The completed wheel design functions to produce resultant force as a function of voltage. Final Design Redesigned circuit to increase CMRR and amplify.

Slides:



Advertisements
Similar presentations
Instrumentation (AMME2700) 1 Instrumentation Dr. Xiaofeng Wu.
Advertisements

ANNUAL MEETING RERC on Technologies for Children with Orthopedic Disabilities NIDRR H133E Program Director: Gerald F. Harris, Ph.D., P.E. Program.
Working for the future - today
Adaptive Adjustable Wakeboarding System Lorielle Alter 1, Cory Gerken 2, Lauren Mitchell 3, Nick Pilkington 2, Katy Serowka 1 Advisors: Dr. Paul King 1,
myDAQ Biomedical Instrumentation Board
Data Acquisition Risanuri Hidayat.
RockSat-C 2012 CoDR Minnesota Sound Wreckers Conceptual Design Review University of Minnesota Alexander Richman Jacob Schultz Justine Topel Will Thorson.
Exhaust Emissions Analyzer Introduction In a day when global CO 2 levels are one of the greatest concerns of society, surprisingly few advances have been.
FORCE-STRAIN-STRESS measurements.
Instrumentation (AMME2700) 1 Instrumentation Dr. Xiaofeng Wu.
Codey Lozier Christian Thompson Advisor: Dr. Mohammad Saadeh
myDAQ Biomedical Instrumentation Board
Viking Pump Flow Manager - Phase 2 Senior Design May
Vanderbilt University School of Engineering Software-driven Pneumatic Beating Heart Simulator and ECG Display Jacob Bauer, Nicole Rice, Ashley Whiteside.
Biofeedback System for Propulsion Training February 22, 2007 Group Members: Noah Reding Nick Chadwick Tom Soike Project Sponsor: Dr. Mark Richter, MAX.
Interfacing Physics Sensors Using National Instruments Educational Laboratory Virtual Instrumentation Suite & LabVIEW by Eric Ethridge Left to right: motion.
An Opening in the Abdomen An Opening in the Market: Hernia Tensiometer GROUP 2: Martha Ingram Megan Johnston Chelsea Samson.
Speakers: Dale McGrath Keron Alexander Matthew Manning Nic Milton Aleksandar Adamovic Advisor: Patricia Mellodge.
Team Members Jordan Bennett Kyle Schultz Min Jae Lee Kevin Yeh.
Pain Stimulator Bryan Eckerle 1, Katharine McFadden 1, Adam Platt 1, Elizabeth Slyziuk 2, Jennifer Wells 1 Advisors: Paul King, Ph.D. 1 and Stephen Bruehl,
MSP430 Group Project ECE 300 Spring 2007 Dr. Walter Green Jeffrey Logsdon John Ly Daniel Henderson Nataly Sumarriva.
Muscle Volume Analysis 3D reconstruction allows for accurate volume calculation Provides methods for monitoring disease progression Measure muscle atrophy.
Instrumented Wheel For Wheelchair Propulsion Assessment. Jacob Connelly Andrew Cramer John Labiak.
In-Vivo Device for Measuring and Adjusting Lap-Band Pressure Mark Fritz 1, John Huidekoper 1, Andrew Koivuniemi 1, David Mayhew 1, Chris Schroeder 1 Robert.
Solar Powered Blood Pressure Assist Device Laura Allen 1, James Berry 2, Casey Duckwall 2, David Harris 1 Advisor: Dr. Franz Baudenbacher 2 Department.
Propulsiometer Instrumented Wheelchair Wheel Prepared by: Seri Mustaza (BME) Siti Nor Wahida Fauzi (BME) Ahmad Shahir Ismail (EECE) Hafizul Anwar Raduan.
PXL Cable Options LG 1HFT Hardware Meeting 02/11/2010.
Handheld Flow Calibrator for Aerosol Observing System Jonathan Ma, Dung (Yung) Hoang Nguyen, Mario Zuniga Department of Mechanical and Aerospace Engineering,
Programmable Biofeedback Chest Exerciser Eileen Bock, Lauren Cassell, Margaret Gipson, Laurie McAlexander Department of Biomedical Engineering, Vanderbilt.
Trey Herrington Electrical Engineer - Backup Power Supply - Backup Power Supply - PCB Design - PCB Design Samantha Prine Electrical Engineer -Enclosure.
Mobile EKG Sensor Senior Design May0530 ABSTRACT PROJECT REQUIREMENTS The goal of this project is to develop a method of collecting heart rates using Vernier’s.
Anti-tip bar leg attached to a collar fitted with side plates with guiding grooves designed to provide stopping points to the tip system Addition of copper.
V i t a l i s Wireless Biometric Sensor ECE 477 Final Presentation Team 13  Spring 2013 Paste a photo of team members with completed project here. Annotate.
Propulsiometer Instrumented Wheelchair Wheel Prepared by: Seri Mustaza (BME) Siti Nor Wahida Fauzi (BME) Ahmad Shahir Ismail (EECE) Hafizul Anwar Raduan.
Propulsiometer Instrumented Wheelchair Wheel Prepared by: Seri Mustaza (BME) Siti Nor Wahida Fauzi (BME) Ahmad Shahir Ismail (EECE) Hafizul Anwar Raduan.
.  Attached strain gauges to top and bottom of a new aluminum tab and connected them into a half Wheatstone bridge circuit.  Secured one end of the tab.
BME 353 – BIOMEDICAL MEASUREMENTS AND INSTRUMENTATION MEASUREMENT PRINCIPLES.
This article and any supplementary material should be cited as follows: Gagnon DH, Babineau A, Champagne A, Desroches G, Aissaoui R. Pushrim biomechanical.
Biomechanical Tissue Stimulator Group 1: Matt Brady (BME/EE) Ankeet Choxi (BME) Misha Kotov (CS) Steven Manuel (ME) Adviser: Dr. V. Prasad Shastri.
Biomedical Instruments Design 475 BMIS Circuit Design.
 Heat-treated torsional spring pins allowing for more vertical flexibility.  While highly adjustable, the current lever is a bit bulky for the aesthetically-concerned.
Group #15 Matt Frank Russell Geschrey.  This project was chosen because of an interest in wireless communication systems, namely BAN's (body area networks)
To develop a secure attachment for data logger and tri-axial accelerometer Replication of a tri-axial accelerometer with the ability to: -Interface with.
BY TEAM FARMERS 16 TH MAY :00-14:00 Product Demonstration.
AGROFARM WEATHER MONITOR USING LabVIEW. INTRODUCTION Innovation in agriculture field Implementing instrumentation tech. in agricultural field The quantity.
Quad Rat Vitals Monitor Robert Bjerregaard 1, Matthew Bollom 1, Caitlyn Collins 1, Derek Klavas 1 Advisor: Paul Thompson 1, PhD. Client: Alex Converse.
PCB Assembly. INTRODUCTION  PCB abbreviation is a printed circuit board,also known as a printed wiring board.  For electronics PCB is used to build.
Gas Pressure Meter (Engineering World Health) Advisor: Prof. Ken Gentry Client: Prof. John Webster, Engineering World Health Engineering World Health Team.
Printed by Biofeedback System for Propulsion Training Tom Soike (BME), Nicholson Chadwick (BME), Noah Reding (EE) Project Sponsors.
Instrumented Wheel For Wheelchair Propulsion Assessment. Jacob Connelly Andrew Cramer John Labiak.
Abstract Problem Definition Final Design: Progress and Results Conclusions Acknowledgments Instrumented Hand Exerciser to Promote Fistula Maturation Brian.
Instrumented Wheel For Wheelchair Propulsion Assessment. Jacob Connelly Andrew Cramer John Labiak.
Development of T3Maps adapter boards
Instrumented Walker Skyler Bullington Tommy Frankenberger Larson Stacy
Lactate Sensor Design: Smart Gels for Diabetes Pre-screening
Wheelchair Fatigue Reducer Schematic of Signal Communication
Microcontroller Enhancement Design Project
MECH 373 Instrumentation and Measurements
MECH 373 Instrumentation and Measurements
Instrumented Walker Status Update 2
For Wheelchair Propulsion Assessment.
Bicycle Power Meter I love the bike blender!!!! P16214 Sean.
FitSki Lorielle 11/30/2018.
FitSki Lorielle 11/30/2018.
FitSki Lorielle 1/1/2019.
FitSki Lorielle 1/14/2019.
FitSki Lorielle 2/18/2019.
Propulsiometer Instrumented Wheelchair Wheel
Wireless Electrocardiogram System Senior Project
Presentation transcript:

The completed wheel design functions to produce resultant force as a function of voltage. Final Design Redesigned circuit to increase CMRR and amplify the voltage output signal. Circuit Design Changed tab dimensions in order to increase sensitivity through increased flexibility. Tab Design Decreased the number of push-rim attachments from 6 to 3 in order to decrease rigidity of push-rim. Pushrim Attachments DescriptionPrototype 2Prototype 1Design Element. Manual wheelchair users (MWUs) are living longer and fuller lives due to innovative technological and medical advances. While the progress has been substantial, there are still areas of need in this population. More than half of MWUs experience upper extremity (UE) pain and injury 1,2,3. The UEs serve as the principle means for mobility, therefore, any impeding factor, such as pain or injury, can lead to a decreased quality of life. The development of UE pain and injury may be a result of improper propulsion biomechanics or poor wheelchair seating configurations. In order to quantitatively assess a MWU's propulsion technique for training or seating purposes, there is a need for an instrumented assessment tool. INTRODUCTION Instrumented Wheel for Wheelchair Propulsion Assessment Jacob Connelly, Andrew Cramer, John Labiak, Advisor Mark Richter, Ph.D. Vanderbilt University Department of Biomedical Engineering, Nashville, TN, USA Max Mobility LLC, Nashville, TN, USA GOALS & OBJECTIVES  Develop an instrumented wheelchair wheel utilizing strain gauges.  Quantitatively measure resultant force during wheelchair propulsion.  Minimize costs in order to provide an affordable tool for wheelchair seating clinics. o Production cost less than $2,000 o Market price $3,000 to $5,000  Integrate universal compatibility into the design of the instrumented wheel. o Capable of fitting all wheelchairs. o Adaptable to different size wheels (24'', 25'', and 26''). o Provide wireless capability with Bluetooth technology. Acknowledgments METHODS RESULTS AND DISCUSSION The prototype was tested to determine the sensitivity of the instrumented wheel. The output voltage was recorded in LabView for each individual tab, yielding high sensitivities for each tab as seen in Figure 2. Voltage responses were strongest when force was applied to the pushrim directly above the tab. The two other tabs, located 120° away, responded to a lesser degree and oppositely to the previous tab as expected. A standard resultant force curve was constructed from the output voltage data taken in LabView. The three tabs measure individual voltage outputs relating to applied force at that respective tab. These measurements require a systemic integration in order to produce an overall measurement of total resultant force applied to the pushrim. Paul King, Ph D. – Faculty Advisor, VUSE Department of Biomedical Engineering Russel Rodriguez M.E. – Project Engineer, Max Mobility LLC Adam Karpinsky M.E. – Project Engineer, Max Mobility LLC Guo Liyon M.E. – Project Engineer, Max Mobility LLC Franz Baudenbacher, Ph D.– Consultant, VUSE Department of Biomedical Engineering Tobias Meyer – Consultant, VUSE Department of Biomedical Engineering 1 Sie IH, Waters RL, Adkins RH, Gellman H. Upper extremity pain in the postrehabilitation spinal cord injured patient. Arch Phys Med Rehabil. 1992;73:44–48. 2 Dalyan M, Cardenas DD, Gerard B. Upper extremity pain after spinal cord injury. Spinal Cord. 1999;37:191–95. 3 Gellman H, Sie IH, Waters RL. Late complications of the weight-bearing upper extremity in the paraplegic patient. Clin Orthop. 1988;233:132–35. References T C OUTPUT VOLTAGE  Pushrim tab redesign: thickness (0.125’’  0.09’’) and width (0.50’’  0.40’’).  Tested strain gauge response in a Wheatstone bridge circuit on breadboard.  Designed the instrumentation amplifier based on the strain gauge response.  Removed the old tabs and welded the three new tabs onto the pushrim.  Designed printed circuit board.  Wired the wheel.  Attached the strain gauges to the tabs.  Soldered all components onto the printed circuit board.  Connected the strain gauges and power supply to printed circuit board.  Measured theoutput voltages from printed circuit board.  Must be between 0-5V.  Connected printed circuit board to the DAQ.  Developed LabView program to record, process, and display data.  Recorded voltage data via Bluetooth in LabView.  Recorded voltage data for each tab by applying known forces with a spring scale.  Mounted the printed circuit board, DAQ, and power supply to the spokes of the wheel.  Created a standard curve for the wheel. Figure 2. The output voltage for tabs 1 (red), 2 (white), and 3 (green). Figure 1. The initial prototype design changed significantly during the course of the project. RESULTANT FORCE CURVE Figure 3. Output voltage readings from each tab were used to construct the Standard Curve above. CONCLUSIONS FUTURE WORK The prototype wheel developed here demonstrates the ability to assess wheel chair propulsion by measuring strain created by resultant force. Small changes in voltage created by flexion in the pushrim can be sufficiently amplified in order to gain the appropriate sensitivity to clearly track the resultant force applied to the system. Improvements to the current prototype include the use of more precise circuit components, which can cause imbalances in the bridge circuit creating deviations in the output voltage of respective tabs. Also, to more accurately gauge resultant force over the entire pushrim, software or hardware (angle sensor) additions are necessary for determination of the applied force location. Inclusion of more pushrim tabs around the wheel to better track the applied propulsion forces is another option for future modification. Each tab is routed to its respective bridge and amplifier circuit.