Monday – VSP Room weekly checks Visually Check: Hvac system for leaks & valve settings Fresh water system for leaks & valve settings VSP linkage Autopilot.

Slides:



Advertisements
Similar presentations
2.3 Waste Management – Revised IBTS
Advertisements

CHAPTER 45 Engine Lubrication.
Part III –Property Condition Report
HEAT PUMPS.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
Stanley HP-1 Compact Power Unit.
CASE STUDY-III BOILER TUBE FAILURE. The Incident  Boiler Make: MIURA  Date: March 26, 2010  Place: At sea  Initial Indication: Frequent water being.
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
GNI0003H PP1 Loop Trainer. GNI0003H PP2 Reason for Study Because the Loop Trainer gives instructors the capability to control water flow, pressure and.
Reservoirs Covered in Ch. 5 of Vickers Text
Filter manifold Holding tank Iron- manganese filter Aeration tank Control unit Pre- filter To storage tanks Backwash overflow SO2 vent Bypass Cutoff valve.
1B-1 Fire Engine Maintenance Unit 1B – Pump Inspections and Maintenance.
Bench Testing, Maintenance, and Troubleshooting.  Identify three primary steps in bench testing a helitorch.  Identify six considerations in maintaining.
Fresh water system. Matter to be decided: Potable water Wash water Pressure in the system: usually 10 to 40 psi 69 to 275 kPa 0.69 to 2.75 bar.
Dennis Sabre Fire Appliances
Bilge System.
Heating and Air-Conditioning Service
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Hydronic Mechanical Controls
Hydraulics For The Long Term
2013 NATEF Task Area A-7 Heating, Ventilation, and A/C A. A/C System Diagnosis & Repair B. Refrigeration System Component D & R C. Heating, Ventilation.
Engine Information & Engine Components and Systems.
Lesson 17 KEEPING WATCH. WATCHKEEPING 4 STCW 1978 (1995) 4 Watch (1) time period; (2) personnel 4 Personnel: Engineer officer in charge (watchstanding.
Survey Results from 2014 presentation: Maintenance of Conditions/Change in Conditions Robbie Walker.
10 energy saving tips for the house. Switch off the lights when not in use.
exhaust regulator valve
Tweety Operation Manual. Refurbish History Motor 1) Cummings Diesel (V6), ) Red Line 3000 (hums at 2800) 3) Top Speed 60 MPH.
Troubleshooting Small Engine Systems Jason Spurlin 4/10/02 Virginia Tech Edited by the CTAE Resource Network February 2011.
Las Delicias Water Supply System OPERATION AND MAINTENANCE MANUAL 1.
Student Book © 2004 Propane Education & Research CouncilPage Reducing Cargo Tank Vapor Pressure Using a Plant Compressor In order to use.
Eco-Winter Installation. – Step 1 – Mount Eco-bypass to water heater.
Claudio Bortolin 03/09/2012. SPD (RP analyses required) 1) Pump 17b replacement and leak test 2)Pressure test on the old inlet lines (technicians coming.
Diesel Fuel - Fill Place all spill safety equipment where needed
DIESEL FUEL FILL 1.Secure Fireboat 2 to fueling dock, fueling vessel, or vessel to receive fuel (Fig ). 2.Develop communications as needed, including.
Fire Fighting Systems Fi Fi Mains ●White System: This system has a lower output as far as volume goes. This main supplies 3x Eductor/Hydrants (500 gpm).
Weekly Checks Monday – VSP Room Tuesday – Pilothouse System Controls Wednesday – Starboard / Engine Room Thursday – Foam Room Friday – Port / Engine Room.
HPU FILTERS LOW PRESSURE FILTER FROM APU UNIT. CLOSE APU HYDRAULIC FLUID VALVE. FILL FILTER WITH HYDRAULIC FLUID PRIO TO INSTALLATION. LUBRICATE GASKET.
Potable Water System General Locations and Operations.
BOAT Regulatory Gross Tonnage – 199 Registered Length – 96’7” Registered Breadth – 29’ Registered Depth - 13’3” Draft – 14’ 6” Air Draft – 46’
Raw Water System Flush By introducing fresh water into the cooling system, growth of sea life is reduced or eliminated keeping the raw water cooling pipes.
Power Distribution System General Location. Power Distribution The Main Switchboard is the hub of the electrical distribution system. Everything ties.
Red/Green Fire Fighting Systems Fi Fi Mains ●Red System: Port Side Fire Main supplies two Monitors. M7 (6000) gpm on centerline on the fwd Wheelhouse top.
Fire/General Service/Ballast Pumping Systems
Bilge Pumping Systems General Locations.
Machinery Cooling Water System Locations and Operations.
Automotive Heating and Air Conditioning CHAPTER Automotive Heating and Air Conditioning, 7e James D. Halderman | Tom Birch SEVENTH EDITION Copyright ©
Getting Underway – Engine room
Life Line. Belay Line Canteens Clean and change water.
Coolant Fill Coolant Check and Fill. Oil Fill & Dip Stick Main Engine Oil Fill Dip Stick Delo 400 – 40 wt. Engine Oil.
Clean Lube Oil Transfer System General Locations and Operations.
Wednesday – starboard side engine room weekly checks Cycle all valves on the starboard side of the engine room Check all systems, connections, valves,
UH-60A/L Fuel System.
AfterSalesTraining Welcome to AfterSalesTraining.
STORAGE AND MAINTENANCE OF LARGE FARM EQUIPMENT Prepared by : Von G. Peavy South Region Ag Mechanics.
MAINTENANCE INTERVAL SCHEDULE D6R TRACK TYPE TRACTOR 7AR EVERY 10 SERVICE HOURS OR DAILY.
ARÇELİK TİCARİ KLİMA EĞİTİM DÖKÜMANI APPENDIX.
Vertical Pump Motor Manifold Upgrade. VPMM Replaces Existing Pumps, Motors, Relief Valves, Check Valves, Discharge Filters, Pump Running Pressure Gauges,
3. Climate Control Systems Service Automotive – Heating & Air Conditioning Topics covered in this presentation: Gauge set and refrigerant Service ports.
General Locations and Operation
Used Lube Oil Transfer System
Climate Control Systems Service
Friday – port side engine room weekly checks
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
1. Check reaction 2. Check water 3. Check heater 4. Check gas
REPORT IN AUX MAC PAQUIBOL, MARK ANGELO B. ME31-A1 ENGR. ALMOJUELA.
SB Packing Automatic Downpuller Power Unit
Chemical Transfer.
CHAPTER 45 Engine Lubrication.
Emergency Electrical Power Supply for Buildings
Presentation transcript:

Monday – VSP Room weekly checks Visually Check: Hvac system for leaks & valve settings Fresh water system for leaks & valve settings VSP linkage Autopilot connections Ventilation fan switch and breaker Fuel Valves at the fwd tank for leaks & settings Fuel valves at the transfer pipe for leaks & settings

Monday – VSP Room Weekly Checks Cycle all valves in the VSP room Check oil level in the VSP units Check oil level in the VSP header tanks Check bilge for water and pump or suction as needed Check fresh water system for leaks Check hot water heater for heat Fill day tanks and check and record fuel level in the fwd fuel storage tank Pump out grey water tank as needed Check hydraulic oil storage tank level – fill as needed Check and replace lights Check ventilation fan plenum for water – drain as needed Check general alarm bell & light Check phone & intercom # 107 Clean / wipe / wash / service all areas as needed

Monday - VSP Room Pump out grey water tank Cycle the overboard valve located on the starboard side Pump switch 50 gal. tank Overboard valve

Monday – VSP Room Fill day tanks Stick and measure main storage tank Measure sight gauge for the fwd storage tank Record fuel onboard Between each colored mark is 1000 gallons

Monday – VSP Room weekly checks Cycle VSP cooling overboard valves P&S Cycle HVAC overboard valve starboard side Cycle grey water overboard valve starboard side Port Side VSP cooling

Monday – VSP Room weekly checks HVAC overboard Grey water overboard VSP cooling Starboard Side

Monday – VSP Room weekly checks Check VSP unit oil level P & S Dipstick location Replace gently to avoid cross threading Operating range Look for signs of water (foam/milk)

Monday – VSP Room weekly checks Tank Fill Sight gauge Refill at this Level Discharge – Oil out

Monday – VSP Room weekly checks Remove / Lift floor plate and check for water NEVER PUMP OILY WATER OVERBOARD NEVER PUMP OILY WATER OVERBOARD Start pump and listen for prime – NEVER run dry – use prime valves if necessary Start pump and listen for prime – NEVER run dry – use prime valves if necessary Close all valves when finished Close all valves when finished Check under this floor plate On / Off VSP Room Valve Prime valves Bilge suction under floor plate