The improvement of the energy resolution in epi-thermal region of Bonner sphere using boric acid solution moderator H. Ueda1, H. Tanaka2, Y. Sakurai2.

Slides:



Advertisements
Similar presentations
Combined evaluation of PFNS for 235 U(n th,f), 239 Pu(n th,f), 233 U(n th,f) and 252 Cf(sf) (in progress) V.G. Pronyaev Institute of Physics.
Advertisements

Neutron detectors and spectrometers 1) Complicated reactions → strong dependency of efficiency on energy 2) Small efficiency → necessity of large volumes.
The LENS Facility at IUCF David V. Baxter Indiana University A. Bogdanov, J. M. Cameron, P. Chen (UIUC), V. P. Derenchuk, B. Jones (UIUC), H. Kaiser, C.
EAR2 simulation update Collaboration board meeting Christina Weiss & Vasilis Vlachoudis.
UNIVERSITA’ DEGLI STUDI DI PALERMO DIN DIPARTIMENTO DI INGEGNERIA NUCLEARE CHERNE th Workshop on European Collaboration for Higher Education and.
“Neutron activation analysis on slurry resulted from waste water conditioning” INSTITUTE FOR NUCLEAR RESEARCH PITESTI – ROMANIA INSTITUTE FOR NUCLEAR RESEARCH.
Esteban Fabián Boggio 1 Lucas Provenzano 2 Sara Gonzalez 2,3 Sara Gonzalez 2,3 Juan Manuel Longhino 1 1 Bariloche Atomic Center, Atomic Energy National.
Student Practice in JINR Fields of Research Dubna Vlasta Zdychová, Martina Benešová CTU in Prague Czech Republic Pavol Blahušiak, Alexander.
Experimental Determination of Neutron Cross Sections of Yttrium by Activation Method by Barbara Geier Supervisors: Assoc. Prof Dr. Wolfgang Sprengel RNDr.
E. Bavarnegin,Yaser Kasesaz, H. Khalafi
Cross section measurements for analysis of D and T in thicker films Liqun Shi Institute of Modern Physics, Fudan University, Shanghai, , People’s.
Design on Target and Moderator of X- band Compact Electron Linac Neutron Source for Short Pulsed Neutrons Kazuhiro Tagi.
Joint IAEA-ICTP Workshop on Nuclear Reaction Data for Advanced Reactor Technologies Student’s presentation Calculation of correction factors for neutron.
Measurements of cross-sections of neutron threshold reactions and their usage in high energy neutron measurements Ondřej Svoboda Nuclear Physics Institute,
Studies of ADS by means of JINR Nuclotron Martin Suchopár Nuclear Physics Institute, Academy of Sciences of the Czech Republic Department of Nuclear Reactors,
Some fission yields for 235U (n,f), 239Pu (n,f), 238U (n,f) reactions in ΣΣ neutron spectrum Dr. Cristina Garlea National Institute for R&D of Physics.
Determination of gamma dose component in thermal column of Pavia Triga reactor by using alanine ESR detectors Saverio Altieri Department of Physics University.
G. Bartesaghi, 11° ICATPP, Como, 5-9 October 2009 MONTE CARLO SIMULATIONS ON NEUTRON TRANSPORT AND ABSORBED DOSE IN TISSUE-EQUIVALENT PHANTOMS EXPOSED.
Ion Beam Analysis Dolly Langa Physics Department, University of Pretoria, South Africa Blane Lomberg Physics Department, University of the Western Cape,
Monte Carlo Study to determine the Neutron Fluence spectrum for a water Phantom: Preliminary Results University of the Western Cape Energy Postgraduate.
16 th International Congress on Neutron Capture Therapy June 14-19, Helsinki, Finland Improvement of a PGNAA Facility for BNCT in THOR C. K. Huang 1, H.
Future usage of quasi-infinite depleted uranium target (BURAN) for benchmark studies Pavel Tichý Future usage of quasi-infinite depleted uranium target.
European Physical Society 19 th Nuclear Physics Divisional Conference New Trends in Nuclear Physics Applications and Technology Pavia (Italy) September.
Studies of neutron cross-sections by activation method in Nuclear Physics Institute Řež and in The Svedberg Laboratory Uppsala and experimental determination.
Experimental studies of spatial distribution of neutron production around thick lead target irradiated by 0.9 GeV protons Antonín Krása&Vladimír Wagner.
M. Manolopoulou 1, M. Fragopoulou 1, S. Stoulos 1, E. Vagena 1, W. Westmeier 2, M. Zamani 1 1 School of Physics, Aristotle University of Thessaloniki,
Simulations on “Energy plus Transmutation” setup, 1.5 GeV Mitja Majerle
Spectra of the Thunderstorm Correlated Electron and Gamma-Ray Measured at Aragats Bagrat Mailyan and Ashot Chilingarian.
Status on 25 Mg(n,  ) and neutron flux in 2012 Bologna, 27 November 2013 C. Massimi.
Systematic studies of neutrons produced in the Pb/U assembly irradiated by relativistic protons and deuterons. Vladimír Wagner Nuclear physics institute.
Cross-sections of Neutron Threshold Reactions Studied by Activation Method Nuclear Physics Institute, Academy of Sciences of Czech Republic Department.
Production & Measurement of Thermal Neutron at RCNP Chhom Sakborey Nguyen Thi Duyen An Tran Hoai Nam Li Chunjuan Wang Mian.
Neutron Flux Measurement at the CYRIC T. Horiguchi and A. Ishikawa (Tohoku University) For the FPCCD group.
ThEC13, Geneva, 28th-31st Oct., 2013 C. H. Pyeon, Kyoto Univ. 1 Cheolho Pyeon Research Reactor Institute, Kyoto University, Japan
Experimental Studies of Spatial Distributions of Neutrons Produced by Set-ups with Thick Lead Target Irradiated by Relativistic Protons Vladimír Wagner.
Ondřej Svoboda Nuclear Physics Institute, Academy of Sciences of Czech Republic Department of Nuclear Reactors, Faculty of Nuclear Sciences and Physical.
Surface Effects and Retention of Steady State 3 He + Implantation in Single and Polycrystalline Tungsten S.J. Zenobia, G.L. Kulcinski, E. Alderson, G.
A NEUTRON IRRADIATION DEVICE FOR THE TESTING OF MICROELECTRONIC COMPONENETS TO BE USED IN THE RADIATION ENVIRONMENT OF HIGH-ENERGY PARTICLE ACCELERATORS.
M. Štefánik *), P. Bém, M. Honusek, K. Katovský, M. Majerle, J. Novák, and E. Šimečková AER Working Group F – „Spent Fuel Transmutation“ and INPRO IAEA.
N_TOF commissioning INTC-P-249 Spokespersons: J.L.Tain, V.Vlachoudis Contactperson: V.Vlachoudis th Nov 2009 for the n_TOF collaboration.
Ondřej Svoboda Nuclear Physics Institute, Academy of Sciences of Czech Republic Department of Nuclear Reactors, Faculty of Nuclear Sciences and Physical.
Neutron production in Pb/U assembly irradiated by deuterons at 1.6 and 2.52 GeV Ondřej Svoboda Nuclear Physics Institute, Academy of Sciences of Czech.
Neutron production in Pb/U assembly irradiated by 1.26 AGeV deuterons. First experimental results Ondřej Svoboda Neutron production in Pb/U assembly irradiated.
Grup de Física de les Radiacions 24 th International Conference on Nuclear Tracks in Solids CALIBRATION OF THE UAB PADC BASED NEUTRON DOSEMETER Measurements.
Design of novel GEM-based neutron spectrometer E. Aza 1,2* 1 CERN, 1211 Geneva, Switzerland, 2 AUTH, Department of Physics, Thessaloniki, Greece,
Overview of the BNCT neutron beam line facility in NRI Rez (Prague) Most pictures taken from presentation of J.Burian/NRI – Milano09 1 NRI = Nuclear research.
Institute of Experimental and Applied Physics Czech Technical University in Prague IEAP – CTU Prague 1 BrightnESS T4.1 Meeting Activity at IEAP CTU in.
Albert Riego, Guillem Cortes, Francisco Calviño July 22 th, 2015 Universitat Politecnica de Catalunya, Barcelona (Spain) Third BRIKEN WORKSHOP – IFIC (Valencia,
N_TOF EAR-1 Simulations The “γ-flash” A. Tsinganis (CERN/NTUA), C. Guerrero (CERN), V. Vlachoudis (CERN) n_TOF Annual Collaboration Meeting Lisbon, December.
Three years of cross-section measurements of (n,xn) threshold reactions at TSL Uppsala and NPI Řež O. Svoboda, A. Krása, A. Kugler, M. Majerle, J. Vrzalová,
RadMon thermal neutron cross-section calibration D.Kramer for the RadMon team L.Viererbl, V.Klupak NRI Rez 1.
Comparison of neutron production on lead-uranium setup irradiated by protons and deuterons with different energies Ondřej Svoboda Nuclear Physics Institute,
IEAP – CTU Prague Measurement of neutron flux during irradiation in NPI Řež T. Slavíček, V. Linhart, S. Pospíšil Institute of Experimental and Applied.
Monte Carlo methods in spallation experiments Defense of the phD thesis Mitja Majerle “Phasotron” and “Energy Plus Transmutation” setups (schematic drawings)
GEANT4 Simulations of a Beam Shaping Assembly Design and Optimization for Thermal/Epithermal Neutrons Vahagn Ivanyan  Yerevan Physics Institute, Armenia.
New instruments for real-time neutron spectrometry from thermal to GeV
P. Buffa, S. Rizzo, E. Tomarchio
Cross-section Measurements of (n,xn) Threshold Reactions
Development and characterization of the Detectorized Phantom for research in the field of spatial fractionated radiation therapy. D. Ramazanov, V. Pugatch,
for collaboration “Energy plus transmutation”
PARTICLE FLUX CALCULATION-III
Mitja Majerle NPI CAS Řež, The Czech Republic
Mitja Majerle NPI CAS Řež, Czech Republic
Performed experiments Nuclotron – set up ENERGY PLUS TRANSMUTATION
Neutron production in Pb/U assembly irradiated by p+, d+ at 0. 7 – 2
Design of A New Wide-dynamic-range Neutron Spectrometer for BNCT with Liquid Moderator and Absorber S. Tamaki1, I. Murata1 1. Division of Electrical,
一种基于晶体间光分享原理的深度测量PET探测器
O. Svoboda, A. Krása, A. Kugler, M. Majerle, J. Vrzalová, V. Wagner
Aging test of glass and MRPC
Pohang Neutron Facility (First Presentation of Prof. Cho’s Class)
Presentation transcript:

The improvement of the energy resolution in epi-thermal region of Bonner sphere using boric acid solution moderator H. Ueda1, H. Tanaka2, Y. Sakurai2   1Graduate School of Engineering, Kyoto University 2Kyoto University Research Reactor Institute (Thank you) My name is Haruaki Ueda. Today, I’d like to talk to you about “The improvement of the energy resolution in epi-thermal region of Bonner sphere using boric acid solution moderator”.

Comparison of energy resolution between two types of Bonner spheres. Outline Calculation of Bonner sphere response functions using polyethylene and boric acid solution as a moderator. Comparison of energy resolution between two types of Bonner spheres. Evaluation of the neutron spectrum at Kyoto University Reactor Heavy Water Neutron Irradiation Facility ( KUR-HWNIF ) At the beginning, I'd like to show you the contents of my presentation. We are studying on the measurement of epi-thermal neutron spectrum using Bonner sphere. We used boric acid solution as a moderator of Bonner sphere to narrow a peak of response function and improve energy resolution. Firstly, I will show you the calculation results of Bonner sphere response functions using polyethylene and boric acid solution as a moderator. And, to compare energy resolution between these two types of moderator Bonner sphere, we simulated unfolding of neutron spectra consisting of a single peak in epi-thermal energy region. Secondly, I will show you the unfolding results of the neutron spectra. Finally, I will show you the estimated spectrum at KUR-HWNIF obtained from the measurement using boric acid solution moderator.

Introduction RBE of neutron greatly vary depending on its energy, especially in epi-thermal region. It is difficult to obtain the detailed information for the neutron energy spectrum in the keV region. We are improving the energy resolution of Bonner sphere, especially in the keV region, using the boric acid solution as a moderator. In epi-thermal neutron irradiation field for BNCT, neutron energy is over a wide range. Because neutron effect to tissue greatly vary depending on its energy, it is necessary to evaluate the neutron dose for each neutron energy. So, it is important to obtain the detailed information for the neutron energy spectrum before the clinical use. But, it is difficult to obtain the detailed information for the neutron energy spectrum in the keV region by activation foils, and so on. Bonner sphere is useful to evaluate the neutron spectrum in detail. We are improving the energy resolution of Bonner sphere, especially in the keV region, using the boric acid solution as a moderator

Thermal neutron detector Bonner Sphere1 moderator Next, I will explain the measurement principle of Bonner sphere. Bonner sphere consists of a spherical neutron moderator and a thermal neutron detector placed in the sphere center. Thermal neutron detector

Bonner Sphere2 2. Moderation to thermal energy 1. Incidence 3. Detection Neutron The incident neutron on a Bonner sphere is moderated to thermal neutron and detected by a thermal neutron detector placed in the sphere center. A small Bonner sphere is suitable for low energy neutron measurement and a large Bonner sphere is suitable for high energy neutron measurement. Using the various sizes of Bonner spheres, we can estimate the detailed neutron spectra for the wide energy range.

Moderator including 10B 10B Absorbed by 10B Thermal Neutron 10B Boron 10 has large absorption cross section for thermal neutron, so using material including boron 10 as a moderator , thermal neutrons are hard to detect by the Bonner sphere. And Bonner spheres using a moderator including boron 10 is relatively more sensitive to the neutrons thermalized near the sphere center than others. This leads to a narrow response function peak and the improvement of energy resolution in epi-thermal region is expected. Epi-thermal Neutron Thermalized near the center and detected

Response function calculation Thermal neutron detector Manganin foil (thickness: 200um, diameter: 2cm) Gold foil (thickness: 50um, diameter: 1cm) Response function calculation Parallel neutron beam Moderator material Polyethylene Boric acid solution ( 0.14 10B wt%) In this study, Bonner sphere consists of a spherical neutron moderator shell and activation foils placed in the sphere center as thermal neutron detector. Polyethylene and boric acid solution are used as moderator material. Generally, polyethylene is used as a moderator of Bonner sphere. Manganin and gold are used as activation foil material. We calculated the specific saturated activities per flux for each energy neutron as the response function of Bonner spheres. Calculations were performed using a Monte Carlo simulation code system, PHITS. The sphere diameters were 10, 15, 20cm Sphere diameter 10, 15, 20 cm

Calculation results The specific saturated activities per flux for each energy neutron were calculated as the response function of Bonner spheres Activation foil: Gold(197Au) The specific saturated activities per flux for each energy neutron were calculated as the response function of Bonner spheres I show you the response functions of gold foil placed in the center of Bonner sphere on graphs. D10 represents the 10cm diameter Bonner sphere. From the graphs, We can see the response function peaks of Bonner spheres using boric acid solution is narrower than those for polyethylene moderator and the improvement of the resolution is expected. Moderator: polyethylene boric acid water (0.14 10B wt%)

Unfolding test1 Examples of Neutron spectra used in the tests We performed unfolding tests for the comparison of energy resolution. Saturated activities were calculated and errors were added to the data. The data were unfolded into estimated spectrum by UMG unfolding package for each moderator Bonner sphere. Next, I explain the Unfolding test for the comparison of energy resolution. We calculated saturated activity for each Bonner sphere and add random errors to the data. Errors were normally distributed and relative standard deviation was 3%. We got a estimated spectrum from all the data of the same moderator Bonner sphere. Calculations of saturated activity were performed using synthetic neutron spectra consisting of a single peak in epi-thermal energy region. Peak width was one digit. The calculated activities were unfolded into estimated spectrum by UMG unfolding package using uniform spectrum as the default. UMG includes two types of unfolding codes, Gravel and Maxed. We used both codes. Examples of Neutron spectra used in the tests

Unfolding tests2 These graphs show the estimated spectra of the true spectrum that has the peak center at 100keV. GRV represents the estimated spectrum by gravel. MXD represents the estimated spectrum by maxed. We can see that the estimated spectra using boric acid solution as a moderator reflect the true spectrum better than those for polyethylene moderator. Moderator: polyethylene boric acid solution (0.14 10B wt%)

Unfolding test3 These graphs show the result of true spectrum that has the peak center at 10keV. Moderator: polyethylene boric acid solution (0.14 10B wt%)

Unfolding tests4 These graphs show the estimated spectra of the true spectrum that has the peak center at 1keV. Moderator: polyethylene boric acid solution (0.14 10B wt%)

Unfolding test5 These graphs show the estimated spectra of the true spectrum that has the peak center at 100eV. As shown above, We can see that the estimated spectra using boric acid solution as a moderator reflect the true spectrum better than those for polyethylene moderator. It is shown that we can improve energy resolution of Bonner sphere using boric acid solution as a moderator . Moderator: polyethylene boric acid solution (0.14 10B wt%)

Stochastic errors : 3-5% Measurement at KUR-HWNIF Bonner sphere Finally, I will show you the measurement for the epi-thermal neutron irradiation mode at KUR-HWNIF using boric acid solution moderator and the estimated spectrum obtained from the data. This is the geometry of the measurement. Bonner sphere constitute of acrylic sphere shell filled with boric acid solution or water and two foils of manganin and gold placed in the center. Boric acid concentration was 0.14 10B wt%. Sphere diamter are 10, 15, 20cm. After the irradiations, we measured the saturated activities by a High purity germanium detector. Stochastic errors are within 3 to 5 percent. Stochastic errors : 3-5%

Influence of foil placement and solution concentration Response functions were calculated based on beam data of previous study and the practical geometry at KUR-HWNIF. And for the evaluation of measurement error, we calculated response functions for the variation of activation foil placement and boric acid concentration. Unfolding simulation using these response results showed that the estimated spectrum in epi-thermal region changed by twenty and a several percentage if the foil position varied by 5mm or the boric acid concentration did by 10B 0.03wt%. The estimated spectrum in epi-thermal region changed by twenty and a several percentage if the foil position varied by 5mm or the boric acid concentration did by 10B 0.03wt%.

Estimation of KUR-HWNIF spectrum This shows the estimated neutron spectrum from calculated response functions and the measurement data by Maxed code. Guess represents the previous study data. The estimated spectrum agree with the previous study data within the error bars.

Conclusion It was confirmed that boric acid solution moderator improves the energy resolution of the Bonner sphere in the keV region. The estimated spectrum was in good agreement with the data from the previous study. The estimated spectrum in epi-thermal region changed by twenty and a several percentage if the foil position varied by 5mm or the boric acid concentration did by 10B 0.03wt%. Thank you very much for your attention.

Thank you very much for your attention.

Response Functions1 Moderator: polyethylene Activation foil: manganin(55Mn) Moderator: polyethylene Activation foil: gold(197Au)

Response Functions2 Moderator: boric acid water(0.14wt%) Activation foil: manganin(55Mn) Moderator: boric acid water(0.14wt%) Activation foil: gold(197Au)