EuP4Light, good or bad for reducing light pollution in Europe Friedel Pas European Liaison Officer International Dark-Sky Association 7th European Symposium for protection of the Night Sky Bled, Slovenia 5-6 October 2007
Agenda What is EuP IDA and EuP-project The report Recommendations Scenario’s EU plans with EuP What next?
EuP4Light
Directive 2005/32/EC Part of the European Climate Change Programme (ECCP) EuP = Energy using Products What: Increasing Ecological Performance of the complete life cycle. Purpose: Reduce greenhouse gasses, beter use of the resources
What is EuP Impact analysis for Water / Energy / Garbage Product related. Must result in eco-desing requirements Best sollutions selected in co-operation with stakeholders. Energy Labels for refrigerators,…
EuP4Light Street lighthing (final text march 2007) Office Lighting (final text may 2007) Domestic Lighting (ongoing) http://www.eup4light.net Research team: Paul Vantichelen, B.Jansen, T.Geerken, M.Vanden Bosch(Laborelec), V.Van Hoof, L.Vanhooydonk(Kreios),A.Vercalsteren. IDA Europe Stakeholders: Friedel Pas, Andreas Haenel (Germany), Dr. Jan Hollan (Czech Republica), Dr. Fabio Falchi (Italy)
Wath is EuP Product related No items on installations No existing legislation that is not product related
The report
The report Handles about eco-design of: Lamps Ballasts Luminaires Combination of all Market analyse Expected growth of lighting in Europe. BAT & BNAT “fixed lighting installation intended to provide good visibility to users of outdoor public traffic areas during the hours of darkness to support traffic safety, traffic flow and public security” (EN13201)
Performance requirements Must be comform with EN13201-2 Simplified road categories of EN13201-1: Category F “fast traffic”: fast motorized traffic use only. Category M “mixed traffic”: motorized traffic, slow moving vehicles, and possibly cyclists and pedestrians. Category S “slow traffic”: for mainly urban and pedestrian aimes.
Existing leglislation Light pollution/nuisance related: Most existing legislation not adapted because not product related. Lombardy law 0 cd/klm over 90°. Minimum luminance/illuminance = maximum Dimmable after midnight Need to be certified.
Data Data is underestimated. Data for 2005 in EU-25: Only several countries give real data Other data incomplete, not available or no response. Most data estimations on road data. Data for 2005 in EU-25: Road length: 5318766 km Number of luminaires: 58,904 mlj Nbr luminaires/capita: 0,12 Nbr luminaires/km road: 11,075 -> 1 lum./90m when 1lum./30m->1767120km lit roads => 33,2% illuminated.
Crime and lighting The absolute reduction of crime by public lighting is not proven and controversial: Exist no good studies until now. Light alone is no cure => need social control. Lighting CAN improve social control. Lighting increase safety feeling.
Treaths to energy savings on public places Lack of interest by authorities: Financial aspects Trend of city beautification: aesthetic more important then eco-desing aspects. Lack of interest by architects. Lack of skilled work force: Advanced lighting saving techniques requires aditional skills: Telemanagement Correct installation skills Fine tuning optic systems Urban architects need street light design skills.
Light Pollution in the report Split in: Astronomical light pollution. Ecological light pollution. Sky glow most caused by light going into the sky between horizontal and 10° No scientific proof of ecological consequences of light pollution. >Not to deal with it until the consequences are proven.
Use Phase Most efficient luminary bad used can result in very bad energy waste.
BAT and BNAT IP66 Self Cleaning Glasses Improve of Utilisation Factor Limiting ULOR Maximizing DLOR
Space Height Ratio (SHR) Higher SHR have less lighting poles, less installation cost and less energy. Curved glass have avarage SHR: 5. FCO with flat glass have avarage SHR: 4 -> not energy efficient solution. Brewster angle effect More internal reflection. More light reflected to the sky because more light on the road -> more sky glow.
Space Height Ratio (SHR) Where the Lombardy law is active: Flat glass FCO luminaires with SHR 5 to 5,7 By the use of anti-reflection coating. Study not recommend it because it is not common available Light manufactures said they not offer it everywhere because of a pattent Pattent is from 1978 Is expired at the moment.
FCO reflect more light Because more light on target area. So dim the light for have the same lumminance. Light going into sky between horizontal and 10° cause most sky glow.
Recommendations
Recomendations Products need an information sheet (label) Information about eco-desing parameters Luminaires: Street light indication + road category Photometric data LMF for first 4 years Maintenance instructions. UF for standard road conditions. Installation instructions for optimize UF Installation instructions to minimize light pollution.
Recomendations Generic eco-design requirements on reducing light pollution: Require manufactures during design reducing light pollution. When no negative effect on energy efficiency. When more evidence on environmental significance standardization commissions have to develop harmonized standards.
Recommendations Luminary efficiency requirements: ULOR max DLOR min UFF Cat. F+M All lamp wattages 5% 75% 6,25% Cat. S 150W<=lamp Cat. S 100W<=lamp<150W 10% 11,76% Cat. S 50W<=lamp<100W 15% 70% 17,65% Cat. S lamp<50W 20% 65% 23,53%
Recommendations Optional use of dimmable ballasts Cat.F +M: implementing before 2010, >=70W before 2015 Good for avoiding over lighting (reflection) Good for controlling light depending on traffic numbers trough the night.
Additional recommendations Maximum light levels. Peformance requirements for traffic density on hourly base. Member states need to invest in inventory of their infrastructure.
EU plans with EuP
EU plans with EuP Questions in EP: We are busy with light pollution by EuP4Light Brussels European Council on 9/3 on CO2 reduction: “invites the Commission to rapidly submit proposals to enable increased energy efficiency requirements on office and street lighting to be adopted by 2008 and on incandescent lamps and other forms of lighting in private households by 2009;”
What is next
What is next… Evaluation commission of energy Can accept of not accept the contence of the study. Translate the recommendations in directive proposals.
What next Proposals go to the commissioners Commissioners send it to EP When Commission and EP not agree, also opinion of the European Council => MEP’s need to awake in time
More information EuP4Light document is online: http://www.eup4light.net IDA Europe comments and actions Friedel Pas European Liaison Officer Aarschotsebaan 29 3191 Hever Belgium Tel.: +32-474-501795 e-mail: europe@darksky.org