Experiment 8. Thermodynamics of the Dissolution of Borax

Slides:



Advertisements
Similar presentations
The Care and Feeding of Burets
Advertisements

Determination of Calcium Carbonate in Eggshells
SURVEY OF CHEMISTRY LABORATORY I DETERMINATION OF THE DENSITY OF WATER
SURVEY OF CHEMISTRY LABORATORY I CHEM 1151L ANTACID EVALUATION.
Standardising potassium permanganate solution with iron(II) sulfate
Titration By Dr H W Winter.
1 Objective:The objective of this experiment is to determine the mass of acetylsalicylic acid (ASA) in an Aspirin tablet. Chemicals Potassium hydrogen.
Laboratory Techniques I: Dilution Go to browse and set to full screen.
Calcium Determination Using EDTA THEORY AND INTRODUCTION
SURVEY OF CHEMISTRY LABORATORY I
Experimental Procedure Lab 406. Overview A gas generator is constructed to collect the CO 2 (g) evolved from a reaction. The masses of the sample in the.
Analysis of Laundry Bleach: An Oxidation-Reduction Titration Tadas Rimkus AP Chemistry Period 2.
Titration Pre-lab.
Volumetric Analysis Apparatus. The Volumetric Flask.
Exp 4C: How Much Acetic Acid is in Vinegar?
Titrimetric procedure and Acid and Base Titrations Ch 20
Experimental Procedure Lab 402. Overview Three different experiments are complete in a calorimeter. Each experiment requires careful mass, volume, and.
Common Laboratory Glassware and Volumetric Glassware Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit.
Volumetric Analysis Apparatus. The Volumetric Flask.
CHM 101/102 Laboratory Manual Water Hardness: Determination with EDTA General Chemistry 101/102 Laboratory Manual University of North Carolina at Wilmington.
Laboratory Techniques II: Titration
Lab Techniques How to do a Manual Titration. Rinse the inside of the Burette Rinse the burette with 2-3 mLs of standarized NaOH solution. Make sure all.
How to do a Manual Titration. Rinse the Burette with 2-3 mL of standardized NaOH solution. Make sure all inside walls including the tip are rinsed. Discard.
Performing a titration A bluffers guide! Preparing a standard solution 4 Accurately weigh a weighing bottle, recording the mass 4 Add approximately x.
TITRATION This involves removing small samples from the reaction mixture at different times and then titrating the sample to determine the concentration.
Solutions Solubility -the amount of solute that can be dissolved to form a solution. Solvent – the substance in a solution present in the greatest amount.
Preparing Solutions LG: I can use formulas for concentration to prepare standard solutions from a solid.
Experimental Procedure. Overview The supernatant from a saturated calcium hydroxide solution is titrated with a standardized hydrochloric acid solution.
The thermodynamics of the solubility of borax Determination of ΔH° and ΔS°
Titration and Buffers Chemistry Department Minneapolis Community & Technical College Intro to Chemistry Chem1020 Lab 1.
Solutions & Solubility
Acid/Base Titration Thurston High School Chemistry.
Solutions.
Lab Techniques How to do a Manual Titration. Rinse the inside of the Burette Rinse the burette with 2-3 cm 3 of water then with 2-3 cm 3 the solution.
A buret is used to deliver solution in precisely-measured, variable volumes. Burets are used primarily for titration, to deliver one reactant until the.
Volumetric Analysis Topic 8.4 Titration readings in a normal titration you are usually advised to carry out at least one rough and two accurate.
Experimental Procedure Lab 406. Overview A known mass of starting material is used to synthesize the potassium alum. The synthesis requires the careful.
Section 8.4 – pg  Experimental designs discussed so far have been QUALitative (flame test, solution colour, litmus test, conductivity, solubility)
TITRATION Andy Park. What is Titration? A method of quantitative chemical analysis used to calculate concentration A known concentration and volume of.
Ksp by Titration Lab Sunday, November 01, General (you will be using a strong acid…use goggles!) You will create a new compound Ca(IO 3 ) 2 You.
After completing this topic you should be able to : State to accurately neutralise an acid using a solution containing an alkali or a carbonate requires.
Part-2 Standardization of Hydrochloric Acid Solution.
(Introduction ,The Equipment ,The Process , Calculations )
Experiment 5. A Rate Law and Activation Energy
Valdosta State University Experiment 5 NaOH Standardization Valdosta State University.
General chemistry Lab 2. Chemistry Analytical Chemistry Gravimetric Analysis Oxidation and Reduction Reactions Oxidation and Reduction Reactions Instrumental.
Introduction The Equipment The Terms The Process Calculations
1 Titrations (Review) In a titration a solution of accurately known concentration is added gradually added to another solution of unknown concentration.
Overview Several complexes of Cu 2+, Ni 2+, and Co 2+ are formed and studied. The observations of color change that result from the addition of a ligand.
Preparing Solutions.
Exp. 10 Vinegar Analysis: Acid-Base Titrations Purpose – To use quantitative analysis and titrations to find the concentration of an acid or base. In this.
Solutions & Solubility Solution Preparation. Solution Preparation from a solid  Standard Solution = a solution for which the precise concentration is.
Titration Analysis.
Introduction to Titration Go to browse and set to full screen.
Solution Chemistry Dilutions. Something to think about… What is a solution? Define polarity. What part of a water molecule has positive dipole moment?
Experiment: Solutions Preparation, Part 1 1CHE116.
General Laboratory Techniques Dry Lab Chemistry 1105.
枣庄学院化学化工与材料科学学院 Preparation of Solution. 枣庄学院化学化工与材料科学学院 1. Grasp the basic Method and Operation of Preparing Solution 2. Study the Method of Use about.
Trinity College Dublin, The University of Dublin Titration Demonstration.
Practical Analytical Chemistry (1) Practical (8) Faculty of Pharmacy Department of Pharmaceutical Chemistry.
Law ManWai(09) Lai MeiLing(28) Mo WanI(32)
How to do a Manual Titration
Lab Techniques How to do a Titration.
Introduction to Titration
Laboratory Techniques: Titration
How to do a Manual Titration
Common Laboratory Glassware
Acid/Base Titration Purpose- to find the concentration of four HCl samples, by titrating them with 0.100M NaOH Solution(titrant).
EXP. NO. 6 Acid Base Titration
Presentation transcript:

Experiment 8. Thermodynamics of the Dissolution of Borax Experimental Procedure Lab 406

Overview This experiment is to be complete in cooperation with other chemists/chemist groups in the laboratory. In PART A, a standardized solution of hydrochloric acid is to be prepared. In PART B, four warm water baths are to be set up at the beginning of the laboratory, each at a different temperature, but at a maximum 60oC. The water baths then are to be shared. In conjunction with four warm water baths for PART B, about 150 mL of warm (~55oC) deionized water is to be prepared for PART C.1. Begin those preparations.

Standardization of HCl Solution 1. Prepare the HCl solution. Prepare 0.20 M HCl solution in a 250 mL volumetric flask from 6 M HCl solution per experimental group)

2. Prepare the primary standard Calculate the mass of sodium carbonate that neutralizes 15 mL of 0.20M HCl at the stoichiometric point. Measure this mass on a tared piece of weighing paper or dish and transfer to a 125mL Erlenmeyer flask. Prepare at least three samples of sodium carbonate for the analysis of the HCl solution.

4. Titrate the primary standard 3. Prepare the buret Clean a buret and rinse with several 3-portions of the ~0.20M HCl solution. Use a clean funnel to fill the buret with the ~0.20M HCl solution and record the volume of HCl solution in the buret. 4. Titrate the primary standard To each solid sodium carbonate sample, add ~50 mL of deionized water and several drops of methyl orange indicator. Place a sheet of white paper beneath the Erlenmeyer flask.

5. Repeat the analysis and do the calculations Dispense the HCl solution from the buret, swirling the Erlenmeyer flask during the addition. Carefully add additional HCl titrant until the endpoint is reached and the color persists for 30 seconds. (a color change caused by the addition of one additional drop of the HCl solution from the buret) Stop the HCl titrant. After 10-15 seconds, record the volume of HCl in the buret. 5. Repeat the analysis and do the calculations Repeat two more analyses and calculate the molar concentration of the prepared HCl solution.

(tube number and your experimental group)]. B. Preparation of Borax Solutions [We will share water baths to keep a more accurate water temperature. Label the test tubes (tube number and your experimental group)].

Prepare stock solution of borax Calibrate test tubes Pipet 5 mL of deionized water into six clean medium-sized test tubes. Mark the bottom of the meniscus. Discard the water and allow the test tubes to air- or oven-dry. Label the test tubes (Test tube # and experimental group) . Prepare stock solution of borax Using a 250-mL Erlenmeyer flask, add 35 g of borax to 100 mL of deionized water. Stopper the flask and agitate the mixture for several minutes to prepare the saturated solution.

Prepare the test solutions of borax Label a second set of clean, medium-sized test tubes. Again, thoroughly agitate the borax stock solution and then half-fill this second set of medium- sized test tubes with the stock solution. Place the test tubes in the respective baths (Bath 1:≈56oC, Bath2: ≈48oC, Bath3: ≈40oC, Bath4: ≈32oC, Your beaker: Ambient, yellow box: ≈5oC). Prepare saturated solutions of borax a. Saturate the solutions. Occasionally agitate the test tubes in the baths to make solution in each tubes saturated. Solid borax should always be present and add more if necessary. b. Allow sample to settle (not change temperature). Allow the borax to settle until the solution is clear (this will require several minutes, be patient !) and has reached thermal equilibrium. Allow 10-15 minutes for thermal equilibrium to be established.

≈ 56 oC ≈ 48 oC ≈ 40 oC ≈ 32 oC Ambient ≈ 5 oC (Ice in the yellow box)

Prepare borax sample for analysis. Quickly but carefully transfer 5 mL of the clear solutions to the correspondingly labeled, calibrated test tubes from Part B.1. Do not transfer any of the solid borax.

C. Analysis of Borax Test Solutions Transfer the samples a. Prepare for sample transfer. Set up and label a set of six clean labeled 250-mL Erlenmeyer flasks. As the samples from Part B.5 cool to room temperature in the test tubes, some borax may crystallize. Return those samples to a warm water bath (~ 55 oC) until all of the solid dissolves. b. Transfer the samples. After the sample is clear in the test tube, transfer the solution to the correspondingly labeled Erlenmeyer flask, rinse the test tube with two or three ~5 mL portions of warm, deionized water (~ 55 oC) and combine the washings with the sample. “The warm distilled water (50 ~ 55 oC)will be prepared in the assigned water bath. Also share it.” (Caution! Borax is stable in aqueous solutions at temperatures less than 60 oC; at higher temperatures, some dehydration of the B4O5(OH)42- anion occurs)

2. Titrate the samples. Dilute each sample to about 25 mL with warm, deionized water. Add 2-3 drops of bromocresol green. Titrate each of the six samples to a yellow endpoint with the standardized HCl solution prepared in Part A. Remember to record the buret readings before and after each analysis of a sample.

D. Data Analysis(after experiment) Six repeated calculations are required to establish the data plot for the determination of ∆Ho and ∆So for the dissolution of borax. The lengthy task of completing the calculations and for minimizing errors in the calculations can be reduced with the use of an Excel spreadsheet. The data from the calculations can then be plotted using the embedded graphing capabilities of Excel. 1. Calculate the molar solubility of borax at each of the measured temperatures. 2. Calculate the solubility product of borax at each of the measured temperatures. 3. Plot the natural logarithm of the solubility product versus the reciprocal temperature 1/T(K-1) for each sample and draw the best straight line. 4. Determine the slope of the linear plot equal to -∆Ho/R and calculate the standard enthalpy of solution for borax. 5. Determine the y-intercept(at x=0) of the linear plot equal to ∆So/R and calculate the standard entropy of solution for borax.

Cleaning of the test tube and chemical disposal After completing the experiment, clean your test tubes in a hot stainless water bath to remove the remaining borax in the tube effectively. Dispose of the analyte and titrant in the waste container in the chemical hood.

Using of Buret Cleaning the Buret In order for your buret to perform optimally, it must be properly cleaned. To clean the buret, use the following procedure: 1. Rinse with distilled water: With the stopcock closed, add some distilled water to the buret. Tip and roll the buret, allowing the water to have contact with all of the inside surfaces. Open the stopcock and allow the water to drain. If the water drains without leaving any droplets on the side, repeat the rinse twice more then move to step two. If droplets remain on the inside surface, wash the buret with detergent solution, rinse several times with tap water, then rinse three times with distilled water. 2. Rinse with solution: After draining the final distilled water rinse, close the stopcock and add about 5 mL of the solution to be dispensed from the buret. Again, roll and tip the buret so the solution has contact with all the inside surfaces. Open the stopcock and allow the solution to drain. Repeat this twice more. Discard the solution used in the rinses. After you are finished with the buret in your experiment, rinse it by filling it with distilled water and allowing it to drain.

Loading the Buret Once the buret is clean, clamp it to a stand using a buret clamp. Always make sure the burette is clamped in a perfectly vertical position before taking any readings. When adding solutions to the buret, make sure the stopcock is closed (horizontal position). Unclamp the buret and tilt it slightly while pouring the solution slowly down the inside surface. This will prevent the formation of air bubbles. 1. Get the appropriate amount of solution in a clean, dry beaker. 2. Pour a few milliliters of solution into the buret. Open the stopcock all the way in order to force all the air out of the stopcock and tip. Close the stopcock before the solution drains below the stopcock. If the tip still contains air, add a few more milliliters of solution and repeat the process. Repeat this until you are convinced no more air is left in the stopcock or tip. Discard the solution that you have run through the buret.

3. Using the procedure described above for adding solutions to the buret, fill it to a level just above 0.00 mL. Drain the buret to just under 0.00 mL. This will properly form the meniscus. DO NOT ATTEMPT TO ADJUST THE MENISCUS TO EXACTLY 0.00 mL. THIS IS AN INCREDIBLE WASTE OF TIME. 4. Touch the tip of the buret to the inside wall of a beaker in order to remove any drops on the tip. Do not wipe the tip. Wait a few seconds for the solution to drain to the top of the fluid level, then record the initial buret reading in your notebook. 5. Loosely cover the top of the buret with a cocked, small beaker or a loosely fitting piece of aluminum foil. This will keep dust out of the buret.

Reading the Buret In order to make the meniscus easier to see, place a white card with a black mark on it behind the buret. Align the black mark so that it is just under the meniscus. 1. Get your eye level with the bottom of the meniscus. Looking up or down on the meniscus will cause a parallax error. 2. Read the buret to the nearest 0.01 mL. The marks occur every 0.1 mL, so the last number will have to be an estimate. With practice, you should be able to do this quite accurately.