CALICE 03/14/05Ed Norbeck U. of Iowa1 PPACs in a Calorimeter Edwin Norbeck University of Iowa.

Slides:



Advertisements
Similar presentations
General Characteristics of Gas Detectors
Advertisements

ATLAS Tile Calorimeter Performance Henric Wilkens (CERN), on behalf of the ATLAS collaboration.
Radiation Detectors / Particle Detectors
Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
Particle interactions and detectors
1 Sep. 19, 2006Changguo Lu, Princeton University Induced signal in RPC, Configuration of the double gap RPC and Grouping of the strips Changguo Lu Princeton.
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
IHEP,Protvino,Russia 1 Current status of a gas luminosity monitor Sergei Erin † † For the LCAL group V.Bezzubov,S.Erin, A.Ferapontov, Yu.Gilitsky,V.Korablev,
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Prototype TPC Tests C. Lu 12/9/98 V = 0. Gas gain test for the low pressure chamber The chamber is constructed with the following parameters: D anode.
Directional Detectors and Digital Calorimeters Ed Norbeck and Yasar Onel University of Iowa For the 25 th Winter Workshop on Nuclear Dynamics Big Sky,
Visualizing Data from the LHC with the Atlantis Event Display Program Joshua Auriemma Advisor: Andy Haas.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
Slide 1 Diamonds in Flash Steve Schnetzer Rd42 Collaboration Meeting May 14.
Detectors. Measuring Ions  A beam of charged particles will ionize gas. Particle energy E Chamber area A  An applied field will cause ions and electrons.
High Energy Detection. High Energy Spectrum High energy EM radiation:  (nm)E (eV) Soft x-rays X-rays K Soft gamma rays M Hard gamma.
Main detector types Scintillation Detector Spectrum.
Far forward angle physics at the LHC E. Norbeck and Y. Onel University of Iowa For the 24th Winter Workshop on Nuclear Dynamics South Padre Island
Detectors The energy loss of particles in matter can be used detect and identify those particles. There are different types of “detectors”: - Gas-filled.
Lecture 11  Production of Positron Emitters, Continued  The Positron Tomograph.
E. Norbeck U. IowaFast Gas Detector APR 05 Tampa1 Small Fast Gas Detector for High-Energy Electrons E. Norbeck, J.E. Olson, and Y. Onel University of Iowa.
Slide # 1 Examples of pressure sensor packaging Temperature characteristics of a piezoresistive pressure sensor. Transfer function at three different temperatures.
Neutron Generation and Detection Lee Robertson Instrument & Source Division Oak Ridge National Laboratory 17 th National School on Neutron and X-ray Scattering.
Rad Hard Active Media for Calorimeters E. Norbeck, J.E. Olson, A. Moeller, and Y. Onel University of Iowa PPAC Čerenkov Liquid with Tungsten metal.
Energy Resolution of a Parallel- Plate-Avalanche-Chamber Kausteya Roy Professors E. Norbeck and Y. Onel.
1 Semiconductor Detectors  It may be that when this class is taught 10 years on, we may only study semiconductor detectors  In general, silicon provides.
Design of the Photon Collimators for the ILC Positron Helical Undulator Adriana Bungau The University of Manchester Positron Source Meeting, July 2008.
NEW COMMENTS TO ILC BEAM ENERGY MEASUREMENTS BASED ON SYNCHROTRON RADIATION FROM MAGNETIC SPECTROMETER E.Syresin, B. Zalikhanov-DLNP, JINR R. Makarov-MSU.
Scanning Electron Microscope (SEM)
Glass Resistive Plate Chambers
Study of UV absorption and photoelectron emission in RPC (Resistive Plate Counters) detector with an UV source Carlo Gustavino (INFN-LNGS) RPC and their.
Ionization Detectors Basic operation
Lecture 10  Relationship Between Wavelength, Frequency, Energy, and Velocity of Light  Production of Positron Emitters  Image of the Week.
Takeshi Fujiwara, Hiroyuki Takahashi, Kaoru Fujita, Naoko Iyomoto Department of Nuclear Engineering and Management, The University of Tokyo, JAPAN Study.
1 Methods of Experimental Particle Physics Alexei Safonov Lecture #15.
Development of Digital Hadron Calorimeter Using GEM Shahnoor Habib For HEP Group, UT Arlington Oct. 12, 2002 TSAPS Fall ’02, UT Brownsville Simulation.
Ion signals with R134a and R134 in a parallel plate proportional counter Edwin Norbeck, J. E. Olson, Y. Onel University of Iowa For Sec. DH-3 of DNP06.
Gain stability and the LYSO beam radiation monitor measurements
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
December 10, The Parallel Plate Chamber CERN Presentation Wout Kremers Detector R&D NIKHEF.
Xe-based detectors: recent work at Coimbra C.A.N.Conde, A.D. Stauffer, T.H.V.T.Dias, F.P.Santos, F.I.G.M.Borges, L.M.N.Távora, R.M.C. da Silva, J.Barata,
Ion signals with R134a and R134 in a parallel plate proportional counter Y. Onel, E. Norbeck, J. E. Olson University of Iowa For HCAL meeting at Fermilab.
PPAC in ZDC for Trigger and Luminosity Edwin Norbeck University of Iowa Luminosity Workshop November 5, 2004.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
Lecture 12  Last Week Summary  Sources of Image Degradation  Quality Control  The Sinogram  Introduction to Image Processing.
Matter Jeopardy Definitions Atomic Parts States.
Gas detectors in a ZDC (at LHC) Edwin Norbeck and Yasar Onel University of Iowa For7 th CMS Heavy-Ion meeting at Delphi June 2003.
Development of a Single Ion Detector for Radiation Track Structure Studies F. Vasi, M. Casiraghi, R. Schulte, V. Bashkirov.
Small, fast, low-pressure gas detector E. Norbeck, J. E. Olson, and Y. Onel University of Iowa For DNP04 at Chicago October 2004.
W Prototype Simulations Linear Collider Physics & Detector Meeting December 15, 2009 Christian Grefe CERN, Bonn University.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Upgrade plans for the ATLAS Forward Calorimeter at the HL-LHC Rutherfoord, J: University of Arizona On behalf of the ATLAS Liquid Argon Calorimeter Group.
PPAC Jonathan Olson University of Iowa Thesis Defense 8 April 2005.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
E+/e- Backgrounds at BEPCII/BESIII JIN Dapeng Aug. 22, 2011.
PPAC Parallel Plate Avalanche Counter Edwin Norbeck University of Iowa For meeting at SLAC June 2, 2004.
PPAC Jonathan Olson University of Iowa HCAL November 11-13, 2004.
Part-II Wire type detectors 1. Single wire counters.
Ilhan TAPAN* and Fatma KOCAK
Simulation of the Time Response of a VPT
Ultra fast SF57 based SAC M. Raggi Sapienza Università di Roma
“Performance test of a lead glass
Chem. 133 – 2/9 Lecture.
Ionization detectors ∆
Experimental Particle Physics
Semiconductor Detectors
PHYS 3446 – Lecture #17 Wednesday ,April 4, 2012 Dr. Brandt
Presentation transcript:

CALICE 03/14/05Ed Norbeck U. of Iowa1 PPACs in a Calorimeter Edwin Norbeck University of Iowa

CALICE 03/14/05Ed Norbeck U. of Iowa2 What is a PPAC? Two flat, conducting plates with a little gas between them Simple, low cost device Can be radiation hard Unaffected by heat, light No electronics or photodetectors attached (Parallel Plate Avalanche Counter)

CALICE 03/14/05Ed Norbeck U. of Iowa3 One plate can be divided into pixels to provide position resolution. We have studied a small PPAC as a single pixel of a detector for electromagnetic showers. What we learned from these studies have broad application. Results from small PPAC Use of PPACs in calorimeters Outline of talk:

CALICE 03/14/05Ed Norbeck U. of Iowa4 Single Pixel PPAC For Test With High- Energy Electrons Gap 0.6 mm 950 V across gap Cathode 7X 0 = 29 mm of tantalum Area of anode is 1.0 cm 2 Guard ring to simulate neighboring pixels Gas is isobutane at 120 torr

CALICE 03/14/05Ed Norbeck U. of Iowa5 Detail of gap and guard ring

CALICE 03/14/05Ed Norbeck U. of Iowa6 Test at home with a 7 mCi 137 Cs source Get up to 20 mV signals directly into 50  coax

CALICE 03/14/05Ed Norbeck U. of Iowa7 Signal into coax with no amplifier Signal observed directly with fast scope

CALICE 03/14/05Ed Norbeck U. of Iowa8 We did not have high-energy electrons so we made them in situ from protons interacting near the front end of our tantalum cylinder. The showers had amplitudes as much as 40 mV

CALICE 03/14/05Ed Norbeck U. of Iowa9 Signal shape from shower -30 mV 1.62 ns FWHM

CALICE 03/14/05Ed Norbeck U. of Iowa10 The signal comes from moving charges. In an avalanche, most of the electrons and ions are formed near the anode. The electron signal is fast but with a total area small compared with the ion signal. The ion signal is flat while the ions are moving and stops when the ions are collected. In the next slide, when the ions are collected at the cathode they liberate electrons.

CALICE 03/14/05Ed Norbeck U. of Iowa11 20 torr ethane 550 V 0.6 mm gap

CALICE 03/14/05Ed Norbeck U. of Iowa12 PPAC gasses Alkanes [methane (CH 4 ), ethane (C 2 H 6 ), butane, etc.] good Perfluoro analogs (CF 4, C 2 F 6, etc.) even better We have used: CF 4 (AKA carbon tetrafluoride and Freon 14) C 3 F 8 (Perfluoropropane) C 4 F 8 (Perfluorocyclobutane)

CALICE 03/14/05Ed Norbeck U. of Iowa13 Advantages of Perfluoro gasses Not toxic Does not burn Resists aging Easily recycled (A small chemical cartridge can be inserted in the gas line that will remove all impurities from the gas) High density (more primary electrons) Contains no chlorine so is allowed in national laboratories

CALICE 03/14/05Ed Norbeck U. of Iowa14 CF 4 at one atmosphere Required 2500 V with plate spacing of 0.6 mm Less than 1.5 ns electron signal Ion collection time 960 ns PPAC design much simplified at one atm.

CALICE 03/14/05Ed Norbeck U. of Iowa15 Beam In Typical Calorimeter The green is solid metal (W). Detectors that sample the shower are shown in blue. Detector near front end is for EM shower

CALICE 03/14/05Ed Norbeck U. of Iowa16 For electromagnetic showers in a high Z material the final deposition of most of the energy is by low energy electrons. If the plates of a PPAC are made of the same high Z material, the PPAC will provide a faithful sample of the energy deposition in the absorber. This does not work for thicker detectors because the lower energy electrons stop in the surface of the detector. The sampling fraction in a PPAC is small. The fractional error from sampling fluctuations is proportional to E -½. Fluctuations are not a problem if the showers have a large enough energy.

CALICE 03/14/05Ed Norbeck U. of Iowa17 High-energy showers with double PPAC Test with EM showers using 80 ps bunches of 7 GeV positrons from the Advanced Photon Source, at Argonne National Laboratory Each bunch contained 3.6 x positrons The showers were made by the beam halo striking the beam pipe. The energy was a small fraction of the 2 x eV in the bunch This is still a very large energy! (Shower passes through both PPACs)

CALICE 03/14/05Ed Norbeck U. of Iowa18 Double PPAC for testing energy resolution

CALICE 03/14/05Ed Norbeck U. of Iowa19 Energy Resolution Data of PPAC Test at ANL Ratio E front to E back is constant to within ± 2%

CALICE 03/14/05Ed Norbeck U. of Iowa20 CONCLUSIONS PPACs for a calorimeter Can be made radiation hard. Can provide position information. Have good energy resolution for high energy showers. Have sub nanosecond time resolution. Can connect PPACs directly into 50  coax Can test with  source on side Can operate at atmospheric pressure with CF 4 gas

CALICE 03/14/05Ed Norbeck U. of Iowa21

CALICE 03/14/05Ed Norbeck U. of Iowa22 At isobutane pressures less than 30 torr afterpulses sometimes occur during the first 20 ns. This is a worst case example. Total charge from the afterpulses can be much larger than primary signal. 10 torr 500 V