DOM Two Dimensional Scanning using testDAQ Hiroko Miyamoto T. Noda Faculty of Science Department of Physics Chiba University.

Slides:



Advertisements
Similar presentations
PMT Calibration Results and the MC simulation Shigeru Yoshida, Chiba University
Advertisements

Prototype of the Daya Bay Neutrino Detector Wang Zhimin IHEP, Daya Bay.
CRAYS and TA telescope calibration ICRR N. Sakurai, M. Fukushima Utah University L. Wiencke.
Uniformity Measurement of the Hamamatsu 10 inch PMT Hiroko Miyamoto Dept. of Physics CHIBA University Laguna Beach2003.
KEK beam test H. Sakamoto. Purpose To optimize a concentration of the second dopant for scintillating fibers KEK beam test to study light yields for various.
Basic Measurement of the Hamamatsu 10 inch PMT at –40 degree –40 degree Hiroko Miyamoto Dept. of Physics CHIBA University Angular Response of 10inch PMT.
The result of GoldenDOM Calibration Hiroko Miyamoto T.Noda, S.Yoshida, K.Mase K.Hoshina, M.Krasberg, K.Hanson, C.Rott Chiba University, UW Madison, PSU.
A first look of the 10” High QE PMT Shigeru Yoshida for Yuusuke Hasegawa and Mina Inaba Dep. of Physics, Chiba University “Super Bialkali” photocathode.
PMT absolute calibration using the Rayleigh scattering in Nitrogen air PMT absolute calibration using the Rayleigh scattering in Nitrogen air ICRR N.Sakurai,
Angular Response of 10inch PMT for IceCube Hiroko Miyamoto Dept. of Physics Chiba University.
PMT SPE Chiba (new parameters for next version of ROMEO) (new parameters for next version of ROMEO) Yusuke Hasegawa et al., presented by.
Calibration of the 10inch PMT for IceCube Experiment 03UM1106 Kazuhiro Fujimoto A thesis submitted in partial fulfillment of the requirements of the degree.
BLM review Mario Santana Leitner OUTLOOK ON FLUKA SIMULATIONS FOR UDULATOR DAMAGE AND BLM RESPONSE Mario Santana Leitner, Alberto.
Time over Threshold Electronics for Neutrino Telescopy George Bourlis + multiplicity.
Eusoballoon optics characterisation Camille Catalano and the Toulouse team Test configuration Calibration of the beam Exploration of the focal plan.
Special Issues on Neutrino Telescopy Apostolos G. Tsirigotis Hellenic Open University School of Science & Technology Particle and Astroparticle Physics.
Measurement of the absolute efficiency,
PD Kobe Univ. 06/29/2007 General performance of the IceCube detector and the calibration results I am Mina Inaba from Chiba university. I will.
6 April 2006, LGStatus Report Beam Working Group1 Beam Working Group Status Report 6 April 2006 Presented by Lau Gatignon  Cedar status  MNP33-2  Outgassing.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Catania VLVnT09 Athens, Greece 1/14 Catania Performances of four super bialkali large area photomultipliers with respect to.
Leroy Nicolas, HESS Calibration results, 28 th ICRC Tsukuba Japan, August Calibration results of the first two H·E·S·S· telescopes Nicolas Leroy.
Coincidence analysis in ANTARES: Potassium-40 and muons  Brief overview of ANTARES experiment  Potassium-40 calibration technique  Adjacent floor coincidences.
IceTop Tank Calibration Abstract This report outlines the preliminary method developed to calibrate IceTop tanks using through going single muon signals.
K1.8 meeting Report from E05 group Toshiyuki Gogami 26 Dec 2014.
1 System Description (2-4) Gains from single photo-electrons in vacuum at room temperature (5-8) Linearity Test at V in vacuum at room temperature.
Calibration of the calorimeter by punch-through muons and cosmic muons Doroshenko M. E391 collaboration.
Development of A Scintillation Simulation for Carleton EXO Project Rick Ueno Under supervision of Dr. Kevin Graham.
14/02/2007 Paolo Walter Cattaneo 1 1.Trigger analysis 2.Muon rate 3.Q distribution 4.Baseline 5.Pulse shape 6.Z measurement 7.Att measurement OUTLINE.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Position Reconstruction in Miniature Detector Using a Multilayer Perceptron By Adam Levine.
Special Issues on Neutrino Telescopy Apostolos G. Tsirigotis Hellenic Open University School of Science & Technology Particle and Astroparticle Physics.
N 2 Laser 300  QQ 150m HF  HF + 9 PMT Boxes  QP Calib Box 1  4 Counting Room HF Calibration Optical Fiber Path 9 PMT Boxes / Quad 24 PMT Tubes.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
Calibration of the new Particle Identification Detector (PID) Tom Jude, Derek Glazier, Dan Watts.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH.
1 Report on analysis of PoGO Beam Test at Spring-8 Tsunefumi Mizuno July 15, 2003 July 21, 2003 revised August 1, 2003 updated.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
NESTOR SIMULATION TOOLS AND METHODS Antonis Leisos Hellenic Open University Vlvnt Workhop.
Nov Beam Catcher in KOPIO (H. Mikata Kaon mini worksyop1 Beam Catcher in the KOPIO experiment Hideki Morii (Kyoto Univ.) for the KOPIO.
PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis.
MPPC status M.Taguchi(kyoto) T2K ND /7/7.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
Design for Wide FOV Cherenkov telescope upgrading THE 2 nd WORKSHOP OF IHEP Shoushan Zhang Institute of High Energy Physics.
Catania 11 ICATPP october, 2009 Como 1/12 Catania Comparative measurements of the performances of four super bialkali large.
G. Tzanakos, MINERvA Collaboration Meeting, Jan 14, Goal: Build a Test Stand that can test and characterize 10 PMTs. Assumptions about MINERvA Electronics:
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
Multipixel Geiger mode photo-sensors (MRS APD’s) Yury Kudenko ISS meeting, KEK, 25 January 2006 INR, Moscow.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
F Don Lincoln, Fermilab f Fermilab/Boeing Test Results for HiSTE-VI Don Lincoln Fermi National Accelerator Laboratory.
PMT measurements in Antares Oleg Kalekin on behalf of Antares collaboration VLVnT 2011 Erlangen
Current status of XMASS experiment 11 th International Workshop on Low Temperature Detectors (LTD-11) Takeda Hall, University of Tokyo, JAPAN 8/1, 2005.
Performance of new MPPC Nov. 21 Korea-Japan joint meeting Takashi Maeda Hideki Yamazaki Yuji Sudo (University of Tsukuba) --- Contents ---
Basic Measurement of the Hamamatsu 10 inch PMT at –40 degree –40 degree Hiroko Miyamoto Dept. of Physics CHIBA University The Uniformity measurement of.
MEG 実験 2009 液体キセノン検出器の性能 II 西村康宏, 他 MEG コラボレーション 東京大学素粒子物理国際研究セン ター 第 65 回年次大会 岡山大学.
P HOTON Y IELD DUE TO S CINTILLATION IN CF4 Bob Azmoun, Craig Woody ( BNL ) Nikolai Smirnov ( Yale University )
1 Report on analysis of PoGO Beam Test at Spring-8 Tsunefumi Mizuno July 15, 2003 July 21, 2003 revised.
Limitations on the Design of the CEDAR Light-guide Calculations of the light-collection efficiency indicate a severe limitation in the possible collection.
The photomultiplier tubes selection for KM2A electromagnetic particle detectors (EDs) hou chao IHEP The 2nd workshop of air shower detection at high altitudes.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
KM2A PMT testing platform FENG Cunfeng, LI Chaoju, SUN Yansheng Shandong University THE 2 nd WORKSHOP OF AIR SHOWER DETECTION AT HIGH ALTITUDES IHEP, Beijing,
1 PMT Univ. of Tokyo Yasuko HISAMATSU ICEPP, MEG Collaboration meeting Feb. 10th, 2004.
1 PMT Univ. of Tokyo Yasuko HISAMATSU ICEPP, The University of Tokyo MEG VRVS meeting Jan. 20th, 2004.
OD Tuning: SK-IV Roger Wendell TMC Meeting
Development of Multi-Pixel Photon Counters (1)
Fabio, Francesco, Francesco and Nicola INFN and University Bari
Department of Physics and Astronomy,
MEG II実験 液体キセノン検出器の建設状況
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

DOM Two Dimensional Scanning using testDAQ Hiroko Miyamoto T. Noda Faculty of Science Department of Physics Chiba University

Reminder: We did 2D scan for bare PMTs CE uniformity : Some tube to tube differences Gain uniformity: Almost universal behavior Implemented by ROMEO

New: 2D scan for DOMs CE uniformity / Gain uniformity: Present: Rely on Geant4 MC + the bare PMT calibration data to predict DOM acceptance. The complex structure of DOM has not been implemented in the MC. Easier and more reliable to MEASURE it directly!

2D Scanning System for DOM Harness wire

DOM 2D Scanning System

Setup Light Source: NICHA 375nm UV-LED PEs / shot, fired 1.6kHz by pulser 2D scanning system Spot size: ~1cm with the collimator Scan 4  in ~5cm intervals from point to point Do “testDAQ” ( ‘ready’ and ’go’) at each point. DOM Virgo, Rev4 Unsealed DOM, room temperature, ~1atm TestDAQ : taking data with ~4PE threshold, 1e+07Gain

Analysis Method (preliminary) (using the java program written by Chris W.) Calculate the photoelectron number with domcal Calibration (J.Braun?). Use the average of ~3,000 samples for each point of the DOM surface.

Results (preliminary…) Harness top center Harness top center

Results (preliminary…) Harness top center

Results (preliminary…) top center ~25cm Harness Forward region Backward region Backward region

Results (preliminary…) Harness top center

Results (preliminary…) top center Harness

Results (preliminary…) top center Harness ~25cm

Results (preliminary…)

Summary (Preliminary…) Took a first data of DOM photon CE map (along 1 axis). “effective” diameter of photon detection area is approximately 25 cm, which is consistent with the PMT cathode area we had measured previously. Photons hitting from backside of DOM do not produce measurable signals. To map out this region, we must improve our triggering : currently internal trigger with 4 PE threshold.

Issues to be resolved It would be better to trigger DOM EXTERNALY for taking non-biased data – Internal trigger with 4PE threshold may cause bias in scanning backside of DOM sphere. Domcal charge estimation may contain some errors in the estimation of the total charge (photoelectron #) of each channels. Need to figure out a way to turn off and on data taking without recycling HV power.

Outlook 4  measurement and map the CE on the whole DOM surface to be implemented by the detector MC simulation. Produce the standard-EYE DOM scanned by this method.

Near future plan Absolute calibration of DOM by scattered light from N2 laser : We did for bare PMTs It would be nicer if external trigger available