Schematic Lighting Design Natty Boh Building Baltimore, Maryland Eric Singley Penn State University Architectural Engineering.

Slides:



Advertisements
Similar presentations
Changing Your Fixture? What to consider….. There are lighting types and options to suit just about everyones tastes and every location that you can imagine.
Advertisements

The Franklin Care Center Addition and Renovation Franklin Lakes, New Jersey Jennifer Curley Lighting/Electrical Option Faculty Advisor: Dr. Moeck.
Thesis Presentation April 13, 2004 Brian Regan The Virginia Historical Society Building Lighting/Electrical.
Hall Corporate Headquarters Dan Rusnack Tuesday April 13 th, 2004 Lighting/Electrical Emphasis Thesis Presentation Thesis Presentation.
UPSTAIRS DOWNTOWN North Walnut Case Study for Reuse Anna Margaret Barris Project Designer Illinois Historic Preservation Agency.
Urban Art Bar. scrawl 2002 Objective To introduce modern day urban art to Scotland through a major part of it’s culture… Drink To become a part of the.
NEW MERCY CENTER. Dramatic 35 foot tall Bright Silver Building entrance cross. Recognition by custom engraved plaque. This Cross will be up lit at night.
Chapter 9 Store Design and Visual Merchandising.
Lighting 4.05 Sherry Brooks. Can emphasize the best features of a room Effects the way a room can be used. Inadequate light causes eye strain, affect.
Lisa Bornemann Lighting/Electrical Independence Visitor Center Philadelphia, PA INDEPENDENCE VISITOR CENTER PHILADELPHIA, PA LUTRON LIGHTING PRESENTATION.
 General Lighting - provides an area with overall illumination. Also known as ambient lighting, general lighting radiates a comfortable level of brightness,
CNBC Global Headquarters Lighting Design by: Christine Cajilig Lighting/Electrical Advisor: Dr. Mistrick.
Lighting Calculations
Building Information Located in Washington DC on the George Washington University Campus Addition to existing Business School 170,000 Sq Ft 6 floors above.
Brad Gaugh November 29,  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2.
It costs no more to build a house with a good plan, than one with a poor plan…….in fact, it may cost less.
Building Statistics Owner – Dansko, Inc. Owner – Dansko, Inc. Manufacturer of shoes sold in over 3500 stores in the US and Canada Manufacturer of shoes.
Changes to Mandatory Title 24 Lighting Requirements Bill Blackley LC Director Product Marketing California's new building energy efficient standards took.
New Jersey Center for Science, Technology, and Mathematics Education John P. Mulhern November 21, 2008 Schematic Presentation.
Ballenger East Building Final Presentation Design Development Architectural Engineering Senior Thesis Presentation 2009 Lighting / Electrical Option Student.
Proposed Alternative to the Curved Wall Concept Friends of the Orange Depot By J David Derosier 1.
Jason Weaver 12/13/2007 Ann and Richard Barshinger Life Sciences & Philosophy Building Franklin & Marshall College Lancaster, PA.
NEW COMMUNITY FACILITY Adam Kroll - Lighting / Electrical - Consultant: Dr. Richard Mistrick - Tech 3: Schematic Design.
Rendering and Light Maps.  Draw the light that you want to create for the space.  Use yellow, yellow orange, orange pencils  Indicate where you wish.
Kitchen & Bath Lighting. A good lighting design should: Look good – both people and design space Provide the proper amount of light in every room Be.
Understanding Floor Plans
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
1 ISE Differences between office and factory layout Product  Offices process information  Factories produce things Physical environment  Offices.
Kempen & Co 0 Immofinanz: Na Prikope 14 & Jindřišská 16.
It costs no more to build a house with a good plan, than one with a poor plan…….in fact, it may cost less.
Schematic Design Proposal Dan Rusnack 11/14/03 Lighting/Electrical option Thesis project The Hall Corporate Headquarters.
Wegmans Fairfax Schematic Design Joseph Lookup The Pennsylvania State University 5 th Year - Architectural Engineer Lighting/Electrical.
Andrea Hauber; L/E AE Dr. Martin Luther King Jr. Library; San José, California 04/13/03; Consultant: Prof. Mistrick Outline of the Final Presentation T.
FLUORESCENT LUMINAIRES Fluorescent Luminaires U.S. Department of Energy Rebuild America Business Partners And Lithonia Lighting.
 Diffuse Light – fills in shadows – reducing contrast.  Diffuse sources deliver light evenly in every direction. Lamp itself  Diffused sources can be.
Rosegarden Branch Library San Jose, CA Miory Kanashiro Lighting/Electrical Option Primary Consultant: Professor Mistrick.
Rosegarden Branch Library San Jose, CA Miory Kanashiro Lighting/Electrical Option Primary Consultant: Professor Mistrick.
Maryland Transportation Authority Police Training Facility Schematic Design Presentation December 13, 2007 Leah Clark.
Lutron Thesis ProposalCorron Cultural CenterSara Lappano Sara Lappano, EIT, LC-Intern Lighting/Electrical Option.
Center for the Arts Towson, Maryland Schematic Lighting Proposal Ben Mitten Architectural Engineering Pennsylvania State University.
INTD 52 entrances—setting the tone. planning take lighting needs into consideration at the beginning of a project—less costly and doesn’t end up looking.
  Provide a library link at an existing campus crossroads and a new face for the combined Deering Library/ University Library complex  Strengthen the.
Lighting Systems: Electrical Sources Chapter 3 Part 2 © 2006 Fairchild Publications, Inc.
Newseum and Freedom Forum Headquarters Washington, D.C. Ryan Wise Lighting/Electrical Option Consultant: Dr. Mistrick Dec. 14, 2007.
Thesis Lighting Design Proposal Dan Rusnack 12/9/03 Lighting/Electrical option Senior Thesis project Hall Corporate Headquarters.
Howard County General Hospital Schematic Design Proposal Casey Schardt.
Forest View Elementary School Everett, Washington Elementary School Project of Distinction DYKEMAN 2008 Exhibition of School Planning and Architecture.
AT – 201 Introduction to Architecture Dan Trent August 28,
Howard County General Hospital
Dorrance H. Hamilton Building
The School Of Forest Resources Building University Park, Pennsylvania Chris Hoyman The Pennsylvania State University Architectural Engineering Lighting/Electrical.
INTERIOR DESIGN STAR EVENT. MEET YOUR CLIENTS The home is laid out similarly to this ranch home. THE SPACE.
North Hills Junior High School Schematic Lighting Design
Schematic Lighting Design Natty Boh Building Baltimore, Maryland Eric Singley Penn State University Architectural Engineering.
Broadway Plaza Schematic Lighting Design Diane Emert The Pennsylvania State University Architectural Engineering Lighting/Electrical Option January 2004.
Dubois Education Foundation Workforce Technology Building Schematic Design Josh Lutton Dr. Moeck January 2005.
Newseum and Freedom Forum Headquarters Washington, D.C. Ryan Wise Lighting/Electrical Option Consultant: Dr. Mistrick Dec. 14, 2007.
Harris Theater for Music and Dance Chicago, IL Lindsey K. Beane Lighting/Electrical AE Senior Thesis 2006.
IECC 2012 Standard Lee Brandt, LC, IALD, LEED AP BD+C Principal HLB Lighting Design.
Von Liebig Center for Science Juniata College Huntingdon Pa Lutron Lighting Presentation Derek Sitosky.
Lighting 4.05.
Lighting Wala Al-Zaharni Section /201.
INDEPENDENCE VISITOR CENTER PHILADELPHIA, PA LUTRON LIGHTING PRESENTATION DECEMBER 10, 2002 BY LISA BORNEMANN Independence Visitor Center Philadelphia,
Concept Lighting Proposals
Greenwich Academy Upper School
The AstroPower Headquarters Newark, Delaware
for home lighting design
Lighting.
254 East Union Street Pre Development Plan Review
Floor Plans and Symbols
Presentation transcript:

Schematic Lighting Design Natty Boh Building Baltimore, Maryland Eric Singley Penn State University Architectural Engineering

Location Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Brewers Hill Baltimore, Maryland

Project Information Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Building Statistics:  Overall Building Size : 189,550 ft 2.  Maximum Height : 9 stories  Multi-purpose: office, storage, residential, commercial Building Character:  Old home of the Gunther Brewing Company.  Consists of 6 sections of differing heights.  Declared a historic place in 2002.

Design Spaces Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal  Large Work Space Friday’s Day Care Center  Circulation Space Canton Self Storage Lobby  Outdoor Space Parking lot and rear facade  Special Purpose Space Countrywide conference room

Day Care Center Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Space Properties  Floor area 4092 ft 2.  Exposed ceiling at 14 ft.  Large windows on east and west walls.  Interior partitions dividing kitchen and storage areas. Space Tasks  Primarily play and learning area for small children.  Light kitchen use.

Day Care Center Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal

Day Care Center Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Design Goals  Separate the spaces by function.  Focus on the children’s area, all other spaces are support.  Create a comfortable atmosphere for the children to spend the day in.  Possible Ideas: Playful, Safe  Make use of the large windows to introduce daylighting to the space.  1.5 Watts per square foot allowed.  CCT 5000 to match daylight in space.

Day Care Center Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Design Solution  Separate the spaces.  Linear fluorescents in circulation spaces leading toward sub- spaces.  Atmosphere Ideas.  Suspend ceiling in children’s area for a more enclosed “safe” space.  Create multi-level ceiling and add colored light for visual interest.  Daylighting concerns  Use zoned switching to shut off lights near windows during the daytime.

Day Care Center Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Looking into children’s play area with wall removed.

Day Care Center Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Detail of uplights at corner of lower suspended ceiling.

Lobby Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Space Properties  Floor Area ≈ 2500 ft 2  Ceiling at 8 ft and 21.5 ft  No windows  Entrances on both levels Space Tasks  Light office work  Display of model storage unit  Sales / Receptionist desks

Lobby Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal

Lobby Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Design Goals  Direct customers to sales desk.  Accent wall spaces for company logo and decorative artwork.  Maintain a small number of unique luminaires within the complex space.  Flynn mode: Spacious  Maximum power density: 1.3 W / square foot  Target Illuminance values - 30 fc on work-plane at desks fc on floor throughout rest of space

Lobby Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Design Solution  Linear fluorescent’s directing customers down the stairs and into the space upon entering.  CFL downlights over each of the desk areas.  Spot lamps washing ceiling along 1’6” indent in lower section.  Linear wall-washers along wall in lower section and on the angled portion of the 2-story area.  CCT of 5000K to mimic daylight and make the lobby appear more spacious.

Lobby Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Two-story portion of the lobby

Lobby Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Looking in from street entrance with wall removed.

Conference Room Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Space Properties  Floor Area : 150 ft 2  Ceiling at 8 ft  Conference table with chairs  No windows Space Tasks  Professional and Casual conferences  Possible light video conferencing

Conference Room Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal

Conference Room Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Design Goals  Create a comfortable yet professional environment.  Provide flexibility to accommodate different uses. Including:  Roundtable discussion  Video conferencing -Target Illuminace ratios ( on participant’s head). Front / Side1: 1 to 3 Front / Side2 : 1 to 1.5 Front / Top: 2 to Prevent spill of light onto camera and monitor located in the front of the room

Conference Room Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Roundtable Discussion  Drop center ceiling 6 inches.  Light the space indirectly with linear fluorescent fixtures recessed in the side of the dropped ceiling.

Conference Room Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Video Conferencing  Switch off front 3 indirect fixtures.  Wash each participant with linear fluorescent from recessed fixtures as shown.  CCT : 4000 K

Conference Room Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal

Exterior Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Space Properties  Ground Area : 37,050 ft 2  Surrounded on 3 sides by buildings  Historically significant Space Tasks  Parking for Natty Boh Building  Entrance to the building

Exterior Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Design Goals  Provide sufficient light to allow drivers to read signs and see parking lines.  Call attention to the building entrances.  Achieve 100% Dark Sky compliance.  Maintain luminaire appearance for historical reasons. Power Density  0.3 Watts per square foot allowed

Exterior Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Design Solution  Spotlight building entrances.  Prevent spill into windows.  Keep light poles on existing islands.

Fin Natty Boh Building Penn State AEEric SingleySchematic Lighting Proposal Any Questions?