The development of SDHCAL in Mokka Gabriel Musat, Ran Han, Gerald Grenie 2011-01-05.

Slides:



Advertisements
Similar presentations
01/07/2008HCAL Main Meeting- Mechanical Integration1 ILD HCAL Mechanical Integration HCAL Main Meeting Kirsten Kschioneck, DESY.
Advertisements

1 Calice LCUK Bristol 24/03/09 David Ward WP1 : Test Beam.
Mechanical Status of ECAL Marc Anduze – 30/10/06.
A preliminary analysis of the CALICE test beam data Dhiman Chakraborty, NIU for the CALICE Collaboration LCWS07, Hamburg, Germany May 29 - June 3, 2007.
The first testing of the CERC and PCB Version II with cosmic rays Catherine Fry Imperial College London CALICE Meeting, CERN 28 th – 29 th June 2004 Prototype.
Simulation of the CALICE Test Beams with MOKKA Fabrizio Salvatore Royal Holloway University of London.
Simulation of the DHCAL Prototype Lei Xia Argonne National Laboratory American Linear Collider Workshop: Ithaca, NY, July , 2003 Fe absorber Glass.
8/17/031 Geant4 Simulations Guilherme Lima, Jeremy McCormick General Comments Test Stand (JM) Test Beam (GL)
Test Beam models in Mokka Fabrizio Salvatore (RHUL) Gabriel Musat (LLR) Paulo Mora de Freitas (LLR)
Inside the new Mokka release Fabrizio Salvatore (RHUL) Gabriel Musat (LLR) Paulo Mora de Freitas (LLR)
1/9/2003 UTA-GEM Simulation Report Venkatesh Kaushik 1 Simulation Study of Digital Hadron Calorimeter Using GEM Venkatesh Kaushik* University of Texas.
Mokka and integration of the geometry AIDA kick-off meeting WP2 session: Common software tools 17 February 2011 – CERN Paulo Mora de Freitas and Gabriel.
ALCPG09 Albuquerque, The new geometry of the ILD muon system in MOKKA N. D’Ascenzo, V. Saveliev, Obninsk State University / DESY U. Schneekloth.
ILD ILD Simulation Status and Plan Akiya Miyamoto for ILD Software group 27-March-2010, Beijing LCWS2010.
Development of Particle Flow Calorimetry José Repond Argonne National Laboratory DPF meeting, Providence, RI August 8 – 13, 2011.
RPC detection rate capability ≈ 1/ρ Float-Glass ( Ω-cm) RPC rate capability < Bakelite( Ω-cm) one. New kind of doped glass was developed.
International Workshop on Linear Colliders, Geneve Muon reconstruction and identification in the ILD detector N. D’Ascenzo, V.Saveliev.
Oct. 22, G.Lima1 Delving Deeper into Geant4 Guilherme Lima DHCal Meeting October 22, 2003.
M. Chefdeville LAPP, Annecy, France. Introduction  Motivations for a Digital hadronic calorimeter Count hits instead of measuring energy deposits Reduce.
V.Dzhordzhadze1 Nosecone Calorimeter Simulation Vasily Dzhordzhadze University of Tennessee Muon Physics and Forward Upgrades Workshop Santa Fe, June 22,
UTA GEM DHCAL Simulation Jae Yu * UTA DoE Site Visit Nov. 13, 2003 (*On behalf of the UTA team; A. Brandt, K. De, S. Habib, V. Kaushik, J. Li, M. Sosebee,
Gabriel Musat L.L.R. – Ecole polytechnique ECFA-DESY Linear Collider Workshop Amsterdam, April 1-4, 2003.
Towards a 1m 3 Glass RPC HCAL prototype with multi-threshold readout M. Vander Donckt for the CALICE - SDHCAL group.
Development of Digital Hadron Calorimeter Using GEM Shahnoor Habib For HEP Group, UT Arlington Oct. 12, 2002 TSAPS Fall ’02, UT Brownsville Simulation.
1ECFA/Vienna 16/11/05D.R. Ward David Ward Compare these test beam data with Geant4 and Geant3 Monte Carlos. CALICE has tested an (incomplete) prototype.
RPC Design Studies Gabriel Stoicea, NIPNE-HH, Bucharest CBM Software Week GSI-Darmstadt May 10, 2004.
Marcel Stanitzki 1 More results... SiD PFA Meeting M. Stanitzki.
Simulation of the CALICE Test Beams with MOKKA Fabrizio Salvatore Royal Holloway University of London.
Plans for a Simulation Study of the Magnetic Field Requirements of the LC TPC February 2006, ILC TPC Analysis Jamboree, DESY Christian Hansen University.
ILC Calorimetry Test Beam Status Lei Xia ANL HEP.
1 ILD meeting LAL M. Joré – Integration status Matthieu Joré – 25 th of May ILD integration status and open issues.
J-C Brient-DESY meeting -Jan/ The 2 detector options today …. SiD vs TDR [ * ] [ * ] J.Jaros at ALCPG-SLAC04 ECAL ECAL tungsten-silicon both optionsHCAL.
Geant4 CPU performance : an update Geant4 Technical Forum, CERN, 07 November 2007 J.Apostolakis, G.Cooperman, G.Cosmo, V.Ivanchenko, I.Mclaren, T.Nikitina,
Mokka, main guidelines and future P. Mora de Freitas Laboratoire Leprince-Ringuet Ecole polytechnique - France Linear collider Workshop 2004, Paris.
FCC-hh HCAL software goals Ana Henriques (thanks for Clement Helsens, Carlos Solans input)
Update on pion and muon showers Erik van der Kraaij & Przemyslaw Majewski CERN LCD May 17, 2010.
Longitudinal shower profile - CERN electron runs Valeria Bartsch University College London.
The Prototype Simulation of SDHCAL Ran.Han Gerald.Grenier Muriel.Donckt IPNL.
Imaging Hadron Calorimeters for Future Lepton Colliders José Repond Argonne National Laboratory 13 th Vienna Conference on Instrumentation Vienna University.
Redesign of LumiCal mechanical structure W.Daniluk, E.Kielar, J.Kotula, K.Oliwa, Wojciech Wierba, L.Zawiejski Institute of Nuclear Physics PAN Cracow,
DHCAL Jan Blaha R&D is in framework of the CALICE collaboration CLIC08 Workshop CERN, 14 – 17 October 2008.
MOKKA - recent developments Gabriel Musat, L.L.R. – Ecole Polytechnique.
Future DHCAL Activities José Repond Argonne National Laboratory CALICE Meeting, CERN, May 19 – 21, 2011.
Energy Reconstruction in the CALICE Fe-AHCal in Analog and Digital Mode Fe-AHCal testbeam CERN 2007 Coralie Neubüser CALICE Collaboration meeting Argonne,
SDHCAL. outline  SDHCAL concept, validation and construction  Test Beam and technological prototype performance  Perspectives and Conclusion  SDHCAL.
The ILD ECAL Jan th Paris Satoru Uozumi (Kyungpook Natl. Univ.) for the ILD ECAL group Contents :
ILD software pre-meeting, LAL, Orsay, May 22 nd 2011 p1p1 SDHCAL software status Gérald Grenier IPN Lyon, Université Lyon 1 ILD Software pre-meeting, LAL,
14.4. Readout systems for innovative calorimeters
Test Beam Request for the Semi-Digital Hadronic Calorimeter
Dead zone analysis of ECAL barrel modules under static and dynamic loads Marc Anduze, Thomas Pierre Emile – LLR CALICE Collaboration Meeting.
HCAL preliminary analysis and results
CEPC 数字强子量能器读出电子学预研进展
A proposal to equip the high eta muon stations with High Rate GRPC
Geant4-based Simulation Status and Plans
Calorimeter Geometry in Mokka
The Simulation Status of SDHCAL
Dead zone analysis of ECAL barrel modules under static and dynamic loads for ILD Thomas PIERRE-EMILE, Marc ANDUZE– LLR.
(My personal) CALICE Report
Tao Hu, Jianbei Liu, Haijun Yang, Boxiang Yu For the CEPC-Calo Group
Sub-Detector Assembly Area Summary of discussion at ALCW2015
Studies with PandoraPFA
State-of-the-art in Hadronic Calorimetry for the Lepton Collider
Gabriel Musat L.L.R. – Ecole polytechnique
GEM-based Digital Hadron Calorimetry for SiD
GEM-based Digital Hadron Calorimetry for SiD
Outline of CEPC Calorimeters CDR
Status of CEPC HCAL Optimization Study in Simulation LIU Bing On behalf the CEPC Calorimeter working group.
Gabriel Palacios 09/04/18 Tests for Joe Gabriel Palacios 09/04/18.
Test Beam models in Mokka
Simulation Tools for CepC Detector
Presentation transcript:

The development of SDHCAL in Mokka Gabriel Musat, Ran Han, Gerald Grenie

Outline The structure of Videau and Tesla How to use Test with geantino and Marlin-Pandora

Two SDHcal Mode in Mokka Tesla SHcalRPC02: Keep AHCal information added SDHCal in Videau Drive: ~/Mokka/source/ Geometry/LDC/SH calRPC01

The Changes in Videau The usage is the same as before, already sumbit to Mokka Radius=4mm, Distance=10cm, Material=Nylon. should be GlassfiberGraphit_thinkess_ Some more details: Cathode: from 0.1 to 0.05mm, Mylar_thinkness_Cathode: from 0.20mm to 0.18mm Chip_Package from 1.4mm to 1.6mm PCB_Thinkness from 0.8mm to 1.2mm

The implantation to AHCAL --TESLA each staves divided in two halves in the x,y plane octahedral structure along the Z-axis, the calorimeter is again divided in two modules, with a gap of 2mm. eight identical staves

The Stave in Tesla BarrelHalfRegularChamberTrap: Build the chamber BarrelChambersSupportTrap: Build layer Support structure 5mm BarrelModuleGap: simulated the gaps Between two real halves BarrelChambersGap: Build the gap between chambers and layer support

The chambers BarrelHalfRegularChamberTrap Rotate in Y direction The thicknes of Scintilator is 4.3 mm The thickness of RPC kept 6.5mm(include Electrics) The 20mm stellabsorber is the same

The size of Hcal with sci and rpc Hcal_inner_radius=Ecal_outer_radius=Same Hcal_outer_radius= Hcal_inner_radius+Hcal_total_dim_y= different SDHCAL Hcal_total_dim_y=1287 Hcal_outer_radius = 3227 AHCAL Hcal_total_dim_y= Hcal_outer_radius = = = ( )*48

How to use Tesla Model 1: Mokka checkout svn co kka/trunk Mokka 2: Mokka Compile cd ~/Mokka/source make 3:Mokka Run Mokka init.macro The file in init.macro like /Mokka/init/detectorModel ILD_01pre00 /Mokka/init/EditGeometry/rmSubDetector SHcalSc03 /Mokka/init/EditGeometry/addSubDetector SHcalRpc #/Mokka/init/globalModelParameter Hcal_sensitive_model scintillator /Mokka/init/globalModelParameter Hcal_sensitive_model SDRPC /Mokka/init/globalModelParameter Hcal_cells_size 10 /Mokka/init/initialMacroFile mac.mac /Mokka/init/lcioFilename pi80GeV-100O- 80deg.slcio /Mokka/init/MokkaGearFileName pi80GeV- 100O-80deg.xml Gerald ‘s script for Mokka, svn: /analyse/trunk/SDHCAL-offline-tools/run_Mokka_gridSite.sh Change Mokka version to your own

Use geantino to do test e e e e+03 BarrelHcalModule Transportation e e e+03 physiRPCFree Transportation e e e+03 physiRPCmylarCathode Transportation e e e+03 physiRPCGraphiteCathode Transportation e e e+03 physiRPCThickGlass Transportation e e e+03 physiRPCGap Transportation e e e+03 physiRPCThinGlass Transportation e e e+03 physiRPCGraphiteAnode Transportation e e e+03 physiRPCmylar Transportation e e e+03 physiRPCPCB Transportation e e e+03 physiRPCElectronics Transportation e e e+03 BarrelHcalModule Transportation e e e e+03 BarrelHcalModule Transportation e e e+03 SteelCassette Transportation e e e+03 Scintillator Transportation e e e+03 PCB Transportation e e e+03 Cu Transportation e e e+03 BarrelHcalModule Transportation

Test in Marlin-Pandora process Two issues exist: 1: If chose RPC model, the GEAR file for HCAL not complete, need to add HCAL information to GEAR file by hand(next step) 2: for ILD_01pre00 mode, default for Ecal is Silicon? For some events there is problem like “[ ERROR "MySiliconTracking"] SiliconTracking => fatal error in FTD : layer is outside allowed range : 71” Ecal problem or Our Gear file Problem?

Next step 1; drive SHcalRPC01 (Viedau model) did do any test yet, mainly to see spacers. 2; drive SHcalRPC02: no pad seperation for this moment 3; not yet submit the new SHcalRPC02 to Mokka official yet