Fire Fighting Systems Fi Fi Mains ●White System: This system has a lower output as far as volume goes. This main supplies 3x Eductor/Hydrants (500 gpm).

Slides:



Advertisements
Similar presentations
Fire Apparatus Pump Theory
Advertisements

Service Delivery 3 Pumps.
Dennis Fire Appliances Operations & use. PTO Step 1 Move slide cover towards the drivers seat to lock out the gearbox Step 2 Select drive on the gear.
Hydraulic Power Assist
Morgan City Rentals Diesel Jet Pump 6 x 6 Peerless Safe Operating Practices and Procedures.
FoamPro 1600 Series Fully automatic Class A foam ONLY
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
Hydraulic Valve, Pump, Motors
Simple Pressure Control Valves
CAFS On-Line Orientation
Tandem Pumping Video. INITIAL SIZE-UP When approaching the structure note the location of the FDC, Hydrant and Building Access.
DEWATERING PUMP.
FrontPower FRONT PTO 540 RPM or 1000 RPM
Fire Research Pump Boss 400 Pressure Governor
Proportioning Systems. 69 Proportioning Systems Now you know the benefits and uses of water additives, especially Class A foam. So how do we get the concentrate.
1B-1 Fire Engine Maintenance Unit 1B – Pump Inspections and Maintenance.
Power-Fill Operation Demonstration Power-Fill Operation Demonstration (See Installation and Operation Manual for detailed instructions)
AccuMax Single Point Injection Operation (See Installation and Operation Manual for detailed instructions)
CAFS On-Line Orientation
Dennis Sabre Fire Appliances
Bothell Fire and E.M.S. INTRO TO PUMP OPERATIONS Written and Produced by Jon Troglia Jon Troglia Bothell Fire and EMS.
Pump Installation Vigyan Ashram, Pabal.
C L A S #4 Driver Operator Refresher Training.
2001, 2002 & 3012 Series Operation 2001, 2002 & 3012 Series Operation (See Installation and Operation Manual for detailed instructions)
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Hydronic Mechanical Controls
Air Compressors.
Series Operational Training. 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner.
Circuits and Symbols. The flow of electrons through a circuit Electricity A closed circuit allows electricity to flow An open circuit has a break so electricity.
Water Handling Operations
Fire Pump Functions The main function of a fire pump is to increase the pressure of the water that flows through it. Inadequate or nonexistent municipal.
Dewatering Equipment.
Instructor Lee Lautzenheiser
Water Supply Skill Drills.
Automotive Heating and Air Conditioning CHAPTER Automotive Heating and Air Conditioning, 7e James D. Halderman | Tom Birch SEVENTH EDITION Copyright ©
Diesel Fuel - Fill Place all spill safety equipment where needed
D/C Power Systems General Locations. There are two types of D/C Power sources on the new fireboat: 24 Volt 12 Volt These are further subdivided into three.
Weekly Checks Monday – VSP Room Tuesday – Pilothouse System Controls Wednesday – Starboard / Engine Room Thursday – Foam Room Friday – Port / Engine Room.
Monday – VSP Room weekly checks Visually Check: Hvac system for leaks & valve settings Fresh water system for leaks & valve settings VSP linkage Autopilot.
Potable Water System General Locations and Operations.
BOAT Regulatory Gross Tonnage – 199 Registered Length – 96’7” Registered Breadth – 29’ Registered Depth - 13’3” Draft – 14’ 6” Air Draft – 46’
Red/Green Fire Fighting Systems Fi Fi Mains ●Red System: Port Side Fire Main supplies two Monitors. M7 (6000) gpm on centerline on the fwd Wheelhouse top.
PROSSER PUMP Long Beach Fire Department. BASIC SET- UP Components Main dewatering pump Junction box Attached power cord Additional extention cord.
Breathing Air Scott-RevolveAir Charge station with X4 controller. Storage Auto-fill capable. Unit can fill 2 SCBA bottles at a time behind a burst shield.
XAS 375 CD6 Compressors Committed to sustainable productivity
Fwd. Anchor Windlass / Capstan
Fire/General Service/Ballast Pumping Systems
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Bilge Pumping Systems General Locations.
Machinery Cooling Water System Locations and Operations.
Ships Service Air System
Coolant Fill Coolant Check and Fill. Oil Fill & Dip Stick Main Engine Oil Fill Dip Stick Delo 400 – 40 wt. Engine Oil.
OILGEAR PVV PUMPS PVV 200 Performance Curves.
Clean Lube Oil Transfer System General Locations and Operations.
FUEL SYSTEM The fuel system is comprised of three interconnected crash resistant fuel cells. Two forward fuel cells are located under the aft facing passenger.
KP Presentation KP1 and KP2 Features. KP Designations The Godiva KP series of rear or midship mounted PTO driven centrifugal fire pumps offers the ultimate.
STEP 1 Locate the transmission cooler line connection on the vehicle. Identify the correct adapters to be used by referring to the vehicle application.
ATP FOAM SYSTEM Engine 438 Ansul / Rockwood Model B2 400 GPM Around The Pump Foam System.
Automotive Heating And Air Conditioning
Dual Pumping Definition: An operation where a strong hydrant is used to supply two Engines by connecting the Engines intake-to-intake. The second Engine.
Fuel-Injection Systems
AIRCRAFT PNEUMATIC SYSTEMS
Auxiliary Engines Pumps Winches Steering engine Boilers Generators
Troubleshooting Hydraulic Pumps
Welcome to Malaga WeBex سیستم سوخت رسانی ریل مشترک کاتر پیلار
SB Packing Automatic Downpuller Power Unit
Booster Hose Reel Location/Operations.
Hydraulic Pressure Control
CAFS On-Line Orientation
FOAMPRO 2001 / 2002 Pump Panel. FOAMPRO 2001 / 2002 Pump Panel.
Presentation transcript:

Fire Fighting Systems Fi Fi Mains ●White System: This system has a lower output as far as volume goes. This main supplies 3x Eductor/Hydrants (500 gpm). All hydrants are located on the main deck. Two are at the aft Bulwarks, P&S and the other is just forward of the superstructure on port side. It also supplies the 1 inch hose reel located at the aft of the superstructure mounted overhead at the boat deck level. The White system is supplied by the # 3 Engine & # 7 Pump discharging 2000 psi. It is likely this system will be the most used on the boat.

Fire Fighting Systems Fi Fi Mains Overboard discharge Siphon Eductors Hose reel 2000 GPM Pump 7

Fire Fighting Systems A quick look at the controls on the panels in the wheelhouse. EZ to follow. The White system has its own control panel. The panel was not installed yet for us to show you.

Fire Fighting Systems Fire Pumps ●1-SFP HP 150x200 FFS single stage centrifugal pump ●Sealed bearings permanently greased no maintenance ●Hard mounted with a direct flexible coupling drive off the C-12 Caterpillar ●Nominal speed 1800 rpm ● psi ●Stand alone Pump and Engine. Can only be controlled from wheelhouse ●White System. Pump 7

Fire Fighting Systems Fi Fi Pumps Pump 7 Fi Fi Pumps

Fire Fighting Systems Fire Pumps Notice how much larger the clutched fire pump assemblies are in comparison to the direct drive units. Port Side RED system Stand alone C-12 White system Aft

Fire Fighting Systems Fire Pumps White system Pump is rated at 2000 gpm 250 psi. This will be the workhorse system. Most hand lines, (foam capable) dewatering of vessels and washdown/containment will derive from this system. Located aft and Starboard in the ER. Pump 7 Aft

Fire Fighting Systems Pump Intakes The White system (2000) gpm intake valve assembly is located just forward of # 7 Engine and Pump. Notice that the actuator sets right at the floor plate level. C-12 Engine

Fire Fighting Systems Discharge Piping The Discharge piping consists of a series of valves, check valves (clappers) and bypasses. Also system pressure sensors. As previously mentioned, the Blue System has an Isolation valve to separate the system into two parts if wanted. We are not going to trace all the systems out with a pictorial highway. To much to show. You will see it soon enough. But since these systems are all similar, a of couple of pictures will suffice. We will look at the bypasses, clappers and fire main overboard discharges. It is important to remember that there are NO relief valves in these Fire Fighting Systems. The occurrence of a Water Hammer has to be constantly on the mind of the operator while pumping. Thousands of gallons (weight) in motion can not stop quicky without damaging something! Take your time!

Fire Fighting Systems Discharge Piping Clapper Valve All discharge systems are identical in regards to the valving, clapper- valves and bypasses. Remember the discharge valves are remotely controlled from the wheelhouse FFS panels.

Fire Fighting Systems Bypass Systems ●Clapper Valve bypass (drain) ●Clapper Valve ●Isolation Valves ●Bypass Loop ●(RC) Discharge Valve ●Sensors/Gages The idea of the bypass loop is to be able to fill the system very slowly to minimize water hammer. In reality we will leave the isolation valve open and fill the system at idle, watching for a lazy discharge out the monitors. Possibly at times using the overboard discharges.

Fire Fighting Systems Fire Main Overboards The overboard systems are remotely controlled from the FFS panels. The operator can use the Overboards to divert pressure or drain a system. The water flow is directed downward at the through hull for obvious reasons. Visualize the out flow. Overboard Discharge Clapper Valve (RC) Discharge Valve

Fire Fighting Systems Observation/Security Drones They are camouflaged to look like Ospreys Camera

Fire Fighting Systems Fi Fi Controls The controls are 24v activated from the FFS panels. The discharge valves are Electric Motor driven. The intake valves are Electric/Air. Air being the driver. Valves are slow Opening/Closing

Fire Fighting System Fi Fi Controls Valve Open/Close switch (momentary) EZ to follow Engine Run Indicator Valve Open/Close Light Clutch In/Out Button and indicator light EZ to follow diagrams

Fire Fighting System Fi Fi Controls Pressure Gages are located on the fore and aft panels in the Wheel- House. Pick your color! Notice there are two Blue gages. This is because the Blue system can be separated by the Isolation valve we mentioned earlier.

Fire Fighter System Fi Fi Controls Overview of forward panel. EZ to follow! Notice they are installing the Engineer's chair! SWEET!

Fire Fighting System - White Fi Fi Overview Aft Hose Reel 300’x1” (Main Deck) Fwd Hydrant (2) 2 ½” Valves Aft Eductors (Port & Stbd) 500-GPM Fwd Eductor (Port) 500 GPM

Fire Fighting Systems Fi Fi Hydrants/Manifolds White system Hydrants and Educators x3 Starboard Aft Port Frwd Identical Port- side