Electric “Grid” Savings and Non-Electric Benefits for Residential HVAC-affected UES Measures Regional Technical Forum March 20, 2013.

Slides:



Advertisements
Similar presentations
New MT Houses with Ground Source Heat Pumps Energy Savings and Costs June 2 nd, 2009 Regional Technical Forum 1.
Advertisements

Modeling Multifamily Heating Energy Use Can SEEM be used, or do we need to use a multi- zone model? Regional Technical Forum January 17, 2011.
1 Residential Weatherization Calculator Deriving Realistic Savings Estimates for the “Uninsulated” House.
SEEM Calibration: Revisited Revising the regression to use continuous heat loss variable Regional Technical Forum December 17, 2013.
New Construction Calibration Research Results and Request for Decision Regional Technical Forum March 18, 2014.
Residential Single Family Weatherization and HVAC Measures Progress Reports: 1.Estimating Electric and Supplemental Fuels Savings 2.Estimating Value of.
The Saga Continues: Measure Interactions for Residential HVAC and Wx measures Regional Technical Forum April 23, 2014.
Ductless Heat Pumps in Manufactured Homes with Zonal Electric Resistance Heat Adam Hadley Regional Technical Forum February 18, 2015.
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
Deeming Savings for Ductless Heat Pumps in Manufactured Homes Regional Technical Forum January 4 th, 2011.
Electric “Grid” Savings and Non-Electric Benefits for Residential HVAC-effected UES Measures Regional Technical Forum March 20, 2013.
Prescriptive Duct Sealing UES Measure Proposal Regional Technical Forum Subcommittee July 8, 2013.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update March 17, 2015.
SEEM 94 Calibration to Single Family RBSA Data Regional Technical Forum January 23, 2013 Analysis Performed ByAdam Hadley Cursory Reviews By Tom Eckman,
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update May 12, 2015.
BPA Pre-Pilot, Monmouth  14 homes with installed DHP, single zone, single compressor.  11 Monmouth, 2 Moses Lake, 1 Tacoma  Savings.
SEEM Tool Overview Regional Technical Forum Member Orientation January 22, 2013.
DHP for Houses with Electric FAF Provisional UES Measure Proposal Adam Hadley, Ben Hannas, Bob Davis Regional Technical Forum January 21, 2015.
1Managed by UT-Battelle for the Department of Energy Michael Blasnik M Blasnik & Associates Greg Dalhoff Dalhoff Associates, LLC David Carroll APPRISE.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential Appliance Measure Updates Danielle Gidding Bonneville Power Administration.
Northwest Power and Conservation Council 6 th Plan Conservation Resource Supply Curve Workshop on Data & Assumption Overview of Council Resource Analysis.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Creating a DHP UES Measure Ecotope, Inc. July 16, 2013.
SEEM 94 Calibration to RBSA Data Progress Report on Phase 2 (Digging a Little Deeper) Subcommittee Regional Technical Forum March 20, 2013.
Guidelines for the Development and Maintenance of RTF- Approved Measure Savings Estimates December 7, 2010 Regional Technical Forum Presented by: Michael.
DHP for Houses with Electric FAF Research Plan: Revisions Adam Hadley, Ben Hannas, Bob Davis, My Ton R&E Subcommittee February 25, 2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Northwest Ductless Heat Pump Pilot Project Impact & Process Evaluation: Billing Analysis Ecotope, Inc. February.
Delivery Verification Jennifer Anziano Regional Technical Forum March 17, 2015.
Standard Information Workbook (SIW) Update Proposal Regional Technical Forum May 13, 2014.
Heat Pump Water Heater Request for Feedback on a proposal to add UES measures with a “Retail – any installation location” delivery mechanism Regional Technical.
QC Follow-up for Single Family SEEM Calibration, HVAC UES Measures, and Weatherization Measures Adam Hadley Regional Technical Forum May 12, 2015.
SEEM Calibration: Phase-2 Adjustments for Failed VBDD Fits Regional Technical Forum August 12, 2014.
DHP Supplemental Fuel Screen Subcommittee Meeting Regional Technical Forum February 12, 2014.
Analysis of Weatherization Measures Options for Savings Methodology and Presentation of Costs from 6 th Plan Regional Technical Forum May 4 th, 2010.
SEEM Input Variables for RBSA Calibration Manufactured Homes RTF Subcommittee on SEEM MH Calibration May 9, 2013.
Path for Multi-Family (MF) Weatherization and NC Measures Christian Douglass 8/18/2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Follow-up from August RTF.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum September 17, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum August 20, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum November 19, 2013.
SEEM Calibration: Phase-2 Adjustments for Failed VBDD Fits RTF Calibration Subcommittee July 31, 2014.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE DHP Costs & NEBs Ecotope, Inc. August 20, 2013.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE DHP UES Key Issues & Decisions Ecotope, Inc. May 21, 2013.
ProCost Version 3 Christian Douglass, Ryan Firestone, Charlie Grist
Goodbye, “Last Measure In” Hello, “Option X”? Staff Proposal for how to deal with the last measure in conundrum Regional Technical Forum October 15, 2013.
Review of the New England “Mini-Pilot” DHP Evaluation Why we ignore this study.
Evaluation of Wood Smoke Quantification and Attribution RTF PAC October 17, 2014.
SEEM Calibration for Manufactured Housing Regional Technical Forum December 13, 2011 Analysis Performed ByAdam Hadley Cursory Reviews ByTom Eckman, Ben.
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
Analysis of Weatherization Measures Savings Methodology and Costs: Updated from 6 th Plan Regional Technical Forum June 1 st, 2010.
Wood Smoke Study: RTF Report Technical Subcommittee Meeting September 26 th,
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum March 18, 2014.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum October 16, 2013.
Regional Technical Forum Future Funding Discussion March 19, 2014 RTF PAC Presentation.
Refrigerator Recycling UES Measure Subcommittee Adam Hadley Subcommittee of the RTF September 1, 2015.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
ENERGY STAR and Eco-Rated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Multifamily Homes: Calibration Update Regional Technical Forum December 8 th, 2015.
New Construction Calibration Preliminary Research and a Request for Guidance on Issues Raised in December Regional Technical Forum January 22, 2013.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
Where did it go? Lost savings found in real-world data SEEM Calibration for the Northwest Power and Conservation Council’s Regional Technical Forum (RTF)
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
Extra Slides to Accompany: SEEM 94 Calibration to Single Family RBSA Data Analysis and proposed actions Regional Technical Forum May 21, 2013.
Wood Smoke: Monetizing Health Benefits Regional Technical Forum August 23, 2013.
RTF Management Update Jennifer Anziano Regional Technical Forum March 17, 2015.
RTF Management Updates Jennifer Light Regional Technical Forum February 17, 2016.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Research Strategy: Residential Ductless Heat Pumps Research and Evaluation Subcommittee Christian Douglass and Josh Rushton January 8, 2016.
Presentation transcript:

Electric “Grid” Savings and Non-Electric Benefits for Residential HVAC-affected UES Measures Regional Technical Forum March 20, 2013

Overview For residential measures that effect heating and cooling usage: – RTF electric savings estimates should be reliable from an electric utility planning perspective (i.e. “Grid Savings”). Measured Savings are considered reliable. – There appear to be non-electric benefits the RTF can account for in its cost-effectiveness tests. Measured Savings < Engineering Savings. Primary questions: – Is the following proposed framework for “Grid Savings” and NEB’s correct? – How should RTF monetize non-electric benefits? 2

Framework 3

4 Engineering Savings (“The Whole Pie”) Definition: Estimated electric energy savings based on physics (lower UA = lower heating energy use). Example: Engineering model assumes 100% electrically heated houses and “typical” usage.

5 Measured Electric Savings (a.k.a “Grid Savings”) Definition: Electric energy savings for the population, measured through submetering or billing studies.

6 Non-Electric Benefits Definition: Portion of the Engineering Savings that apply to the following two non-electric components: Fuel Savings (Non-electric) -Example: Occupant stops using their wood stove in the efficient-case, in favor of the electric heating system. -Example: Occupant continues using their wood stove, but uses less wood because of the lower house heat loss. Increased Comfort (a.k.a. “Takeback”) -Example: Occupants operate their house at a warmer (winter) and cooler (summer) temperature in the efficient- case.

7 Engineering Correction Definition: Adjustment to engineering savings to account for non-typical usage. Example: Partial Occupancy; occupants are away for the winter months and leave t-stat at a very low setting.

8 Not to Scale – These will vary by program, region, modeling method, etc. – Some slices of the pie could be zero (or negative).

Long-Term Effects Non-Electric Fuel usage and “Comfort Level” varies depending on economic conditions and other factors. – Billing analyses & metering studies are “snapshots in time”. For the same measure, the NEB’s could vary year-to-year. – Note how this could change Measured Electric Savings – Engineering Savings would see less change, if any. 9 We’re not likely to solve this issue today. Instead, since the data sources will vary, corrections for “long-term effects” will need to be made on a measure-by-measure basis per RTF judgment.

Uncertainty Engineering Savings and Measured Electric Savings carry with them uncertainty – If the uncertainty is large, it could (and should) call into question including Non-Electric Benefits. For Example: 10 We’re not likely to solve this issue today. Instead, since the data sources will vary, decisions on including Non-Electric Benefits will need to be made on a measure-by-measure basis per RTF judgment.

Examples DHP Weatherization 11

IDItemSource/MethodHeating Zone 1 Heating Zone 3 A Engineering Savings Metering Study 4000 IDItemSource/MethodHeating Zone 1 Heating Zone 3 A Engineering Savings Metering Study 4000 B Measured Electric Savings Billing StudyAll Sites IDItemSource/MethodHeating Zone 1 Heating Zone 3 A Engineering Savings Metering Study 4000 B Measured Electric Savings Billing StudyAll Sites C Measured Electric Savings + Non-electric Fuel Savings Billing Study Filtered for No Supplemental Fuel IDItemSource/MethodHeating Zone 1 Heating Zone 3 A Engineering Savings Metering Study 4000 B Measured Electric Savings Billing StudyAll Sites C Measured Electric Savings + Non-electric Fuel Savings Billing Study Filtered for No Supplemental Fuel Non- electric Benefits Fuel SavingsC – B IDItemSource/MethodHeating Zone 1 Heating Zone 3 A Engineering Savings Metering Study 4000 B Measured Electric Savings Billing StudyAll Sites C Measured Electric Savings + Non-electric Fuel Savings Billing Study Filtered for No Supplemental Fuel Non- electric Benefits Fuel SavingsC – B Increased ComfortA - C Using DHP as an Example 12 Grid Savings (kWh) Non-Electric Benefits (need to monetize) Notes: 1. All values in kWh/yr. 2. Values and method are for example only – we’ll discuss DHP measure specifics later. 3. Engineering Correction is assumed to be 0 kWh/yr based on design of Metering Study to include randomly selected sites.

IDItemSource/Method AEngineering Savings SEEM runs calibrated to RBSA “post” t-stat setting; houses with “good” electric & gas bills only T-stat: 68°F pre & post BEngineering Savings – Increased Comfort SEEM runs calibrated to RBSA “pre” and “post” t-stat setting; houses with “good” electric & gas bills only Tstat: 65°F pre 68°F post CEngineering Correction Rough estimate based on RBSA data % of houses with electric & gas heat only and with poor PRISM R-square DNEB Fuel Savings Rough estimate based on 2 sources i. RBSA: % of heat supplied by “other” fuels in electric heat homes ii. DHP: % of fuel savings in the DHP measure Measured Electric SavingsB – C – D Non Electric Benefits Fuel SavingsD IDItemSource/Method AEngineering Savings SEEM runs calibrated to RBSA “post” t-stat setting; houses with “good” electric & gas bills only T-stat: 68°F pre & post BEngineering Savings – Increased Comfort SEEM runs calibrated to RBSA “pre” and “post” t-stat setting; houses with “good” electric & gas bills only Tstat: 65°F pre 68°F post IDItemSource/Method AEngineering Savings SEEM runs calibrated to RBSA “post” t-stat setting; houses with “good” electric & gas bills only T-stat: 68°F pre & post BEngineering Savings – Increased Comfort SEEM runs calibrated to RBSA “pre” and “post” t-stat setting; houses with “good” electric & gas bills only Tstat: 65°F pre 68°F post CEngineering Correction Rough estimate based on RBSA data % of houses with electric & gas heat only and with poor PRISM R-square IDItemSource/Method AEngineering Savings SEEM runs calibrated to RBSA “post” t-stat setting; houses with “good” electric & gas bills only T-stat: 68°F pre & post BEngineering Savings – Increased Comfort SEEM runs calibrated to RBSA “pre” and “post” t-stat setting; houses with “good” electric & gas bills only Tstat: 65°F pre 68°F post CEngineering Correction Rough estimate based on RBSA data % of houses with electric & gas heat only and with poor PRISM R-square DNEB Fuel Savings Rough estimate based on 2 sources i. RBSA: % of heat supplied by “other” fuels in electric heat homes ii. DHP: % of fuel savings in the DHP measure IDItemSource/Method AEngineering Savings SEEM runs calibrated to RBSA “post” t-stat setting; houses with “good” electric & gas bills only T-stat: 68°F pre & post BEngineering Savings – Increased Comfort SEEM runs calibrated to RBSA “pre” and “post” t-stat setting; houses with “good” electric & gas bills only Tstat: 65°F pre 68°F post CEngineering Correction Rough estimate based on RBSA data % of houses with electric & gas heat only and with poor PRISM R-square DNEB Fuel Savings Rough estimate based on 2 sources i. RBSA: % of heat supplied by “other” fuels in electric heat homes ii. DHP: % of fuel savings in the DHP measure Measured Electric SavingsB – C – D Non Electric Benefits Fuel SavingsD Increased ComfortA – B IDItemSource/Method AEngineering Savings SEEM runs calibrated to RBSA “post” t-stat setting; houses with “good” electric & gas bills only T-stat: 68°F pre & post BEngineering Savings – Increased Comfort SEEM runs calibrated to RBSA “pre” and “post” t-stat setting; houses with “good” electric & gas bills only Tstat: 65°F pre 68°F post CEngineering Correction Rough estimate based on RBSA data % of houses with electric & gas heat only and with poor PRISM R-square DNEB Fuel Savings Rough estimate based on 2 sources i. RBSA: % of heat supplied by “other” fuels in electric heat homes ii. DHP: % of fuel savings in the DHP measure Measured Electric SavingsB – C – D IDItemSource/Method AEngineering Savings SEEM runs calibrated to RBSA “post” t-stat setting; houses with “good” electric & gas bills only T-stat: 68°F pre & post Using Weatherization as an Example 13 Note: This method is shown for illustration of the framework only; it has not been reviewed by the RTF and may not meet the RTF’s guidelines.

Next Steps In both examples, Non-Electric Benefits are quantified in kWh’s. We need to then monetize the Non-Electric Benefits – (assuming they’re not zero) 14

ProCost Inputs 15 Data Source(s) kWh/$ Conversion

How to Monetize the Non-Electric benefits? Option 1: Convert each Non-Electric Benefits into Dollars – Non-Electric Fuel Savings Convert kWh savings to cords of wood savings to dollar savings – Issue: Many assumptions needed (Btu/cord; efficiency of stove, $/cord, pollution benefit, etc.) – Increased Comfort Value at the cost of electricity – Occupant chose to pay for more electricity, so value of comfort should be at least equivalent to the price of electricity, if not more. – Issue: Split between Increased Comfort and Non-Electric Fuel Savings is unknown. Option 2: Value both Non-Electric Benefits at the cost of electricity – Same logic as for Increased Comfort above – The “many assumptions” for converting kWh savings to cords of wood to dollar savings would likely be “calibrated” to this value. (Value of wood calibrated to be no lower than value of electricity.) Issue: Use Retail or Wholesale cost of electricity? – Guidelines specify avoided costs (wholesale). – Which is a better proxy for consumer economic value of non-electric fuel savings? increased comfort? 16

Decisions 1.Adopt the presented framework for quantifying Measured Electric Savings and NEB’s? – Current Framework NEB’s have not been (explicitly) included in the cost-effectiveness test. Measured Electric Savings have sometimes included NEB’s. – “Long-term” savings. – Proposed Framework Quantify Measured Electric Savings and NEB’s according to framework. – Any decision to adjust values for “long-term effects” or uncertainty would be explicit and measure-specific. Include NEB’s in cost-effectiveness test. 2.How to Monetize NEB’s? – Which Option? Option 1: Convert each Non-Electric Benefits into Dollars (wood & electricity); or Option 2: Value both Non-Electric Benefits at the cost of electricity – Which value of electricity? Retail? Wholesale? – Other Options 17

Background Slides 18

Related slides from the January 2014 RTF Meeting (“SEEM 94 Calibration to RBSA Data” Presentation) 19