Interior Of DMRC Rolling Stock by S.S.Joshi ED/Rolling Stock

Slides:



Advertisements
Similar presentations
Hoshizaki America has built a legacy of quality design, reliability and customer commitment. In our Commercial Series refrigeration line, youll see solutions.
Advertisements

Truck-Trailer Refrigeration Equipment
Presents 2012 Revisions to the NC Energy Code For Residential Building started after March 1, 2012.
BEVERAGE COOLERS HBC-95HBC-65 Stainless steel lids, countertop and glass stop. HBC-50 Full Safety and Sanitary Certifications. Heavy duty foamed in place.
Exploring Energy Management
Health Care Building Available for Sale! Immediate Delivery from our Bristol, IN plant. Call Don See Floor Plan and Specifications.
YUSUF OZ FATIH BOLUKBAS HUSEYIN ANIL KARABULUT. INTRODUCTION HOW DOES A CONTAINER BECOME HOUSE? DESIGN EXAMPLES A NEW HOME IN 12 STEPS TECHNICAL SPECIFICATIONS.
Energy Savings Impacts of the Advanced Energy Design Guide: Small Office Buildings Bing Liu, P.E. Research Engineer Pacific Northwest National Laboratory.
eQuest Quick Energy Simulation Tool
Building Envelope. Energy Conservation House design and orientation Lifestyle changes Energy efficiency.
Environmental Controls I/IG Lecture 14 Mechanical System Space Requirements Mechanical System Exchange Loops HVAC Systems Lecture 14 Mechanical System.
Mesut Altuntaş Furkan Turan
Engineering Sound CSUF - Meng Concert Hall Mark E. Rothermel Principal Rothermel & Associates, LLC Architectural Acoustics Collaborative.
The Three Tiered Philosophy
DATA ONE, EUROPEAN OPERATIONS CENTRE, ST. PETERSBURG, RUSSIA Presentation of Design Proposal.
CERT MEOC Mobile Emergency Operations Center Concept designed by Keith Morin & Associates - Tucson, AZ.
Summary of Heat Loss Calculations Assessing overall heating requirements for building (E) Component U-ValueAreaHeat Loss Rate (W o C -1 ) Walls U walls.
Johanna Mikitka AE-390 October 13, 2004
Chapter 5: Designing for Heating and Cooling 5.1 Organizing the problem a) Fenestration How much is optimum for the building? What should the form of the.
Heat Loss & Gain Calculations 1. How Heat Moves in Homes Conduction is the transfer of heat through solid objects, such as the ceilings, walls, and floors.
This 12 part PowerPoint series is taken directly from Energy Savers Booklet, Tips on Saving Energy & Money at Home, U.S. Department of Energy.
With over 60 years experience Mondial Forni ensures the highest baking quality and maximum reliability in their ovens. The Ciclomondial combustion gas.
Thermal Management Solutions from APW President Systems
 Site  Requirements  Local Resources  Initial layout ideas  Brief material selection  Supply options.
1 John Curley. 2 The opportunity 1) Cost Shift to lightweight architecture Increased heat loading within buildings Planning issues and outside space Energy.
© 2011 Pearson Education, Inc. All Rights Reserved Automotive Technology, Fifth Edition James Halderman AUTOMATIC AIR- CONDITIONING SYSTEM OPERATION 63.
1 SD Recorder OS-TM-V701A for Driving Security Surveillance.
Air Side System Evaluation
High Density Cooling Air conditioning for high density applications
Precedent Analysis arc 572 UT Solar Decathlon 2009 BLOOMhouse University of Texas at Austin I 2007 ARCHITECTURE I INTERIOR I TECHNOLOGY I SOCIETY architecture.
Energy Performance and Moisture Control of Ceilings and Roofs 1.
With over 60 years experience Mondial Forni ensures the highest baking quality and maximum reliability in their ovens. The NEW Dekomondial electric deck.
Building Simulation. BMEABMEA uilding odeling nergy nalysis.
Duralife By. Adding value to homes and lifestyles since 1962.
Phoenix Convention Center Phoenix, Arizona Integrative Design: Deep Energy Approach Track 6: Integrated Energy Session 5: Integration of the Energy Industry.
Zero Energy Home’s Features and Appliances Interior and Exterior Features: Roofing Insulation Windows Energy Saving Appliances.
PowerPoint ® Presentation Unit 52 Thermal Insulation and Other Insulating Methods Thermal Insulation Exterior Insulation and Finish Systems (EIFS) Roof.
-Too little or too much ventilation -Insufficient ventilation results in excessive indoor humidity -Uncontrolled ventilation can cause exhaust leaks within.
Science Project Advice on how to reduce energy losses.
Energy conservation strategies Buildings energy consumption depends on building envelop, efficiency of HVAC and lighting systems, amount of required fresh.
A R C H I T E C T S E M I N A R WEBER+THOMPSON Founded-1987 B.Arch: University of Hawaii Studied under Jorn Utzon and Arata Isozaki Chairman of Washington.
Recent Experience on Coach Interiors And Future Opportunities Integral Coach Factory, Chennai, India
A New Language Shining the Light on Passive Solar Features and Retrofit Possibilities.
Fire-Resistant Materials & Assemblies Part 2 Chapter 5.
METRO ROLLING STOCK INTERIOR DESIGN & DEVELOPMENT
EXPLORING ENERGY MANAGEMENT. PROJECT TITLE What is Energy Management? Energy management is doing more with the same amount of energy or less energy. Energy.
SMART PCA.
1200 South Dixie Hwy West * Pompano Bch, FL Phone: (954) * Toll Free: (800) * Fax: (954) ELDORADO AEROELITE Ford.
Central AC system for Auditorium
Natural Ventilation. Natural Ventilation can found in any old building that doesn’t have any HVAC systems. Natural ventilation is able to provide a space.
Call us : / AMAATRA HOMES NOIDA EXTENSION.
Shree Chand Homes Presents GOLF VIEW HOMES Situated at Greater Noida, Dadri Road next to Ansal’s Golf Link II a very close location From proposed Metro.
Easy FlowTM and Smart FlowTM
The New Switch can replace all the Old Room Needed Controllers 1– Light Switches and Wall Dimmers 2– Air-conditioning Thermostat 3– Volume Control 4–
We are one of the accredited manufacturers and suppliers of Accoustic Enclosure and Sound Proofing in northern part of India under brand Name of "DDSTHA".
Technical Seminar on Application and Technical Specification June 2016
COMPOSITES MASS TRANSPORTATION RAGHURAJ ANANTHOJ
26’ Mobile Kitchen. 26’ Catering Kitchen Trailer In stock and ready for delivery. Trailer details/features General Features: Aluminum diamond plate.
Energy loss in the home Insulation method including cost and saving
CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS
Energy loss in the home Insulation method including cost and saving
Air Distribution Control
Technology in Architecture
Ariana Kevelier Paul King Building Technology III
Facade Panes Dealers in UAE
Arch205 building construction Windows- glazed curtain wall, skylights
Exploring Greenhouse Structures
FBE03: Building Construction & Science
Exploring Energy Management
AUTOMATIC AIR-CONDITIONING SYSTEM OPERATION
Presentation transcript:

Interior Of DMRC Rolling Stock by S.S.Joshi ED/Rolling Stock DELHI METRO RAIL CORPORATION LIMITED

Interiors: Basic Design Philosophy Maximization of Passenger carrying space High passenger comfort including low noise level Passenger Information System Passenger Surveillance System Design life 30 years & Low life cycle cost DELHI METRO RAIL CORPORATION LIMITED

Maximization of Passenger carrying space Equipments placed in Under Frame/ Roof/underneath Seats Wide gangway between coaches Ergonomic Grab rail/ pole layout for adequate moving space as well as support to standees Further increase in standing space in UTO mode. DELHI METRO RAIL CORPORATION LIMITED

Interior Panel Design Improvements FRP Interior Panel Prepeg : Superior,No localization Hand Lay up: Pitting, Chipping, Cracks problems. RTM : yet to go in service Ceramic Coated Aluminum Interior Panel Less Prone to Vandalism Improved Aesthetics Less Thickness DELHI METRO RAIL CORPORATION LIMITED

Passenger Information System Bilingual announcement with auto adjustable volume Passenger Information Boards LED based, limitation for graphic display LCD based Internal side display Route maps Dynamic Communication b/w Passenger & Driver/OCC Provision for live video streaming. DELHI METRO RAIL CORPORATION LIMITED

Improved Passenger Surveillance System Four cameras in each saloon. PEA misuse arrested. Rear view camera Catenary camera and Track camera are provided for surveillance of OHE and Front track. Catenary camera Track camera Real time CCTV images on driver console; can be viewed also at OCC in UTO mode. DELHI METRO RAIL CORPORATION LIMITED

Camera Coverage Inside the car Saloon camera on T & M car ( 4 cameras per car) Camera has a local storage media, 16GB SD memory card and in-built digital zoom functions.

Air Conditioning & Ventilation Energy Guzzler: About 28% of total consumption. The air-conditioning load need to be controlled Conservative Interior temperature and humidity parameter settings Optimization of fresh air intake based on occupancy Use of Load signal to optimize the air-conditioning load. Thermal insulation on Carbody sidewall, roof & floor Double glass window, doors with thermal insulation . Energy Efficiency criteria: COP> 2.5 Emergency ventilation arrangement DELHI METRO RAIL CORPORATION LIMITED

Improved Exhaust arrangement in Saloon compared to previous stocks. Improvements in HVAC Design Improved Exhaust arrangement in Saloon compared to previous stocks. Return air Supply air diffuser Return air Split diagonal type Air duct design for uniform distribution of airflow and temperature gradient throughout the saloon compliant with EN14750 DELHI METRO RAIL CORPORATION LIMITED

Improvements in Noise reduction Features Floor Floating floor design Ceramic & Silicone foam insulation with PVC floor covering Doors & windows Aluminium honeycomb/PU Foam Acoustic sealing around the perimeter Double glazed Window with laminated glass pane Side Wall & Roof Glass Wool / Ceramic Wool Insulation Roof stainless steel ceilings with Al honey comb Gangway Double Skinned Gangway Floor design changed from UNITEX Floor to floating floor DELHI METRO RAIL CORPORATION LIMITED

LIGHTING CFL Lights in 2 circuits ( 50% on battery circuit) Operation in two modes (50%, 100%) LED Lights Energy efficient Longer Life (50,000 hrs) Automatic dimming using light sensors based on ambient light Improved Aesthetics DELHI METRO RAIL CORPORATION LIMITED

Modern Mobility for Modern Society THANK YOU DELHI METRO RAIL CORPORATION LIMITED