Mercantil Laboratorio SAC Calle Santorin N° 243 Urb. El Vivero Monterrico Surco - Lima 33 Telef. 4342727 Fax 4360138

Slides:



Advertisements
Similar presentations
ISO-8655:2002.
Advertisements

Improving Pipetting Techniques For better accuracy and performance
Measuring Volume Biotech I pg. 301 to 323 in Basic Laboratory Methods.
บริษัทหริกุล ซายเอนซ์ จำกัด
Corbett Research CAS-1200 Dimensions Operates from PC or laptop
Use and Maintenance of Micro-pipettes
Measuring Small Amounts Part 1: Using pipets and micropipets.
Information Session Organisational Health – February 2013: V1
Titration By Dr H W Winter.
Rocket Investigation D. Crowley, Rocket Investigation Your task is to investigate what affects the maximum altitude a water rocket can reach As.
Oct. 22, 2012 Generosity Ludicrous: causing or deserving laughter because of absurdity Do Now: What is a microliter? How many microliter are in one liter?
Lab safety No food, backpacks in lab No open-toed shoes Goggles Make sure you know the location of safety equipment Buddy system.
What are Micropipettors?! We will be using 3 different sizes of micropipettors: ◦ P20 ◦ P200 ◦ P1000 Very expensive and very fragile – USE Responsibly!!!
Bellwork What is an SOP? What is its purpose?
Guide to Pipetting Pipette terms: Adjustment - altering the pipette so that the dispensed volume is within the specifications. Air Displacement Pipettes.
Use and Functional Verification of Automatic and Micro-Pipettes Module 7: Quality Assurance of Analytical Phase.
Materials Management BUS 3 – 141 Quality and Specification Leveraging Technical Excellence Week of Aug 31, 2010.
Pipette Calibration Procedure Pipette, water and balance Test the maximum volume or minimum volume Pre-wet tips Test 5 volumes per setting.
Gage Blocks.
Partnering & Strategic Alliances
Measuring volumes which are what we scientists call “very, very small”
Physical Properties: Melting Temperature Boiling Temperature Color
Module 11: Use and Care of Equipment At the HIV Rapid Testing Site.
Measuring Accurately Learning to use equipment for liquids.
Lab Bot 800 Dual Arm Fully Automated Liquid Handling Workstation.
Biochemistry Practical Dept.of Biochemistry Zhihong Li ( 李志红 )
Gage Blocks Unit 12.
© 2007 Wiley Chapter 3 - Product Design & Process Selection.
Metrology Adapted from Introduction to Metrology from the Madison Area Technical College, Biotechnology Project (Lisa Seidman)
EVol ® Introducing the Worlds First Digitally-Controlled Analytical Syringe Everyone an Expert.
MEASUREMENT OF VOLUME. OVERVIEW First some general principles Then, more detail about micropipettes.
Flex Cam – Training This shows one version of a complete FlexCam system including Power Unit HCP and Compact Cam CC for piercing operation.
(glass pipette, centrifuge, spectrophotometry)
Mastering the micropipette. What is a micropipette? How do you use a micropipette? How can I determine if I’m pipetting correctly?
MATRIX series.
Experiment 1 Basic Laboratory Techniques Parts A, D, E, and an Unknown
Uncertainty & Errors in Measurement. Waterfall by M.C. Escher.
Automatic pipettes use and calibration
Make a difference… … made with the outmost consideration for people and the environment Capp ecopipette TM Product Presentation.
Uncertainty & Errors in Measurement. Waterfall by M.C. Escher.
Biotech 8/20/13 What pump would you use for a 1 or 2 ml pipet? What pump would you use for a 5 or 10 ml pipet?
Visit us at E mail: Tele:
Proper Micropipette Technique and Slide Preparation
Control and signalling Harmony Easy XA2E Ø 22 mm, plastic push-buttons, switches with metallic-look ring Introducing the Easy line Essential automation.
Use and Maintenance of Micro-pipettes
Bangladesh BEST Programme
Accumax = Micropipettes.
Accumax = Micropipettes.
Introduction to Lab Techniques Measurements and Calibration.
Make a difference… … made with the outmost consideration for people and the environment Capp ecopipette TM Product Presentation.
Animals Including Humans
Automatic Pipettes Use And Calibration
Fundamental Techniques and Measurements
Techniques in Molecular Biology 2017 Fall Lecture -2-
READING MEASUREMENT SCALE INSTRUMENTS
Measuring Volume.
Techniques in Molecular Biology 2017 Fall Lecture -2-
Measurement of Volume Chapter 20.
Animals Including Humans
Metric System and Lab Skills
Use and Maintenance of Micro-pipettes
Chapter 8: Selecting an appropriate price level
Introduction To Medical Technology
Risk Management with Minimum Weight
Measuring volumes which are what we scientists call “very, very small”
Micropipettes.
Pipette Technique.
Grade Level: Middle School
Experiment 1 Basic Laboratory Techniques Parts A, D, E, and an Unknown
Pipette Calibration.
Presentation transcript:

Mercantil Laboratorio SAC Calle Santorin N° 243 Urb. El Vivero Monterrico Surco - Lima 33 Telef Fax

CappAero™ Pipettes Pipetting Concepts, Product Review and Selling Information Product training

Who are we?  Capp A/S is a Danish manufacturer of pipettes and immunowashers  Established 1984  World-wide distributor network of local laboratory suppliers and selective private brand agreements  An ISO 9001 Certificated Company

Where are we? Production and salesoffice worldwide: Capp A/S - Landbrugsvej 10 - DK-5260 Odense S - Denmark Tel Fax

Capp Profile Company vision  To develop, produce and market high quality pipettes and related equipment for liquid handling in laboratories. Strategic goal  To reach a globally strong position by means of a consistent and determined focus on a high quality profile.

Capp Profile Operating principles To develop products of the highest quality with emphasis on unique benefits to users. To be a serious trading partner conducting business with the highest degree of credibility.  To choose suppliers and subcontractors based on high quality, continuity, capacity and proximity and with emphasis on lasting, stable relationships.  To choose distributors with emphasis on long lasting, stable relationships based on trust and open two-way communication.  To promote and to increase the awareness of the pipetting concepts (the five elements of pipetting).

Pipetting General principles & background

Forward Pipetting The ”normal” pipetting technique  Push to 1 st stop  Draw up liquid  Dispense  Blow-out to 2 nd stop

Reverse Pipetting Useful e.g. for viscous samples  Push to 2 nd stop  Draw up liquid  Dispense to 1 st stop  Liquid may remain in tip!

Aspiration Techniques for correct aspiration:  Do not immerse too deeply  Keep the pipette vertical during aspiration!  Dip tip only a few mm into solution

Pipetting Guidelines Aspirate evenly and with consistent timing  Uneven rhythm/timing and/or piston movement: Up to 2% error (1.5% and 0.5% resp.) Immerse tip vertically to maximally 1 cm  Up to 1% error Keep pipettes, tips and liquid at same temp.  Up to 0.3% error/°C (RT to 0°C: 6%) % values of nominal volume

Pipetting Guidelines Prewet pipette tip before use  Up to 2% error  Also important for handling vapour pressure Wipe tip on vessel wall  Up to 3% error Do not reuse pipette tips  Up to 4% error % values of nominal volume

Pipetting Guidelines Choose correct pipette tips!  Up to 40% error!  Test: Fill tip, hold vertically – check for drops Specifications ONLY valid with CappExpel™  ISO , section 7.6: ”When using pipette tips not delivered by the pipette supplier, the supplier’s declaration or the certificate of conformity does not apply” % values of nominal volume

Accuracy Definition  ”Difference” between the set volume and observed mean volume: Example  CappAero™ 5-50  l :  1.5% (   l) at 5  l  0.7% (  0.35  l) at 50  l

Precision Definition  Reproducibility of a given volume delivered repeatedly. Given as coefficient of variance, Cv: Example  CappAero™ 5-50  l at 50  l:  0.3% (  0.15  l)

Determining Accuracy & Precision Control/register environmental cond.  Temperature (humidity and atm. Pressure) Use appropriate balance  4-6 places (depends on volume), calibrated. Carry out # weighings  Accuracy:  5; Precision: Calculate  Compensate for spec. density (temp.), evaporation.

Standards National / international  ISO 8655 is the guideline for piston-operated volumetric apparatus. Our products comply with essential requirements of Annex VIII of the IVDD (In vitro Diagnostics Directive 98/79/EC) and ISO :2002/ISO :2002. Capp has a Quality System in place based on DN/EN ISO 9001:2000.

The CappAero™ Pipettes Product description Features & benefits

CappAero Pipette Volumes Single channel  0.2-2; 05-10; 5-50; ; ; ul; 1-5 ml 8- and 12-channel  ; 5-50; ; ul 16-channel  0.2-2; ; 5-50 ul

CappAero Pipette Types Standard, Grey ColourLine, Single Standard, Transparent SoftLine

Main Feature / Benefit Groups  Ergonomics / User friendliness  Volume controllers  Tip handling  Pipetting performance  Robustness

Ergonomics and user friendliness Ergonomical design  Pipetting may result in strain in hand/arm and shoulder/neck regions  Capp design philosophy is based on minimising strain and risk of adverse effects (RSI)

Force requirements Relates to hand, wrist and arm problems Sum of 3 actions  Aspiration (to first stop)  Blow-out (to second stop)  Tip ejection (third stop or separate action) The lower, the better!

Force requirements

Force requirements 2

Work position – shoulder issues Shoulder most often raised  Need to keep pipette vertical  Pipette length Shorter pipette the only solution!  Standard pipette length:24-27 cm CappAero™ Short:19 cm First short pipette available!

Other friendly features Volume controller ”turns”  Accommodates right- and left-handed users Finger hook Allows relaxed hand and micro-pauses SoftLine hook is flexible – automatically adjusts to user’s finger!

Other friendly features Thumb positioned correctly  Position optimal when most force required SoftLine “rubber” handle Ultimately comfortable ColourLine Brings colour to your work! Even clearer identification of volume range

The CAPP volume controllers Switch variable  fixed volume  Quickest, most precise and easy  Fixed controllers calibrated at exact volume  Ideal for ”routine assays” Additional fixed volumes available  Any volume in range is possible  Also additional variable controllers (use as fixed?)

The CappAero volume controllers User friendly Always visible, not obscured by hand  Slider locks volume setting Economical  ”Two for one”  Very cheap compared to full fixed vol. pipette  Reduces down-time

The CappAero volume controllers Ordering volume controllers Variable volume:  xxx-VZ – where xxx = max volume of pipette Example: 200-VZ for µl pipettes Fixed volume:  xxx-FZ yy – xxx = max volume; yy = controller vol. Example: 200-FZ 50 – 50 µl controller for ul

Tip handling O-rings on all tip bases  (except the 16-channels)  Double o-rings is standard; single on 1000 ul pipettes Provides excellent sealing  Accommodates wider tip range Smaller contact area between pipette & tip  Significant reduction in ejection force

Pipette performance Precision/Accuracy  At least equal to competitors  Conforms to standards  Multi channel data equals single channel levels

Pipette Performance Temperature affects precision...  There is air between the pipette piston and the liquid in the tip  When the pipette is warmed by the hand, the air bubble also gets warmer and expands  The expanding air leaves less room for the liquid  the warmer the pipette gets, the less liquid is dispensed.

Pipette Performance The CappAero™ principle  When the knob is pressed down, warm air is expelled  When the knob goes back up, ambient temperature air is drawn into the pipette  ‚  The air in the hollow handle acts as insulation

CappAero™ Performance: Results

Robustness and reliability Steel, aluminium, polycarbonate...  Very high chemical resistance  Aluminium tolerates organic solvents better than plastic  Fully autoclavable  Much more break resistant

Robustness and reliability Tip bases easy to change  Individual tip bases can be changed on the multis Easy to service  Reduces need for (costly) external service  Minimal down-time

Capp in the market  Positioning  Competitor information

Market Positioning ?

Competitive Comparison

Competitive comparison FeatureCappAeroEpp. Refer.Epp. Res.Finn Digital Weight, g120 / Length, cm26 / Force required for...* Aspiration0++0 Blow-out Tip ejection0++0– to +* Setting, turns1018 Turn difficulty00 (2-handed)(+)+++ Finger rest+–++ * Depending on tip mounting pressure * 0  Capp level / +  Harder / –  Easier

Possible drawbacks Slightly heavier  Choice of steel and aluminium vs plastic  Work in progress to substitute materials to reduce weight – without compromising benefits Numbers in variable controller  Some find them small Detachable volume controllers  Risk getting lost in teaching labs...?

Possible drawbacks ”2 ul setting” on /  Made to reduce no. of turns  All pipettes can be locked in place “in between”  Competitors settings may be deceptive in precision

Selling the CappAero™ General selling points Tips & Tricks

General selling points Precision and accuracy  General argument  Know the data and definitions  Every pipette sells on this Capp also have  Ergonomically optimal design  Short pipette available  Simple and robust construction  Detachable volume controllers  Chemical resistance  Autoclavability Find the argument(s) that make your customer ”tick”

Hands-on selling The customer’s hands, that is...  ”It sells itself” (well, almost) Experience from other distributors  CappAero very well suited to small shows  Lots of points to talk about Use ”the look”!  ColourLine and SoftLine does well here!

Selling the singles Low force requirement  ”Plunger-to-plunger” demo  Look out for Gilson users ejecting the tip when aspirating Materials  Autoclavability  Break resistance Tip handling  vs Rainin LTS: same idea but with standard tips!

Selling the Short Show Universal & Short together  Point out ”they’re the same”  Hammer-and-Nail analogy Explain benefits  Shoulder relief  Enhanced tip control You’re better off vs competitors!  Labsystems introduced short pipette Nov ‘01

Multi channel selling Tip handling, tip handling and... tip handling!  ”Have you ever had trouble mounting and ejecting tips on your current multi channel pipette?”  ”How easy is it to mount the tips on your current multi?” Add the other benefits as necessary …

Multi channel selling Ejection lever for low-force ejection Tip bases  Aluminium – break resistant  Individually changeable Very easy maintenace  2 screws out gives full access to pistons Autoclavability Single-channel accuracy/precision data

Tips and tricks Tip base on the BZ ”pre-loosened” Use ColourLine for shows  More eye-catching! SoftLine may win customers  It just feels good (customer responses) Which hand does the customer use?  Controller-switch potential winner for left-handed users

Tips and tricks Demoing Multis:  Watch the screws! When you sell a Multi  ”Teach” the customer to mount tips  The tip bases are aligned!

Click to edit Master title style

Mercantil Laboratorio SAC Calle Santorin N° 243 Urb. El Vivero Monterrico Surco - Lima 33 Telef Fax