ADVANCED SPECTRAL ANALYSIS OF OUT-OF-STEP OPERATION OF SYNCHRONOUS MACHINES Zbigniew Leonowicz BSI Riken, ABSP Lab. Wako-shi, Saitama, Japan

Slides:



Advertisements
Similar presentations
The stator winding are supplied with balanced three-phase AC voltage, which produce induced voltage in the rotor windings. It is possible to arrange the.
Advertisements

ENERGY CONVERSION ONE (Course 25741)
Synchronous Machines (AC Generators)
Air Force Technical Applications Center 1 Subspace Based Three- Component Array Processing Gregory Wagner Nuclear Treaty Monitoring Geophysics Division.
Induction Motor •Why induction motor (IM)?
ELECTRIC DRIVES Ion Boldea S.A.Nasar 1998 Electric Drives.
Machine Transformations
Chapter 4 Synchronous Generators
Two-pole,3-phase,wye-connected,salient-pole synchronous machine
ECE Electric Drives Topic 4: Modeling of Induction Motor using qd0 Transformations Spring 2004.
SYNCHRONOUS MACHINES SUBMITTED BY: Ms. APOORVA KANTHWAL
Synchronous Machines.
Three-Phase AC machines
Topic 5: Dynamic Simulation of Induction Motor Spring 2004 ECE Electric Drives.
Pontifical Catholic University of the Rio Grande do Sul Brazil Applying Artificial Neural Networks to Energy Quality Measurement Fernando Soares dos Reis.
Synchronous Motors and Generators
Three-Phase Induction Motor Stator. Three-Phase Alternating Current.
Steady-State Sinusoidal Analysis
SEE 3433 MESIN ELEKTRIK SYNCHRONOUS MACHINES Basic principles.
Generator Protection. Amount of Protection Rated power of the generator Ratio of its capacity to the total capacity of the system Configuration of the.
AP Physics C Montwood High School R. Casao
Synchronous Generator
Three-Phase AC machines
Zbigniew LEONOWICZ, Tadeusz LOBOS Wroclaw University of Technology Wroclaw University of Technology, Poland International Conference.
Department of Electrical and Computer Engineering
Current Contribution from Wind Plant for a System Fault Working Group C17 May 2010 Meeting.
Chapter 35.
Unit 5 An Introduction to Mechanical Engineering: Part One Electrical and Electronic Systems 5.2 – key points Kirchhoff postulated that in any circuit.
5.1 INTRODUCTION TO POLYPHASE SYNCHRONOUS MACHINES
Chapter 5 Steady-State Sinusoidal Analysis. 1. Identify the frequency, angular frequency, peak value, rms value, and phase of a sinusoidal signal. 2.
Induction Motors.
(C) 2006, SUCCESS by DESIGN Surge Values at Each Test Stator surged to fault Indicates decrease in dielectric strength following each test. Applied Surge.
Power Factor Improvement Lecture 9. Normally, the power factor of the whole load on a large generating station is in the region of 0·8 to 0·9. However,
AGC DSP AGC DSP Professor A G Constantinides©1 Eigenvector-based Methods A very common problem in spectral estimation is concerned with the extraction.
NEW POWER QUALITY INDICES Zbigniew LEONOWICZ Department of Electrical Engineering Wroclaw University of Technology, Poland The Seventh IASTED International.
Chapter 5. Synchronous Machines.
CCN COMPLEX COMPUTING NETWORKS1 This research has been supported in part by European Commission FP6 IYTE-Wireless Project (Contract No: )
STARTING OF 3PH INDUCTION MOTOR
EET 221 Synchronous Machines Rafiqi.
Motors and Generators.
Electric motors KON-C2004 Mechatronics Basics Tapio Lantela, Nov 2nd, 2015.
Z bigniew Leonowicz, Wroclaw University of Technology Z bigniew Leonowicz, Wroclaw University of Technology, Poland XXIX  IC-SPETO.
Electric Generator Done by Abdullah Al-Hulaimi ID# For Dr shwahdi 10 May 2005.
Magnetic field due to an electric current
Analysis of Traction System Time-Varying Signals using ESPRIT Subspace Spectrum Estimation Method Z. Leonowicz, T. Lobos
BASIC ELECTRICAL TECHNOLOGY DET 211/3
EFFECTS OF VOLTAGE IMBALANCE ON 3-PHASE INDUCTION MOTORS DESIGN TEAM 3.
Induction motor National Research Tomsk Polytechnic University Student: R.N.Kalimbekov Group 5GM42 Teacher: O.S.Kachin Tomsk 2015.
1 AC Circuit Theory. 2 Sinusoidal AC Voltage Waveform: The path traced by a quantity, such as voltage, plotted as a function of some variable such as.
Presentation of ELECTRIC MACHINES Title: Single Phase Motors By: Rahul Khanna{ }EC3 rd Sem Guided By: Prof. Ravi Patel.
Synchronous Motors Introduction An alternator may operate as a motor by connecting its armature winding to a 3-phase supply. It is then called a synchronous.
Lesson 12a: Three Phase Induction Motors
Hafizism february 2007 EMT462 Electrical System Technology LECTURE V mohd hafiz ismail level II jejawi.
SYNCHRONOUS GENERATOR
SINGLE-PHASE INDUCTION MOTOR
MEASUREMENT OF IEC GROUPS AND SUBGROUPS USING ADVANCED SPECTRUM ESTIMATION METHODS A. Bracale, G. Carpinelli, Z. Leonowicz, T. Lobos, J. Rezmer.
高等電機機械 報告者:朱振源 指導老師:秦純 教授.
Lesson 16: Asynchronous Generators/Induction Generators
Principle of Operation
Wind turbine technology
Presentation of ELECTRIC MACHINES Title: Single Phase Motors By: Rahul Khanna{ }EC3 rd Sem Guided By: Prof. Ravi Patel.
Advanced Power Systems
Energy Conversion and Transport George G. Karady & Keith Holbert
INDUCTION MOTOR steady-state model (squirrel cage)
Energy Conversion and Transport George G. Karady & Keith Holbert
SYNCHRONOUS MACHINES Basic principles
Utilisation of Electrical Energy
Principle of Operation
Electric Machine Design Course
Electric Machine Design Course
Presentation transcript:

ADVANCED SPECTRAL ANALYSIS OF OUT-OF-STEP OPERATION OF SYNCHRONOUS MACHINES Zbigniew Leonowicz BSI Riken, ABSP Lab. Wako-shi, Saitama, Japan Introduction The out-of step operation conditions (loss of synchronism) of a synchronous machine may occur as a result of a power system three-phase fault. Fault The power output of the machine is reduced as it is supplying a mainly inductive circuit. However, the input power to the generator from the turbine has not time to change during the short time of the fault and the rotor begin to gain speed to store the excess energy. If the fault persists long enough, the rotor angle will increase continuously and synchronism will be lost. The current waveforms in the stator winding contain three main components, which frequencies depend on the rotor slip. At the beginning of an asynchronous running, differences between the frequencies are small. Therefore, the identification of the components is difficult. Detection The complex impedance measured at the machine terminals is compared with a proper characteristic on the complex impedance plane, to detect the asynchronous operation. The other methods used for identification of out-of-step operations are based on the rate of change of apparent resistance augmentation. The equal area criterion The observations of phase differences between sub-stations Applications of neural networks. At the beginning of an asynchronous running, differences between the frequencies are small and the identification of the components is difficult. Use of FFT for spectral analysis Several performance limitations of the FFT: Frequency resolution – ability to distinguish the spectral responses of two or more signals. Windowing of the data – leakage in the frequency domain. Current Waveforms in the Stator Windings If the machine running in parallel with other devices is disturbed from its synchronous-state conditions, the rotor winding and the stator winding fluxes rotate with different velocities. The angular velocities of the fluxes are equal to the angular frequencies of the alternating components of the rotor winding current. The angular frequencies of the components are: and. IFAC Symposium on Power Plants & Power Systems, June 8-12, 2003, SEOUL, KOREA Fault Operation of Synchronous Generator Generator data: salient-pole synchronous generator: Nominal power 200MVA, nominal voltage V, nominal frequency 50 Hz. Modeled power system: Fault Duration 100 ms T= 1s T=4s Fault Duration 250 ms Conclusions When the synchronous running of a synchronous machine is lost, a current in the stator winding can be resolved into two or three components with different frequencies depending on the rotor slip. At the beginning of an asynchronous running, differences between the frequencies are small. For identification of the asynchronous operation, the frequencies of the current components are estimated. The appearance of additional current frequency components can be used as indicator of out-of-step operation of a synchronous machine. Decrease of the frequency differences of the detected current components over the time indicates that the generator is leaving the out-of-step state. Because of very small differences between the frequencies of the components, high- resolution spectrum estimation methods are needed. Therefore, subspace methods have been applied. Extensive investigations confirm the validity of the proposed method. Tadeusz Lobos Wroclaw University of Technology Wroclaw, Poland Subspace Methods The subspace frequency estimation methods rely on the property that the noise subspace eigenvectors of a Autocorrelation Matrix are orthogonal to the eigenvectors spanning the signal space. The model of the signal in this case is a sum of random sinusoids in the background of noise of a known covariance function. The eigenvectors spanning the noise space are the ones whose eigenvalues are the smallest and equal to the noise power.MUSIC The correlation matrix of the signal vector is N-M smallest eigenvalues of the correlation matrix (matrix dimension N>M+1) correspond to the noise subspace and M largest correspond to the signal subspace. The matrices of eigenvectors are defined: E noise can be used to form a projection matrix P X for the noise subspace The MUSIC pseudospectrum is defined as: and it exhibits sharp peaks at the signal frequencies where w=s i Hz51.27 Hz48.83 Hz50.68 Hz