Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Mariana Petris, NIPNE - Bucharest C B M In-Beam Test Results of the Pestov Glass.

Slides:



Advertisements
Similar presentations
Development of high-rate timing RPCs L. Lopes 1,2, R. Ferreira Marques 1,2, P. Fonte 1,3, A. Pereira 1, V. Peskov 4, A. Policarpo 1,2 1 - Laboratório de.
Advertisements

KVI test experiment with existing RPC types for NeuLAND.
Wang Yi, Tsinghua University SoLID collaboration meeting, Status of MRPC-TOF 1 Wang Yi Department of Engineering Physics Tsinghua University,
Mariana Petris, CBM Collaboration Meeting, March 9 – 13, 2009, GSI Darmstadt Layout and first test results of new TRD prototypes Mariana Petris, NIPNE.
Development of high rate RPCs Lei Xia Argonne National Laboratory.
E/π identification and position resolution of high granularity single sided TRD prototype M. Târzilă, V. Aprodu, D. Bartoş, A. Bercuci, V. Cătănescu, F.
1 MRPC detector as polarimeter for dEDM Characteristic of detector Time Resolution Electronics Possible R&D Plans D. Babusci, A. Ferrari, P. Levi Sandri,
Development of timing RPCs Presented by P.Fonte for the TOF-RPC group.
Status of MRPC-TOF Wang Yi Department of Engineering Physics Tsinghua University, Beijing, China 1.
Progress report NeuLAND Outline Short reminder about NeuLAND Timing RPC concept Open questions - Impedance matching RPC prototype at GSI Next steps Collaboration.
ARNAB BANERJEE Variable Energy Cyclotron Centre, India.
1 Analysis of TOF data Yordan Karadzhov St.Kliment Ohridski University of Sofia.
New MRPC prototypes developed in Tsinghua Unversity Huangshan Chen (Tsinghua Unversity)
Mauro Raggi Status report on the new charged hodoscope for P326 Mauro Raggi for the HODO working group Perugia – Firenze 07/09/2005.
Institute for Safety Research Dávid Légrády IP-EUROTRANS ITC2 Development of a Neutron Time-of-Flight Source at the ELBE Accelerator ELBE Neutron source.
November 5, 2004V.Ammosov ITEP-Moscow, Russian CBM meeting 1 IHEP possible participation in CBM TOF system Vladimir Ammosov Institute for High Energy Physics.
24/03/2011P.-A. Loizeau – Univ. Heidelberg The CBM Time of Flight wall electronic readout chain Pierre-Alain Loizeau PI – Uni Heidelberg DPG 2011, Münster.
15 th CBM collaboration meeting, GSI, Darmstadt, Germany, April 12-16, 2010Wang Yi, Tsinghua University R&D status of low resistive glass and high rate.
CBM-Meeting, Darmstadt A.Schüttauf for the FOPI- collaboration FOPIs new MMRPC-barrel.
Fast TRD - R&D Status Mihai Petrovici, CBM-Meeting, Feb , 2008, GSI Introduction Short review - First HCRTRD prototypes: - MWPC – w & w/o drift zone.
V. Ammosov 13th CBM meeting,GSI,March 10 1 Beam test of pad tRPCs with ultra-thin glass Status of IHEP+INR activity for high rate RPCs.
RPC R&D status in Bucharest (JRA12-I3HP) Mihai Petrovici - CBM-Meeting, GSI, March 1,2006 Short history SMSMGRPC – Glaverbel Glass Prototype –Construction.
Third workshop on hadron physics in ChinaWang Yi, Tsinghua University A conceptional design of SOLID-TOF Outline: Development of low resistive glass and.
RPC detection rate capability ≈ 1/ρ Float-Glass ( Ω-cm) RPC rate capability < Bakelite( Ω-cm) one. New kind of doped glass was developed.
Prototypes of high rate MRPC for CBM TOF Jingbo Wang Department of Engineering Physics, Tsinghua University, Beijing, China RPC-2010-Darmstadt, Germany.
(Santiago de Compostela-Spain)
1 A.Andronic 1, H.Appelshäuser 1, V.Babkin 2, P.Braun-Munzinger 1, S.Chernenko 2, D.Emschernmann 3, C.Garabatos 1, V.Golovatyuk 2, J.Hehner 1, M.Hoppe.
F.Murtas1IMAGEM DDG GEM technology for X-ray and Gamma imaging IMAGEM l Detector setup l First results on X-ray imaging l First results on Gamma ray imaging.
Ingo DeppnerDPG-Frühjahrstagung, Mainz, A Multistrip-MRPC Prototype for the CBM Time-of-Flight Wall Outline: CBM-ToF requirements Conceptional.
Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.
July 8, 2003V.Ammosov GSI, CBM meeting1 RPC TOF system for HARP experiment (Applicability for CBM) Vladimir Ammosov Institute for High Energy Physics Protvino.
MRPC Beam GSI Yongjie Sun University of Science and Technology of China.
CBM Collaboration Meeting, GSI Experimental features of strip-RPCs Motivation FOPIs Multistrip-Multigap-RPCs Results Conclusions.
RPC Design Studies Gabriel Stoicea, NIPNE-HH, Bucharest CBM Software Week GSI-Darmstadt May 10, 2004.
Test of the GEM Front Tracker for the SBS Spectrometer at Jefferson Lab F. Mammoliti, V. Bellini, M. Capogni, E. Cisbani, E. Jensen, P. Musico, F. Noto,
Mariana Petris, The 11th Vienna Conference on Instrumentation, Feb. 19 – 24, 2007 High Counting Rate Transition Radiation Detector Mariana Petris, Mihai.
Ingo DeppnerRPC 2012 Workshop, INFN, Feb A Mutistrip MRPC prototype for the CBM Time-of Flight wall Outline: Motivation / CBM-ToF Requirements.
ITEP participation to the CBM TOF project ITEP ALICE - TOF group CBM – Russia meeting at ITEP, Nov 5 th, 2004.
Marcello Abbrescia Muon general meeting, Mon 29-Apr p. 1 R&D on improved RPCs for phase 2 upgrade M. Abbrescia on behalf of the RPC upgrade group.
Marcello Abbrescia RPCs for CMS during Phase II RPC rate capability M. Abbrescia, The dynamic behaviour of Resistive Plate Chambers, NIM A 533 (2004) 7–10.
Development of RPC based PET B. Pavlov University of Sofia.
XIII workshop on RPC and related detectors. GENT university, Belgium, Feb Wang Yi, Tsinghua University 1 Development and test of real-size.
Prof. Peter Mustermann | Institut xxxxx | Seite 1 Dr. Lothar Naumann | Institute of Radiation Physics | Investigation of ceramic.
Quality Assurance procedures for the construction of ALICE TOF detector VIIIth Workshop on Resistive Plate Chambers and Related Detectors October.
Ingo DeppnerDPG-Frühjahrstagung, Darmstadt, März Outline: CBM-ToF requirements What is an (M)RPC? Tof wall arrangements Ceramics RPC and.
Workshop on STAR upgrade. Sep th, 2015, USTC, Hefei Wang Yi, Tsinghua University 1 Status of high rate MRPC for CBM-TOF Outline: Introduction of.
Ingo DeppnerSTAR Regional Meeting at USTC Hefei Ingo Deppner Physikalisches Institut der Uni. Heidelberg CBM TOF prototypes STAR Regional.
TPC R3 B R3B – TPC Philippe Legou Krakow, February nd
XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, Aging test of high rate MRPC Wang Yi Department of Engineering.
eTOF - status and plan CBM-STAR joint Workshop Outline Introduction
High rate time of flight system
Performance studies of a single HV stack MRPC prototype for CBM
Department of Engineering Physics, Tsinghua University, Beijing, China
RPC with strip readout Last results from test of timing glass
Performance of timing-RPC prototypes with relativistic heavy ions
A proposal to equip the high eta muon stations with High Rate GRPC
Sensitivity of Hybrid Resistive Plate Chambers to Low-Energy Neutrons
Saikat Biswas, A. Abuhoza, U. Frankenfeld, C. Garabatos,
RPC working gas (C2H2F4/i-C4H10/SF6): Simulation and measurement
GRPC activity for EuDHCAL in IHEP-Protvino
Multigap Resistive Plate Chambers (MRPC)
Conceptual design of TOF and beam test results
Time-of-flight with LAPPD MCP-PMTs & MRPC
Performance of a Multigap RPC prototype for the LHCb Muon System
Update on SoLID-TOF Wang Yi Outline: Conceptual design of SoLID-TOF
Summer 09 Testbeams SDHCAL prototypes
AIMS 1- Build SDHCAL prototype of 1m3 as close as possible to the one
High time resolution TOF for SoLID
Aging test of glass and MRPC
Gain measurements of Chromium GEM foils
Presentation transcript:

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Mariana Petris, NIPNE - Bucharest C B M In-Beam Test Results of the Pestov Glass Resistive Plate Counter Prototypes

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Motivation Standard Read-out Pestov Glass RPC Prototype - Construction Details - 60 Co Source Test - In-Beam tests Differential Read-out Pestov Glass RPC Prototype - Construction Details - In-Beam tests Conclusions and Outlook Outline

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna RPC Counting Rate Performance MSMGRPC based on commercial float glass (  glass ~  cm) keeps the performances up to ~1 kHz/cm 2 ; this type of RPC could be a solution for a major part of the CBM - TOF subdetector. CBM - TOF subdetector at small polar angles – high counting rate environment (up to 20 kHz/cm 2 ). Solutions: –Electrodes with lower resistivity –Smaller and many gaps Our prototypes were built using Pestov glass with  ~10 10  cm.

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna glass sampl e Volume Resistivity Measurements of Pestov Glass Experimental Setup Measurement Setup: Device – Keithly Picoampermeter 487; Measurement Duration – 100 ps; Applied voltage – 100 V; Condition – 22 0 C, 42 % LF Power supply pA-Meter Measurement electrode Measurement electrode Guard-ring Conductive rubber sample Counter electrode Point 1Point 2Point 3Point 4

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Electrode sequence: - 2 mm aluminum – cathode mm nylon fishing line - 2 mm glass plate (supporting the spacers) mm nylon fishing line - 2 mm glass plate mm double faced strip readout plate symmetry plane Readout electrode: - support:0.5mm thick pcb plate - 14 copper coated strips on each side - pitch: 2.54 mm, 1.10 mm strip width, 1.44 mm gap width Sizes: glass electrodes: 40.6 x 300 mm 2 readout plate: 0.5 x 40.6 x 360 mm 3 housing: 40 x 80 x 330 mm 3 Al box Construction details of the standard – readout Pestov glass RPC prototype

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna 60 Co Source Test 85% C 2 F 4 H 2 +10% SF 6 + 5% izo-C 4 H 10  ≤ 60 ps

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna In-Beam ELBE (Electron Linac with high Brilliance and low Emittance) Forschungszentrum Dresden-Rossendorf Experimental setup: - electron beam, 30 MeV, 45 0 by a 18  m Al foil; - plastic scintillators S5(XP2972), S12(XP2020), S34(XP2020), (2 x 2 cm 2 ) used for active collimation; - signal amplification: FEE1 developed for FOPI at GSI. - digital converters: CAEN ADC V965, CAEN TDC V1290N - DAQ – MBS (Multi-Branch System – GSI – Darmstadt) - information recorded for 4 central strips V. Ammosov et al., Nucl. Instr. And Meth. A 576 (2007), 331

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Time resolution

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Time resolutions of the strips 6 and 7 Strip no. 6 Strip no. 7 Cond. Qmax

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Time resolution of the strips 8 and 9 Strip no. 8Strip no. 9 Cond. Qmax

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Position dependence Strip no. 8 No significant position dependence for strip # 6,7,9.

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Time resolutions of the 4 measured strips These results have been obtained No correction for the intrinsic electronic time resolution These results have been obtained with a uniform exposure of the counter active area at a particle flux density of ~1kHz/cm2.

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Rate dependence No saturation effect of the number of events recorded by the Pestov glass RPC as a function of counting rate

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Differential Strip – Readout Pestov Glass RPC Prototype

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna In-Beam ELBE (Electron Linac with high Brilliance and low Emittance) Forschungszentrum Dresden-Rossendorf Experimental set-up: - electron beam, 28 MeV, 45 0 by a 18 μm Al foil; - plastic scintillators S5(XP2972), S12(XP2020), S34(XP2020), (2 x 2 cm 2 ) used for active collimation; - signal amplification: differential readout based on NINO chip. - digital converters: CAEN TDC V1290N - DAQ – MBS (Multi-Branch System – GSI – Darmstadt) - information recorded for 2 central strips

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna 100 nA ≡ 975 Hz/cm nA ≡ 1872 Hz/cm 2 Time resolution as a function of counting rate

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna 500 nA ≡ 3100 Hz/cm 2 Time resolution as a function of counting rate 750 nA ≡ 4430 Hz/cm 2

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Time resolution as a function of counting rate 1500 nA ≡ 8440 Hz/cm nA ≈ Hz/cm 2

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Time resolution as a function of counting rate No deterioration of the time resolution as a function of counting rate up to ~ 16 kHz/cm 2

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Conclusions and Outlook Three RPC prototypes based on PESTOV glass with a resistivity of ~10 10 Ωcm were tested in-beam in the first part of this the ELBE facility at Forschungszentrum Dresden-Rossendorf. Standard readout Pestov glass RPC prototype. The 60 Co source tests show that the prototype has a good time resolution; Its performances in terms of time resolution -52 ps, were confirmed by the in- beam tests, fulfilling the requirement for the CBM-TOF subdetector. This time resolution was obtained in condition of a uniform exposure of the counter active area at a particle flux density of ~1kHz/cm 2. Differential strip readout RPC prototype was designed and built by us. The in-beam test showed the good performance of the counter with differential readout based on NINO chip in terms of time resolution – 69 ps. No significant deterioration of the time resolution as a function of counting rate was observed up to ~ 16 kHz/cm 2. Differential pad readout RPC prototype was also tested ELBE facility. The data are going to be analyzed.

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Participants NIPNE – Bucharest D. Bartos G. Caragheorgheopol M. Petris M. Petrovici V. Simion FZD – Dresden Rossendorf D. Stach F. Dohrmann R. Kotte L. Naumann J. Wüstenfeld GSI – Darmstadt K. Hildenbrand CERN - Geneva C. J. Williams

Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Diferential pad readout RPC prototype Better granularity: Cell size: 0.5 x 2 cm 2