Confidentiel –Usage interne Presentation RayCAm CA 1884.

Slides:



Advertisements
Similar presentations
Wireless H.264 Mage-Pixel PT Internet Camera
Advertisements

QUICK GUIDE MANUAL GV-DVR System Organization 2. Specification.
(PLEASE SWITCH TO THE SLIDE SHOW MODE)
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
TechnoTeam Workshop 2011: LMK mobile advanced LMK mobile advanced restrictions, instructions and tips.
TLA. Replacing The Battery On the Back of the pager press in this button while moving the door away from the pager, then lift up. On the Back of the pager.
MH 201, 203, 205 Classroom Technology University of Dayton Information Technology Classroom Support.
MDR-304 Digital Video Recorder. Can do: - Reliable real time recording of vehicle interiors & surrounding road environment. - Removable recorder unit.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
MODULAR SMPS POWER PLANT
SupaRule Cable height meters Presented by: Gary Carroll Director Feb 2004.
User Guide and Trouble-shooting Information. A classroom set of 20 cameras are available for teacher and student use. Capable of taking video, but recommend.
(Push to start camera) (Push to take picture) Shutter button Power switch.
Exposure & Settings: P Exposure & Settings.
Step 1: Using the Classroom Equipment The Crestron panel is the BRAIN of the classroom equipment. 1. Touch the screen to activate the controls 2. Press.
DIGITAL LIGHT METER Dr. Lim Jac Fang Occupational Health Doctor Department of Health, Sabah 1994 CT Lutron LX-105 LIGHT METER.
Market introduction CellaTemp PA.  Newest interface technology  Latest high-resolution microprocessors  Newest sensors  New amplifier technology 
Photo IT- How to capture, save and manipulate digital photographs.
Copyright © 2013 FingerTec Worldwide Sdn.Bhd. All rights reserved.
A solution to ATM Energy and Security Management
EPOCH 1000 File Management Data Logging and Reporting
1 QED In Vivo USB Input Output Box configuration This tutorial contains a number of instructions embedded in a great deal of explanation. Procedures that.
Digital Cameras Menu settings & Controls Instructor: David King.
1 Training Manual: KI7400 & 7800 Series Sources Level 1, V2.0 August 2008.
The DSLR Camera. Basic Parts Shutter Release Button/ On/Off Button Lens Zoom Adjustment Focus Adjustment Lens Release Button Mode Dial Flash Hot Shoe.
1. 2 LXU800 User’s Manual 1.Installation – Windows XP UI Features Introduction Data Connection & Disconnection.
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
Gates Professional Development Series Gates Sonic Tension Meter 507C NEW! Measures Tension in BothV-BeltsAnd Synchronous Belts.
EPOCH 1000 Series Software Update New Feature Overview - February 2011.
What’s in the Box? A look at items that come with your camera.
PC_F Physics Line - 1 Personnel et confidentiel Starting with infrared thermography.
ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 1
Cypress-Fairbanks I.S.D. 04/04/05 PC6 Word Processor Training Assistive Technology
NV V5.7 Product Presentation. Brand New Professional GUI  Multiple User Interface for different look and feel  Audio indicator on camera (play audio.
Vibration Data Collector 911D - Economic, Very-easy-to-use Features: Full automatic measurement Automatic diagnosis of machinery faults by time domain.
Camera Controls School of Innovation & Technology Mr. Kilmer.
The Mavica for the Maverick: A How-to Guide Operating instructions for the Sony Mavica CD350 Digital Camera An Easy-to-Follow Guide to Everything You Need.
Self Guided Tour of TagMate™QC Display Tag DATA Tag Data: PRINT TagMate™QC SETUP Display STATS Tags: START and READ SEND All Data to PC Additional Capabilities.
The Basics of Windows 7. Logging In Start Button.
Model 1621M Trainer’s Guide. General Overview Model 1621M is a Geiger Meuller based Personal Radiation Detector (PRD) Complies with ANSI Used for.
1.Overview 2. Hardware 3. Software Interface 4. Triggering 5. Installation 6. Configuring.
Ladibug Document Camera DC 170 BY ART LEBEAU SOURCED FROM THE MANUFACTURERS USER GUIDE.
C ANON EOS 5D M ARK II Jiahui Lu. General Information Can record sound and moving video as well as still photographs Displaying images on a screen immediately.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
Electronics-line.com PIR Camera. electronics-line.com ˗High sensitivity CMOS image sensor: Aptina MT9V136, ¼ inch ˗Various picture resolutions – VGA,
TECHNICAL TRAINING SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB.
1 Getting Started Exercise Part 1. 2 Profiles related to the exercise When starting use archive profile: GettingStarted_Start.zip The fully completed.
Digital Cameras What can they do?. Image Characteristics Resolution Compression Image Formats –JPEG –TIFF –RAW Possible Settings –ISO Sensitivity –White.
Mrs. Tegen Multimedia. Canon PowerShot A470 Get great pictures every time! Let the camera do the work so you don’t have to…
The Sony Mavica Digital Camera “The Computer as an Educational Tool: Productivity and Problem Solving” ©Richard C. Forcier and Don E. Descy.
Touch screen function manual Right & left scroll key Room selecting key, Maximal quantity 50. Controlling Target icon Room background image brightness.
Service Section Technical Training December 2005.
Programming 27x Optical 10x Digital Zoom Day/Night Camera Prosecutor Day / Night Windshield Mount Camera.
1 DVR SYSTEM User’s Manual Manual Revision : Version 1.0 Release Date : Nov. 2, 2002 ■ SERVER ■ CLIENT.
Introduction The Epson LCD projector is a highly versatile presentation tool. The projector can utilize up to two computer sources, and up to three video.
What you need: In order to use these programs you need a program that sends out OSC messages in TUIO format. There are a few options in programs that.
Run the on your PC to start the firmware configuration process Run IP Config Tool.
Parts of the Camera What Do They Do?.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
CI-202 Leaf Area Meter Instrument Training Conducted by: Brienne Meyer
Local Alarm Station Data Acquisition, Storage and Visualization for Radiation Portal Monitor (RPM).
HD-SDI COLOR IR LED CAMERA
Camera Parts.
Parts of the Camera What Do They Do?.
Classroom Digital Camera
Camera Parts.
20 camera parts of the Canon Rebel T3i
How To Use The FD92 Digital Camera
Presentation transcript:

Confidentiel –Usage interne Presentation RayCAm CA 1884

Confidentiel –Usage interne Structure RayCAm C.A 1884 Power supply interface USB interface. Standard USB interface connect to PC Video output interface. Standard RCA interface Main LCD Key panel Definable trigger Manual focus lens Cover of battery compartment

Confidentiel –Usage interne Structure RayCAm C.A 1884  Instructions on Key Operations  INSTRUCTION OF IMAGE DISPLAY STATUS BAR Power switch Power LED Control panel “A”: Auto Adjust key “C“: Cancel key / correction “S”: Freeze/live key, saving key 4 direction keys Menu - Enter «  »: user is in dynamic mode « ññ »: user is in freeze mode Operation condition : NULL, MENU, SP1, ISO or CAPT Emissivity of the target point Power status Sound alarm on or off The color bar in the middle represents pseudocolors

Confidentiel –Usage interne Items and Functions of the Menu  Sub menu « Analysis » Analysis► File Auto Adj. Manual Adj. Obj. Par. Image Only Setup Spot 1 Spot 2 Spot 3 Max Sp. Isotherm Remove all The camera will come into the temperature measurement condition. Move the camera or move the direction key to point the cursor to the target, the target’s temperature value will be displaying on the right-up of the screen Maximal or minimal temperature: one spot is tracking the highest or lowest temperature in the area.. The user can change the size of the area. The camera will do the isotherm analysis of the infrared image. If the temperature is in one setting area, it will be displayed in one color. Cancel all the analysis

Confidentiel –Usage interne Items and Functions of the Menu  Sub menu « File » Analysis File► Auto Adj. Manual Adj. Obj. Par. Image Only Setting Open Save Delete Open the images of the Flash Disk Save the image to the Flash Disk Delete the images of the Flash Disk

Confidentiel –Usage interne Items and Functions of the Menu  Sub menu «Manual Adj. » Level 30°C Span 10°C Temp. Range °C Filter Off it represents the median value of the temperature scale it represents the amplitude of the scale, i.e. the difference between the max. temperature and the min. temperature it represents the max. temperature range of the RayCAm

Confidentiel –Usage interne Items and Functions of the Menu  Sub menu « Obj. Par. » (Object Parameters) Emiss: 0.95 Distance: 5m Temp Amb: 25.0°C Humidity: 50% Material property. Setting between 0 to 1 Distance between the thermography user and the target * It seems the temperature around the target Parameter of the ambiant air * * You have to set these parameters only if you are > 10m of the target.

Confidentiel –Usage interne Items and Functions of the Menu  Sub menu « Auto. Adjustment »  the camera will do the auto-adjustment. The key “A” is the same function as this.  Sub menu « Image only »  the information will be concealed. You need to push on any key to make reappear all the information.

Confidentiel –Usage interne Items and Functions of the Menu  Sub menu « Setup » Analysis Capture spot : Maximum Alert: Activé Temp alert: 100°C Correct temp: 0° C Isotherm width : 0.7° C Isotherm color : Vert Isotherm alert : 50° C Laser Adjust : Activé Set the option “Max Sp” : auto-track the highest or the lowest T°C Turn on or turn off the temperature alarm function Preset the alarm temperature value Correct the value of the measured temperature Set the width of the isotherm range Set the color of the isotherm Sound alarm of the isotherm Define the position of image of the laser point and measure spot SP1

Confidentiel –Usage interne Items and Functions of the Menu  Sub menu « Setup » Local  Sub menu « Setup » Date and hour Language : French Video output : PAL Temp unit.: °C Dist unit : Meter Date format : DD/MM/YY Year: 2009 Month: 3 Day: 5 Hour: 7 Minute: 15

Confidentiel –Usage interne Show the current file / directory name Set the control switch of the trigger button Items and Functions of the Menu  Sub menu « Setup » Other Palette : Métal Auto Adjust : Lumin. et con. Continus Adj : Lumin. et con. Shut down : Jamais LCD display : Jamais Shutter period : Courtes File name : Directory name : Trigger Button: Laser on Palette : It provides a number of artificial color options Define the adjustment way of the key “A”. Set whether the camera needs to auto- adjust continuously according to the change of the image Set the camera that whether it needs to auto-shut down Set the screen that whether it needs to auto-shut down Set the period of auto-adjustment

Confidentiel –Usage interne Characteristics of the RayCAm C.A 1884  Detector characteristics  Size of the matrix: 120 x 160  Detection frequency: 50 Hz  Thermic sensibility: 0,1°C  Temperature range: -20°C to 250 / 600 / 1000 / 1500°C  Modelization thanks to the settings of all the parameters which affect the measurement  Emissivity, ambiant temperature, relative humidity, distance between the user and the target

Confidentiel –Usage interne RayCAm C.A 1884 characteristics  Optic characteristics  Field of view: 20° x 15°  IFOV: 2,2 mrad (A detector measure an object of 2,2 mm at a distance of 1m) HFOVVFOVPPOM 3*IFOV IFOV Distance minimale focalisation Imaging factor 0.1 m 0.3 m 0.5 m 1.0 m 2.0 m 6.0m10m30m100m 20°×15 ° 2.2 mrad10 cm HFOV (m) VFOV (m) IFOV (mm) PPOM

Confidentiel –Usage interne RayCAm C.A 1884 presentation  Analysis tools Automatic recognition T°C max … in a adjustable area 3 manual cursors: creation of an isotherm width And a sound alert to indicate a value have been overrun P01:46,1°C P02:41,5 °C P03:37,5 °C

Confidentiel –Usage interne Other specifications of the C.A 1884  Picture capacity  1000 radiometric pictures could be saved  Creation of 250 folders  Physical caracteristics :  Weight: < 700 g  Chocs resistivity: 25 G  Vibration resistivity: 2 G  IP 54  Environmentals requirements  Operating temperature : -20° to 50°C  Relative Humidity: 10 to 95 %HR  Storage temperature : -40°C to 70°C