ERX-condensing units Strategic Marketing. 2 17-Dec-15 1.Concept 2.Product range 3.Combination table 4.Piping length 5.Control possibilities 6.Benefits.

Slides:



Advertisements
Similar presentations
VRV portfolio B15.
Advertisements

Daikin Altherma™ Troubling Shooting
Total HVAC Control from anywhere Easy control that can save a fortune
Setup/Installation/Operation of an Environmental Control Unit (ECU)
Student CD for Commercial Refrigeration for A/C Technicians
38GXC(Q)/40GXC(Q) Service Training Sizes 18 and 24K.
Copyright ⓒ 2008 All rights reserved LG Electronics Inc. Daikin VRV III vs LG MULTI V Plus II.
Engineer Presentation
Product Introduction.
Daikin Australia Pty. Limited Ducted Split Systems 2011.
VRV III Product Selection Piping selection
MDS Smart Commander.
Learning, our way Examples of bad installation. CONTENT Installation related examples Installation related examples Application related examples Application.
Perfect solution for large building
Air conditioning – Refreshes your life Mini-Chiller Applied Systems Sales1 EWA(Y)Q-AAV3P Residential Mini-Chiller Heating EWAQ - AA3VP EWYQ - AAV3P Cooling.
Air conditioning – Refreshes your life EWTP MBY Applied Systems Sales1 EWTP-MBYNN Air-cooled Heat Recovery.
TECHNICAL TRAINING INVERTER-Y
MDS Monitoring Software. Page 2 Contents  Introduction  User Interface  Service Personnel Interface  System Requirement  Demonstration.
EEV-KIT General Information. Preliminary information, all of contents are subject to final confirmation by MHI 2 Contents 1. What it EEV-KIT 2. What is.
Hydraulic Kit (pump and tank) Pictures from prototype.
Air conditioning – Refreshes your life Page 1 QA / PA Budget 2006 Product Portfolio Strategic Marketing DAIKIN EUROPE NV Presented by Linda Geeraerts ©
Flooded Screw Chiller FWSF Electronic Expansion Valve Condenser Evaporator Control box compressor Flooded Screw Chiller - FWSF.
For Multiple refrigeration system
EEV-KIT For Single refrigeration system. Preliminary information, all of contents are subject to final confirmation by MHI 2 Contents 1. Single refrigeration.
Principles of correct VRV Installation A. Refrigerant pipe work
Learning, our way Daikin Europe, Consulting sales section1 Understanding Client’s Needs and best Daikin solution.
Product Presentation 2007 SKY AIR Launch of new Non-Inverter + Duct (R22) series.
Page 1 LXMG , LXMG LXMG , LXMG PanelMatch™, StayLit™ Dual Lamp CCFL Inverter Modules Training.
© March 2008Environmental Stress Systems1 What you need to know when choosing a cascade condensing unit for your unique application Specifying Cascade.
Pressure-Enthalpy and the Variable Refrigerant Cycle
CUE – Make Any Pump an E-Pump
the compact air control solution
New MSP Concealed Ceiling Unit (FBQ-D & FXSQ-A)
BasicRefrigerationSystem 4 Component Flow Diagram.
Objectives Cooling Cycles –Examples Cooling system components Refrigerants.
Objectives Finish analysis of most common HVAC Systems Cooling Systems Describe vapor compression cycle basics Draw cycle on T-s diagrams Compare real.
Objectives Empathize with refrigerant Describe refrigeration cycles Analyze cycles on T-s diagrams Compare real cycles to ideal cycles Basis for discussion.
Page 1 LXMG PanelMatch™, StayLit™ Dual Lamp CCFL Inverter Module Training Kit Rev 1.1 November 2006
Problem Solving using Error Code Saijo Denki Inverter R-410A
© 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 5 August 2014.
DC Inverter Mini VRF Reference projects Reference Project Mini and Multi Improvements Product line -up.
Refrigerant system of Inverter R-410A. denki.co.th Model type Model : Stand Model : Duct Model : Cassette Model : Wall mount Model : Wall and.
2016 Chiller New Products Presentation.
Air condition installation
ARÇELİK TİCARİ KLİMA EĞİTİM DÖKÜMANI APPENDIX.
Refer to Service Manual for details Fault codes. To retrieve fault codes from the remote controller Press the ‘CHECK’ button for approximately.
CHIGO HVAC Product Introduction.
WSHP Systems 1.
Duct Free System.
The New Digital Inverter Light Commercial Range
New 10kW CAC & NCAC High wall unit.
Compact line ‘EW*D~J-’ water-cooled chiller range
CHIGO VRF System Commissioning.
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Cooling technology Main components and equipments
AHU connection kit.
DC Inverter Air-cooled Chiller Aqua Tempo Super II Series
Munters DOAS, Chilled Beams and VRV
Objectives Cooling Cycles Cooling system components Refrigerants
Lecture Objectives: Learn more about cooling cycles.
Fault codes.
Lecture Objectives: Analyze cooling cycles.
Objectives AHU processes - HW2 Cooling cycles.
Objectives Cooling Systems
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
MDS Smart Commander.
Objectives Solve one more example related to the psychometrics in AHU and building systems Learn about the psychometrics related to the cooling towers.
Total HVAC Control from anywhere Easy control that can save a fortune
Error codes for split systems
Liebert DSE High efficiency thermal management
Presentation transcript:

ERX-condensing units Strategic Marketing

2 17-Dec-15 1.Concept 2.Product range 3.Combination table 4.Piping length 5.Control possibilities 6.Benefits

3 17-Dec-15 Pair application: ERX + EV + control box + AHU ERX R410A inverter Sky Air Outdoor unit Air Handling Unit EV kit F1F2 communication Refrigerant piping Control box Field Supply 1. Concept ERX are R410A inverter units for use with AHU in pair applications ERX is always used in combination with expansion valve kit (EV kit) and a control box ERX can not be used with standard Sky Air indoors ERX are R410A inverter units for use with AHU in pair applications ERX is always used in combination with expansion valve kit (EV kit) and a control box ERX can not be used with standard Sky Air indoors DAikin Supply

4 17-Dec-15 Multi application : standard VRV outdoors + EV + control box : Standard VRV Outdoor unit Air Handling Unit EV kit Refrigerant piping Control box VRV indoor VRV indoor F1F2 communication Field Supply DAikin Supply 1. Concept

5 17-Dec-15 A. ERX Condensing Units (pair applications) ERX 100,125,140 (1 phase) ERX 125, 200 (3 phase) ERX 250 (3 phase) 2. Product range

6 17-Dec-15 B. EV Kit and Control Box (Pair and Multi) EV Kit Control box 2. Product range

7 17-Dec-15 ERX100 : EV 63 – 125 ERX125 : EV 63 – 140 ERX140 : EV 80 – 140 ERX200 : EV ERX250 : EV To allow max connection to AHU a range of expansion valve kits are available for each outdoor 3. Combination table

8 17-Dec-15 Piping limitations: Pair Application (Sky Air) Daikin condensing unit EKEXFCB EKEXDCB AHU EXV-kit DDC AB CD E F Total system : ≤ 30 m (Outdoor unit can be above or below the AHU) outdoor EXV-kit AHU ≤ 5 m Allowable height Piping Communication ERX 1 phase ERX 3 phase length : 5 < A ≤ 50m length : ≤ 5 m ≤ 100 m ≤ 20 m Depend On DDC ABCDEF 4. Piping length

9 17-Dec-15 Piping limitations: Multi Application (VRV) Daikin condensing unit EKEXMCBAHU EXV-kit DDC AB CD E F KIT n Indoor 1 Total system : ≤ 40 m (outdoor unit can be above or below the AHU) outdo or EXV-kit 1 AHU 1 ≤ 5 m Allowable height ≤ 5 m ≤ 15 m EXV-kit n AHU n Piping Communication VRV-III A+BBCDEF Consider Same as indoor length : ≤ 5 m ≤ 50 m Depend On DDC VRV Wiring policy 4. Piping length C/O 5~18 HP

10 17-Dec-15 AHU Te Ts Td Tr ROOM DDC X : Control of air Temperature (Td, Ts, Tr) with external controller (DDC)  PAIR Y : Control of evaporating Temperature (Te) with Daikin controller  PAIR Z : Control of air temperature (Ts, Tr) with Daikin controller  PAIR & MULTI 3 control systems can be selected : 5. Control possibilities

11 17-Dec-15 Te Ts Td Tr ROOM DDC EV kit Control box Example: Control X (pair) 5. Control possibilities

12 17-Dec-15 Example: Control Y (pair) (Te : 3~8°C) Te Ts Td Tr ROOM EV kit Control box 5. Control possibilities

13 17-Dec-15 Te Ts Td Tr ROOM Daikin EV kit Control box Example: Control Z (pair and multi) Controller 5. Control possibilities

14 17-Dec-15 System overview 5. Control possibilities XYZ Daikin Field supply System System A: Pair system : ERX OOO System B: Multi system : VRV --O Control parameterDischarge air control (Td)O-- suction air control (Ts)O-O Room air control (Tr)O-O Evaporating temp control (Te)-O- Components for control DDC (digital controller) O--field Air thermistorO--field Air thermistor -- ODaikin BRC1D - (2)- (2) (5) O (3)Daikin KRP4A (remote On/Off)--O (4)Daikin (2) not needed for control purpose (only for service: fault code detection) (3) required: to be ordered separately as option (4) possible, but not required: to be ordered separately as option. Supply of partsType of control EKEXFCBAV3 (customer can select X or Y) EKEXDCBAV3 (pair) EKEXMCBV3 (multi) (5) Te setting changed by BRC1D (=service tool)

15 17-Dec Control possibilities Control systems typedescriptionPROCONTRA Control type XBy DDC controller : 0-10 V control ΔT = T set - T measured T = Td, Ts or Tr - possibility for Td control - flexibility in applications - higher cost (DDC is needed) Control type Y Fixed Te Te = user setting : 3 ~8 °C - Low cost - no BRC needed no air temp control Control type Zusing BR1CD + KRP4 (remote on/off) Low cost - BRC/KRP4 needed - no possibility for Td control -ΔT+ΔTTset 0V 5V 10V output ΔTΔT T DDC set T measured 0~10 V

16 17-Dec-15 Customer benefits 1. Inverter outdoors (ERX or VRV) 2. Pair (ERX) and multi applications (VRV) 3. Extended control systems possible : control on evaporating temperature control on air temperature (suction / discharge / room temperature) Compared to Chillers : 1.Same small temperature gradient and control possibilities 2.No hydraulic components 3.Better price setting 6. Benefits

17 17-Dec-15