ConfidentialConfidential Electromagnetic Type Digital Flow Switch LFE Series Integrated display type Separated type Sensor Display.

Slides:



Advertisements
Similar presentations
Star kW NEW. Star kW Star kW Instantaneous wall-hung gas boilers Conventional flue Sealed room fan assisted NIKE Star 23 kW EOLO Star 23 kW.
Advertisements

Pre Sales Dept. HERCULES Solar 26 1 A Condensing floor-standing boilers with built-in solar circuit.
Customer Service – International dept. STAR 24 3 E.
ULTRASONIC WATER AND FLOW METERS
Thermostats, Pressure Switches, and Other Electric Control Devices
Setup/Installation/Operation of an Environmental Control Unit (ECU)
WIRED TYPE MULTI ZONE FANCOIL CONTROL SYSTEM MODEL : WSF- 700 SYSTEM
Home Refueling. Phill Technical Training Natural Gas Vehicle Components What is a Natural Gas Vehicle?
1. 2 Maintenance & Troubleshooting 3 Maintenance Three-monthly checks Carry out the following checks every three months: check the power supply; check.
38GXC(Q)/40GXC(Q) Service Training Sizes 18 and 24K.
Datasheet System Conquest 6_ _01 1/9 CONQUEST 6 Electronic control system for whirlpool Product datasheet VALANTIS SARL CH – 2610 ST-IMIER.
» When you have completed this module you will know, what components do, what they physically look like and how they are represented in a circuit diagram.
Mechanical AST5300 is a wet / wet differential pressure transmitter Compatible with liquids or gases on both the high pressure and low pressure process.
DIGITAL LIGHT METER Dr. Lim Jac Fang Occupational Health Doctor Department of Health, Sabah 1994 CT Lutron LX-105 LIGHT METER.
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
Product Introduction.
How to use the STELR multimeter
T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R SineWave - Installation rules.
Settings & Adjustments. Settings & Adjustments.
Color Sensors We Know Until Now, Our History with Color Sensing Technology has Been Limited to a Class of Sensors Known as “Color Mark” Sensors Our Offerings.
Hygienic Cylinder HYG  20 to  63 Series Easily wiped Improved waterproof Completely contained guide rod in body.
High Sensitivity Smoke Detection
XMLK The ideal choice for water distribution 4…20 mA or 0….10V output M12, DIN or Metri-Pack electrical connection ¼” NPT male or G1/4 A male fluid entry.
Vacuum system.
Page 1 LXMG , LXMG LXMG , LXMG PanelMatch™, StayLit™ Dual Lamp CCFL Inverter Modules Training.
MODEL : EDF-102 SERIES 1. APPLICATION The EDF-102 thermostat is designed to provide temperature control of heating or cooling systems in villas, hotels.
Experts in Chem-Feed and Water Treatment beta Metering Pumps 1.
Pressure-Enthalpy and the Variable Refrigerant Cycle
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
For application of changes OSHA Standard Pressure Relief 3 Port Valve with Locking Holes Existing Series VHS20~50 (Discontinued) New Series VHS20~50-A,B.
For internal use only Ionizer Bar Type IZS40, IZS41, IZS42 Series IZS40 IZS41 IZS42.
Serial Transmission System Series EX510 BackgroundFeaturesTechnical detailsApplications.
PF3W Series 3-Color Display Digital Flow Switch Planned release date: May 2012.
Ejector with Pad ZHP Series Confidential Internal use onlyConfidentialConfidential.
Water Detectors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
Vacuum Unit ZK2 Series The ZK2 series is a product compatible with both of the vacuum ejector and vacuum pump system.
06/01/2016 TE-SM/Haiying GuoSPAB Customer Presentation Compact pressure sensor SPAB 1.
High frequency solenoid valve SX10 Series
Trimmer Auto Switch (Sensor unit) D-M9K Series. Conventional product Rail Mounting(D-F7K) CQ2(  12 to  160) Fit to the round groove Conventional style:
Ionizer IZS31 Series. 1. Features (1) Following functions are added to the current IZS30 on sale. Detects the dirt on the electrode needle. Detects the.
Slider Type 11-LEJS Clean Series Electric Actuator Vacuum suction
社内資料社内資料 E-P Regulator for High Pressure up to 5.0MPa ITVX Series * This product is only for blowing, and does not have sufficient control for other application.
Main contacts closed – RED Colour with ON
Page 1 LXMG PanelMatch™, StayLit™ Dual Lamp CCFL Inverter Module Training Kit Rev 1.1 November 2006
FEATURES USER’S MANUAL COLOR BOX CAMERA SDB-BAW SDB-BAW/T 1/3 " SONY 960H Dual Scan CCD High Resolution of 800TV Lines Min. Illumination of Lux at.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
SDD-DAW30IRV COLOR IR DOME CAMERA USER’S MANUAL 1/3 " SONY 960H Dual Scan CCD High Resolution of 800TV Lines Min. Illumination of Lux at F1.2 (Sense-up)
How to Build a Digital Physical System - Lab Lecture 2.
SDD-C425 COLOR DOME CAMERA USER’S MANUAL FEATURES MEMO 1/3” SONY 960H Super HAD II CCD High Resolution of 700TV Lines Min. Illumination of 0.1Lux at F1.2.
UTH-65A VER. CAUTIONS ! PLEASE USE THE OUTLET PREPARED BY A QUALIFIED SERVICEMAN AND MUST CONFIRM IT BEFORE APPLY[SING AN ELECTRIC CURRENT.
Air condition installation
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
IP 67-A Perfect Waterproof LCD TV
C1300 advanced circular chart recorder
HD-SDI DOME CAMERA SDI-DC221 SPECIFICATIONS MEMO USER’S MANUAL
Block Diagram Transmitter Receiver × 2 Transmitter Power Supply ADC
Copyright SwissFlow B.V.
Constant Voltage Source for LED drive
Module – Groundwater Level Measurement
Customer Presentation
Customer Presentation
Customer Presentation
Product Training Module
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
FLOWTECH PRODUCTS LLP “PIONEERS IN FLOW CONTROLS & MEASUREMENTS”
Automatic operation IR rework system Automatic Component placement 2 x K-type thermocouples IR-pyro sensor RPC-camera.
Presentation transcript:

ConfidentialConfidential Electromagnetic Type Digital Flow Switch LFE Series Integrated display type Separated type Sensor Display

ConfidentialConfidential 1. Purpose of development For flow control of cooling water for moulding and welding guns and leakage control tip cooling water, the liquid which is measured by flow meter is mainly industrial water. Flow meter types such as float, impeller or Karman vortex are used, but they all have problems with clogging. ↓ (1) Small pressure loss (2) No clogging (3) Small flow meter for liquid Require development

ConfidentialConfidential 2. Features (1) No obstacles in the fluid path. Compact and lightweight. Smooth fluid path with no moving parts is resistant to clogging. Light weight ⇒ 340g ( value for LFE1*3)

ConfidentialConfidential 2 . Features (2) Low pressure loss (0.02MPa or less) (for LFE1 and LFE2) LFE1 LFE2 LFE3 Pressure loss (MPa) Flow rate (L/min) Pressure loss (MPa) Flow rate (L/min) Pressure loss (MPa) Flow rate (L/min)

ConfidentialConfidential Backflow can be detected 2 . Features (3) Flow direction can be changed after installation Normal flow. (Left --> Right) Backflow (Right --> Left) IN OUT Normal flow. (Left --> Right) Backflow (Right --> Left) Backflow error displayed

ConfidentialConfidential 3 colour, 2 display indication Example of lower screen (Upper screen is for instantaneous flow rate) Upper screen Lower screen (Lower screen) Set value Accumulated Peak/ bottom Line name value value 2. Features (4) Wide range (Wide rated flow range)  LFE1 : 0.5 to 20 L/min  LFE2 : 2.5 to 100 L/min  LFE3 : 5 to 200 L/min

ConfidentialConfidential 3. Applications Flow control of cooling water for welding gun, leakage control of tip cooling water. Flow control for cooling water for mold Flow control for aqueous coolant

ConfidentialConfidential 4. Specifications and Performance (1) ModelLFE1LFE2LFE3 Applicable fluidWater or liquids which do not corrode the fluid contact materials. Applicable electrical conductivity  5 μS/cm Rated flow range0.5 to 20.0 L/min2.5 to L/min5 to 200 L/min Display and settable value range 0.4 to 24.0 L/min2.0 to L/min4 to 240 L/min Min. setting unit0.1 L/min0.5 L/min1 L/min Accumulated flow range L L Repeatability Display value: +/-2 % F.S. analog output: +/-1.5 % F.S. Operating fluid temperature 0 to 85 o C (No freezing or condensation) Ambient temperature0 to 50 o C (No freezing or condensation) Temperature characteristics +/-5 %F.S. (25 o C reference) Operating pressure range 0 to 1 MPa Proof pressure2 MPa Integrated display type (1)

ConfidentialConfidential 4 . Specifications and Performance (2) ModelLFE1LFE2LFE3 Switch outputNPN or PNP open collector Max. load current: 80mA, max. applied voltage: 28V Analogue output Voltage output 1 to 5V (Output impedance 1kΩ) Current output 4 to 20 mA (Maximum load impedance 600Ω) Response timeCan be selected from 0.25 s, 0.5 s, 1s, 2s, and 5s. (63% response) Display type 2 screen display Upper screen: 7seg 4 digits Red / Green 2 colors Lower screen: 11seg 6 digits White Operation LEDOutput 1, 2 orange Power supply voltage24V DC +/-10% Current consumption45 mA or less (Load current is not included) EnclosureIP65 ComplianceCE marking, RoHS Materials of fluid contact parts PPS 、 FKM 、 C37 Port size3/8inch(10A)1/2inch(15A)3/4inch(20A)1inch(25A) Weight340 g400 g520 g680 g Integrated display type (2)

ConfidentialConfidential 4 . Specifications and Performance (3) ModelLFE1LFE2LFE3 Applicable fluidWater or liquids which do not corrode the fluid contact materials. Applicable electrical conductivity  5 μS/cm Rated flow range0.5 to 20.0 L/min2.5 to L/min5 to 200 L/min RepeatabilityAnalogue output: +/-1.5%F.S. Operating fluid temperature 0 to 85 o C (No freezing or condensation) Ambient temperature 0 to 50 o C (No freezing or condensation) Temperature characteristics +/-5 %F.S. (25 o C reference) Operating pressure range 0 to 1 MPa Withstand pressure2 MPa Remote type sensor (1)

ConfidentialConfidential 4 . Specifications and Performance (4) ModelLFE1LFE2LFE3 Analogue output Respons e time 0.5 s Voltage output 1 to 5V (Output impedance 1kΩ) Current output 4 to 20 mA (Maximum load impedance 600Ω) Power supply voltage24V DC +/-10% Current consumption42 mA or less (Load current is not included) EnclosureIP65 ComplianceCE marking, RoHS Materials of fluid contact parts PPS 、 FKM 、 C37 Port size3/8inch(10A)1/2inch(15A)3/4inch(20A)1inch(25A) Weight335 g395 g515 g675 g Remote type sensor (2)

ConfidentialConfidential 4 . Specifications and Performance (5) ModelLFE0 Display range0.4 to 24.0 L/min2.0 to L/min4 to 240 L/min Min. setting unit0.1 L/min0.5 L/min1 L/min Accumulated flow range L L Accuracy Display value: +/-0.5 % F.S. Analogue: +/-0.5 % F.S. Repeatability0.5%F.S. Operating temperature range 0 to 50 o C (No freezing or condensation) Temperature characteristics +/-0.5 %F.S. (25 o C reference) Separate monitor (1)

ConfidentialConfidential 4 . Specifications and Performance (6) ModelLFE0 Switch outputNPN or PNP open collector Max. load current: 80mA, max. applied voltage: 28V Analogue output Voltage output 1 to 5V (Output impedance 1kΩ) Current output 4 to 20 mA (Maximum load impedance 600Ω) Response timeCan be selected from 0.5 s, 1s, 2s, and 5s. (63% response) Input and outputInput for copy mode Display type 2 screen display Upper screen: 7seg 4 digits Red / Green 2 colors Lower screen: 11seg 6 digits White Operation LEDOutput 1, 2 orange Power supply voltage24V DC +/-10% Current consumption50mA or less (Load current is not included) EnclosureIP40 (Note that only the display front is certified as IP65 by using optional panel mount adapter and waterproof seal). ComplianceCE marking, RoHS Weight50 g Separate monitor (2)

ConfidentialConfidential 5 . Construction (Sectional view) Electrode Coil Seal (FKM) Attachment (C37) Pipe (PPS) Body (PBT) M12 connector

ConfidentialConfidential 5 . Construction (Sectional view) Electrode Coil Seal (FKM) Attachment (C37) Pipe (PPS) Body (PBT) M12 connector

ConfidentialConfidential 【 SMC 】【 TT 】 Series nameLFE series (Integrated type)FD-M series ModelLFE1LFE2LFE3FD-M10FD-M50FD-M100 Detecting methodElectromagnetic flow meter with Electrostatic capacity Rated flow range [L/min] 0.5 to to 1005 to to to 505 to 100 Display and setting range [L/min] 0.4 to to 1204 to to to 1005 to 200 Fluid temperature characteristic [%F.S.] +/-5 % (25 o C reference)Not known Fluid temperature range: 0 to 85C o Response time [s]Available from 0.25, 0.5, 1, 2, and 5Available from 0.5, 1, 2.5, 5, 10, 30, and 60 Repeatability [%F.S.] +/-20.5s: +/-5, 1s:+/-3.5, 2.5s: +/-2.5 5s: +/-1.6, 10s:+/-1, 30s: +/ s : +/-0.6 Dimensions [mm] (W×H×L) 40×56 ×90 50 x 67 x x 73 x x 54.1 x ×65.1 ×120 70×71.1 ×130 Weight (g) . Comparison with competitors

ConfidentialConfidential 7 . How-to-Order (1) Integrated type sensor Rated flow range Sym bol Rated flow range 10.5 to 20 L/min 22.5 to 100 L/min 35 to 200 L/min Sym bol OUT JAnalogue 1 to 5V KAnalogue 4 to 20 mA LFE1A3 Output spec. Port size Sym bol OUT1OUT2 ANPN BPNP CNPNAnalogue 1 to 5V DNPNAnalogue 4 to 20 mA Thread type Sym bol Port sizeApplicable models LFE1LFE2LFE3 3 3/8 inch ● - - 4 1/2 inch ● - - 6 3/4 inch - ● - 8 1 inch - -● Remote type sensor LFE1J3 Option Output spec. Symbol M12 connector Lead wire (Length 3m) Bracket Unit specificati on Nil ● - L/min ●● 3- ● 4 ● - Gal/min ●● 7-● Symbol NilRc NNPT FG

ConfidentialConfidential Separate monitor 7 . How-to-Order (2) Type 0Separate monitor LFE0A - MVC Output spec. Symbol OUT1OUT2 ANPN BPNP CNPNAnalogue 1 to 5V DNPNAnalogue 4 to 20 mA Lead wire Option 2 Option 1 Symbol Nil With lead wire for power supply/ output NWithout lead wire for power supply/ output Symbol NilNone TPanel mount adapter VFront protective cover + Panel mount adapter Symbol NilWithout connector CSensor connector (1 pc.) Unit specification Symbo l Instantaneous flow Accumulated flow ML/minL GGal/mingal

ConfidentialConfidential 8 . Dimensions (1) A B C D E F G 2 x port size H I J 4 x K Symbol Model Piping Port size ABCDEFGHIJK LFE1□3 3/ F2.5 depth 5.5 LFE1□4 1/ F2.5 depth 5.5 LFE2□6 3/ F2.5 depth 5.5 LFE3□ F2.5 depth 5.5 (Dimensions for remote type sensor are the same as display integrated type.) Dimensions for display integrated type and remote type sensor

ConfidentialConfidential 8 . Dimensions (2) 40 □ (7.5) □42.4 Front protective cover Water proof seal Panel Panel mount adapter 9.2(2) Dimensions for separate monitor Front protective cover + Panel mount adapter

ConfidentialConfidential Completely fill the fluid passage with water. The product cannot measure correctly if the fluid passage is not completely filled. If the product is installed vertically, do not apply flow from the top to bottom. Bubbles may cause malfunction. Ensure the product is used within the operating temperature range. Operating temperature range is 0 to 50 o C, fluid temperature range is 0 to 85 o C. When multiple sensors are used in parallel, install them outside of the area shown below. 9 . Cautions for handling (1) 50mm 20mm Uninstallable area

ConfidentialConfidential Positive ground power supply cannot be used. Short-circuit DC(+) DC (-) OUT1 OUT2 DC(+) The switch cannot be used for equipment in which piping or installation side is connected to DC(+). In order to identify ground, use a voltage tester and place it on the control board power source DC(-) and the tubing. If the measured voltage is 0V then it is a negative ground. If the measured voltage is 24V then it is a positive ground. Always assure that the customer is advised of this measuring method. Piping port and the metal part of the body are grounded to DC(-)/ blue line. 9 . Cautions for handling (2)

ConfidentialConfidential 9 . Cautions for handling (3) Use liquid with 5μS/cm or higher electrical conductivity. This product cannot be used for fluids with low electrical conductivity. This product cannot be used for fluids that do not conduct electricity such as gas, de-ionized water and oil. Fluid Applicability Note Water ○ Conductivity of tap water: 100 to 200μS De-ionized water X Electrical conductivity is low Aqueous coolant ○ When water ratio is more than 50% Oil X Electrical conductivity is low Oil based coolant X Electrical conductivity is low Sea waterXFluid contact part is corroded GALDEN R X Electrical conductivity is low. Fluorinert TM X Electrical conductivity is low. GALDEN R is a registered trademark of Solvay Solexis, and Fluorinert TM is a registered trademark of 3M.

ConfidentialConfidential Please download the manual for this product from the SMC World Website Please be aware that the manual is not included with the product. Please download the manual from the following website. 9 . Cautions for handling (4)

ConfidentialConfidential 9. Cautions for handling (5) For reference Industrial water Rain water Deionized water Ultra pure water Distilled water Tap water Water base coolant CPEP MP 0.055μS/cm LFE series PF3W series Foreign matter may be in fluid. Prevention against clogging is desired. ↓ LFE series has smooth fluid passage. Clean water is used. There should be no clogging. ↓ Compact PF3W series is recommended. User Electrical conductivity of liquid Electrical conductivity of fluids (Reference) 0.1μS/cm1μS/cm10μS/cm100μS/cm 1000μS/cm Differentiate from close product (Karman vortex type: PF3W series.

ConfidentialConfidential 10 . Definition and terminology Electric conductivity Electrical conductivity is a measure of how well electricity flows. Unit is "S/cm (Siemens/ centimeter)". Reference) Tap water 100 to 200μS/cm (5 to 10Ω ・ cm) Distilled water Approx. 5μS/cm (200Ω ・ cm)

ConfidentialConfidential 11 . Summary Compact and light weight. No obstacles or moving parts in the fluid passage.  Resistant to dust or clogging.  Low pressure loss. Backflow can be detected. Flow direction can be changed after installation Good visibility  3 colour 2 display indication shows instantaneous flow rate and the set value simultaneously. Wide range Quick response. High repeatability.

ConfidentialConfidential Q&A (1) Gas fluid can be measured. (2) All types of coolant liquid can be measured. (3) Contaminated liquid may cause clogging. Filter is necessary. (4) Instantaneous flow and set value are displayed simultaneously. (5) Both integrated type and separated type can detect backflow. (6) If the product is installed vertically, do not apply flow from the top to bottom. Bubbles may cause malfunction. (7) Response time is fixed to 1s. (8) Maximum display and set values are the same as rated flow range. (9) Product can be used with any piping condition. (10) Electrical conductivity is a measure how well electricity flows.