Anatoly Ronzhin, 23 June, 2009 Anatoly Ronzhin, June 23, 2009 The main results of the TOF study at MT beams, May-June 2009 The team: Anatoly Ronzhin, Hans.

Slides:



Advertisements
Similar presentations
T958! Fermilab Test beam experiment to study fast timing counters for FP420 MOU between UTA, Alberta, Louvain, Fermilab (Brandt spokesman) Data taking.
Advertisements

T-979: SiPM Time Resolution with DRS4 Readout Anatoly Ronzhin, Fermilab, AEM March 12, 2012 Team: Mike Albrow, Sergey Los, Pasha Murat, Erik Ramberg, Fermilab.
Double Chooz: Outer Veto
Anatoly Ronzhin, March 25, 2014, Fermilab, RTS Anatoly Ronzhin, Fermilab March 25, 2014 Development of a new fast shower maximum (SM) detector based on.
QUARTZTOFMike Albrow CMS-FP420 April 28 th 2008 QUARTZTOF An isochronous & achromatic Cerenkov Counter Making Cerenkov light parallel  point focusing.
Fast shower maximum detector based on MCP-PMT Anatoly Ronzhin, Fermilab, AEM, March 10, 2014 Team: Sergey Los, Erik Ramberg, Fermilab Artur Apresyan, Si.
Argonne Laser Test Stand and Fermilab Test Beam Facility Karen Byrum 8 March, 2007 Status of Argonne Laser Teststand (Joint ANL – UC program) Some first.
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
Review of PID simulation & reconstruction in G4MICE Yordan Karadzhov Sofia university “St. Kliment Ohridski” Content : 1 TOF 2 Cerenkov.
MICE: The International Muon Ionization Cooling Experiment Diagnostic Systems Tracker Cherenkov Detector Time of Flight Counters Calorimeter Terry Hart.
How We Became Experimentalists Suzanne Levine Saba Zuberi Len Zheleznyak REU 2002.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
Timing Properties of T0 Detectors At PHOBOS Saba Zuberi, Erik Johnson, Nazim Khan, Frank Wolfs, Wojtek Skulski University of Rochester.
Development of Picosecond-Resolution Large-Area Time-of-Flight Systems C. Ertley 2, J. Anderson 1, K.Byrum 1, G.Drake 1, H.Frisch 2, J. Genat 2, H. Sanders.
The UC Simulation of Picosecond Detectors Pico-Sec Timing Hardware Workshop November 18, 2005 Timothy Credo.
1 M. Bonesini - CM 25 RAL 5/11/09 PID status report M. Bonesini Sezione INFN Milano Bicocca.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
TOF for ATLAS Forward Proton Upgrade AFP concept: adds new ATLAS sub-detectors at 220 and 420 m upstream and downstream of central detector to precisely.
New particle ID detector for Crystal Ball at MAMI-C Daniel Watts, University of Edinburgh John Annand 1, B. Briscoe 3, A. Clarkson 2, Evie Downie 1, D.
T979: Si-Pms in MTest Anatoly Ronzhin, Fermilab, AEM 12 April, 2010
May 31, 2008 SuperB PID sessionMarko Starič, Ljubljana Marko Starič J. Stefan Institute, Ljubljana Report on hardware tests and MC studies in Ljubljana.
1 Fast Timing via Cerenkov Radiation‏ Earle Wilson, Advisor: Hans Wenzel Fermilab CMS/ATLAS Fast Timing Simulation Meeting July 17,
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Feb 10, 2005 S. Kahn -- Pid Detectors in G4MicePage 1 Pid Detector Implementation in G4Mice Steve Kahn Brookhaven National Lab 10 Feb 2005.
Photodetection EDIT EDIT 2011 N. Dinu, T. Gys, C. Joram, S. Korpar, Y. Musienko, V. Puill, D. Renker 1 Micro Channel plate PMT (MCP-PMT) Similar to ordinary.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
1 ALICE T0 detector W.H.Trzaska (on behalf of T0 Group) LHCC Comprehensive Review, March 2003.
Analysis of Endstation A setup Josef Uher. Quartz bar Start counter.
“End station A setup” data analysis Josef Uher. Outline Introduction to setup and analysis Quartz bar start counter MA and MCP PMT in the prototype.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
TOP counter overview and issues K. Inami (Nagoya university) 2008/7/3-4 2 nd open meeting for proto-collaboration - Overview - Design - Performance - Prototype.
work for PID in Novosibirsk E.A.Kravchenko Budker INP, Novosibirsk.
Development of TOP counter for Super B factory K. Inami (Nagoya university) 2007/10/ th International Workshop on Ring Imaging Cherenkov Counters.
PID for super Belle (design consideration) K. Inami (Nagoya-u) - Barrel (TOP counter) - Possible configuration - Geometry - Endcap (Aerogel RICH) - Photo.
Mike AlbrowSept 14 th 2006Time-of-Flight with GASTOFs im Test Beam 1 Fast Timing Counters for FP420/CMS and Test Beam Particle ID Mike Albrow, September.
Timing properties of MCP-PMT K.Inami (Nagoya university, Japan) - Time resolution - Lifetime - Rate dependence Photon Detector Workshop at Kobe,
Fast Timing Mtg April 15 th 2009 Mike Albrow Fast Timing studies at Fermilab : Test beam plans notes from meeting April 15 th 2009 MTest May Wed 27 th.
July 4, 2008 SuperBelle Meeting, KEKPeter Križan, Ljubljana Peter Križan University of Ljubljana and J. Stefan Institute Burle MCP PMTs as photon detector.
QUARTIC STATUS Nov 19 th 2014 Mike Albrow, Fermilab Baseline Plan Detector : Optics, SiPMs, (Readout board, connectors – S. Los) Time schedule Testing.
Shashlyk FE-DAQ requirements Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA FE-DAQ workshop, Bodenmais April 2009.
E. GaruttiCALICE collaboration meeting, Prague CERN Test beam (part II) Erika Garutti, Fabrizio Salvatore.
T979 QUARTIC Timing detectors for HPS240 M.Albrow, A.Ronzhin, S.Malik, Sergey Los, A.Zatserklyanyi, E.Ramberg, Heejong Kim New physics channels for CMS.
Mike AlbrowAll Experimenters, June 8 th 2009T979: Tests of Precision Timing MTest 1 Tests of Fast Timing Detectors in the Meson Test Beam (T979)
FIT (Fast Interaction Trigger) detector development for ALICE experiment at LHC (CREN) Institute for Nuclear Research (INR RAS) National Research Nuclear.
CERN September 29, 20041W.H.Trzaska HIP Jyväskylä T0 – TDR 22 nd LHCC meeting; Open Session CERN, September 29, 2004 W.H.Trzaska (for T0 collaboration)
KEK Test Beam Phase I (May 2005) Makoto Yoshida Osaka Univ. MICE-FT Daresbury Aug 30th, 2005.
Beam Halo Monitor : Q-bars+SiPMMike Albrow, 26 Aug 2010 A Beam Halo Monitor for the LHC based on Quartz Cherenkov Counters Mike Albrow (Fermilab) Features:
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
1 Calorimeters LED control LHCb CALO meeting Anatoli Konoplyannikov /ITEP/ Status of the calorimeters LV power supply and ECS control Status of.
Aerogel Cherenkov Counters for the ALICE Detector G. Paić Instituto de Ciencias Nucleares UNAM For the ALICE VHMPID group.
Module-0 of AFP ToF Detector Libor Nozka on behalf of ATLAS Forward Proton Group Palacky University 1.
LHCf Detectors Sampling Calorimeter W 44 r.l, 1.6λ I Scintilator x 16 Layers Position Detector Scifi x 4 (Arm#1) Scilicon Tracker x 4(Arm#2) Detector size.
M. Bonesini - CM 22 RAL October 081 TOF0 status M. Bonesini Sezione INFN Milano Bicocca.
Quartic tests at Fermilab test beam June rd 2015 One “prototype” module made. #1 ? To CERN mid July for August test beam.
Aerogel RICH & TOP counter for super KEKB Y.Mazuka Nagoya University June 14-16, 2006 The 3 rd SuperB workshop at SLAC.
TORCH – a Cherenkov based Time-of- Flight Detector Euan N. Cowie on behalf of the TORCH collaboration E N Cowie - TORCH - TIPP June 2014.
Mike Albrow, FermilabHPS Comments, Manchester 20l0 Some random HPS comments Mike Albrow HPS is accepted in CMS as an R&D project : Physics case is accepted.
KM2A PMT testing platform FENG Cunfeng, LI Chaoju, SUN Yansheng Shandong University THE 2 nd WORKSHOP OF AIR SHOWER DETECTION AT HIGH ALTITUDES IHEP, Beijing,
SHIP calorimeters at test beam I. KorolkoFebruary 2016.
Reed Research Reactor reactor.reed.edu/pictures.html reactor.reed.edu/pictures.html 1 Moriah Tobin Modeling Quartz Cherenkov Detectors.
Mike AlbrowHPS – Nov 25thQUARTICs : Tests and Plans 1 May-June Fermilab beam tests The next QUARTICs Test plans … unfortunately delayed SiPMs …. Wavelet.
Beam detectors in Au+Au run and future developments - Results of Aug 2012 Au+Au test – radiation damage - scCVD diamond detector with strip metalization.
FARICH status E.A.Kravchenko Budker INP, Novosibirsk, Russia.
Fabio, Francesco, Francesco and Nicola INFN and University Bari
PSD Front-End-Electronics A.Ivashkin, V.Marin (INR, Moscow)
The Beam Test at Fermilab:
ScECAL+AHCAL+TCMT Combined Beam FNAL
Latest Results from T979: PSec Time-of-flight
Variable distance from beam.
Performance test of a RICH with time-of-flight information
Presentation transcript:

Anatoly Ronzhin, 23 June, 2009 Anatoly Ronzhin, June 23, 2009 The main results of the TOF study at MT beams, May-June 2009 The team: Anatoly Ronzhin, Hans Wenzel, Erik Ramberg, Mike Albrow, Sasha Pronko, Fermilab Andriy Zatserklyaniy, University of Puerto Rico Andriy, Sasha and Hans are the new member of our picosecond test beam community (“picoclub”).

Anatoly Ronzhin, 23 June, 2009 SiDet preparation before the test beam Most of the “pico” test beam equipment: dark boxes with Faraday cages, trigger and veto counters, MPPCs assembly, MCP PMT micrometric supports, tubes supports, alignment were prepared and tested at SiDet. Main timing parameters of all photodetectors (SiPms, MCP PMTs Photonis, 240, 210 Photek, response vs HV) obtained with PiLas laser. Good consistency with test beam data. During the tb used as perfect reference. Power supplies (HV, LV), SMA: splitters, attenuators, cables were tested before test beam. Frontend, including Ortec 9327, VT120 preamps, S. Los amplifiers, TACs. DAQ was prepared, tested (including AD114 readout). This allowed to complete our program in timely fashion. Plan of strategy for the test beam was carefully prepared

Anatoly Ronzhin, 23 June, 2009 Frontend, readout prep at SiDet Extensive study of VT120, 9327, SMA: att., cables, splitters, (including cable length influence on the time resolution) before the TB. E.g., it was found that 14 meters of cables length of the 9327 NIM out does not worsen “electrical” time resolution, still the same (about 1ch=3.1ps). This allowed to locate NIM and CAMAC crates in the TB control room w/o resolution deterioration. Extensive study of TAC 566 plus AD 114. Influence of SiPms clipping on the time resolution.

Anatoly Ronzhin, 23 June, 2009 World’s Best Beamline Time-of-Flight System? MT TOF. Base distance (B) between start and stop counters 8.7meters, time resolution 24 picoseconds (sigma) for positrons. Proton peak position given by arrow. Stop - Photek 240, normal to window particle’s incidence, window thickness – 9 mm of fused silica. Start – two quartz bars at Cherenkov angle, each viewed by Photek 210 MCP PMTs. The obtained time resolution could be improved with use, e.g., Photonics MCP PMT as start counter (our previous test beam data). Proton peak position marked by arrow Beam time resolution 24ps

Anatoly Ronzhin, 23 June, 2009 For memory Note: TOF based on Cherenkov radiators has momentum threshold Photek 240 “downstream” MT TOF counter perfectly fits to “normal” particles incidence with packaging “Upstream” TOF counter should be as “thin as possible”. Inverse “square root” dependence of the time resolution vs number photoelectrons is true for fixed light pulse shape. Not necessarily true for Cherenkov TOF application. The number of photoelectron increased partially due to increase of a pulse duration in the case. H.Wenzel, E.Wilson Hans Wenzel plot

Anatoly Ronzhin, 23 June, 2009 Photek 240, from specs. 9 mm thickness, 40 mm diameter fused silica input window. Tb - 7 phes/1 mm. 10/12 um pore TTS – 100 ps, HV? Cost reduction?

Anatoly Ronzhin, 23 June, 2009 Photek 240, currently “best”. 5-7 ps - “time jitter with photoelectrons” obtained for the 240 on the beam. The level is require to explore exact deposit of “electrical time resolution”, “frontend jitter” into the value. Andriy is working on convolution of the Vavilov- Cherenkov light, 240 QE, quartz transparency to explain 7phes/1mm of “fused silica” 240 window. Next SiDet plan: timing uniformity along PC, SPTR dependence on HV. With PiLas, Ortec. More study of electrical time resolution deposit.

Anatoly Ronzhin, 23 June, 2009 Photek 210 “response vs. HV”, 210, 240 signals on TB Ch1-trigger Ch2-Photek 210, 1, 9327 analog out Ch3-Photek 210, 2, 9327 analog out Ch4-Photek 240, 9327 analog out Ch1-trigger Ch2-trigger plus VETO Ch3-Photek 210 signal for PH analysis Ch4-Photek 240 signal for PH analysis SiDet setup for 240, 210 study TTS – 30 ps, HV?

Anatoly Ronzhin, 23 June, 2009 Some of the MPPCs results obtained at SiDet and MT, time resolution, sigma 35 ps, best? 35ps/MPPC Ch1-trigger Ch2-MPPC analog out Ch3-MPPC analog out Ch4-Photek analog out MPPC’s SPTR dependences on overvoltage Time resolution vs 9327 input amplitude 35ps/MPPC, test beam data

Anatoly Ronzhin, 23 June, 2009 Also tested at TB Normal incidence, Photek 210Qbars, viewed by Photek 210 Qbar, viewed by 2 Photek 210 Aerogel Cher. counter

Anatoly Ronzhin, 23 June, x48 mm2 total sensitive area, 6x6 mm2 of the one channel size. Quartz radiator 50x50 mm2, 5 mm of thickness, covered the all MCP sensitive area, optical contact between the MCPs and quartz radiator, the MCP’s 2 mm thick input window. Sergey Los CB prototype of “active SUM” of the 64 channels. 2. Obtained about 30 ps per MCP. The time resolution is mostly due to larger capacitance, if to compare with the MCP “passive readout”. We got 14 ps time resolution for the same MCP with 2x2 chs “passive readout” on the Aug test beam. 3.Plans. In the beamline application the upstream TOF counter should be as “thin as possible” and downstream counter’s thickness not so important (ECAL, HCAL, muon, behind). In the current state it’s possible to use MCP PMT as “start counter”. S.Los continue to investigate “passive readout”. 64 chs, 8x8 MCP PMTs, Fermilab Test Beam Results

Anatoly Ronzhin, 23 June, 2009 Equations for sigma calculations Copy from beam elog. We had three detectors in beamline, I, II, III. Suppose the "intrinsic time resolution" of the detectors are I, II, III. (sigma of Gauss fit, for each of them). The measured values are T12, T13, T23 (sigma of Gauss for each of them, after all possible corrections). We neglect "electrical time resolution" of the readout, our SiDet and previous tb data shows up about 2-4 ps. We easy have 3 equations with 3 variables. I^2 + II^2 = T12^2 (1) I^2 + III^2 = T13^2 (2) II^2 + III^2 = T23^2 (3) unfolding, e.g. III from the 3 equations, we have III = sqrt (T13^2 + T23^2 - T12^2)/sqrt 2, I = sqrt (T12^2 + T13^2 - T23^2)/sqrt 2, II = sqrt (T12^2 + T23^2 - T13^2)/sqrt 2, Returned back to the setup with 2 Qbars and Photek 240. Both 1-3 and 2-3 combination gives us channels of the time resolution, same as yesterday. Tomorrow will move Photek 240 downstream, about 10 meters. Both Qbars, (1 and 2) will stay in the dark box in current position. We can improve our total time resolution by factor of 1.4 by measuring time of flight twice (1-3 and 2-3), so the final time resolution should be about 7-8 channels or ps (for positron only, for other particles will be dependent on the momentum spread). Sum 1-3 and 2-3 will “kill” time jitter due to the beam size. It should be good to arrange histo for 1-3 plus 2-3, event by event, devided by 2 for that. It would be also good to have in hands table with the time of flight difference for positrons, muons, pions and protons (for 4, 3, 2, 1 GeV of the momentum) and 1 meter of the base distance to be prepared for the tomorrow exercises. Histos and table done by Andriy and Sasha, thanks Anatoly

Anatoly Ronzhin, 23 June, 2009 Preliminary Summary 24 ps, sigma, obtained for MT TOF system 5-7 ps, sigma, Photek 240, for particles with “normal incidence”, (beta=1) 12 ps – Photek ps – double Qbars 35 ps, – for MCCPs 33.5 ps – for aerogel The analysis is not completed, continued

Anatoly Ronzhin, 23 June, 2009 TABLE with time resolution and number of photoelectrons of the tested photodetectors