Paul Hagey, Eamonn F. Healy, St. Edward’s University,

Slides:



Advertisements
Similar presentations
Gas Chromatography There an be many parts to a gas chromatography system but the basic components include: An injection system. A column (controllable.
Advertisements

Everardo Macias, Patrick Tomboc Eamonn F. Healy, Chemistry Department,
Chromatographic Process Provides the analyte transport. Immobile phase. Mixture of components dispersed in the mobile phase.
Size Exclusion Chromatography
1 HPLC Lecture Mobile Phase Selection in Partition Chromatography Optimization of the mobile phase composition and polarity is vital for obtaining.
1 1. Introduction H: High P : Performance (Pressure) L : Liquid C : Chromatography GC : Gas chromatography TLC: Thin layer chromatography IC : Ion chromatography.
Ion-Pair Chromatography In addition to the aqueous buffer and an organic solvent that is typical for reversed-phase, the mobile phase contains a counter.
Standard Methods for the Examination of Water and Wastewater, 21st Ed
Chromatography.
Chem. 31 – 4/8 Lecture. Announcements I Exam 2 – Monday –Covering Ch. 6 (topics since exam 1), 7, 8-1, 17, and parts of 22 (up to and including retention.
Using Chromatography to Select Effective Biomineral Growth Modifiers Tissa J. Thomas and Ryan E. Sours Department of Chemistry, Towson University, Towson,
Amino Acid Analyzer Nashwa Othman.
 Amino acid analysis refers to the methodology used to determine the amino acid composition or content of proteins, peptides, and other pharmaceutical.
Chromatography and Instrumentation. Invented by a Russian Botanist Mikhail Tswett in 1903 He used chromatography to separate the colour pigments in plants.
Separation of proteins by ion exchange chromatography
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Chapter 6 - Chromatography
High Performance Liquid Chromatography
Chromatography Chapter 6.
Magnet Analytical Chemistry Unit 4
Intro to Chromatography
GC Advantages 1. Very Large N (Very Long Columns) 2. No Packing Material (A=0) 3. Simple Mobile Phase (Compressed Gas) 4. Universal Detectors (FID) 5.
ERT106 BIOCHEMISTRY PROTEIN TECHNOLOGY By Pn Syazni Zainul kamal.
Ion exchange chromatography
Aquious Halide Concentration Determination via Leucigenin Quenching and Indirect CE Christopher Hampton, Dr. Eamonn F. Healy, Chemistry Department, St.
Proteins separation and analysis using Fast Protein Liquid Chromatography Ayelet David, Ph.D Dept. of Clinical Pharmacology.
 Biomolecules are purified using purification techniques that separate according to differences in specific properties.
AFFINITY CHROMATOGRAPHY Presented By: Salma Al-Salman
Paper and Thin Layer Chromatography (TLC) Experiment 6 BCH 333 [practical]
8 Protein Interactions with Biomaterials CHAPTER
Affinity Chromatography
By- Bhavya, Harsh, Harshvardhan, Namrata, Ronit and Vidhatri
HPLC – High Performance Liquid Chromatography
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
Introduction to Chromatography. Introduction Chromatography permit the scientist to separate closely related components of complex mixtures. In all chromatographic.
The Chromatogram  Terms:  Retention time  Peak area  Peak width (at half height, at base)  Peak height  Void time/volume  Adjusted retention time.
Best Broken into four categories
Chromatography High Performance Liquid Chromatography HPLC Chapter Dr Gihan Gawish.
HPLC.
Adsorption Chromatography 1Dr. Nikhat Siddiqi. Adsorption chromatography refers to the use of a stationary phase or support such an ion-exchange resin,
Biochemical instrumental analysis - 11 Dr. Maha Al-Sedik 2015 CLS 332.
AMINO ACIDS PTT 202: ORGANIC CHEMISTRY FOR BIOTECHNOLOGY PREPARED BY:
HPLC.
Chromatography and Instrumentation. Chromatography Separate Analyze Identify Purify Quantify Components Mixture Chromatography is used by scientists to:
Introduction to Instrumental Analysis - Chromatography
HPLC 1. Introduction 1.Introduction  INSTUMENTAL ANALYSIS  PRACTICAL 213 PHC  HPLC.
Lecture 8 Peak Parameters and Quantitative chromatography
Biochemical Reactions Chapter 1.3 McGraw-Hill Ryerson Biology 12 (2011)
Chapter 1: The Nature of Analytical Chemistry
Instrumental Analysis (I) HPLC Tutorial 8. Graded presentation Students in groups of 4-5 individuals are asked to prepare a presentation (weight=5% of.
Instrumental Analysis (I)  HPLC Tutorial #7 PHCMt561 – 5 th Sem. Pharm.
Purification of immunoglubin by ion exchange chromatography Bahiya Osrah
Principles of chromatography
Tymoczko • Berg • Stryer © 2015 W. H. Freeman and Company
Chromatography.
High Performance Liquid Chromatography. What is HPLC ? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Purification Of Proteins.
Chromatography- TLC & HPLC
CHROMATOGRAPHY.
Chem. 31 – 11/1 Lecture.
HPLC.
High Performance Liquid Chromatography (HPLC)
Chromatographic separation
Affinity chromatography
HPLC.
Volume 95, Issue 2, Pages (October 1998)
M.S COLLEGE OF ARTS, SCIENCE, COMMERCE AND B.M.S
High performance liquid chromatography (HPLC)
Presentation transcript:

Paul Hagey, Eamonn F. Healy, St. Edward’s University, Development of a Quantitative Assay for Glutathione Reductase Paul Hagey, Eamonn F. Healy, Chemistry Department, St. Edward’s University, Austin TX 78704

Abstract Glutathione Reductase has been implicated as the critical enzyme for maintenance of GSH during oxidative stress. We report here steps towards development of quantitative assay for Glutathione Reductase using biotin. Biotinylation has achieved widespread and general utility in a variety of bioanalytical applications due to the ready formation of biotin-avidin complexes (1015 M-1). We have succeeded in coupling a biotin to GSSG (reduced glutathione), with detection by HPLC at 260nm. The GSSG-biotin is then complexed with Glutathione Reductase, and subsequently complexed in a Glutathione Reductase :GSSG-biotin : avidin triplex. By purifying the resulting complex and spectroscopically determining the concentration, Glutathione Reductase can be accurately assayed.

Glutathione Reductase Glutathione reductase (GR, EC 1.6.4.2) is an ubiquitous enzyme which catalyzes the reduction of oxidized glutathione (GSSG) to glutathione (GSH). Glutathione reductase is essential for the glutathione redox cycle that maintains adequate levels of reduced cellular GSH. GSH serves as an antioxidant, reacting with free radicals and organic peroxides, in amino acid transport, and as a substrate for the glutathione peroxidases and glutathione S-transferases in the detoxification of organic peroxides and metabolism of xenobiotics, respectively

Role of Glutathione

Biotinylated Probes Biotin (B) is a small molecule that covalently attaches to selected residues of bioactive peptides and proteins , termed probes (P), without causing loss of function Biotin is useful because its high affinity for avidin (Av) and streptavidin allows the biotin-peptide complex to form a triplex (Av:B-P) with the protein, thus isolating the probe By incubating this triplex with the probe’s natural target molecule (T) a complex of composition Av:B-P:T is now isolated An assay of the avidin present is now also a quantitative assay the target protein

Project Our first requirement was to identify the particular form of biotin (B) suitable for attachment to our GSSG peptide. We have achieved success with a NHS-ester derivative with a 6-C spacer arm, shown on the right. After developing a suitable HPLC separation method we are currently focusing on using preparative HPLC to isolate the purified B-GSSG probe. After suitable characterization we will proceed to form a triplex (Av:B-GSSG) of a out biotinylated probe with Avidin Finally we hope to form our GRase:GSSG-B:Av complex

HPLC HPLC instrumentation includes a pump, injector, column, detector and recorder or data system, connected as shownon the right. The heart of the system is the column where separation occurs. The chromatographic process begins by injecting the solute onto the top of the column.Separation of components occurs as the analytes and mobile phase are pumped through the column. Eventually, each component elutes from the column as a narrow band (or peak) on the recorder. Analyte molecules, while moving through the porous packing bead, tend to interact with the surface adsorption sites. All these interactions are competitive. Analyte molecules are competing with the eluent molecules for the adsorption sites. So, the stronger analyte molecules interact with the surface, and the weaker the eluent interaction, the longer analyte will be retained on the surface.

UV-Vis Absorbance of GSSG

Biotinylation Methodology The probe to be biotinylated is dissolved in a phosphate, pH=7.6 buffer at a concentration of 10mg/mL The biotinylation reagent is dissolved in dimethylformamide at a concentration of 25mg/mL, and stored as a stock solution at 2-8 oC (stable for approx. 24 hrs) The biotinylation reagent is added slowly to the probe solution in a 10-30 molar excess and gently mixed for 1-4 hours The reaction is terminated by adding 1mL of 20% TFA The products are analyzed using reverse phase HPLC and a C-18 column

Results GSSG Biotin Time :1 hour Time : 1hour Phosphate pH=7.6 Solvent A: ACN Solvent B: ACN/1%TFA Detector : 260nm Flow Rate : 1ml / min Biotin Time : 1hour Phosphate pH=7.6 Solvent A: ACN Solvent B: ACN/1%TFA Detector : 260nm Flow Rate : 1ml / min

Results GSSG / Biotin Time : 1 day GSSG / Biotin Time : 4 days Phosphate pH=7.6 Solvent A: ACN Solvent B: ACN/1%TFA Detector : 260nm Flow Rate : 1ml / min GSSG / Biotin Time : 4 days Phosphate pH=7.6 Solvent A: ACN Solvent B: ACN/1%TFA Detector : 260nm Flow Rate : 1ml / min

Results Lys-Tyr-Lys / Biotin Time :initial Lys-Tyr-Lys / Biotin Phosphate pH=7.6 Solvent A: ACN Solvent B: ACN/1%TFA Detector : 260nm Flow Rate : 1ml / min Lys-Tyr-Lys / Biotin Time : 1 day Phosphate pH=7.6 Solvent A: ACN Solvent B: ACN/1%TFA Detector : 260nm Flow Rate : 1ml / min

Discussion The peak at 7.6 min on the chromatogram of the GSSG / NHS-spacer-biotin indicates to use the successful biotinylation of our peptide probe. However definitive characterization will require purification using a semi-preparative C-18 column and analysis by mass spectroscopy. As a preliminary check we biotinylated a Lys-Tyr-Lys tripeptide, similar in size to GSH, and found a peak at a retention time of 8.1 mins. Since biotin is known to attach easily to the e-amino group of a lysine residue this result does seem to support our hopes of a successful biotinylation of GSSG. It remains to bee seen whether this 7.6 min peak represents a mono-or di-biotinylated adduct. Upon purification of the B-GSSG complex we intend to incubate it with avidin horseradish peroxidase(AvHpr), an avidin derivative capable of simple and quantitative assay Final formation of our Grase:GSSG-B:AvHpr complex will then allow a quick, colorimetric, quantitive assay of Glutathione Reductase

References Acknowledgements Brian T. Miller, et al.;Peptide Biotinylation with Amine-Reactive Esters;Peptides. 1997, 18, 1586 Acknowledgements We gratefully acknowledge the support of the Welch Foundation in the form of a Departmental Research Grant