Spectrophotometer.
Advertisements

The visible-UV spectrometer we use permits the quantitative determination of the absorption and transmission of light in the wavelength range 200 nm*
Use of the Spectronic 20 Spectrophotometer
Investigation 1 What is the relationship between the concentration of a solution and the amount of transmitted light through the solution?
Spectrophotometers and Concentration Assays
بسم الله الرحمن الرحيم UMM AL-QURA UNIVERSITY Faculty of Medicine Dep. Of BIOCHEMISTRY.
UV–Vis Molecular Absorption Spectrometry Chapter 13.
Ultraviolet – Visible Spectrophotometer. What is UV – Vis spectroscopy? Ultraviolet – visible spectroscopy is a measure of the absorbance of radiation.
INTRODUCTION TO SPECTROPHOTOMETRY
COLORIMETRYCOLORIMETRY Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit Note: A printed description of.
5 Components Common to All Optical Spectrometers Source Transparent Sample Holder Wavelength Selector Radiation Detector Signal Processor and Readout.
Let’s Talk About Beer Beer’s Law and Concentrations.
Experiment : Solutions Preparation, Part 2
Colorimetry & Spectrophotometry.
Spectrophotometer Prof.Dr. Moustafa M. Mohamed Vice Dean Faculty of Allied Medical Science Pharos University in Alexandria, EGYPT.
spectrophotoMETER Dr. Beenish Zaki, Instructor
PERKIN-ELMER MODEL 200 UV-VIS SPECTROPHOTOMETER OPERATING INSTRUCTIONS.
Spectroscopy Light in chemistry. The Nature of Light Acts as both a particle and a wave Photoelectric effect only explained through waves Interference,
Dilution and Spectroscopy Lab Lab Word Document Lab Word Document.
Simple Double Beam Spectrometer
Simple Double Beam Spectrometer
Visible Spectrophotometer
SPECTROPHOTOMETRY IN BIOTECHNOLOGY
(glass pipette, centrifuge, spectrophotometry)
Electromagnetic radiation travels through space in the form of a wave, with the distance between two crests of a wave termed a wavelength. At one end.
Exp. 18: Spectrophotometric Analysis: Concentration of a Solution Using Beer’s Law White light violet (400nm) – red (800nm) “visible spectrum” sample (light.
SPECTROSCOPY. Kendall Olds Derrick Woods Ricketta Johnson Carl Flowers.
Spectrophotometry.
Spectrofuorometer lab. 1. Fluorescence spectroscopy or (spectrofluorometry) Is a type of electromagnetic spectroscopy which analyzes fluorescence from.
Dr. Beenish Zaki, Department of Biochemistry.  When the white light passes through a coloured substance, a portion of it is absorbed by the colouring.
Spectrophotometer.
SPECTROPHOTOMETRY. Principle : there is interaction between the light and sample particle, spectrophotometer is employed to measure the amount of light.
CLS 332 CLINICAL INSTRUMENTAL ANALYSIS. A VISIBLE ABSORPTION SPECTROMETER.
QUANTITATIVE ANALYSIS Determining amount of ions present in samples.
Spectrophotometry Ability of molecules to absorb and transmit light energy is the basis of one of the most widely used procedures for determining the concentration.
Beer’s Law and Concentrations
Photometry.
QUANTITATIVE ANALYSIS Determining amount of ions present in samples.
Experiment 33 Colorimetric Determination of Iron CHE1181.
Menu Lamps provide the light in the ultraviolet/visible light spectrophotometer.
Fluorometric determination of riboflavin
Experiment: Solutions Preparation, Part 1 1CHE116.
Spectrophotometry at a Glance
COLORIMETRY & SPECTROPHOTOMETR
Lab1 A VISIBLE ABSORPTION SPECTROMETER. -One of the simplest and most widely used methods to determine concentration of a substance in solution -Measures.
C ONCENTRATION AND D ILUTION. D EFINITIONS Solute -the minor component of a solution; dissolved in the solvent; usually solid or liquid Solvent -the component.
Spectrophotometry Measuring Concentrations of Substances in Body Fluids.
Simple Double Beam Spectrometer
Lab1 A VISIBLE ABSORPTION SPECTROMETER
SPECTROPHOTOMETRY White light contains all wavelengths of light in the visible region of the EM. A substance appears colored because it absorbs light.
Spectrophotometer - Visible Type Spectro - photometer consists of two instruments : Spectrometer   Photometer  Spectrometer   for producing light.
Fundamental Techniques and Measurements
Introduction to Spectrophotometry
Colorimetric Determination of Iron
Spectrophotometric Determination [Co2+]
Spectrophotometer Dr . S. Jayakumar.
Measurements involving light –A Basic Principles and Instrumentation
SPECTROSCOPY.
SPECTROPHOTOMETRY White light contains all wavelengths of light in the visible region of the EM. A substance appears colored because it absorbs light.
SIDEBAR: PLANTS ABSORB A LOT OF LIGHT ENERGY…
INTRODUCTION TO SPECTROPHOTOMETRY
Cu2+ + 4NH3 → Cu(NH3)42+ (deep blue)
Beer’s Law and Concentrations
Let’s Talk About Beer’s Law
Electrophoresis: Movement of a solid phase with respect to a liquid (buffer) Sample is applied to the medium and under the effect of electric field, group.
Let’s Talk About Beer’s Law
Solution Preparation Experiment
Spectrophotometry A method to determine concentration of a species exploiting the absorption of EMR.
Microbiology 345: Using an Ultraspec UV-vis recording spectrometer
Clinical instrumental analysis
Presentation transcript:

Spectrophotometer(2) Prof.Dr. Moustafa M. Mohamed

Spectrophotometer The spectrophotometer measures light absorption by a liquid substance at various wavelengths. The components of an unknown material can be determined or the concentration of a number of known substances can be measured.

A monochrometer uses a diffraction grating or prism to disperse the light from the lamp (slit S 1 ). The light is broken into its spectral components as it arises from slit S 2 and falls on the sample in the cuvette, The angle of the diffraction grating determines light wavelength. The mirror reduces equipment size.

light output, photodetector sensitivity, and sample substance absorbance changes with wavelength, and this necessitates zero calibration for each wavelength measurement. The double-beam spectrophotometer accomplishes this automatically by beam path switching (sample to reference) via a mechanical shutter or rotating mirror.

Maintenance Maintenance includes: Calibration adjustment and replacement of light source bulbs and photo detectors. Mechanically rotating assembles (mirrors, diffraction grating) will occasionally malfunction. The electronics is very reliable.

General Operating Instructions

Turn on Spectrophotometer Turn the Power Switch Clockwise Allow the spectrophotometer to warm up for at least fifteen minutes to stabilize the source and detector before proceeding.

Set the Display Mode to TRANSMITTANCE Press the MODE CONTROL Until the LED beside TRANSMITTANCE is lit

Adjust the display to 0% TRANSMITTANCE With the Zero Control Knob.

Set the desired WAVELENGTH By Adjusting the Wavelength Control

Prepare Blank Fill clean cell with solvent and wipe the cell with a tissue to remove liquid droplets, dust, and finger prints. Place the cell firmly into the sample compartment, aligning the guide mark on the cell with the guide mark at the front of the sample compartment.

Adjust Transmittance to 100% Close the sample compartment Lid Adjust the Transmittance knob until the display reads 100.

Check Absorbance Press Mode Control Switch until LED besides ABSORBANCE is lit. The display should read

The machine response changes EVERYTIME you change the WAVELENGTH You must reset the 100% Transmittance EVERYTIME you change the WAVELENGTH

Making Sample Measurements Rinse the sample cell twice with a small amount of solution. Wipe cell with tissue and place in the sample compartment.

Read the Absorbance Align the guide marks and close the lid. Read the absorbance on the display. Remove the cell from sample compartment.

If you must change the WAVELENGTH, you must reset the BLANK ABSORBANCE at the new wavelength

Can You Identify the Parts? #1 #3#8 #6 #7 #4 #5 #2