Status of Muon Tomography with SRS at FIT and some early beam results with SRS Michael Staib, Marcus Hohlmann Florida Institute of Technology Kondo Gnanvo.

Slides:



Advertisements
Similar presentations
Study of Large-area GEM Detectors for a Forward Tracker at a Future Electron-Ion Collider Experiment Aiwu Zhang, Vallary Bhopatkar, Marcus Hohlmann Florida.
Advertisements

Kondo GNANVO Florida Institute of Technology, Melbourne FL.
GEM Detectors for AnDY Nilanga Liyanage University of Virginia 1 Outline GEM chamber concept Large area GEM chamber projects Proposed GEM configuration.
CMS GEM Workshop III, April 20, 2012
Prototype of a Muon Tomography Station with GEM Detectors for Detection of Shielded Nuclear Contraband Michael Staib1 V. Bhopatkar1, W. Bittner1, K. Gnanvo1,2,
US CMS Phase 2 R&D Discussion 30-July-2013 “Phase 2 muon R&D” J. Hauser, UCLA  Add redundancy (power) to trigger where most needed  First and innermost.
Muon Tomography with compact Gas Electron Multiplier Detectors Dec. Sci. Muon Summit - April 22, 2010 Marcus Hohlmann, P.I. Florida Institute of Technology,
We have no control on the slow and sparse incoming muon flux Visualizing sufficient scattered POCA points in target volume satisfactorily takes long time.
A First Application for the Scalable Readout System: Muon Tomography with GEM Detectors RD51 Collaboration Meeting WG5 - May 25, 2010 Marcus Hohlmann with.
2012 IEEE Nuclear Science Symposium Anaheim, California S. Colafranceschi (CERN) and M. Hohlmann (Florida Institute of Technology) (for the CMS GEM Collaboration)
Advances in Reconstruction Algorithms for Muon Tomography R. Hoch, M. Hohlmann, D. Mitra, K. Gnanvo.
SPHENIX GEM Tracker R&D at BNL Craig Woody BNL sPHENIX Design Study Meeting September 7, 2011.
Experience with medium-size SRS for muon tomography Michael Staib Florida Institute of Technology.
Update on APV25-SRS Electronics Kondo Gnanvo. Outline Various SRS Electronics Status of the APV25-SRS UVa Test of the SRU with multiple.
Lead Tungsten Uranium Tin Iron Tantalum Abstract Muon tomography aims at detecting and 3D-imaging well-shielded high-Z material, e.g. nuclear contraband.
Updates on GEMs characterization with APV electronics K. Gnanvo, N. Liyanage, K. Saenboonruang.
Online Monitoring and Analysis for Muon Tomography Readout System M. Phipps, M. Staib, C. Zelenka, M. Hohlmann Florida Institute of Technology Department.
Muon Tomography Algorithms for Nuclear Threat Detection
Performance Expectations for a Tomography System Using Cosmic Ray Muons and Micro Pattern Gas Detectors for the Detection of Nuclear Contraband Kondo Gnanvo,
Large-area Gas Electron Multiplier Detectors for a Muon Tomography Station and its Application for Shielded Nuclear Contraband Detection K. Gnanvo 1, L.
Strip No Detection and Imaging of High-Z Materials with a Muon Tomography Station using GEM Detectors K. Gnanvo 1, W. Bittner 1, B. Benson 1, F. Costa.
Monte Carlo simulations of a first prototype micropattern gas detector system used for muon tomography J. B. Locke, K. Gnanvo, M. Hohlmann Department of.
Simulation of an MPGD application for Homeland Security Muon Tomography for detection of Nuclear contraband Kondo Gnanvo, M. Hohlmann, P. Ford, J. Helsby,
An MPGD Application: Muon Tomography for Detection of Nuclear Contraband Marcus Hohlmann, P. Ford, K. Gnanvo, J. Helsby, R. Hoch, D. Mitra Florida Institute.
HallA/SBS – Front Tracker PARAMETERDESIGN VALUE Microstrip Silicon Detector Number of tiles/plane and size2 Number of planes2 Size of the single
75 th Annual Meeting March 2011 Imaging with, spatial resolution of, and plans for upgrading a minimal prototype muon tomography station J. LOCKE, W. BITTNER,
WP4 STATUS AND OUTLOOK Hartmut Hillemanns TTN Meeting, December
Design and development of micro-strip stacked module prototypes for tracking at S-LHC Motivations Tracking detectors at future hadron colliders will operate.
First MT Prototype Station GEM Detectors for Muon Tomography of Nuclear Contraband A. Quintero 1, K. Gnanvo 1, L. Grasso 1, J. B. Locke 1, D. Mitra 2,
Update on SBS Back Tracker UVa K. Gnanvo, N. Liyanage, V Nelyubin, K. Saenboonruang, Seth Saher, Nikolai Pillip (visiting from Univ. Tel Aviv, Israel)
Statement of Interest in CMS MPGD High-  Muon Upgrade Florida Tech CMS Muon Group Marcus Hohlmann Florida Institute of Technology, Melbourne, FL, USA.
GEM R&D Update Kondo Gnanvo. Outline  GEM R&D and assembly facilities at UVa  Cosmic test results  Update on the 40 × 50 cm 2 GEM prototype  Plans.
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger,
GEM Trackers for Super BigBite Spectrometer (SBS) in Hall JLab The Super Big Bite Spectrometer (SBS) is one of the major new equipment in hall A in.
T.K. Hemmick. Background in SoLID Trackers Studies by Richard Holmes. PVDIS w/no baffles… 2 Signal Projective Bkg non-Projective Signal MIP BKG Large.
Simulation Study of Muon Scattering For Tomography Reconstruction
Fermilab Test Beam analysis for CMS GE1/1-III GEM detector Aiwu Zhang, V. Bhopatkar, M. Hohlmann, A.M. Phipps, J. Twigger Florida Institute of Technology.
News on GEM Readout with the SRS, DATE & AMORE
Update on the Triple GEM Detectors for Muon Tomography K. Gnanvo, M. Hohlmann, L. Grasso, A. Quintero Florida Institute of Technology, Melbourne, FL.
APV25 Electronics for GEMs at UVa and for the 12 GeV Upgrade Program in HallA at JLab RD51 Electronic School, February 3-5, 2014 Kondo Gnanvo University.
GEM Detector R&D at Florida Tech – “Get to know each other” –
2009 Florida Academy of Sciences at Saint Leo University, Saint Leo, Florida Performance comparison of the triple gas electron multiplier (GEM) and the.
M. Staib, M. Abercrombie, B. Benson, K. Gnanvo, M. Hohlmann Department of Physics and Space Sciences Florida Institute of Technology.
Live Event Display and Monitoring Program for a Muon Tomography Station Michael Phipps, Judson Locke, Michael Staib; Adviser: Dr. Marcus Hohlmann Department.
Florida Institute of Technology, Melbourne, FL
Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.
 The zigzag readout board is divided into eight η-sectors; each sector has a length of ~12 cm and comprises 128 zigzag strips; zigzag strips run in radial.
GEM-based Muon Tomography of Shielded High-Z Materials 10 th RD51 Collaboration Meeting, Stony Brook U., Oct 1, 2012 Marcus Hohlmann Florida Institute.
Abstract Beam Test of a Large-area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger,
Quality control for large volume production GEM detectors Christopher Armaingaud On behalf of the collaboration GEMs for CMS.
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
GE1/1-III GEM Cluster Size and Resolution Studies with the FNAL Beam Test Data Aiwu Zhang, Vallary Bhopatkar, Marcus Hohlmann Florida Institute of Technology.
Construction and beam test analysis of GE1/1 prototype III gaseous electron multiplier (GEM) detector V. BHOPATKAR, E. HANSEN, M. HOHLMANN, M. PHIPPS,
Abstract Muon tomography for homeland security aims at detecting well-shielded nuclear contraband in cargo and imaging it in 3D. The technique exploits.
RD51 GEM Telescope: results from June 2010 test beam and work in progress Matteo Alfonsi on behalf of CERN GDD group and Siena/PISA INFN group.
Detecting shielded nuclear contraband using muon tomography Judson Locke, William Bittner, Leonard Grasso, Dr. Kondo Gnanvo; Adviser: Dr. Marcus Hohlmann.
Abstract Muon tomography for homeland security aims at detecting well- shielded nuclear contraband in cargo and imaging it in 3D. The technique exploits.
The Muon Portal Project: A large area tracking detector for muon tomography Francesco Riggi Dept. of Physics and Astronomy, University of Catania, Italy.
SRS TIMING ANOMALY RD51 Mini-Week June 9, 2015 M. Phipps, BNL 1.
J. Helsby, P. Ford, R. Hoch, K. Gnanvo, R. Pena, M. Hohlmann, D. Mitra
Preliminary Performance of the L2 Chamber (Side A)
Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Speaker: Dr. Qite Li 李奇特 Co-author: Prof. Yanlin Ye, Jing Ma,
Large CMS GEM with APV & SRS electronics
Nathan Mertins, Michael Staib, William Bittner
Simulation Study of Muon Scattering For Tomography Reconstruction
Development of Gas Electron Multiplier Detectors for Muon Tomography
EIC Tracking Meeting, March 26, 2012
J. Twigger, V. Bhopatkar, E. Hansen, M. Hohlmann, J.B. Locke, M. Staib
Advances in Reconstruction Algorithms for Muon Tomography
Presentation transcript:

Status of Muon Tomography with SRS at FIT and some early beam results with SRS Michael Staib, Marcus Hohlmann Florida Institute of Technology Kondo Gnanvo University of Virginia RD51 Mini Week WG5 June 13, 2012

Muon Tomography for Homeland Security Photo: Sci. Am., 04/2008 Radiation Detectors But it is easy to avoid passive detection of nuclear threat material that is looking for radiological signatures. Just add shielding! There may be a solution... More than 23 million cargo containers and 93 million privately-owned vehicles were processed by U.S. Customs and Border Protection in the last year. New requirement: 100% scanning of all U.S.-bound containers using non-intrusive imaging equipment and radiation detection equipment to search for a nuclear threat.

Muon Tomography Concept μ μ FeU Large Scattering Small Scattering μ Iron Small Scattering Uranium μ Large Scattering μ μ Incoming muons (from natural cosmic rays) Note: Angles Exaggerated! Tracking detectors Multiple Coulomb scattering to 1 st order produces Gaussian distribution of scattering angles θ with width σ = Θ 0 :

Muon Tomography with Drift Tubes Brass Cu PbW Fe Al Original idea from Los Alamos (2003): Muon Tomography with Drift Tubes Reconstruction of 1 inch thick Pb letters J.A. Green, et al., “Optimizing the Tracking Efficiency for Cosmic Ray Muon Tomography”, LA-UR , IEEE NSS INFN : Muon Tomography with spare CMS Muon Barrel Chambers (Drift Tubes) S. Presente, et al., Nucl. Inst. and Meth. A 604 (2009) m 4.3 m Decision Sciences Corp.: Multi-Mode Passive Detection System, MMPDS TM INFN CMS Decision Sciences prototype using drift tubes large enough to scan a vehicle. C. Milner, et al., “Non-Invasive Imaging of Reactor Cores Using Cosmic Ray Muons”, SMU Physics Department Seminar, March 2012.

Compact Cubic-Foot Muon Tomography Station with GEMs Plastic Scintillator Triple-GEM Detector ~ 1 ft 3 Discriminator and coincidence card Two of the GEM detectors used were assembled at Florida Tech

SRS for Muon Tomography Current station configuration with 8 detectors: 96 APV Hybrid (48 M/S pairs) 6 ADC/FEC cards 2 Gigabit network switches Six 25 ns frames of data recorded for each APV per trigger yields event size of 30 Hz. DATE for data acquisition. AMORE for data decoding, event monitoring and data analysis. 6

Tomographic POCA Reconstructions of Target Scenarios Tomographic Reconstructions Presented Material discrimination performance using five targets. Depleted uranium shielded with medium-Z shielding. POCA Reconstruction Limitations Assumes multiple scattering is well approximated by a single point. Not valid in the case of large amounts of material! Statistical methods must be employed. Does not take into account the momentum of the muon. The POCA can be found using the fact that the shortest line segment joining the incoming and outgoing vectors will be orthogonal to both. Reconstruction Algorithm Point of Closest Approach (POCA) Object

Five-Target Scenario Lead Z = 82 ρ = 11.4 g/cm 3 X 0 = 0.56 cm Depleted Uranium Z = 92 ρ = 19.0 g/cm 3 X 0 = 0.32 cm Tungsten Z = 74 ρ = 19.3 g/cm 3 X 0 = 0.35 cm Tin Z = 50 ρ = 7.3 g/cm 3 X 0 = 1.21 cm Iron Z = 26 ρ = 7.9 g/cm 3 X 0 = 1.76 cm 6mm Al shielding Five 75 cm 3 targets were placed inside the imaging volume at three different Z locations.

Five-Target Scenario Single cluster track selection 155,104 reconstructed tracks NNP cut = 5 2 mm x 2 mm x 40 mm voxels Pb W Fe Sn U Results are good! Can discriminate between high/low Z as well as high/medium Z. Tungsten vs. Uranium not so easy... Results match 1/X 0 dependence quite well

Five-Target Scenario XZ Slices YZ Slices Sn +X +Y Fe U U Sn PbW W W Fe -70 mm < Y < -30 mm-20 mm < Y < 20 mm30 mm < Y < 70 mm 30 mm < X < 70 mm-20 mm < X < 20 mm-70 mm < X < -30 mm Single cluster track selection 155,104 reconstructed tracks NNP cut = 5 2 mm x 2 mm x 40 mm voxels

Stacked Five-Target Scenario Stacks of each of the five materials were imaged using the MTS Targets vary in size from 27 cm 3 to 150 cm 3 175,022 tracks reconstructed using single cluster selection

Stacked Five-Target Scenario Single cluster track selection 175,022 reconstructed tracks NNP cut = 6 2 mm x 2 mm x 40 mm voxels UraniumTungstenLeadTinIron Simple Scattering Density [deg/cm3] We are able to discriminate between the low/medium/high-Z materials! 40 mm slice 40 mm XY slice descending in Z by 5 mm per frame

Stacked Five-Target Scenario WPbWFe UU Sn Fe SnPb Single cluster track selection 175,022 reconstructed tracks NNP cut = 6 2 mm x 2 mm x 40 mm voxels XZ Slices YZ Slices

Depleted Uranium with Bronze Shielding Mixed track selection 187,731 reconstructed tracks 2 mm x 2 mm x 40 mm voxels 40 mm XY slice with NNP cut increasing by 1 per frame The shielded uranium can be discriminated from the bronze shielding using POCA reconstruction

Depleted Uranium with Bronze Shielding Mixed track selection 187,731 reconstructed tracks 2 mm x 2 mm x 40 mm voxels XZ slice with NNP cut increasing by 1 per frame The shielded uranium can be discriminated from the bronze shielding using POCA reconstruction YZ slice with NNP cut increasing by 1 per frame What about the side views?

Status of Muon Tomography We have shown the ability of the MTS using GEMs to discriminate between materials of similar volume with different Z, even as shielding. SRS is working very well! Still unresolved issue of network switch requirements and exact cause of missing triggers. Will try to implement the zero suppression firmware soon and work on clock synchronization. Plans to possibly scale to ~1 m 3 active volume in the future. Many thanks to Sorin, Hans, Filippo and Leszek for their help throughout the process.

CAD Design by C. Pancake, Stony Brook 2 mm Beam Test 2012 Zig-Zag (Chevron) strips to reduce readout channels while maintaining spatial resolution Preliminary Results

Zero Suppression Raw DataPedestal Subtracted Data Zero Suppressed (5σ RMS) DataTime Evolution of Zero Suppressed Signal Floating channels (not connected) 48 Zig-Zag RO Strips Strip Number

Mean = 2.7 Strips Mean = 1.1 Clusters Pedestal Noise Cluster Charge Distribution Cluster Size DistributionCluster Multiplicity

Beam Test 2012 New RD51 tracker with resistive strip MicroMegas and SRS APV readout Readout Strips parallel to resistive strips Readout perpendicular to resistive strips

Thanks! Questions?

Backup Slides

Post-Processing to Remove Noise A “number of neighboring POCA ” (NNP) cut is made in order to improve the quality of the reconstructions. There is also a cut removing all voxels with mean scattering angle less than 2 degrees. V Add up the total number of POCA points in the blue voxels surrounding voxel V, this is the NNP. If the NNP is less than a threshold, remove the contents of voxel V. Repeat for all voxels in the histogram. MethodResults