Purpose Probe construction Field and laboratory measurements Data processing, applicational example Conclusions, outlook A NEW METHOD TO DETERMINE in.

Slides:



Advertisements
Similar presentations
Contents: Cover
Advertisements

Estimation of Borehole Flow Velocity from Temperature Profiles Maria Klepikova, Tanguy Le Borgne, Olivier Bour UMR 6118 CNRS University of Rennes 1, Rennes,
Manual Set-Up for Density by Hydrometer Method ASTM D1298, D287, D6822 and IP160 Feb
Institute of Energy and Sustainable Development Monitoring of a Large Scale Ground Source Heat Pump System - S.Naicker, Dr. Simon Rees IESD, De Montfort.
Inversion of coupled groundwater flow and heat transfer M. Bücker 1, V.Rath 2 & A. Wolf 1 1 Scientific Computing, 2 Applied Geophysics Bommerholz ,
NH 3 BASED SCREW COMPRESSOR CHILLER. We use Alfa-Laval (Sweden) make WPHEs in the evaporator as well as the condenser(optional) in the chilling system.
NOAA-CREST GPR Study Eric Harmsen, Associate Researcher Agricultural and Biosystems Engineering.
Paul Kendall Alex Perez.  Virtually all of a cars linear energy is transferred to the brakes as thermal energy.  The faster the car stops, the less.
Integrated Drilling and Logging Program Approach in HPHT Environment: Successful Drilling of Deepwater Oberan Field, Nigeria, ENI Deepest Well in Deep.
Selection of measuring instruments
Engineering H191 - Drafting / CAD The Ohio State University Gateway Engineering Education Coalition Lab 4P. 1Autumn Quarter Transport Phenomena Lab 4.
Scoping Study of He-cooled Porous Media for ARIES-CS Divertor Presented by John Pulsifer Major contributor: René Raffray University of California, San.
04 October 2004New and Classical Uses of Heat Flow Studies, Aachen1 Geothermal Resource Mapping of Northern Switzerland Thomas Kohl, Nathalie Andenmatten-Bertoud,
P M V Subbarao Professor Mechanical Engineering Department I I T Delhi
Results The following results are for a specific DUT device called Single Ring Micro Resonator: Figure 6 – PDL against Wavelength Plot Figure 7 – T max.
Rock Coring Obtain undisturbed samples of solid, fractured, or weathered rock formations.
ChannelMaster Horizontal ADCP
Evaluation of a bedrock aquitard for regional- and local-scale groundwater flow Kenneth R. Bradbury, Madeline B. Gotkowitz, and David J. Hart Wisconsin.
8. Permeability (Das, chapter 7)
Exergy Analysis of STHE P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Formalization of Thermo-economics…..
CEMTREX, INC. MODCON SYSTEMS LTD NIR Systems July 2010.
Presented by Emil Melamed
Profiling Transmissivity and Contamination in Fractures Intersecting Boreholes USEPA-USGS Fractured Rock Workshop EPA Region 2 14 January 2014 Claire Tiedeman.
PHAT-TACO Experiment Pressure Humidity And Temperature Tests And Camera Observations Hannah Gardiner, Bill Freeman, Randy Dupuis, Corey Myers, Andrea Spring.
ENGINE Leiden Combining Areal Underground and Infrastructure Data to Minimize Exploration and Economic Risks Thomas Kohl, GEOWATT AG Clément Baujard,
EXPERIENCE IN INTRODUCTION OF ELECTRICAL LOGGING THROUGH METALLIC BORING CASING.
Group 17 Oceanic Thermal Energy Conversion Model - Lockheed Martin 1 Oceanic Thermal Energy Conversions Group Members: Brooks Collins Kirby Little Chris.
1 Modelling Task 8 EBS Task Force Meeting 16, Lund, 28 November 2012 Dr. David Holton Dr. Steven Baxter
Zbigniew Rymarczyk, Paweł Purgał – The Institute of Heating and Sanitary Technology in Radom Mieczysław Dzierzgowski – The Warsaw University of Technology.
Moisture impact on building rocks - the laboratory and in situ investigations FIDRÍKOVÁ D., KUBIČÁR Ľ. Institute of Physics SAS, Bratislava, Slovakia The.
Presented by: 1. A measure of how easily a fluid (e.g., water) can pass through a porous medium (e.g., soils) 2 Loose soil - easy to flow - high permeability.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
Salinometer Thermosalinograph (TSG) CTD
Seminar ON SMART SENSOR Submitted by : SUBIR KUMAR GHOSH Roll No. IN-14/04 Electrical & Instrumentation Deptt. B.E 7th Semester JORHAT ENGINEERING COLLEGE,
1:1 scale wellbore experiment for a better understanding of well integrity in the context of CO 2 geological storage, Mont Terri underground rock laboratory.
Estimation of Groundwater Recharge in a Stony Soil Based on Monitoring of Soil Hydraulic Data Emerstorfer N., A. Klik and G. Kammerer Institute of Hydraulics.
MUD LOGGING DEFINITION, THEORY & LAG CALCULATIONS
Applied Geothermics Aachen 0ct Numerical Simulation of a Thermal Response Test (TRT) Experiment R. Wagner Applied Geophysics, Aachen University.
Alex Gee Jon Locke Joe Cooper Kylie Rhoades Clara Echavarria Ice Energy Extraction.
Silesian University of Technology in Gliwice Inverse approach for identification of the shrinkage gap thermal resistance in continuous casting of metals.
Midterm results Average mark 73.7% (29.5 / 40) Median mark 30 / 40.
.. Smart sensors are sensors with integrated electronics that perform the following functions:  Logic functions  Two-way communication  Make decisions.
Manual Density Business Today
CHAPTER 5: Data sampling design, data quality, calibration, presentation Sampling Physical variables are continuous, but samples (water samples) and digital.
Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.
Today’s Lecture  Water levels and groundwater flow.
CE 3354 Engineering Hydrology Lecture 21: Groundwater Hydrology Concepts – Part 1 1.
Regularised Inversion and Model Predictive Uncertainty Analysis.
Sediment below ice Temperaturesensors q = -k dT/dz k = thermal conductivity dT/dz = thermal gradient Temperature Time each sensor... Heat flow, q (mW/m.
Advanced control strategies. CONTROL SYSTEMS The process parameters which are measured using probes described in the previous sections may be controlled.
Soil Stress and Pore Water Pressure
 Heat travels from hot to cold  The bigger the temperature difference the faster the rate of transfer.
Groundwater movement Objective To be able to calculate the hydraulic conductivity of a sample given measurements from a permeameter To be able to evaluate.
SOIL MECHANICS AND FOUNDATION ENGINEERING-II (CE 311)
SOIL MECHANICS AND FOUNDATION ENGINEERING-II (CE 311)
Data logging: The term 'data logging' refers to collecting or gathering data over a period of time. How Data is collected? Sensors are used to take readings.
BioTector Diagnostic Download
LISTEN TO YOUR RESERVOIR!
Comparison of the thermal characteristics and temperature profile of the ground in Cyprus with other Mediterranean countries This work is supported by.
How SCADA Systems Work?.
on Petroleum and Refinery
Module – Groundwater Level Measurement
For a barotropic flow, we have is geostrophic current.
Recirculating CO2 System
NEW ARISTON STORAGE BOILERS March, 2009.
Series 5300 Lithium Cell Formation System
P M V Subbarao Professor Mechanical Engineering Department I I T Delhi
EoCoE – Results of the geothermal energy part
Presentation transcript:

Purpose Probe construction Field and laboratory measurements Data processing, applicational example Conclusions, outlook A NEW METHOD TO DETERMINE in situ GROUND THERMAL CONDUCTIVITY IN BOREHOLE HEAT EXCHANGERS Ernst Rohner 1), Ladislaus Rybach 1,2), Ulrich Schärli 3), Thomas Kohl 1) 1) GEOWATT AG Zürich, 2) Inst. für Geophysik ETH Zürich, 3) Dr. U. Schärli – Geologie + Geophysik, Zürich

Goal and purpose Ground thermal conductivity is a decisive property for dimensioning of borehole heat exchangers (BHE): the specific heat extraction rate (W per m BHE length) is directly proportional to. Important for the design of BHE groups: optimization I.e. determining BHE number and depth must be done immediately after the availability of information. Although can be determined on rock samples from the borehole in the laboratory or in situ by a customary “Response Test” (a BHE circulation experiment), both methods need special equipment and are time-consuming. Therefore we developed a quick and simple method.

Rock thermal conductivity and its effect on BHE performance

Wireless Probe We developed and built a small, light, and wireless probe with pressure and temperature sensors. The probe contains also a programmable microprocessor in a closed metal case, water- tight up to 100 bar. The wireless probe is lowered into one tube of the U-shaped BHE where it sinks under its adjustable weight (=velocity) and records pressure (=depth) and temperature while going down, at pre-selected time (=depth) intervals. After the probe has reached the U-tube bottom it stops there and is flushed back to the surface by a small pump for recovery and data retrieval. A measurement run in a 300m deep BHE takes less than 60 minutes.

Wireless Probe (“Fish”) Electronics: P and T -Sensors Probe case 235 x 23 mm weight 99.8 g

Wireless Probe (“Fish”) Block diagram of probe

Wireless Probe (“Fish”) The built-in electronics (ADC with 16bit resolution) consists of Analog/Digital Converter, microprocessor EEPROMs (=electric erasable/ programmable read- only memory) for data storage. The software consists of three parts to perform the following tasks: controlling the probe operation communication probe  laptop (for data retrieval) calibration.

Wireless Probe (“Fish”) The controlling part runs in a programmable microprocessor (Basic Stamp BS2pe), performs the measurements and stores the data (time, pressure, temperature). The communications part consists of a macro in an Excel Workbook, reads the data into an Excel table and enables the configuration of the wireless probe, to set the measurement mode as well as the setting of time, pressure and temperature intervals. Data deletion, synchronization of probe, and laptop timing are also accomplished. Also the calibration part consists of a macro in an Excel Workbook; it enables to calibrate individual probes. The calibration parameters are stored in the probe. Thus the measurements can immediately be started, after configuration, with any of the probes built.

Function checks, after testing for water-tightness, have been performed under laboratory conditions. The temperature calibration in a thermostat vessel, the pressure calibration by hydraulic means. The probe has high temperature resolution (± C) and can store three times 16’000 measurements (time, pressure, temperature). The time constant of temperature measurement is 3.5 sec. Depth resolution is, due to the time constant, about ± 0.5 m. The calibration functions for pressure and temperature are described by second grade polynoms of the form y= a + bx + cx2. The calibrations constants a, b and c of each individual probe are stored in the probes. Laboratory tests und calibration

Temperature calibration (range: 0 – 50 °C)

Field operation with probe catcher and pump

Field measurement reults: Drillhole profile Temperature log Gradient logs (Raw data with  z=1.1m, smoothed with  z=13m) BHE drillhole in Bülach near Zurich, Switzerland

Field measurements

Calculation of the thermal conductivity profile Assumption: pure conduction (disturbing effects like palaeclimate, groundwater flow to be corrected for beforehand) From the temperature log T(z) the gradient log  T(z) is calculated depth sectionwise (i); Finally the thermal conductivity profile, with the local heat flow q loc from

Calculated thermal conductivity profile (full line), Laboratory measurements (vertical bars) BHE drillhole in Bülach/CH m

Petrophysical data, samples from BHE drillhole in Bülach/CH m : Thermal conductivity of rock matrix,  m : Matrix density,  eff : effective porosity, f : Thermal conductivity of water-saturated sample, ±  : measurement error

CONCLUSIONS Since probe manufacturing in 2003, several BHE boreholes have been logged in Switzerland. The results are fully satisfactory; the method is now routinely used to design large BHE arrays; The data processing yields the detailed distribution over the borehole profile; The wireless measurement offers several advantages: higher resolution, better signal/noise ratio than with logging cables; The measurement time for a 300m deep BHE is less than 60 minutes, whereas a Response Test takes at least 50 hours and requires large-scale equipment; The time saving is highly relevant under construction site conditions.

OUTLOOK The probe can be used, besides for thermal conductivity determination: Lithologic subdivision of borehole profiles, Data acquisition for palaeoclimatic studies, Identification of groundwater flow.