MULTISTACK WORLD-WIDE HEADQUARTERS SPARTA, WISCONSIN.

Slides:



Advertisements
Similar presentations
XEnergy Technologies Energy Efficiency Through Creativity.
Advertisements

DOE - Chiller System Optimization Opportunities With Gas Engine-Driven Cooling Systems.
New York Life Building 20 West Ninth Street Mike Thome Hoss & Brown.
Overview of Collected Integrated Chiller Retrofit Case Studies Dr. Lisa Gartland (510) ,
Jamesway Incubator Company Inc. HRS System By Dominic Babineau, Engineer.
Partnership Gwinnett + Southeast Green Series- Debunking Energy Efficiency Myths: Why your bottom line depends on Energy Efficiency Property of VIS VIVA.
The Value of DOD Installation Energy Management Control Systems (EMCS) and Command Centers for Improved Operations and Increased Energy Efficiency Moderator:
Variable Frequency Drives VFD Basics
Heat pumps and their economics. There has been fluctuations before Johnson Controls2.
Johnson Controls1 YORK Model YVAA Air-Cooled Chillers Variable Speed Screw, tons.
Engineer Presentation
ASHRAE Presentation: VRF Overview Mitsubishi Electric Presenter: Phone number ©2011 Mitsubishi Electric& Electronics USA, Inc.
© ABB-EWEC 2006 ATHENS /03/06 EWEC 2006 Athens The Challenges of Offshore Power System Construction Peter Jones Lars Stendius ABB.
Team 2: Kelly Foster Chad Mills Lirjon Llusho Dave Rosso September 30, 2009.
Overall issues for adequate design for high-ambient temperature operation by: Samir Hamed Petra Engineering Ind. Co. Rtoc member.
UTSW Thermal Energy Plants, Power Generation and Electrical System What do we do to meet the Emission Reduction, Energy usage Reduction and Electrical.
Mammoth Product Training
Presentation Outline Introduction CHP Analysis Electrical Analysis Acoustical Analysis Thermal Storage Analysis System Optimization Analysis Conclusion.
By Coffman Electrical Equipment April Allows for simple integration with renewables.
RLC-CMS002-E4© American Standard Companies, inc All Rights Reserved Concentration of intelligence, High reliability. Series R TM.
Motors and Compressed Air MAE 406 Energy Conservation in Industry Stephen Terry.
 Install new air cooled high efficiency screw chiller (variable speed)  Install new fan coils with ECM motors and low temperature heating coils and proper.
CNN Center John Hester Turner Properties, Inc.. CNN Center Built in ,583,000 square feet on 18 floors Five structures joined by a common atrium.
The new Super Multi from TCUK
Air conditioning – Refreshes your life EWTP MBY Applied Systems Sales1 EWTP-MBYNN Air-cooled Heat Recovery.
Foothill College & Space Science Center Bill Kelly Viron Energy Services (510) ext 13,
Technology details, potential and experiences of Trigeneration
Smartcool Systems Inc. Providing effective and reliable energy efficiency solutions for HVAC-R customers around the globe.
Flooded Screw Chiller FWSF Electronic Expansion Valve Condenser Evaporator Control box compressor Flooded Screw Chiller - FWSF.
Marriott Corporate Headquarters
/ 1 ERA A chiller to suit everyone. Air cooled water chillers Free-cooling chillers Air/water heat pumps.
BCWC Water-cooled water chillers with centrifugal compressor/s
1 BREC Air-cooled water chillers BREF Air-cooled water chillers with free-cooling system 1602A A A A A 3202A A A -
Energy Efficient Data Centre Design
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
IMPROVING THE EFFICIENCY GEOTHERMAL or GROUND SOURCE HEAT PUMPS.
Building Systems Integration - Energy and Cost Analysis The Milton Hershey School New Supply Center Justin Bem AE Senior Thesis – Spring 2007 Mechanical.
Water is the Natural Choice Water: The Natural Choice For Efficiency – Unit efficiency versus Building System efficiency – Equipment Ratings EER and COP.
Water is the Natural Choice Hydronic Comfort Systems Increase and Maintain Building Efficiency For the Life of Your Building
Water is the Natural Choice Water: The Natural Choice For Efficiency – Building System efficiency not just a unit rating – Equipment Ratings EER and COP.
Kansas City International Airport Michael Glasker, P.E. George Butler Associates, Inc.
Second Nature ® Compact Chiller Leading the way in secondary coolant refrigeration systems. SNCC.
ClearFire-LC Hydronic Boiler Solution. ClearFire Family Capacities from 400 to 12,000 MBH 2 ClearFire-H - Steam ClearFire-C - Condensing ClearFire-V -
Prepared by : Nishant .A. Raval
2016 Chiller New Products Presentation.
Revolutionary Breakthrough in Optimized Marine Design Introducing Turbo Technology from Dometic Environmental.
Air Cooled Chillers with High Speed Centrifugal Compressors.
GeoExchange / Thermal Energy Storage Systems Reduce Overall Energy Use and Peak Demand.
I-RACH range I-RACH range I-RACH range I-RACH range High efficiency air/water heat pump with INVERTER scroll compressor Range Modularity Components Highlights.
Changes for 2016 Moving Forward! 2016 ECM Fan Box Bright Energy Solutions! LED High Bay! Chillers! Ready for 2016.
CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS
Exhaust Heat Recovery Systems
Elliott Microturbines Absorption Chiller Integrated System Development
Compact line ‘EW*D~J-’ water-cooled chiller range
HYDRONIC HVAC: The Most Comfortable and Efficient System
AdaptaPAK The sustainable, energy-efficient outdoor refrigeration solution.
HYDRONIC HVAC: The Most Comfortable and Efficient System
WELCOME Indoor Chillers.
High Quality ECONET Manufactured by Manor
New Air Cooled Scroll Chiller
Munters DOAS, Chilled Beams and VRV
WELCOME Indoor Chillers.
Title RTWD Water-Cooled Chillers subtitle START
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRK Sales Training Program
What is Ecomesh and What are the applications of Ecomesh?
BSE Magnetic Levitation Oil Free Centrifugal Chiller Traditional Chiller.
NRL NRL - Welcome to the NRL Sales Training Program
Presentation transcript:

MULTISTACK WORLD-WIDE HEADQUARTERS SPARTA, WISCONSIN

MULTISTACK OVERVIEW 2009 is the 20 th Anniversary for Multistack Multistack is the recognized world leader in modular chillers Customer service is the main priority at Multistack. If you need it and we don’t make it, we will try to make it for you Multistack has a team of service technicians that travel the world for start-ups Available in individual modules or pre-assembled into arrays on lifting frames Multistack offers both sales and service schools in our Sparta, Wisconsin facility In-house test stands for Witness Testing In-stock standard modules make for very quick shipments for emergency retrofit installations

AHRI CERTIFICATION Air-Conditioning, Heating, and Refrigeration Institute Multistack is AHRI Certified and continues to certify products as they are developed AHRI Certification provides real performance data Multistack has AHRI approved and certified test stands in-house

What are modular chillers and why do you want them in your building? Compact Design Easy Installation—Fits Through Office Door No Crane Required Retrofit or Replacement Built-in Redundancy Critical Cooling Future Capacity Low Maintenance Low Sound Signature Stock Availability for Short Lead Time Shipping Energy Efficiency—Only Run The Modules You Need Multistack Production Chillers are AHRI Certified The future of modern building efficiency is modular because… There is nothing more efficient than off

Water-to-Water MS50 Air-to-Water ASP30 MULTISTACK MODULES

Multistack is not just about Modular Chillers brought the introduction of full-size Flooded Units Flooded Units available in tons Built to order in wide or tall designs

Theory of Modular Chillers Multiple smaller chillers connected in parallel allow array to meet building demands at peak times, but shut down modules when demand is lower. Modules use screw, scroll and centrifugal compressors Modular systems can easily be expanded for future building growth Redundancy is built-in. No need for a back-up chiller system when you have multiple compressors in parallel Installation is easy—individual units fit through office doorways and on elevators. No need for a crane or demolition Small footprint, low sound signature, AHRAE 15 compliance and more Dedicated Heat Recovery Chillers and Water-to-Water Heat Pumps integrate into arrays

COMPLETE MULTISTACK MODULAR CHILLER ARRAY

20, 30, 50 and 70-Ton Modules Chillers from 20 to 600-Tons 410A Scroll Compressors.740 kW/Ton As quiet as 60 dB (A) Scroll Modules

70, 90 and 125 Ton Modules Copeland Screw Compressor 140 to 1000-ton arrays.75 kw/ton 72dB(A) Currently Available in R-22, with 134A In Design Now Large Screw Modules

Magnetic bearings; no oil IPLV.435 kW/ton Quieter than background noise 2 A peak current inrush R-134A refrigerant Magnetic Levitation Technology MagLev™ for Multistack

Flooded Units Energy Efficient MagLev™ Technology Best Part-Load Efficiency Industry Leading Control Panel Available Tons

Water-To-Water Heat Pump Chiller 20,30, 50 & 70 Ton Modules Arrays from Tons Single Point Water Connection Single Point Power Connection EER’S > 17 at 45 Degrees COP’S > 4.0 at 120 Degrees

Dedicated Heat Recovery Chiller High Temperature Chiller Boiler Available in 140-, 160- and 180- Degree Modules Typically Three Times More Efficient Than Gas Boilers Compatible With High-Temp Hot Water System

Air Cooled Modules Split Version of W/C Remote A/C Condenser Refrigeration Specialties Installed Within Cabinet Dimensions in Factory Controlled Environment Same Size as W/C

High Efficiency Air-Cooled 410A Scroll Modules Available in 10-, 15-, 20-, 30 and 60-Ton Modules Industry Leading Efficiency Incredibly Low Sound Signature Critical Cooling Applications Environmentally Responsible Refrigerant Single Point Control System MagLev™ Modules available End-To-End or Side-By-Side Can Be Packaged To Create Chillers Up To 600-Tons High-Static Condenser Fans Available

Aero Thermal Air-to-Water Heat Pump Three Times Cost Savings Versus Natural Gas Economically Friendly Upgrade For Two-Pipe Systems Available in 10-, 15-, 20- and 30- Ton Modules Cost Reduction By Eliminating Well Drilling

Minimal refrigerant charge is safer for the environment and less costly. Significantly quieter operation than a full-sized chiller. Oil-free refrigerant system means that oil cannot make its way onto the heat transfer surfaces and degenerate the efficiency of the system. Required electrical startup current for MagLev compressor is just 2 amps versus a full size compressor requiring amps. A MagLev compressor’s weight is one-third of what a conventional compressor of similar capacity would be. It requires significantly less material and energy to manufacture a MagLev compressor, adding positively to carbon footprint reduction process. Magnetic Levitation (MagLev) Compressor Highlights

The heart of a Multistack MagLev Chiller is the Magnetic Levitation High Speed Compressor. Capable of spinning up to 40,000 rpm, the Multistack control system allows the compressor to offer maximum efficiency at almost any level of building demand. Two stage impeller offers exceptional part load efficiency MagLev™ Compressor Highlights Built-in computer to constantly monitor operation and diagnostic systems

Variable Simultaneous Heating and Cooling Dramatically Reduces Piping and Electrical Costs Installed Footprint Meets Architectural Limitations Fully Expandable Modular System Multistack Controls Simplify System Operation Virtual Moveable End Cap--VME

Virtual Moveable End Cap (VME)

GEOTHERMAL HEAT PUMP WITH VME TECHNOLOGY

Simultaneous Chilled and Hot Water Easy Addition to any Hydronic System One to Four Year Payback 75% Reduction in CO2 Emissions 10 Tons to 1000 Tons Hot Water Temps as High as 180°F Use Heat Created Cooling Your Data To Make Hot Water DEDICATED HEAT RECOVERY CHILLERS DHRC

180-Degreee DHRC

CRITICAL COOLING APPLICATIONS Anywhere Redundancy is Required Data Centers Hospitals Operating Rooms Industrial Process Applications Manufacturing Applications Telecommunications Pharmaceutical Multiple Modules in Array Eliminate the Possibility of Single Point Failure N-1 is Always Greater than Zero N+1 is an Additional Module, Not Another Chiller System

REDUCE INSTALLATION COSTS WITH MODULAR CHILLERS Multistack Modules fit Through Standard Doorway Multistack Modules Designed to Ride Elevator No Crane Needed for Installation of Individual Modules Demolition and Construction Avoidance ASHRAE-15 Compliant Without Costly Mechanical Room Upgrades Single Point Power and Water Connections Standard

Multistack 1065 Maple Ave Sparta, WI (608)