World Leaders in Combustion Management Solutions Taiwan 2012 www.autoflame.com introduction.

Slides:



Advertisements
Similar presentations
PPC4000 COMBUSTION EFFICIENCY SYSTEM
Advertisements

Preferred Instruments CB-Hawk Replacement System Based on BurnerMate TS Technology A low-cost upgrade for obsolete CB-Hawk systems.
340 Voyager rooftop range Dual Fuel DKD/H Voyager II Voyager III kW Heat Pump Cooling Only Gas Fired
Copyright© 2014 Austin Analytics Group, LLC. Stand Alone System High Temperature System Hazardous Area System Universal/Remote Display System Copyright©
BurnerMate TS Overview
Nano-10 based Building Automation System (BAS) Jesús BaezMarch, 2011.
MAGNA3 – “built on a proven foundation”
BurnerMate Universal A Complete Boiler Control System.
1 Direct Fired Gas Heating Presented by Jim Jagers of Applied Air.
Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters ­Maximum Boiler Design Pressure  All Models – 160 Psig ­Maximum.
E VERY L IFE H AS A P URPOSE… Flame Detection Theory.
E VERY L IFE H AS A P URPOSE… FlameGard 5 UV/IR Flame Detector The Benefits of HART on Installation and Maintenance of Flame Detectors.
Engineer Presentation
High Efficiency Commercial Gas HCG Series. 2 American HCG Series The HCG Series High Efficiency Commercial Gas Water Heaters embody all that’s great about.
Introducing GAC’s New Line of Intelligent Generator Set Controllers
Introducing GAC’s New Line of Intelligent Generator Set Controllers.
Introducing GAC’s New Line of Intelligent Generator Set Controllers
1 VACUUM ATMOSPHERES Co NEW PRODUCT ANNOUNCEMENT November 28, 2001.
Energy Management with the use of an Intelligent Building Management System.
UTSW Thermal Energy Plants, Power Generation and Electrical System What do we do to meet the Emission Reduction, Energy usage Reduction and Electrical.
5 Gas Analysis Another Rainharbor Production 1997.
 Install new air cooled high efficiency screw chiller (variable speed)  Install new fan coils with ECM motors and low temperature heating coils and proper.
SCADA and Telemetry Presented By:.
Jeremy Harris Simultaneous Reduction of PM, NOx, HC & CO From Large Stationary Diesel Engines March 21, 2006.
RO400FC Forced convection hot air reflow oven. In a flexible production, what do you need for soldering of  Complex PCB’s  Soldering of fine pitch on.
BOILER PLANT OPERATION Presented By Mr. Sivanand Ray
BODHPS PROTOTYPE B Testing and Documentation of improved prototype with a record of power output.
BioWin ®. Bio Gas – The alternative energy source of the future! BioWin ® - Bio Gas Analysis of the future!
Burners TRAining CEntre. RESIDENTIAL GAS BURNERS R D B R D B series GOALS: KEEP STRONG OUR POSITION ON RESIDENTIAL GAS BURNERS DEDICATED TO OEM’s MARKET.
MCS’S MAGNUM DIAGNOSTICS PACKAGE Visit us at
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
LDA Large Display for Analog Inputs. Agenda What is the LDA? Easy programming About the input Setpoint control Communication Other features Packaging.
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
World Leaders in Combustion Management Solutions OverviewExplanationFurther Information Application Further Information Explanation Introduction Application.
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
World Leaders in Combustion Management Solutions PID Control (P)roportional (I)ntegral Internal Stat PID (D)erivative Further.
World Leaders in Combustion Management Solutions Training School Autoflame Training 2013 PID.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
World Leaders in Combustion Management Solutions ModuleScreenshots Normal Operation Features Commissioning The Mk7 MM System.
New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (D.T.I.) THE MK7 DATA TRANSFER.
New Product Developments World Leaders in Combustion Management Solutions Mk7 Expansion PCB Mk7 Expansion PCB.
Roof Top Unit Overview (MAGNUM) Visit us at Revision- 12/17/2015.
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
World Leaders in Combustion Management Solutions Module Gas Setup Introduction The Mk7 E.G.A Cell Status Further Information.
New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Autoflame Training 2014.
New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers C.E.M.S., MCERTs.
World Leaders in Combustion Management Solutions ModuleScreenshots Gas Setup Sampling The Mk7 E.G.A Cell Status Further Information.
Intelligent Boiler Sequencing
New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers C.E.M.S., MCERTs.
World Leaders in Combustion Management Solutions Water Level System Autoflame Training Water Level System.
New Product Developments World Leaders in Combustion Management Solutions New Products New Products.
CUE – Make Any Pump an E-Pump
World Leaders in Combustion Management Solutions New Product Developments Autoflame Sales Meeting 2011 New Product Developments.
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
World Leaders in Combustion Management Solutions Mini Mk7 Evolution Autoflame Training Mini Mk.7 Evolution.
World Leaders in Combustion Management Solutions End User Guide Lockout Codes Pressure Sensors Error Codes Flame Safeguard UV.
OE OXYGEN ENRICHED BURNER
World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI Autoflame Training,
An overview of I&C Systems in APR 1400 Parvaiz Ahmed Khand December 28, 2007.
BurnerMate TS Overview. PREFERRED UTILITIES MFG CORP South St. Danbury CT T: (203) F: (203) www. PREFERRED-MFG.com.
UtilitySaver Overview. PREFERRED UTILITIES MFG CORP South St. Danbury CT T: (203) F: (203) www. PREFERRED-MFG.com.
World Leaders in Combustion Management Solutions OverviewExplanationFurther Information Application Further Information Explanation Introduction Application.
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
Overview Of Autoflame. Schedule Overview of Autoflame products – MM Controls: Mk8 & Mini Mk8 – Exhaust Gas Analyser (EGA) – Data Transfer Interface (DTI)
Process Safety Advisory on Boiler Incidents
Ranger Combustion System
Heat-Timer Control Options
High Pressure screw compressor
Roof Top Unit Overview (MAGNUM)
Presentation transcript:

World Leaders in Combustion Management Solutions Taiwan introduction

World Leaders in Combustion Management Solutions Taiwan Autoflame System Schematic from the basic Mini Mk7 to Mk7 Evolution

World Leaders in Combustion Management Solutions Taiwan

World Leaders in Combustion Management Solutions Taiwan

World Leaders in Combustion Management Solutions Taiwan

World Leaders in Combustion Management Solutions Taiwan

World Leaders in Combustion Management Solutions Taiwan

World Leaders in Combustion Management Solutions Taiwan

World Leaders in Combustion Management Solutions Taiwan

World Leaders in Combustion Management Solutions Taiwan

World Leaders in Combustion Management Solutions Taiwan

World Leaders in Combustion Management Solutions Taiwan

World Leaders in Combustion Management Solutions Taiwan

World Leaders in Combustion Management Solutions Taiwan

World Leaders in Combustion Management Solutions Taiwan

World Leaders in Combustion Management Solutions Taiwan

World Leaders in Combustion Management Solutions Taiwan

World Leaders in Combustion Management Solutions Taiwan

World Leaders in Combustion Management Solutions Taiwan System Components.

World Leaders in Combustion Management Solutions Taiwan Flame detection End view & side view UV. Self checking UV. Infra-red flame monitoring. Redundancy dual scanners. High sensitivity scanners External indication flame signal strength.

World Leaders in Combustion Management Solutions Taiwan Fully stainless steel application Dual self checking UV scanner air cooling Redundant Mk.7 controls Preheat Combustion Air Applications

World Leaders in Combustion Management Solutions Taiwan Large and small servos From 1.2 to 15 Nm From 0.89 to 11 ft.lbs NEMA 13 ATEX Industrial servos From 42 to 400 Nm From 30 to 295 ft.lbs NEMA 4 Servo motors

World Leaders in Combustion Management Solutions Taiwan Combustion Management Systems Fuel Control Valves

World Leaders in Combustion Management Solutions Taiwan Material All Stainless steel body Stainless steel bobbin Formats Metering Spill-back/bypass

World Leaders in Combustion Management Solutions Taiwan Material Aluminum body Stainless steel drive shaft and stainless steel disc as standard Fitting Screwed 0.5” to 3” NPT/BSP Flanged 2” to 6” 150lb/PN16 FGR stainless steel valves, c/w grease point

World Leaders in Combustion Management Solutions Taiwan Water Temperature Sensor 0 to C 0 to F Steam Pressure Sensor 0 – 45 PSI (3.8Bar) 0 – 267 PSI (23Bar) 0 – 445 PSI (38Bar) 0 – 1500 PSI (100Bar) 3 rd Party Sensor Voltage signal

World Leaders in Combustion Management Solutions Taiwan Combustion Management Systems Air pressure sensor 0 – 1 PSI (65mBar) 0 – 2 PSI (130mBar) Gas pressure sensor 0 – 1 PSI (65mBar) 0 – 5 PSI (340mBar) 0 – 11 PSI (750mBar) 0 – 20 PSI (1380mBar) 0 – 60 PSI (4Bar) Oil pressure sensor PSI (40Bar)

World Leaders in Combustion Management Solutions Taiwan Mk.7 Micro Modulation Controller Micro Modulation Fuel/Air ratio control UV or IR self check flame safeguard Burner safety control Gas Valve Proving Gas, oil and air pressure proving Precise target setpoint control FGR Management Lead lag control (steam and hot water) 3 Parameter Trim, O 2, CO 2 & CO Water Level Control (independent PID) 15 Programmable First-Out Annunciation points Draft control (independent PID)

World Leaders in Combustion Management Solutions Taiwan Mk.7 Display Features

World Leaders in Combustion Management Solutions Taiwan Mk.7 Display Features

World Leaders in Combustion Management Solutions Taiwan Multi-lingual Display: –English –Chinese –Spanish –French –German –Dutch –Danish –Czech –Polish Any language may be added on request Multiple Language Display

World Leaders in Combustion Management Solutions Taiwan Independently controlled fuel and air positioning motors with an accuracy of 0.1 of and angular degree 4 separate fuel curves 4 dedicated servo drives 2 dedicated variable speed drives Selectable trim channel (damper of VSD) Error diagnostic codes displayed Single point change facility for commissioned fuel/air ratio User definable optimum ignition position FGR Management, delay from start-up to enable FGR until flue gas temp., boiler setpoint or time delay achieved Micro Modulation Fuel/Air Ratio Control

World Leaders in Combustion Management Solutions Taiwan Flame Safeguard safety features Full flame supervision with UV self-check for continuous operation, patented self adaptive UV amplification Burner control functions with user configurable timings Gas valve proving system with on-line pressure supervision Oil pressure monitoring and display with limit checks Air windbox pressure proving – display and supervision Lockout history of last 16 incidents with date, time, function and reset Burner control functions (Flame Safeguard) selectable

World Leaders in Combustion Management Solutions Taiwan Setpoint Control Features (PID) Internal 3 tern PID control to required setpoint for both pressure and temperature Second setpoint user adjustable Time clock facility, reduced setpoint and off modes External 4-20mA input for setpoint control

World Leaders in Combustion Management Solutions Taiwan Setpoint Control Features (PID) Fuel flow metering Hand/Auto/Low flame hold facilities 4-20mA input for external load control 4-20mA output of firing rate Twin burner and multi-burner control capability

World Leaders in Combustion Management Solutions Taiwan Economiser monitoring

World Leaders in Combustion Management Solutions Taiwan Economiser heat recovery

World Leaders in Combustion Management Solutions Taiwan Data Transfer Interface

World Leaders in Combustion Management Solutions Taiwan Mk.7 Data Transfer Interface Remote control Knowing your energy costs Historical record of performance Continuous emissions monitoring

World Leaders in Combustion Management Solutions Taiwan Mk.7 Data Transfer Interface (D.T.I.) Gateway for communicating with the Autoflame range of products Collects and stores information from up to: Information gathered from these units are available through either an Ethernet or RS422 connection Information gathered by the D.T.I. can be viewed over a Local Area Network, or oven an internet connection Data collection/monitoring can be done either via Modbus, or by using the included Autoflame CEMS Auditing Software  10 x M.M. units  10 x E.G.A.’s  10 x I/O modules

World Leaders in Combustion Management Solutions Taiwan Mk.7 D.T.I. Features & Benefits Up to 2 years of data is collected, displaying: 24 hours of data collection to display: Viewable animated Mk.7 M.M., Mini Mk.7 M.M. & Mk.7 E.G.A. screens Incorporate additional equipment to the Autoflame system with the Mk.7 I/O modules  Firing rates  Actual or Required Pressures/Temperatures  Servo positions  Exhaust Gas data  Water Level data  Lockouts/Errors/First Outs  Gas/Air/Oil pressures  Sequencing data  TDS Values

World Leaders in Combustion Management Solutions Taiwan Historical data logged via DTI

World Leaders in Combustion Management Solutions Taiwan Historical data logged via DTI

World Leaders in Combustion Management Solutions Taiwan Steam flow data logged via DTI

World Leaders in Combustion Management Solutions Taiwan Do you have the correct water chemistry?

World Leaders in Combustion Management Solutions Taiwan Knowing your energy costs

World Leaders in Combustion Management Solutions Taiwan Remote information available to the client

World Leaders in Combustion Management Solutions Taiwan Available Information – M.M. The following information is available through the D.T.I. on the touch- screen, the C.E.M.S. Audit Software, and is output via Modbus: Required/Actual boiler temperature/pressure Burner maximum firing rate, burning firing rate (%) Fuel selected, flow metering values Number of servos, position historys Number of VSD’s, output and feedback history Maximum/Minimum set point accepted by D.T.I. Burner firing status (off, firing, purge, ingnition, offline etc) Sequencing status, shuffle sequencing and lead boiler status Enabled/Disabled status Lockouts, error and first out status

World Leaders in Combustion Management Solutions Taiwan Available Information – E.G.A. The following information is available through the D.T.I. on the touch- screen, the C.E.M.S. Audit Software, and is output via Modbus as instantaneous data: O 2, CO 2, CO, NO, SO 2 and NO 2 percentile & ppm values Exhaust gas temperature Ambient temperature Combustion efficiency E.G.A. warning and error conditions

World Leaders in Combustion Management Solutions Taiwan Mk.7 D.T.I. on a Modbus Network

World Leaders in Combustion Management Solutions Taiwan D.T.I. - Ethernet Network & C.E.M.S Auditing Software

World Leaders in Combustion Management Solutions Taiwan System Schematic

World Leaders in Combustion Management Solutions Taiwan Live link to Coca Cola UK