WGR Equivalent Modeling Keith Smith Network Model Engineer RARF Workshop III August 29, 2013.

Slides:



Advertisements
Similar presentations
Summary of Second Draft of the NERC Standard PRC Disturbance Monitoring and Reporting JSIS Meeting August 10, 2010 Salt Lake City, UT.
Advertisements

Announcements Be reading Chapters 9 and 10 HW 8 is due now.
New Energy Horizons Opportunities and Challenges Fault Current Contributions from Wind Plants Dean Miller PacifiCorp July 25,
Lesson 8 Symmetrical Components
Announcements Be reading Chapters 8 and 9
EE 369 POWER SYSTEM ANALYSIS
Name: Osamu TSUBOI Country: Japan Registration No.: Group: B5 Pref. Subject: 1 Question: 7 1 Question 7 Non-harmonic-restraint schemes applied in Japan.
Protection notice / Copyright noticeFor presentation in EWEC 2010 HVDC Solution for Offshore Wind Park Comprising Turbines Equipped with Full-Range Converters.
Lecture 31 EEE 302 Electrical Networks II Dr. Keith E. Holbert Summer 2001.
ECE 201 Circuit Theory I1 Source Transformation Convert a Voltage Source in Series with a Resistance into A Current Source in Parallel with the SAME Resistance.
CHAPTER 11 Balanced Three - Phase Circuits. CHAPTER CONTENTS 11.1 Balanced Three-Phase Voltages 11.1 Balanced Three-Phase Voltages 11.2 Three-Phase Voltage.
AC circuit breaker with series connected switches George G Karady.
Announcements Be reading Chapter 3
Unit Transformer Unit transformer are step up transformer which is connected to generating house & step up voltage from 15kV voltage to 132 voltage level.
© 2012 Siemens Industry, Inc. All rights reserved. Answers for infrastructure. ERCOT RARF Workshop Siemens PTI Procedures Alicia Dortch Nelson J Bacalao.
Resource Asset Registration Form Version 5.0 / 5.1 Changes for WGRs QMWG Presentation - July 9, 2012.
Electrical Power Distribution in America % Coal 20.4% Nuclear 20.3% Natural Gas 6% Hydro Electric 3.4% Other
SINTEF Energy Research 1 Fault ride-through testing of wind turbines Presented by: Olve Mo Paper co-authors: John Olav Tande Leif Warland Kjell Ljøkelsøy.
Current Contribution from Wind Plant for a System Fault Working Group C17 May 2010 Meeting.
1 Topics for discussion Network services Calculating RAB allocation Calculating average asset age Calculating line and cable.
Fault Level Monitor Ken Lennon LCNF Conference 25 th October 2012.
1 Chapter 3 Harmonic Modeling of Networks Contributors: T. Ortmyer, C. Hatziadoniu, and P. Ribeiro Organized by Task Force on Harmonics Modeling & Simulation.
1 © ABB AB, Application of Unit Protection Schemes for Auto-Transformers Zoran Gajić ABB AB Vasteras, Sweden Authors: Z. Gajić, ABB Sweden.
ECE 530 – Analysis Techniques for Large-Scale Electrical Systems
2015 RTP – Study Scope of Short Circuit Analysis RPG Meeting May 19,
RARF Frequently Asked Questions from Resource Entities Ed Geer RARF Workshop III 8/29/2013.
Announcements For lectures 8 to 10 please be reading Chapter 3
KD Relay Application: Compensator distance relay that provides a single zone of phase protection for all three phases. It provides tripping for phase to.
Engineering a sustainable future 1 ERCOT Voltage Ride-Through Study Workshop June 26 th, 2009.
Electric network faults seen by a wind farm – analysis of measurement data Sanna Uski, Seppo Hänninen, Bettina Lemström.
Announcements Please read Chapter 3; start on Chapter 6
RARF DATA for TYPES 3 & 4 WTGs Fault Current Contribution for Current Limited Resources Ed Geer, P.E. Network Model Engineer, Sr. SPWG Meeting July 17,
IEEE PES General Meeting, Tampa FL June 24-28, Chapter 3 Harmonic Modeling of Networks Contributors: T. Ortmyer, C. Hatziadoniu, and P. Ribeiro.
SPWG SHORT CIRCUIT CASE BUILDING AND DEVELOPMENT July 17, 2014 Qiuli Yu and Jay Teixeira ERCOT.
NPRR425 - Creation of a WGR Group for GREDP and Base Point Deviation Evaluation and Mixing Turbine Types Within a WGR Art Deller, P.E. RARF Workshop 8/29/13.
Resource Asset Registration Form Version 5.1 Update July 12, 2012.
1 Department of Electrical & Communication Engineering CHAPTER 1 Per Unit Calculations 1.Power System Representation Power Component SymbolPower ComponentSymbol.
Power Quality Impacts of Distributed Generation Roger C. Dugan Sr. Consultant Electrotek Concepts, Inc. Tennessee Tech. February 9, 2004.
Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution Engineering Technology Division.
Announcements For lectures 9 and 10 please be reading Chapter 3
Georg Koeppl, Dieter Braun Koeppl Power Experts ABB
Announcements Read Chapters 8 and 9 HW 9 quiz today
Lecture II Objective: Representation of sequence components
Electrical Engineering
The Smith Chart Developed in 1939 by P. W. Smith as a graphical tool to analyze and design transmission-line circuits Today, it is used to characterize.
Per-Unit System.
Grounded Wye-Delta Transformer Bank Backfeed Short-Circuit Currents W. H. Kersting & Wayne Carr Milsoft Utility Solutions.
البحث السابع بحث منفرد منشور فى مؤتمر دولى متخصص (منشورة التحكيم علي البحث الكامل) Adel A. Elbaset 13th International Middle East Power System Conference,
NEUTRAL CURRENT IS NOT ZERO
Power System Protective Relaying-Part Two
Hao Zhu Dept. of Electrical & Computer Engineering University of Illinois, Urbana-Champaign ECE 498HZ: Power Distribution System Analysis.
CHAPTER 6 SPECIAL TRANSFORMERS Electrical Machines.
2004 Cigre SCB5 Session Preferential Subject 3
Per-Unit System.
PRACTICAL METHOD FOR ANALYSIS OF GROUNDING SYSTEM OF HV/MV SUBSTATIONS LOCATED IN URBAN AND SUBURBAN AREAS.
Luka Strezoski Marija Prica
ELEC-E8409 HIGH VOLTAGE ENGINEERING
SIGMA INSTITUTE OF ENGINEERING DEPARTMENT OF ELECTRICAL ENGINEERING
POWER SYSTEM ANALYSIS EET308/3 EET308 POWER SYSTEM ANALYSIS.
Click to Continue to Calculator window
Calculations: Transformers and Service Conductor Calculations
Transformer Impedance
Exercise 7 Power systems.
Exercise 10 Power systems.
Exercise Session 2 Power systems.
Smitty’s Two Minute Drill Grounding and Bonding
Power System Analysis (EELE 4351)
Prepared by: Ismael K. Saeed
Exercise Session 11 Power systems.
Exercise 9 Power systems.
Presentation transcript:

WGR Equivalent Modeling Keith Smith Network Model Engineer RARF Workshop III August 29, 2013

2 System Protection Model Equivalent –Aggregated turbines modeled at.69 kV –Turbine step-up transformers aggregated into one kV transformer –Collector system represented as single line –Provides more accurate fault data than aggregate turbine modeled at 34.5 kV level –Grounded Wye-Delta connection very common for turbine step-up transformers, limits single line to ground fault current contributions from turbine WGR Equivalent Model

3 Calculating impedances for equivalent model –Equivalent turbine impedance calculated as N turbines in parallel –Equivalent transformer impedance calculated as N transformers in parallel –Equivalent collector system impedance calculated from collector system cable data using the following equation: –Where n = number of turbines feeding cable segment N = number of total turbines Equivalent Methodology

4 3-Phase to Ground Fault Full System

5 3-Phase to Ground Fault Equivalent

6 Single Line to Ground Fault Full System

7 Single Line to Ground Fault Equivalent

8 Collector System Example

9 Collector System RARF Format GENERATOR DETAILSCable TypeWIND SEGMENT DETAILS Resource Name (Unit Code/Mnemonic)Cable TypeFromToCircuit Number Voltage Level Cable Segment Length Number of Turbines On Cable Segment List alpha/numeric kVin kftInteger WIND_FARM1000 kcmil WIND_FARM1/0 AWG WIND_FARM1000 kcmil WIND_FARM1/0 AWG WIND_FARM1/0 AWG WIND_FARM500 kcmil WIND_FARM500 kcmil WIND_FARM4/0 AWG WIND_FARM1/0 AWG WIND_FARM1/0 AWG WIND_FARM1/0 AWG WIND_FARM1000 kcmil GENERATOR DETAILS COLLECTION SYSTEM DETAILED MODELPOSITIVE SEQUENCE DATAZERO SEQUENCE DATA Resource Name (Unit Code/Mnemonic)Cable Type Voltage Level kVR/kftX/kftCharging Bc/kftR0/kftX0/kft List kV(p.u. on 100 MVA base) WIND_FARM1000 kcmil E WIND_FARM500 kcmil E WIND_FARM4/0 AWG E WIND_FARM1/0 AWG E

10 Generator Data Required turbine data for system protection cases

11 Current Limits Required for type 3 and type 4 turbines

12 QUESTIONS?