CIMON PLC KDT Systems Co., Ltd.. KDT SYSTEMS Why CIMON PLCs ? All CPU share the same programming environment (CICON) All CPU share the same programming.

Slides:



Advertisements
Similar presentations
Supervisory Control & Data Acquisition DAQ Networking.
Advertisements

Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Efficient Management for Building Automation. Market Trend.
IDEC AUSTRALIA PTY LTD, UNIT 17, 104 FERNTREE GULLY RD, OAKLEIGH, VIC 3166 High Performance, Compact and Economical.
Modular PLC systems A, AnS and Q Series PLCs. System concept Wide range of solutions Added functions for Q series A, AnS and Q Series PLCs Questions.
Turbo PMAC Clipper One Board Control Solution Low Cost, 4 Axis controller with I/O and Ethernet A Turbo PC/104 with Acc-2P combined for a 30% cost reduction.
EUT 1040 Lecture 10: Programmable Logic Controllers.
OVERVIEW TBOX The best of 3 worlds.... TBOX The best of 3 worlds...  best of Automation  best of Internet  best of Telemetry.
File/ 1 Primary colours Secondary colours Remember to change file name 28pt Ariel bold 18pt Ariel bold l Distributed PID Control and I/O What is.
Microprogrammes control the KOMBIS TMM8003. For the reliable operation of its systems and devices there are several programs located in two controllers.
ADAM-4572 Ethernet To Modbus Solution Ethernet to Modbus Data Gateway
PROGRAMMABLE LOGIC CONTROLLERS PLC’S
 A system consisting of a number of remote terminal units (or RTUs) collecting field data connected back to a master station via a communications system.
Chapter 8 Output Modules.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
8/8/2015 Page 1 Νίκος Λεοντάρης Μηχανικός Τηλεπικοινωνιών Ιούνιος 26/ ADAM-4000 Remote DA&C Modules Product Overview.
LabView Users Group Meeting June 20 th, 2006 Process Control Using Compact Field Point/Labview Real-time Michael Tockstein Microelectronics Technology.
ADAM-5000/TCP- Distributed Ethernet I/O
Alternative Energy Class Room Automation Control System Lighting and Temperature Control By: Al Woodward EET-2011.
2500 Series ® Compact I/O System. Where does Compact I/O fit? – When 2500 Series ® “Classic” system is too large to fit the application – When fewer I/O.
Hall C’s HMS PLC Controls by Steven Lassiter. What Constituents a PLC System PLC (processors) Programming. I/O modules. Field Device Signals (sometimes.
SCADA and Telemetry Presented By:.
Partnership for Growth January 19, Machine PLCs Temp Controllers Servos & AC Drives Power Supplies HMIs Sensors “We Automate Machines”
Signal Conditioning & I/O By: YH Goh Technical Evangelist RLC AP.
1 © Red Lion Controls Inc. Introducing the RAM 9000.
K200S Introduction.
7526A Precision Temperature/Pressure Process Calibrator
IRRInet & ICC System Concept
Looking for a more powerful circuit monitor?
Total Solution For Industrial Automation. Power Plant Cogeneration Power Plant –Generate Electricity –Provides Steam & Warm Water DCS : Westinghouse Electric.
A BRIEF INTRODUCTION TO FIELDBUS 4 hf NETLOGIC PLC TRADITIONAL CABLING SYSTEM TERMINAL BOARD.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
Identifying SLC 500™ System Components. SLC 500 System Options  The SLC 500 line of processors comprises both fixed and modular processor styles.:
AKR Sales Training For KOMAF Exhibition Kunyu Lee Product Manager
Final Project Review – 4/10/2008 Al Mukmin Judson Ryckman Miguel Roncal Paul Otto Walter Thorn.
Unitronics 2009.
Schutzvermerk nach DIN 34 beachten XC200 Hardware Overview.
PWC Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview.
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
TYPICAL SCADA SYSTEM FIELD UNIT SCADA H/W & S/W C TX O RX M E M Q N P
SoftPLC In TealwareTM SoftPLC ProcessorsTM Hardbook SoftPLC’s
CIMON TOUCH KDT SYSTEMS Introduction  Excellent Durability  The mobile CPU of the TOUCH gives excellent durability under industrial environment.
Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between.
New product introduction:
Series LECSC (CC-Link direct input type) ●Can set position and speed data, and start and stop operation. ●Positioning at a maximum of 255 points by using.
BASIC STRUCTURE OF PLC.
FC6A MicroSmart IDEC Next Generation Micro PLC
PROGRAMMABLE LOGIC CONTROLLER. Control Systems Types  Programmable Logic Controllers  Distributed Control System  PC- Based Controls.
Programmable Logic Controller & Distributed Control System Yoon-Je Choi 17 th June 2006.
AC890PX High Power Inverter. The history of SSD LINK LINK 1 was the first fiber optic peer-to-peer network of its kind. Its sole purpose was.
An Overview When Connecting to Yaskawa Drives Date: 8/14/06, Rev: PP.AFD.26.
1 Data Acquisition, Monitoring & Management Solutions Supplied by DCM Transcal Phone or
Directlogic Automation PLC Product Overview. We supply and support the well known & respected Directlogic range of PLC’s from Koyo Electric Japan.
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. PUBLIC PUBLIC CO900H L06 - Developing Safety Applications Using the Guardmaster®
Identifying SLC 500™ System Components. SLC 500 System Options  The SLC 500 line of processors comprises both fixed and modular processor styles.:
October 2010 SmartAXIS Controller. High Performance, Compact and Economical.
Modular C ontroller S eries Product Introduction.
2500 Series® Compact System Components
UNICOS: UNified Industrial COntrol System CPC (Continuous Process Control) Basic course SESSION 3: PLC basics UCPC 6 UNICOS-Continuous Process Control.
Programmable Logic Controllers: I/O
SCADA for Remote Industrial Plant
FEEDER PROTECTION UNIT
2500 Series® Compact System Components
Computer Communication
Identifying SLC 500™ System Components
HMI CP Range General Presentation.
2500 Series® Compact System Components
PLC’s Are ... Similar to a Microcontroller: Microprocessor Based
GasGard 100 Control System
Presentation transcript:

CIMON PLC KDT Systems Co., Ltd.

KDT SYSTEMS

Why CIMON PLCs ? All CPU share the same programming environment (CICON) All CPU share the same programming environment (CICON) No additional training needed for up/down sizing of control systemNo additional training needed for up/down sizing of control system Though BP series are small sized PLC, they inherit powerful functionalities from higher series of CIMON PLCs (CP/XP)Though BP series are small sized PLC, they inherit powerful functionalities from higher series of CIMON PLCs (CP/XP)

KDT SYSTEMS Why CIMON PLCs ? CP and XP CPU share the same modules CP and XP CPU share the same modules I/O modules, special function modules, power, base....I/O modules, special function modules, power, base.... Provides big merit on maintenance as well as cost.Provides big merit on maintenance as well as cost.

KDT SYSTEMS Why CIMON PLCs ? Fully verified network compatibility Fully verified network compatibility not only between PLCsnot only between PLCs but also SCADA and Panels (TOUCH, XPanel)but also SCADA and Panels (TOUCH, XPanel)

KDT SYSTEMS What is different ? : Technologies How many PLC manufacturers support redundant system in all around the world ? How many PLC manufacturers support redundant system in all around the world ? CIMON supports redundant PLC CPU system.CIMON supports redundant PLC CPU system. and we have some good references as power plant.and we have some good references as power plant.

KDT SYSTEMS Redundant CPU Details

KDT SYSTEMS What is different ? : Expansion Innovative base expansion system Innovative base expansion system Provides easy engineering with simple cableProvides easy engineering with simple cable Removes the distance limit between basesRemoves the distance limit between bases Plays the same role of remote I/O, but faster.Plays the same role of remote I/O, but faster. Expansible up to 16 basesExpansible up to 16 bases Category 5, 10Base-T, Max 100m

KDT SYSTEMS CPU EP02A EP02A  2 Port  10Mbps Ethernet Expansion numner setup by rotary switch Expansion numner setup by rotary switch EP01A EP01A  1 Port  10Mbps Ethernet LOCAL EXPANSION #1 EXPANSION #2 EXPANSION #14 EXPANSION #15 EXPANSION #16

KDT SYSTEMS What is different ? : Ethernet Take the internet on your fields Take the internet on your fields Even BP supports the ethernet. (option)Even BP supports the ethernet. (option) Remote maintenance by internet : The CICON can connect with a PLC though internet.Remote maintenance by internet : The CICON can connect with a PLC though internet.

KDT SYSTEMS What is different ? : CICON Dialog based configuration Dialog based configuration Removes DIP switches from special function modulesRemoves DIP switches from special function modules Dialog based programming Dialog based programming Generates sequence program automaticallyGenerates sequence program automatically PID, Protocol, Network configurationsPID, Protocol, Network configurations Special function card configurationsSpecial function card configurations Thermistor, Loadcell, position (pulse output) Thermistor, Loadcell, position (pulse output) Continued ....Continued ....

KDT SYSTEMS Dialog based programming

CPU Specifications

KDT SYSTEMS CPU Specification : XP XP1RXP1AXP2AXP3A Program Memory 128 Kstep64 Kstep I/O Point USB / RTC USB / RTCYes MemoryD: Words / M,L,K: Points / T,C: 4096 RedundancyYesNo

KDT SYSTEMS CPU Specification : CP CP3P : Removable flash memory CP3P : Removable flash memory CP3ACP3BCP3PCP3UCP4ACP4BCP4CCP4DCP4U PgmMem 32 KStep16 KStep I/O DataMem RTCNoYesNo Yes USBNoYesNoYes Comm.No RS232CRS422/485

KDT SYSTEMS CPU Specification : BP InputOutput BP32MDT 16 DC24V 16 Tr. Sink BP32MDCTr. Source BP32MDRRelay BP16MDT 87 Tr. Sink BP16MDC Tr. Source BP16MDR Relay

KDT SYSTEMS CPU Specification : BP BP32M  Abundant program capacity:  8,000 Step  Device Range:  Internal Relay: 4,096 Points  Data Memory: 5,000 Words  Max. 3 block expansion BP16M  Abundant program capacity:  4,000 Step  Device Range:  Internal Relay: 4,000 Points  Data Memory: 1,000 Words  Not expansible

Basic Modules

KDT SYSTEMS PowerSPASPC/SPRSP2B Input Voltage AC 90~240V, 50/60Hz DC 24V Input Current 0.25A Max for 220VAC 1.8A Max Inrush Current Less than 30A Output Voltage/Current +5V / 3.5A +24V / 0.5A +5V / 3.5A +24V / 0.5A +15V / 0.5A -15V / 0.3A +5V / 3.5A +15V / 0.5A -15V / 0.3A SPA cannot be used with analog/temperature modules

KDT SYSTEMS Base Model I/O Slots CM1-BS03A3 CM1-BS04A4 CM1-BS05A/R5 CM1-BS08A/R8 CM1-BS10A/R10 CM1-BS12A12

KDT SYSTEMS Digital Input XD16AXD16B  16 DC 24V Input  Photo coupler isol ation XD32CXD32B  32 DC 24V Input  Photo coupler isolati on XA08A XA08B  8 AC Input XY16DR  8 24Vdc Input  8 Relay Output

KDT SYSTEMS Digital Output YR16A  16 Relay  2 Amp / 240VAC YS08A  8 SSR  100~240Vac YT16AYT16B  16 Tr. Output  0.5A / 24V  Sink /Source YT32AYT32B  32 Tr. Output  0.2A / 24V  Sink /Source

KDT SYSTEMS Analog Input  All settings are configured by CICON  Input Voltage : 0 ~ 5V, 1 ~ 5V, 0 ~ 10V, -10 ~10V  Input Current : 0 ~ 20mA, 4 ~20mA  Resolution : 14 bit  Photocoupler isolated AD08V Voltage Input 8 Ch. AD08I Current Input 8Ch. AD04VI Voltage/Current Input 4 Ch. (configurable)

KDT SYSTEMS Analog Output  All settings are configured by CICON  Output Voltage : -10 ~10V  Output Current : 4 ~20mA  Resolution : 14 bit  Photocoupler isolated. DA04V Voltage output 4 Ch. DA08V Voltage output 8 Ch. DA04I Current output 4 Ch. DA08I Current output 8 Ch.

Special Function Modules

KDT SYSTEMS RTD  4 Channels  All settings are configured by CICON  Resolution : 14 bit  Real temp. value provided (in C, F)  Resolution in Temp. : 0.1 C  Photo coupler isolated RD04A for Pt.100, JPt.100 RD04B for Pt.1000, JPt.1000

KDT SYSTEMS Thermocoupler TC04A  4 Channels  All settings are configured by CICON  Resolution : 14 bit  Real temp. value provided (in C, F)  Resolution in Temp. : 0.1 C  Photo coupler isolated

KDT SYSTEMS Thermistor TH08A  8 Channels  All settings are configured by CICON  includes resistance table input  Type : NTC thermistor  Resolution : 14 bit  Real temp. value provided (in C, F)  Resolution in resistance :  100Ω ~ 40kΩ : 1Ω  40kΩ ~ 400kΩ: 10Ω  400kΩ ~ 1MΩ : 30Ω

KDT SYSTEMS Loadcell WG02A / WG04A  2 or 4 channels loadcell input ( ~ 3mV/V)  1/200,000 resolution  Embedded batch process control (unloading/mixing/filling/bin)

KDT SYSTEMS High Speed Counter  2 Channels  All settings are configured by CICON  1-Phase input or 2-Phase input  32 bit counter  Speed : Max. 200 kPPS  Provides comparator output ( ) HS02B Voltage input signal (5, 12, 24 Vdc) HS02D RS422A input signal level (Line driver)

KDT SYSTEMS Pulse Output / Positioning PS02A  2 axis  Line driver pulse output (RS422A)  All settings are configured by CICON  Position parameter / tables  Supports 2 axis linear/arc interpolation  Speed : Max. 1 MPPS

Communication & Network

KDT SYSTEMS Serial Communication Application Protocol Application Protocol HMI-ProtocolHMI-Protocol MODBUS/RTU Slave & MasterMODBUS/RTU Slave & Master DNP3.0DNP3.0 PLC Link : Max. 32 stationsPLC Link : Max. 32 stations Loader (CICON) communicationLoader (CICON) communication Supports modem connection Supports modem connection Embedded RS232C-RS422/485 converter Embedded RS232C-RS422/485 converterSC01A RS232C 1 Ch. SC01B RS422/485 1 Ch. SC02A RS232C 1Ch. + RS422/485 1 Ch. SC01DNP RS232C 1 Ch. (DNP 3.0 protocol)

KDT SYSTEMS Typical Serial Application Plays a role of RS232C- RS485 Converter

KDT SYSTEMS Remote Network by Modem Leased Line Modem (DSU) or Dial-Up Modem

KDT SYSTEMS Ethernet No limit on number of EC01A with a CPU No limit on number of EC01A with a CPU Application Protocol Application Protocol HMI-Protocol, MODBUS/TCP, DNP3.0HMI-Protocol, MODBUS/TCP, DNP3.0 PLC Link : Max. 64 stationsPLC Link : Max. 64 stations Loader (CICON) communicationLoader (CICON) communication Protocol Stack Protocol Stack ARP, ICMP, IP, UDP, TCPARP, ICMP, IP, UDP, TCP 10BaseT, 10 Mbps 10BaseT, 10 Mbps

KDT SYSTEMS HMI Link by Ethernet

KDT SYSTEMS PLC Link by Ethernet

KDT SYSTEMS Data Logger LG32A / LG64A  Data log buffer for PLC  Logged data are retained in PLC while communication fail.  All logged data are transmitted to SCADA after communication recover.  Embedded communication  Protocol : HMI Protocol  Port : RS232C (supports cable / dial-up modem)  Internal non-volatile log memory : 32 MB / 64MB

BP Series Expansion Blocks

KDT SYSTEMS Expansion block naming : BP CM2 – BP (1) E (2) (3) Series Name Number of Points 04, 16, 32 Module Type E : Expansion Output Type T: Digital TR Output(Sink) C: Digital TR Output(Src) R: Digital Relay Output A: Analog Output O: No Output Input Type D: Digital DC 24V Input A: Analog Input R: RTD Input T: TC Input O: No Input

KDT SYSTEMS Digital I/O Expansion ModuleInputOutput BP16EDTBP16EDCBP16EDR8 DC 24V 8 TR Sink TR Source Relay BP32EDTBP32EDCBP32EDR1616 TR Sink TR Source Relay BP16EDO160- BP16EOTBP16EOCBP16EOR0-16 TR Sink TR Source Relay

KDT SYSTEMS Analog Expansion ModuleInputOutput BP04EAO4 Voltage/Current 0- BP04EAA22 Voltage/Current BP04E0A0-4 BP04ERO4 RTD (Pt.100/JPt.100) 0- BP04ETO4Thermocoupler0- Analog module can be expanded up to 2 modules.