order model, select a gain K so that the settling time is less than 4 seconds and the peak time is less than 5 seconds, while ensuring a minimal overshoot (less than 1%). Simulate the original system for this gain and compare the results

Part A)

Part A)

Part B) An approximation of the overshoot and peak time for a selected value of gain K can be found from the location of the dominant poles of the closed- loop system. For poles at location -σd ± jωd, the overshoot is calculated as: %OS = exp(-σdπ/ωd) * 100% and peak time as: Tp = π/ωd. Tp = OS =

Time Response

For gain: K = 0.5 yields an estimated peak time of: Tp = settling time of: Ts = and percent overshoot of: OS =

Animation

Problem 3

PROBLEM DEFINITION

a)Find the transfer function G(s) of the system represented by the given differential equation. b) For the obtained transfer function G(s) from part a, find the system response C(t) for unit step input r(t)= u(t) assuming zero initial conditions. c) Find the value of gain K to yield a 2% error in the steady-state. d) For the obtained gain K in part c, find rise time Tr and settling time Ts. e) Using matlab plot closed-loop system step response for K = 1 and K obtained in part c. f) Give full comment on the simulated results obtained in part e for the required values of gain K

Transfer Function

System Response for Unit Step Input

The value of gain K to yield a 2% error in the steady-state

For K = 196

e) MATLAB produces closed loop system output step responses for K=1

e) MATLAB produces closed loop system output step responses for K=196

comment on the simulated results For K=1 simulated Ts, Tr and Tp are: Ts = 6.18 sec; Tp=8.92sec; and Tr = 3.53sec While for K=196 Ts=0.155sec; Tp=0.25sec; and Tr=0.0883sec steady-state error for K=1 and for K=196

Animation

Problem 4

PROBLEM DEFINITION Manufacturing Robotics Robotics has revolutionized the manufacturing industry, particularly in the manufacture of automobiles. The image below shows the GM Fanuc Robotics Corporation Model P-150, six-axis articulated arm, electric-servo-driven robot painting an automobile*. The six axes are simultaneously controlled, and driven by state-of-the-art compact ac servomotors. The result is a responsive system with fast acceleration and deceleration, precision painting, and requiring no brush maintenance

Block Diagram

Using MATLAB do the following 1. Find the closed-loop transfer function T(s) for the system described in the figure. 2. Display the step response for unity amplifier gain and step input. 3. Calculate the amplifier gain Ka which will result in a critically damped system

Part 1 & 2

The step response for system, showing transient response characteristics

Part 3

Step response of critically damped system

Animation