Xplorer 1-2 Loop Analogue Addressable Control Panels From 1-2 loops EN54 2 & 4 Compliance Fully compatible with all Apollo XP95 and Xplorer devices Extensive.

Slides:



Advertisements
Similar presentations
Prescient II Extinguishing Control Panels
Advertisements

Nexus 1-8 Loop (XP95) Analogue Addressable Control Panels
ID to 8 Loop Intelligent Fire Alarm Panel
Eagle Trading & Agencies has been established from the ground up for selling, managing and implementing mid to large size projects in the field of fire.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
Total HVAC Control from anywhere Easy control that can save a fortune
Discovery 1-4 Loop Analogue Addressable Control Panels
TG-EL-D5 Preferred Instruments Multi-Tank Gauge D5 Overview.
Reliability Different worlds – same problem …one solution: Redundancy
In this presentation you will:
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
KX-NS1000 PBX to PBX Networking For step by step : 16 May, 2012.
Crown DSi Series Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display.
Introduction System Schematic ~ LON-FO NC EC200 LOOPS 2-4 FIBRE OPTIC
PYRO-X De-Ice control devices Technical presentation 2013.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
VEGA CONTROL PANEL Technical
Training.
PYROCON12 De-Ice controller User Operation Presentation 2013.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
Precept Conventional Control Panels
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Graphical Alarm Management System
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
Networking All talk - Selective listen Network up to 15 active nodes + 17 passive nodes Nexus/Discovery panels, network repeaters, R3 19” racks, Alarm.
RP-2000 Series Deluge & Agent Releasing Panels
Guide to MCSE , Second Edition, Enhanced 1 Objectives Understand and use the Control Panel applets Describe the versatility of the Microsoft Management.
Fire Detection Presentation
An Introduction to the Windows-based PC Programming Tool Version 0.91
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
System Features Interactive Digital Addressable Fire Detection and Alarm System. Designed for Small and Medium Sized Installations.
FG Wilson Access 4000 Control Panel
GasGard® XL Monitor.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Single Loop Analogue addressable fire control Panel
High Sensitivity Smoke Detection
4 May I/O Control. 4 May What is I/O Control? A Doors feature that allows you to program input events to drive output responses – for example:
ECP Extinguishing Control Panel. Extinguishing Control Panel General overview Technical overview.
World Class Leaders in Fire Detection for over 75 years.
An Introduction to the R3 19 inch Rack The R3 control system comprises a number of different plug in modules, each of which is dedicated to a particular.
HP900 (ESP Protocol) Analogue Addressable Control Panels
The Exacta ® Plus Process Control System. Exacta ® Plus Designed to increase the efficiency of jobs that require multiple tasks, such as audits and sequential.
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
NFS System Components & Installation.
CB200 Conventional Control Panels
11 INSTALLING AND MANAGING HARDWARE Chapter 6. Chapter 6: Installing and Managing Hardware2 INSTALLING AND MANAGING HARDWARE  Install hardware in a Microsoft.
2 December, 2015 New Conventional Fire Control Panel.
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
The Next Generation HSSD HART XL. Why Hart XL Aspirating Smoke Detection? l Earliest detection to enable business continuity l Extra time is required.
Precept Marine Conventional Control Panels
CB200 e Cabinet Extinguishant Control Panels Designed for cabinet extinguishant systems 2 zone extinguishant co-incidence operation Selectable discharge.
User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View.
FireClass Addressable FC501 Part 2 - Panel Use. FC501 Engineering 3 in 1 Loops Up to 400mA current dynamically shared across 3 loop circuits Two versions.
Confidential Document 1 EverAccess Product Overview By Rodney Guinto.
Puissant Panel User Training Esc.. 09:11:35 ACTIVE # * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE.
Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
User Operation Presentation
Advisor Advanced Release FW120.
Feature Benefit Feature Benefit Feature Benefit Feature Benefit
Technician Operation Presentation
Total HVAC Control from anywhere Easy control that can save a fortune
Honeywell Fire Systems Group RFX SLC L1: Det.159 Mod. 159 SLC L2: Det.159 Mod. 159 SLC L3 ~ L10 EIA 485 EIA 232 RDP Up to 32 Noti-Fire-Net Onyxworks.
Presentation transcript:

Xplorer 1-2 Loop Analogue Addressable Control Panels From 1-2 loops EN54 2 & 4 Compliance Fully compatible with all Apollo XP95 and Xplorer devices Extensive threshold-change options by 7-day, day-night programme Programmable loop sounder capability Easy configuration – Default loop outputs to “on” in fire option Optional Windows-based, full upload/download PC software package

Xplorer 1-2 Loop Analogue Addressable Control Panels 500mA output per loop with highly stable voltage platform, even under mains-failed conditions Day/Night delay of alarm and cause/effect outputs 4 Inbuilt Software Delay Timers Automatic recognition of Apollo and Control Equipment outstations User friendly controls and a clear, unambiguous screen Complies with EMC and LVD Directives

Xplorer Panel Hardware Up to 31 8-way panel enhancement boards may be added. Two types are available: 1) fully-programmable inputs and relay outputs 2) fully-programmable inputs and alarm outputs Up to 31 8-way panel enhancement boards may be added. Two types are available: 1) fully-programmable inputs and relay outputs 2) fully-programmable inputs and alarm outputs Up to 14 fully functional repeater panels may be connected via RS485 cable. The panel may be programmed using the “on board” controls and/or Windows PC package. XP95 and Xplorer high capacity loops fully supported by Excel based design package

Mechanical Assembly Motherboard and power supply located on a removable chassis to assist cabinet installation. Zonal LEDs and optional printer are located on the display board. Motherboard holds up to 2 loop cards Space for internal 12Ah battery set. Power Supply. Display assembly located on the removable door.

Cabinet Options For details of panel dimensions see Application Guide. For details of panel dimensions see Application Guide. Surface Cabinets Cabinet colour reference is: RAL 7035 textured (Light Grey) All cabinets are manufactured from sheet steel and finished in satin texture epoxy powder stove paint. Semi-Flush Cabinets (Illustrated) The semi-flush bezel locates to the rear of the bevelled edge of the back box, leaving the bevelled edge and door raised out from the wall. It is finished in the same colour as the back box and is fitted by means of pinch bolts, thus avoiding the need to drill the cabinet. Fully Flush Cabinet Custom-made to a high quality, full-flush bezels are available in brass, stainless steel, or painted. This option is achieved by fixing a flat bezel assembly to the standard back box, replacing the standard door. The panel comes with assembly already fitted but may be supplied for later on-site fitting (this may be a little time- consuming). Surface Cabinets Cabinet colour reference is: RAL 7035 textured (Light Grey) All cabinets are manufactured from sheet steel and finished in satin texture epoxy powder stove paint. Semi-Flush Cabinets (Illustrated) The semi-flush bezel locates to the rear of the bevelled edge of the back box, leaving the bevelled edge and door raised out from the wall. It is finished in the same colour as the back box and is fitted by means of pinch bolts, thus avoiding the need to drill the cabinet. Fully Flush Cabinet Custom-made to a high quality, full-flush bezels are available in brass, stainless steel, or painted. This option is achieved by fixing a flat bezel assembly to the standard back box, replacing the standard door. The panel comes with assembly already fitted but may be supplied for later on-site fitting (this may be a little time- consuming).

User display The backlit LCD display gives information of loop, device and zone number, device type and event condition, together with a user-definable text description. System LED indications are provided in addition to the LCD display. The text descriptions give the user clear, easy-to use functional controls. The engineer accesses panel configuration functions using the numerical designations. The menu structure on the LCD display guides the engineer through the different set-up facilities.

LCD Display The device types which may be indicated are as follows: SOU- Loop sounder/sounder circuit controller O/S - Input/Output device ION- Ionisation smoke sensor MON- Monitor (zone monitor, control monitor) OPT- Optical smoke sensorHEAT - Heat sensor BGU- Call point or call point monitor The device types which may be indicated are as follows: SOU- Loop sounder/sounder circuit controller O/S - Input/Output device ION- Ionisation smoke sensor MON- Monitor (zone monitor, control monitor) OPT- Optical smoke sensorHEAT - Heat sensor BGU- Call point or call point monitor

Printer Hinged access to allow easy ribbon change. This good quality printer uses a reliable Epson mechanism. Designed for easy replacement of the paper roll onto the carrier. This button advances the paper. Open access to feed paper through mechanism. Engineer’s printer test button.

A Way Relay Board RS485 comms from panel motherboard. 8 inputs may be normally open or normally closed and will register as fire or non-fire on the panel as configured. Inputs are fully programmable via the panel or PC cause/effect. 24V DC power. 8 x 1Amp changeover relay outputs may be fully programmed via the panel or PC cause/effect programme. Engineer’s DIL switches to set board address, enable O/C or S/C inputs and disable inputs/outputs. Engineer’s links to disable functions for set-up or maintenance purposes.

A Way Alarm Board Engineer’s buzzer disable link for set-up or maintenance purposes. 8 x 1Amp two- stage alarm outputs may be fully programmed via the panel or PC cause/effect. Engineer’s DIL switches to isolate alarm outputs individually. 8 normally open inputs which will register as fire or non-fire on the panel as configured. Inputs are fully programmable via panel or PC cause/effect. 24V DC power. Test alarms when switched to 0V. Alarm Fault LEDs. RS485 comms from panel motherboard. Engineer’s DIL switches to set board address, disable inputs and outputs, test LEDs and test alarms.

Extensive User’s Menu User Functions Time/Date Delay Delay Enable/Disable Day/Night Modes Enable Day/Night/Auto/Off Enable/Disable Devices Zones Printer Sounders View View Event Log View Suppressed Events Test Point Walk Test Alarm Walk Test Print Clear Print Queue Print Event Log Print Disablements User Functions Time/Date Delay Delay Enable/Disable Day/Night Modes Enable Day/Night/Auto/Off Enable/Disable Devices Zones Printer Sounders View View Event Log View Suppressed Events Test Point Walk Test Alarm Walk Test Print Clear Print Queue Print Event Log Print Disablements User function to operate one man device test and alarm audibility test. User function to select the DAY mode, NIGHT mode, AUTO mode via timer, or OFF (XP95 default settings). User function to read the output delay and to enable or disable its operation. User functions to disable individual loop devices, a range of devices, full zones, the printer and sounders.

Overview of the Engineer’s Menu 1. PANEL SETUP 1. LOOP SETUP 1. Loop Configuration 1. Loop Contents 1. View Loop Contents 2. Print Loop Contents 1. Reconfigure Loop 2. Device Sensitivity 1. Fire 2. Alert 2. Zone Allocation 1. Edit Device Zones 2. Print Device Zones 3. View Device Zones 1. PANEL SETUP 1. LOOP SETUP 1. Loop Configuration 1. Loop Contents 1. View Loop Contents 2. Print Loop Contents 1. Reconfigure Loop 2. Device Sensitivity 1. Fire 2. Alert 2. Zone Allocation 1. Edit Device Zones 2. Print Device Zones 3. View Device Zones 3. Loop Cause Effect 1. Device Group Allocation 1. Edit Device Groups 2. Print Device Groups 3. View Device Groups 2. Loop Output C/E 3. Print Loop O/P C/E 2. I/O SETUP 1. Remote Evacuate Mode 2. TEXT EDIT 1. EDIT COMPANY NAME 2. EDIT Device TEXT 3. Loop Cause Effect 1. Device Group Allocation 1. Edit Device Groups 2. Print Device Groups 3. View Device Groups 2. Loop Output C/E 3. Print Loop O/P C/E 2. I/O SETUP 1. Remote Evacuate Mode 2. TEXT EDIT 1. EDIT COMPANY NAME 2. EDIT Device TEXT

Windows-based PC Programming Windows-based PC programming package for panel set up, zones, text, local and network cause/effect, Discovery mode types, sensitivity levels and day/night timings.

Repeater The backlit LCD display gives information of loop, device and zone number, device type and event condition, together with a user-definable text description. System LED indications are provided in addition to the LCD display. The text descriptions give the user clear, easy-to use functional controls. The repeater panels are available with local power supply, printer and zone LED’s if required

XP95 Test Tool The XP95 Test Tool is an engineer’s tool to assist with commissioning and fault finding on XP95 loop systems. Loop configurations and the status of each device may be interrogated, device LEDs may be turned on/off. The test tool may be connected to an entire loop without the panel connected or connected to individual devices around the circuit. The XP95 Test Tool is an engineer’s tool to assist with commissioning and fault finding on XP95 loop systems. Loop configurations and the status of each device may be interrogated, device LEDs may be turned on/off. The test tool may be connected to an entire loop without the panel connected or connected to individual devices around the circuit. Alpha-numeric LCD display. Engineer’s keypad. On/off switch and LED indication. Battery charger socket. Sockets for flying leads to connect to loop and/or individual XP95 devices.