Engineered for Uptime Strategies for Designing Reliable Data Centers and Networks.

Slides:



Advertisements
Similar presentations
SM. FlexPod site readiness assessment services verify that all required Layer 1 Physical Infrastructure items are in- place, properly installed, and correctly.
Advertisements

Cabling system components
Network Design Issues Design and Documentation Prepared by: Aline L. Mendoza.
Chapter 3: Planning a Network Upgrade
MFS, MPO 4/8/12-Fiber connectors and Fan-Out assemblies.
SAN Last Update Copyright Kenneth M. Chipps Ph.D. 1.
Optical Fiber: How About Fiber to YOUR Desk? Presented by: Bob Ballard, RCDD Registered Communications Distribution Designer Certified Fiber Optics Installer.
Cabling Structured Cabling Standards
Physical Transmission Media 8 5/9/ Modified by: Brierley.
Campus LAN Overview. Objectives Identify the technical considerations in campus LAN design Identify the business considerations in campus LAN design Describe.
Physical and Network Topology Security
Fixed Mobile Convergence T Research Seminar on Telecommunications Business Johanna Heinonen.
1 Northwestern University Information Technology Data Center Elements Research and Administrative Computing Committee Presented October 8, 2007.
111 © 2002, Cisco Systems, Inc. All rights reserved. Trim out phase steps Cutting cables to length Labeling cables Dressing cables Terminating cables Installing.
Classes of transmission media
1 Version 3.0 Module 3 Networking Media. 2 Version 3.0 Cable Specifications Cables have different specifications and expectations pertaining to performance:
NETWORK DESIGN Customer requirements Network topologies Cable choice Hardware TSB 75 TSB72.
Data Center Global Telecommunications Cabling Standards Landscape and Latest Developments Jonathan Jew - J&M Consultants, Inc. Chair TIA TR-42.6 Telecom.
Designing and Implementing Cabling Infrastructure Dr. Saif al Zahir King Fahd University of Petroleum & Minerals Computer Engineering Department Dr. Saif.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Rael Haiboullin System Engineer Capacity Manager.
University of Oklahoma Network Infrastructure and National Lambda Rail.
Router. Switch Repeater Cable is the medium through which information usually moves from one network device to another. It used to connect one network.
Many Roads To Home. LAN Roads UTP STP Coaxial Fiber Optics.
Copyright CCNA 1 Chapter 4, Part 1 Cable Testing By Your Name.
CSE 550 Computer Network Design Dr. Mohammed H. Sqalli COE, KFUPM Spring 2007 (Term 062)
The physical network Unit objective: Identify network cables and connectors, and use networking tools.
Computer Communications and Networking (CCN)
Cisco 1 - Networking Basics Perrine. J Page 19/3/2015 Chapter 3 Which of the following correctly describes the type of signal that the network media carries?
Section 11.1 Identify customer requirements Recommend appropriate network topologies Gather data about existing equipment and software Section 11.2 Demonstrate.
1 Nexans Cabling Solutions Easy and reliable migration from fast to faster to100G.
Chapter 2.  Types of Network  Circuit Switched & Packet Switched  Signaling Techniques  Baseband & Broadband  Interference  Transmission Medium.
Network PHY - Cabling Cabling Issues with cabling LANs Types of equipment/choices Version2, 12/09/2015Slide 1.
Physical Transmission Media Chapter 8. Objectives In this chapter, you will learn to: Identify the characteristics of wireline transmission Describe the.
1. 1. Overview: Telecommunications Project  Planning and implementation (2007-today) 2. Discussion: Proposal to Improve Infrastructure  Upgrade horizontal.
National Institute of Science & Technology 1 TECHNICAL SEMINAR REPORT 10 GIGABIT ETHERNET TECHNOLOGY.
Gigabit Ethernet.
CSCI 465 D ata Communications and Networks Lecture 19 Martin van Bommel CSCI 465 Data Communications & Networks 1.
Lecture 8 Cable Certification & Testing:. Cable Distribution Cable Distribution Equipment UTP (Unshielded Twisted Pair) UTP Cable Termination Tools UTP.
LAN Switching and Wireless – Chapter 1
Data Centre – Managing a Reliability Quotient Bala Chandran.
LAN Switching and Wireless – Chapter 1 Vilina Hutter, Instructor
SiteWiz – RiT ’ s CAM Solution. Daily IT Challenges Overload of infrastructure information Numerous daily changes Many departments involved No clear picture.
1 Recommendations Now that 40 GbE has been adopted as part of the 802.3ba Task Force, there is a need to consider inter-switch links applications at 40.
SIGNAMAX CABLING SYSTEM. Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements.
 Cables  Network Interface Card (NIC)  Repeaters  Hubs  Switches  Routers  Gateways  Bridges.
Gary Marret, RCDD WHAT IS ETHERNET? WHAT IS ETHERNET? WHAT IS ETHERNET/IP? WHAT IS ETHERNET/IP? ETHERNET HARDWARE? ETHERNET HARDWARE? HOW DO I CABLE.
COPPER AND FIBER REVIEW
Ipswich City Precinct. 6. ICC Precinct Installation Standards & Regulatory Compliance ICT Infrastructure Integration & Convergence 1. Pit & Pipe Underground.
Transmission Media. Characteristics to consider for Media Selection Throughput Cost Installation Maintenance Obsolescence vs bleeding edge Support Life.
Local Area Networks: Monil Adhikari. Primary Function of a LAN File serving – large storage disk drive acts as a central storage repository Print serving.
LECTURE#6 - CABLES Asma AlOsaimi. Copper Coaxial Cable - Thick or Thin Unshielded Twisted Pair - CAT 3,4,5,5e&6 Optical Fiber Multimode Singlemode Wireless.
SIGNAMAX CABLING SYSTEM. Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements.
Data and Computer Communications Eighth Edition by William Stallings Chapter 15 – Local Area Network Overview.
1 Rick Dallmann Session: DB 1.1 Designing Next-Generation SAN/Storage Optical Infrastructure Why Low Link (Budget) Loss is Critical.
1 DB 1.3 Case Study: eBay’s 40G/100G Network Upgrade Shawn Tugwell, Sr. Data Center Design Engineer – eBay Gary Bernstein, RCDD, CDCD Sr. Director of Product.
Real Life Optical LANs “experiences so far and solution enhancements in the pipeline” Rev1.
Physical Network Design. Phiysical Network Design Selecting Technologies and Devices for – Campus Networks – Entreprise Network.
COMMUNICATION SYSTEMS IN BUILDINGS/CAMPUSES
Physical Transmission Media Chapter 8. Objectives In this chapter, you will learn to: Identify the characteristics of wireline transmission Describe the.
IST 126 Computer Networks Spring, What is a Computer Network? A group of computers and other devices that are connected together in order to share.
LECTURE#6 - CABLES Asma AlOsaimi. Copper Coaxial Cable - Thick or Thin Unshielded Twisted Pair - CAT 3,4,5,5e&6 Optical Fiber Multimode Singlemode Wireless.
Network Topology and LAN Technologies
10 GIGABIT ETHERNET TECHNOLOGY
Level 2 Diploma Unit 10 Setting up an IT Network
Optical-Based Switching Solutions
10 Gigabit Ethernet 1 1.
CHAPTER 3 Physical Layer.
Data Center Colocation Services.
Data Center Colocation Services.
Business Data Communications, 4e
Presentation transcript:

Engineered for Uptime Strategies for Designing Reliable Data Centers and Networks

2 Agenda Engineering your Data Center for Uptime Leveraging 10 Gig in the Data Center Design Considerations TIA, ISO, IEEE Standards Pathways & Spaces

Data Center Design Engineering your Data Center for Uptime

4 Outline Data Center Applications Data Center Infrastructure Design and Standards Network Engineer Concerns Data Center Standards Summary

5 Data Center Defined A Data Center is dedicated area within a building for connecting servers to the internal and external network Key Functions/Applications –Storage of important data (websites, transactions, video, voice, logs, records) –24x7x365 immediate access to information from anywhere –Reliability and Redundancy

6 Trends impacting the Data Center IP Convergence (More devices in LAN requiring Ethernet connections) Blade Servers (higher density servers) 10 Gigabit Speeds (copper and fiber) Storage Area Networks (Massive Hard Drive Arrays for the long term storage of information) Key Point: All of the above are very positive trends for high end Structured Cabling – Why?

7 Baseline IP Bursty VoIP WAP Security Lighting HVAC IP Convergence Drives More Cable into LAN and Data Center More Networked Devices drive additional Equipment in Data Center

8 Blade Servers increase the density of cabling in the data center Blade Servers (IBM shown below): –Increase density of cabling as there are physically more servers per cabinet –Increase heat generated in cabinet (Airflow becomes more important)

9 10 Gigabit Speeds require upgraded cabling No one will debate the fact that Data Centers will be the first to deploy 10 Gigabit –They are already doing it over fiber –Active equipment vendors recommending all new copper cabling be Augmented Category 6 to support 10GBase-T 10 Gig over Fiber – Laser optimized MM 10 Gig over Copper – Augmented Category 6

10 Why Design for 10 Gigabit? Philosophy of “Building for Bandwidth” –Cabling expected life: Years (12.5 yr Avg.) –Active Equipment expected life: 3-5 Years (4 yr Avg.) »Force10 Targeting extended up to 10 year life –Conclusion: Cabling needs to be design to last at least 3 generations of active equipment Recent release of 10GBase-T (IEEE 802.3an) in June of 2006 –Equipment manufacturers working on early prototype solutions, expect the early commercial availability of NIC’s and Switches in 2007

11 Why Design for 10 Gigabit? Interesting Statistics –IEEE Higher Speed Study Group is looking at 100 Gbps Ethernet over fiber in the 2010 timeframe

12 Storage Area Networks (SANs) require a high density of fiber SANs generally connect a high capacity hard disk arrays to the data center via Fiber Channel (not Ethernet, yet) Number of connections demand high density fiber cable management solutions

13 Network Engineer Concerns within the Data Center Scalable –Density of equipment, cabinets, frames –Fast and Accurate Moves, Adds, and Changes Thermal –Problematic in most data centers (designed before Blade Servers) –Poor Air Flow a Problem in many Data Centers Reliability/Uptime –Cannot afford any downtime, even during expansion How can structured cabling positively impact each area of concern?

14 Scalability Managed Density – Proper design and cable management enhance the ability to track and maintain circuits. Fast and Accurate MAC work – Products should be designed to be easy to install and manage. –The four fundamentals of Fiber Management Address these issues

15 Foundation of Fiber Connectivity Four Key Elements of Fiber Cable Management –Bend radius protection –Cable and connector access –Intuitive cable routing paths –Physical protection

16 Thermal Proper Cable Management promotes good air flow –Overhead Fiber cabling through fiber raceway eliminates “Air Dams” below the raised floor –Cable Management organizes cables so they don’t restrict airflow to switches and servers

17 High Density Chassis Switches with very poor cable management 2:1 ratio Patch Panel to Horizontal Manager Inadequate Cable Management

18 Overhead Fiber Raceway Example FiberGuide –The key to optimizing air flow in the Data Center –Provides bend radius protection, physical protection, and segregation of fiber optic jumpers –Excels at all the key attributes of a good Fiber Raceway solution: »Flexibility »Speed of installation »Speed of deployment »Durability »Fiber protection

19 Reliability of Data Center Equipment is Directly Tied to Proper Cooling Proper Data Center Design deployment of Hot Aisle/Cold Aisle Cooling –Good Airflow/Proper Cooling = Optimal Performance of Servers and Switches

20 Reliability of Data Center Equipment is Directly Tied to Proper Cooling But what happens if poor cable management blocks airflow?

21 Reliability of Data Center Equipment is Directly Tied to Proper Cooling Cables blocking air inlets and exits will raise the temperature of switches and servers lowering their reliability!

22 Cabling the Data Center Copper or Fiber? Both! Fiber Optic Cabling –Backbone cabling –Horizontal cabling over 100 meters –SAN –Recommended Types: Laser Optimized Multimode, Singlemode, or Hybrid Copper Cabling –Horizontal Cabling of 100 meters or less –Recommended Types: Category 6, Augmented Category 6

23 Choosing the Correct Cabling Type Category 6 –TIA-942 standard recommends Cat 6 as the minimum standard for Data Center installations –Limited support for 10GBase-T (37 meters unmitigated per TSB-155) Augmented Category 6 –Not a ratified standard yet, although draft standards are available and IEEE 802.3an is ratified –Full support for 10GBase-T to 100 meters in standard operation and 30 meters for Short-Reach mode Laser Optimized Multimode Fiber –Recognized by TIA and IEEE 802.3ae –Full support 10 Gigabit Ethernet over fiber for 300 meters or more depending on grade of fiber

24 Greatest Myths regarding 10GBase-T Cabling Myth: You can only run 10GBase-T on Augmented Cat 6 Reality: 10GBase-T will run on Cat 6 for limited distances Myth: Alien Crosstalk is the only concern in 10GBase-T transmission Reality: All electrical parameters are a concern, especially attenuation and return loss

25 Greatest Myths regarding 10GBase-T Cabling Myth: You have to use shielded cable to run 10GBase-T Reality: Unshielded designs can easily run 10GBase-T and overcome all electrical issues associated with running 10 Gig

26 TIA-942 Data Center Standard TIA Telecommunications Infrastructure Standard for Data Centers Site selection and sizing Cabling infrastructure administration Architectural and structural considerations Security and fire protection Electrical, grounding and mechanical systems Application distance limitations Access-provider coordination and demarcation

27 TIA-942 Data Center Model Backbone Cabling Horizontal Cabling

28 Interconnection vs. Cross-Connect in the LAN

29 Migration of Data Center Cabling Design Generation 1: Direct Connection –Difficult to Scale –Done incorrectly impacts thermal performance Server Switch

30 Migration of Data Center Cabling Design Generation 2: Interconnect –Prevalent architecture in LAN, scales adequately in smaller Data Centers –For larger, Tier III and IV Data Centers design limits scalability Switch Server

31 Migration of Data Center Cabling Design Generation 3: Cross-Connect –The optimum solution for enhanced cable management and reliability –Allows for scalability (addition of equipment) by only changing patch cords Server Switch

32 Ideally a Data Center should not only be designed and installed in a tidy user friendly manner But also be maintained to the same level of installed manageability! When it’s done right the first time!

33 Centralized Fiber Management in the Data Center

34 Fiber Termination Options Field Term, Splice or MPO/MTP Field Termination –Allows polishing of fiber in the field Splicing –Fusion splicing of factory terminated fiber pigtails MPO Solutions –Allow fast termination with factory polishing

35 Data Center Design Observations Data Centers are fundamentally different from typical LANs in that they require… –Different Architecture –Different Level of Reliability –Different Standards –Different Cable Management Requirements –Different Structured Cabling Solution

36 The Data Center Design Dilemma: Density vs. Manageability and Reliability Fundamentally, you cannot use the same structured cabling products originally designed for low density LANs and expect them to perform to the level required in a Data Center

37 The Data Center Design Dilemma: Density vs. Manageability and Reliability Direct Connect Cross Connect

38 The Solution: Cabling Systems Designed Specifically for Data Centers Solves both the Density and the Management issues Manages Ethernet cables (copper or fiber) Manages cables from both Switches and patch panels Designed to meet the Four Fundamentals of Fiber Cable Management

39 ADC TrueNet Data Center Solutions Summary Data Centers are fundamentally different than LANs Structured Cabling can positively or negatively effect Data Center reliability Proper design, adherence to standards, and the right product solutions will result in an optimal Data Center design Learn more at

- Are you an infrastructure designer or specifier? Would you like dedicated support and design tools free of charge with no obligation? –Join PACE - ADC’s Collaborative Program for Professional Architects, Consultants and Engineers For more information or to join today simply visit: adc.com/partners or contact us at: