1 IMMUNOCYTOMETRIC QUANTITATION OF RHD POSITIVE FETAL RBC IN BLOOD OF RHD NEGATIVE MOTHERS USING ABBOTT CELL DYN SAPPHIRE COMPARATIVE STUDY USING KLEIHAUER.

Slides:



Advertisements
Similar presentations
MATERNAL HEALTH Some technical aspects ANC, Delivery Care and PNC
Advertisements

DR. RAZAQ MASHA, FRCOG Consultant, Ob/Gyn Dept.
Rh ISOIMMUNIZATION Ghadeer Al-Shaikh, MD, FRCSC
USUHS MSIII Ob/Gyn Clerkship Self Directed Studies Isoimmunization Ch Academic Year MSIII Ob/Gyn Clerkship Self-Directed Study.
Hemolytic Disease of the Newborn Case #3
Transfusion Medicine, BCSH
District 1 ACOG Medical Student Education Module 2008
ALLOIMMUNIZATION IN PREGNANCY
Updates and Clarifications
8th Edition APGO Objectives for Medical Students
Rh/D y grupos débiles de D, de notas de internet Notas amables, sencillas, claras de apoyo en el estudio del tema.
Umbilical cord clamping in term deliveries: the RCOG perspective Dr Anna David Reader and Consultant in Obstetrics and Maternal Fetal Medicine UCL Institute.
Dr. Sanjay Curpad. S. What is it?  A condition that has an adverse effect on the foetal red cells in response to the maternal immunization.
London Regional Transfusion Committee Blood Grouping and Antibody Testing in Pregnancy Training Presentation by iTransfuse with the London RTC Based on.
Isoimmunization Erythroblastosis Fetalis Hemolytic Disease of the Newborn Zeev Weiner Director of Ultrasound in Obstetrics and Gynecology Lutheran Medical.
Dr. Afaf I. Alnoury RHESUS INCOMPATIBILITY بسم الله الرحمن الرحـيـم.
Fetal Haemolytic Disease. Maternal antibodies develop against fetal red blood cells IgG antibodies cross the placenta Haemolysis, anaemia, high-output.
MW / LS MT 417 – Clinical Hematology II Manual/Special Tests Unit Kleihauer-Betke Exercise KB Questions KEY.
BLOOD PHYSIOLOGY Practical 1
1 BLOOD PHYSIOLOGY Practical 1 BLOOD GROUPS By: khulood Hussein.
Blood Group Incompatibility in Pregnancy
Salwa Hindawi Rh-D Immunoglobulin Administration Salwa Hindawi Blood Transfusion Services KAUH.
Dr. Zahoor Lecture – 5 1 HMIM BLOCK 224. Different types of Blood groups blood group system Explain blood typing and how it is used to avoid adverse reactions.
H EMOLYTIC D ISEASE OF THE N EWBORN C ASE #3. S CENARIO Baby Girl Dae Two-day old jaundiced newborn girl Sample of her blood submitted for HDFN workup.
Blood Types Ch Blood Types Blood cells have surface markers called antigens ABO Blood Group – RBC with A antigens – A blood type – RBC with B antigens.
Immune Hematology L Bonstien PhD E J Dann MD. RED BLOOD CELL SURFACE MAMBRANE.
Hemolytic Disease of the Newborn (HDN) & COOMBS TEST
HAEMOLYTIC DISEASE OF THE NEW BORN (HDN)
CLS 2215 Principles of Immunohematology
Lab 4 Practical Blood Bank. Weak expression of the R h D antigen (D u ) The term D U is widely used to describe cells which have :  a quantitative reduction.
Unit 11 Neonatal and Obstetrical Transfusion Practice – Part 3
Rh Factor ISOIMMUNIZATION Associate Professor Iolanda Blidaru, MD, PhD.
Maternal Antibodies – Implications for the fetus/neonate
TEMPLATE DESIGN © Reduced Fetal Movements as a Predictor of Fetal Compromise Dr. Meenu Sharma Lancashire Teaching Hospital.
Practical Blood Bank Lab 4 Weak D testing (Du).
Rh – isoimmunization & ABO incompatibility
Dr: Dalia Galal Hamouda
Review of Blood type and Rh. Blood types and Blood groups  Blood Types- two parts the ABO part and the Rh part. A, B, O specify the types of proteins.
Hawler Medical University Clinical Analysis Department
The Role of a Transfusion Laboratory in Antenatal Care in the UK Mr M.W. Brown FIBMS North Bristol NHS Trust.
W EAK D T ESTING (D U ) Mr. Mohammed Jaber.. WEAK EXPRESSION OF THE R H D ANTIGEN (D U ) The term D U is widely used to describe cells which have a quantitative.
Rh NEGATIVE PREGNANCY. The individual having the antigen on the human red cells is called Rh positive and in whom it is not present is called Rh negative.
Practical Blood Bank Lab 3 Rh Grouping.
Chapter 05. Rh blood group system.
Dr. ARMAA A. AL SANJARY DEP.OBST.&GYN.
BLOOD TYPES ABO and Rh groups. Blood Type History Blood tests required before marriage (more to do with diseases than any other reason…)
Rh Blood Grouping. Rh Blood Grouping Rh antigens Rh antigens were originally discovered in the RBCs of Rhesus Monkey- Named as ‘Rh antigens’ or ‘Rh.
DR. RAZAQ MASHA, FRCOG Consultant, Ob/Gyn Dept.
Blood Type.
Rh Alloimmunization (Isoimmunization)
Red Cell Alloimmunization in Pregnancy Case Presentation
Case presentation 1 Full term newborn baby
NEONATAL IMMUNE THROMBOCYTOPENIA
Practical Hematology Lab
Rh(D) Alloimmunization
ISOIMMUNISATION.
DR. RAZAQ MASHA, FRCOG Consultant, Ob/Gyn Dept.
Rh Disease.
The North Thames Anti-D Protocol Audit
A/Prof Helen Liley Newborn Medicine – Mater Mothers’ Hospital
Rhesus isoimmunization
Indication of Blood Transfusion in Newborns Dr Bijan Keikhaei Full Professor of Pediatric Hematology and Oncology Research Center for Thalassemia and.
COOMB’S TECHNIQUES MLS 522.
Rheusus iso-Immunization
Coombs test practical(3)
Rh blood system Difference between ABO and Rh blood types
Review of Blood type and Rh
Blood group and cross matching
PREDICTION OF OUTCOME IN ABO INCOMPATIBLE NEONATES WITH RESPECT TO MATERNAL IgG ANTI-A AND ANTI-B TITRE IN O GROUP MOTHERS Govt T.D Medical College,
Alloantibodies and pregnancy
Presentation transcript:

1 IMMUNOCYTOMETRIC QUANTITATION OF RHD POSITIVE FETAL RBC IN BLOOD OF RHD NEGATIVE MOTHERS USING ABBOTT CELL DYN SAPPHIRE COMPARATIVE STUDY USING KLEIHAUER TEST AS REFERENCE Dr Agnès MAILLOUX, Centre National de Référence en Hémobiologie Périnatale (Dr Y. BROSSARD) Hôpital Saint-Antoine, PARIS

2 RHD HAEMOLYTIC DISEASE OF THE NEWBORN (1) THE DISEASE Hemolytic Anemia (risk of fetal death) Neonatal hyperbilirubinemia (risk of Kernicterus) MECHANISM Hemolysis of RHD positive RBC coated with maternal IgG anti-D antibodies transfered via the placenta. ORIGIN OF MATERNAL ANTI-D PRODUCTION: Fetal RHD positive RBC entering the circulation of RHD negative mother during pregnancy or at delivery : foeto-maternal haemorrhage or FMH

3 RHD HAEMOLYTIC DISEASE OF THE NEWBORN (2) CURATIVE TREATMENT Antenatally : Fetal (cord) transfusion of RHD negative RBC Premature delivery Postnatally : Transfusion, Phototherapy PREVENTIVE TREATMENT: RH Immunoprophylaxis (Immune neutralisation of RHD positive fetal RBC) Ante and postnatal administration of RHD Immunoglobulin in RHD negative pregnant women

4 RHD HAEMOLYTIC DISEASE OF THE NEWBORN (3) ≈ 4% of cases ≈ 0,8 ‰ (700 cases per year) 2006 ≥ 12% of cases5 to 6 ‰ 1966 MORTALITY & SEVERE MORBIDITY INCIDENCE (for 1000 births ) FRANCE Biological antenatal screening Improvements in neonatal and fetal medecine IV fetal transfusion RHD immunoprophylaxis (RH immune globulin) of fecondity index

5 IMMUNOSUPRESSIVE EFFICACY of RHD Immunoglobulin RELIES ON :  The delay of RHD Ig administration after passage of RHD antigen in maternal circulation:optimal administration time  72 hours The ratio of anti-D IgG/volume of fetal RHD+ RBC: Anti-D IgG  at 20 µg/mL RBC: 100% efficacy Optimal ratio derived from 9 studies of dose efficacy in RHD negative male volunteers: Anti-D IgG  5 µg/mL RBC : no or minimal efficacy Anti-D IgG = 10 to 17.4 µg/mL RBC : sub-optimal efficacy

6 RH IMMUNOPROPHYLAXIS RECOMMENDATION GUIDELINES exist throughout Europe for the use of RHD Ig The French guidelines (updated in 2005) require: For 100 % efficacy, the patient must received at least 20 µg anti-D IgG/ml of fetal RHD+ RBC (example : For an hemorrhage of 50 ml fetal RBC : 1000 µg anti-D IgG (i.e 50 x 20 µg) Quantification of FMH to adapt the dose in case of : Delivery Fetal death Abdominal trauma

7 QUANTITATION OF FMH KLEIHAUER TEST is performed routinely for quantitation of FMH in our laboratory September 2005 to November 2006 : 6490 Kleihauer tests NUMBERFREQUENCY O Fetal RBC/ Maternal RBC % < 1 to 273 Fetal RBC/10000 maternal RBC % Uninterpretables cells*2223 %  PROBLEMES WITH KLEIHAUER TEST:.Manual technique, without standardization, requiring trained technicians..Difficulties to diferentiate fetal cells from maternal cells with High content of HbF (*false positive or uninterpretable smears)

8 AIM OF THE STUDY TO VALIDATE AN INTERESTING ALTERNATIVE TO QUANTITATE FMH USING AN IMMUNOCYTOMETRIC METHOD - Technique derived from the Abbott Cell-Dyn CD4000 (Little, 2005) : Using a Fluorescein Isothiocyanate–labelled monoclonal anti-RHD (BRAD3) - Correlation of this technique adapted to the Cell Dyn Sapphire with the Kleihauer test in selected clinical specimen with or without FMH - Determination of Low Limit of quantification (LLQ) - Testing the impact of the number of aspirations with Cell Dyn Sapphire

9 MATERIAL AND METHOD CELL-DYN SAPPHIRE. Whole Blood : 50  l. Anti-RHD FITC (BRAD3) : 5  l. Incubation (30’ at 37 °C). Addition of 100  l of sapphire diluent. 3 aspirations. Data collection. Analysis of data : FCS Express Software KLEIHAUER TEST.Blood smear : fixed in alcohol (10’). Acidic elution at 41°C (5’). Staining with Phloxin (10’). Microscopic examination (x25) MATERIAL : - Comparative analysis of 86 selected clinical blood specimens of RHD negative mothers at delivery based on Kleihauer test (63 pos, 23 neg) METHOD :

10 RESULTS : KLEIHAUER TEST FETAL RBC : still haemoglobinized are staining by phloxin Result of a Kleihauer test at 500 fetal RBC / Maternal RBC : 250 ml of fetal blood Duration of testing : 1 hour ADULT RBC : de-haemoglobinized appear as « ghosts »

11 RESULTS : CELL DYN SAPPHIRE Sample 1 Aspiration 1 Sample 1 Aspiration 2 Sample 1 Aspiration 3 Sample 1 Merged Samples Sample 1: KT 3/10,000 RBC 4.1/ / / /10000 Rep CV 17 % Sample 2 Merged Samples Sample 2 Aspiration 1 Sample 2 Aspiration 2 Sample 2 Aspiration 3 Graphical displays of two representative samples comparing single and merged samples analyses. Sample 2: KT 36/10,000 RBC 46.5/ / / /10000 Rep CV 2.68%

12 Polynomial regression analysis determining the relationship between triplicate mean and CV%. Analysis of 58 samples; Kleihauer test ranging between 0 and 66 HF/10,000 HA. RESULTS : DETERMINATION OF LLQ The observed LLQ (Lower Limit of Quantification) with a CV of less than 15% was found at a value of 5 HF/10,000 HA

13 RESULTS : CORRELATION Analysis of 58 samples with Kleihauer test ranging between 0 and 66 HF/10,000 HA (a) Plot (a): single aspiration with the Cell Dyn Sapphire R2 = 0.90 Passing & Bablok analysis comparing Kleihauer test and cell-Dyn Sapphire (b) Plot (b): merged triplicate aspirations with Cell Dyn Sapphire R2 = 0.93

14 RESULTS : CORRELATION Analysis of 48 samples with a Kleihauer test ranging between 0 and 20 HF/10,000 HA. Plot (a): single aspirations with Cell Dyn Sapphire (a) R2 = 0.89 Passing & Bablok analysis comparing Kleihauer and Cell Dyn Sapphire (b) Plot (b): merged triplicate aspirations with Cell Dyn Sapphire R2 = 0.89

15 Altman-Bland bias analysis of agreement between the Kleihauer and Cell Dyn Sapphire estimates of FMH for analysis of 48 samples with Kleihauer test ranging between 0 and 20 HF/10,000 HA. Plot (a): analysis for single aspirations with Cell-Dyn Sapphire. Mean bias for Cell Dyn Sapphire is Plot (b): analysis for merged triplicate aspirations with the Sapphire. The mean bias for Cell Dyn Sapphire is (a) (b) RESULTS

16 DISCUSSION RESULTS are EXCELLENT : Good correlation of FMH quantification with Cell Dyn Sapphire compared with Kleihauer test. Acceptable sensitivity: LLQ : 5/ ONE PRECAUTION: Cell Dyn Sapphire analysis should include data from 3 aspirations ADVANTAGES OF CELL-DYN SAPPHIRE : Easier and faster than KLEIHAUER for laboratories not using routinely this manual test. Well adapted to emergency Solution for uninterpretable results BEST REPEATABILITY, REPRODUCIBILITY than Kleihauer DISADVANTAGES : Limits of indication to RHD immunoprophylaxis. Not usable for FMH in all pregnant women SOFTWARE not integrated in Sapphire: necessity of data transfer ABSENCE of quality controls

17 CONCLUSION FMH QUANTITATION ON CELL DYN SAPPHIRE A simpler technique for laboratories not trained to perform Kleihauer test to quantitate FMH for RHD immunoprophylaxis Specificity, sensibility and precision of this technique makes it a reliable alternative Quantitation of FMH possible in few minutes at every time for all laboratory equipped with a Cell Dyn Sapphire running 24/7