High Resolution PET Instruments for Prostate Imaging Neal Clinthorne 1, Stan Majewski 2, Karol Brzezinski 3, Sam S. Huh 4, Jessie Carr 4, Zhewei Chen 4,

Slides:



Advertisements
Similar presentations
Study of plastic scintillators for fast neutron measurements
Advertisements

PET Design: Simulation Studies using GEANT4 and GATE - Status Report - Martin Göttlich DESY.
Recent news about SiPM based applications R&D in DESY Nicola D’Ascenzo University of Hamburg - DESY.
Chapter 8 Planar Scintigaraphy
Andrej Studen, Karol Brzezinski, Enrico Chesi, Vladimir Cindro, Neal H. Clinthorne, Milan Grkovski, Borut Grošičar, Klaus Honscheid, S. S. Huh, Harris.
DFNA-Ilie Cruceru PERSPECTIVES FOR A POSITRON EMISSION TOMOGRAPHY (PET) PLANT BASED ON RESISITIVE PLATE COUNTER (RPC) Ilie Cruceru, Mihai Petrovici, Florin.
Elliot Mylott, Ryan Klepetka, Justin C. Dunlap and Ralf Widenhorn
Computed Tomography III
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
Simulation System for Emission Tomography (SimSET): using the new block detector feature. Robert L. Harrison, William C. J. Hunter, Steven B. Gillispie,
tomos = slice, graphein = to write
VALENCIA b mass effects at the Z 0 peak from 3 and 4 jet events P. Bambade, M.J. Costa, J. Fuster and P. Tortosa b mass effects have been.
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
8/18/2015G.A. Fornaro Characterization of diffractive optical elements for improving the performance of an endoscopic TOF- PET detector head Student: G.
M. D. A NDERSON Cancer Center Magnetic Resonance Imaging: 4.7 T, 40 cm Bruker Biospec James A Bankson, Ph.D. and John D Hazle, Ph.D. Small Animal Cancer.
An intra-operative beta probe for brain tumor surgery Interfaces Physique Biologie group, University of Paris XI S. Bonzom, L. Ménard, M.A Duval, S. Pitre,
High spatial resolution measurement of depth-of-interaction of a PET LSO crystal Aliz Simon a László Balkay b, István Chalupa b, Gábor Kalinka a, András.
Very High Resolution Small Animal PET Don J. Burdette Department of Physics.
RAD2012, Nis, Serbia Positron Detector for radiochemistry on chip applications R. Duane, N. Vasović, P. LeCoz, N. Pavlov 1, C. Jackson 1,
Medical Image Analysis Medical Imaging Modalities: X-Ray Imaging Figures come from the textbook: Medical Image Analysis, Second Edition, by Atam P. Dhawan,
May 2015ECFA meeting1 Spin-off technologies for cancer diagnosis J. Varela, LIP Lisbon ECFA meeting, Coimbra, 15 May, 2015.
Dan Spratt, MD Department of Radiation Oncology Neuroendocrine Prostate Cancer: FDG-PET and Targeted Molecular Imaging.
Muscle Volume Analysis 3D reconstruction allows for accurate volume calculation Provides methods for monitoring disease progression Measure muscle atrophy.
Development of New Detectors for PET Imaging at BNL DOE/JLAB Meeting Bethesda, MD May 20, 2004 Craig Woody Physics Dept Brookhaven National Lab RatCAPBeta.
F. Garibaldi 1,, for TOPEM collaboration TOPEM: a PET TOF endorectal probe, compatible with MRI for diagnosis and follow up of prostate cancer endorectal.
Fundamental Limits of Positron Emission Tomography
Response of the sensors to different doses from tests in Israel Radiotherapy is used as a treatment in around 50% of cancer cases in the UK. Predominantly,
Innovative Method to Measure Solids Circulation in Spouted Fluidized Beds 2009 AIChE National Meeting Nashville, TN November 9, 2009.
First Results from a Test Bench for Very High Resolution Small Animal PET Using Solid-State Detectors Klaus Honscheid for The CIMA Collaboration The Ohio.
Interaction ionizing radiation with biological tissue. Basic dosimetry.
Single Photon Emission Computed Tomography
HEALTH Novel MR-compatible PET detectors for simultaneous PET/MRI imaging FP7-HEALTH-2009-single-stage The focus should be to develop novel.
Advisor Client Justin Williams, PhD Department of BiomedicalEngineering University of Wisconsin-Madison Fredrick Kelcz, PhD, MD Department of Radiology.
Nuclear Medicine: Planar Imaging and the Gamma Camera Katrina Cockburn Nuclear Medicine Physicist.
Professor Brian F Hutton Institute of Nuclear Medicine University College London Emission Tomography Principles and Reconstruction.
Li HAN and Neal H. Clinthorne University of Michigan, Ann Arbor, MI, USA Performance comparison and system modeling of a Compton medical imaging system.
Where do our data come from? Positron Emission Tomography (PET)
Introduction to Modern Medical Imaging
16. January 2007Status Report On Compton Imaging Projects 1 Status Of Compton Imaging Projects Carried Out In The CIMA Collaboration HPD Brain PET Meeting.
Enhancing InBeam PET with single Photon (Compton) Detection CERN September 2nd 2008 VALENCIA GROUP, IFIMED José M. Benlloch (PET hardware, speaker) José.
Imaging HIFU Lesions Using Ultrasound Andrew Draudt and Robin Cleveland Department of Aerospace and Mechanical Engineering, Boston University, Boston,
Rebecca Barrett CRYSTAL LAB. PET Detects gamma rays Interact with the crystals and release photons Smaller the crystal, the less uncertainty.
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
Prostate probe with SPECT technique NSS – MIC November 5 - KnoxvilleF. Garibaldi- INFN – Roma1 – gr. Coll. ISS  the medical problem  the proposal.
Improved Hybrid PET Imaging Using Variable Focal Length Fan-Slat Collimators Thomas C. Rust and Dan J. Kadrmas, Ph.D. Medical Imaging Research Laboratory.
P. Lecoq CERN February SiPM Workshop, CERN, February, 2011 New Approaches in Scintillation Detectors in the Context of HEP Calorimetry and.
1 Nuclear Medicine SPECT and PET. 2 a good book! SR Cherry, JA Sorenson, ME Phelps Physics in Nuclear Medicine Saunders, 2012.
Lecture 12  Last Week Summary  Sources of Image Degradation  Quality Control  The Sinogram  Introduction to Image Processing.
F. Garibaldi 1,, F. Cusanno 1), S. Majewski 3), N. Clinthorne, P. Musico 4),…………………………. TOPEM: a PET TOF probe, compatible with MRI and MRS for diagnosis.
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
Thickness of CZT detector 110 MeV140 MeV DETECTOR A (1 mm CZT + 5 mm CZT) DETECTOR B (1 mm CZT + 10 mm CZT) DETECTOR C (1 mm CZT + 15 mm CZT) A. Generation.
Presentation of Master of medical and imagery physics Rajaa Cherkaoui El Moursli, Mohammed V – Agdal University, Rabat, Morocco Hassan II Academy of Sciences.
By David Tse Mentor: Andreas H. Hielscher, Ph.D Columbia University Biomedical Engineering Department 500 West 120th Street ET351 Mudd Bldg., MC8904 New.
Positron Emission Tomography (PET) scans allow for functional imaging of the body’s metabolism, making it an effective tool for locating cancerous tumors.
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
Journal of Nuclear Cardiology | Official Journal of the American Society of Nuclear Cardiology The high matrix acquisition technique for imaging of atherosclerotic.
PET Imaging Positron Emission Tomography
JESÚS SILVA-RODRÍGUEZ, PABLO AGUIAR, INÉS DOMÍNGUEZ-PRADO, MICHEL HERRANZ, ÁLVARO RUIBAL 18F-Choline: Is shine-through effect an issue for prostate SUV.
Prostate probe with SPECT technique NSS – MIC November 5 - KnoxvilleF. Garibaldi- INFN – Roma1 – gr. Coll. ISS  the medical problem  the proposal.
Simulations in Medical Physics Y. TOUFIQUE*, R.CHERKAOUI EL MOURSLI*, M.KACI**, G.AMOROS**, *Université Mohammed V –Agdal, Faculté des Sciences de Rabat,
Positron emission tomography without image reconstruction
P.E.T. Positron Emission Tomography
PET Activities at UiO NFR Review E. Bolle*
Advances in Imaging Instrumentation for Nuclear Cardiology
Image quality and Performance Characteristics
Image quality and Performance Characteristics
Summary of the Compton-PET project
Development of a High Precision Axial 3-D PET for Brain Imaging
Imaging the event-prone coronary artery plaque
Application of Nuclear Physics
Presentation transcript:

High Resolution PET Instruments for Prostate Imaging Neal Clinthorne 1, Stan Majewski 2, Karol Brzezinski 3, Sam S. Huh 4, Jessie Carr 4, Zhewei Chen 4, Emma Salomonsson 4, Aashay Yande 4 1 Dept. Radiology University of Michigan, Ann Arbor, MI 2 Center for Advanced Imaging, Dept. Radiology, West Virginia University, Morgantown, WV 3 IFIC/CSIC University of Valencia, Spain, 4 Dept. Biomedical Engineering, University of Michigan, Ann Arbor, MI Probe Sensitivity and Anticipated Performance Detector Technology Background Resolution v. Noise Tradeoff One way to improve resolution is to use an image reconstruction method that models—and then undoes—blurring inherent in the measurements. While this can work to some extent, it inevitably increases the level of noise in reconstructed images. There is an intrinsic “resolution-noise” tradeoff associated with each imaging system. Shown at right are resolution-noise tradeoff curves for three PET scanners having different intrinsic resolution (4mm, 6mm, and 8mm FWHM). Notice how quickly the noise level rises as one attempts to work at resolution better than supported by the intrinsic resolution. Better Resolution Through Better Measurements This work was partially supported by the U.S. Army Medical Research and Materiel Command CDMRP Prostate Synergistic Idea grant W81XWH Another method for improving spatial resolution is to use a high-resolution detector probe as an add-on to a standard PET scanner. While “ring-ring” coincidences will still support modest resolution, “probe-ring” coincidences will have excellent resolution near the high resolution probe detector. Moreover, effects induced by positron acolinearity, photon depth-of-interaction, and patient motion are significantly reduced for activity within the prostate. Photon attenuation is also reduced. Shown at right is a plot of the intrinsic spatial resolution as a function of distance from the probe for a conventional PET ring having 6mm intrinsic resolution and probes having 1mm, 2mm, and 3mm intrinsic resolution. Note that the improvement can be significant even at >5cm from the probe face. Although the technologies associated with the basic concept and detector are absolutely essential, there are many additional ingredients necessary for testing with human subjects. These include the mechanical design of the probe housing, considerations for temperature control, mounting of electronics, and tracking the position and orientation of the probe, which may move during the PET acquisition. To address these issues, we enlisted a team from a two-semester design course in the Department of Biomedical Engineering at Michigan. Shown immediately to the right is the current design, which houses the detector, motion sensors, and EM shielding (see author for 3D model). The panel above showed use of full-angle tomographic data while the prostate imaging probe will only acquire limited-angle high-resolution data. To evaluate effects, an external probe acquiring limited-angle data was simulated and results are shown above. External ring had 4mm and probe had 1mm resolution. Images left-to-right are preliminary reconstructions from ring-ring, probe-ring, and probe-ring and ring-ring coincidences combined. Combined performance should exceed that of probe-ring alone as work progresses. Images at left show effects of adding limited angle BGO-Si data to poorer resolution BGO-BGO data alone (from above testbed). Although artifacts are present, resolution improvement is noticeable. P21-20 Demonstration of High Resolution PET Concept Prototype Development Demonstration of the “Limited-Angle” Imaging Probe Conclusions Mechanical Testing 20mm 45mm 40mm 85mm 30mm Motion Tracking Tests High resolution endorectal PET detector (“probe”) Conventional PET ring Modest resolution Excellent resolution close to probe Monte Carlo simulations using an anthropormorphic phantom, probe, and 80cm dia. PET ring showed that ~12– 60% more coincidence events from the prostate were detected depending on detector size (upper right). Plot below right shows effect on performance over PET ring alone in terms of noise advantage vs. resolution for only 12% additional efficiency and for probes having 1mm, 1.5mm, and 2mm resolution. A noise advantage of 10 is equivalent to 10 2 or 100x the number of events. New silicon photomultipliers and arrays of LYSO scintillators are enabling technologies for constructing miniature, high- performance PET detectors. Shown at right is a diagram of a probe detector having depth-of-interaction resolution developed by our collaborators at West Virginia University. For details on the detectors, please visit poster P21-17 The basic high resolution PET concept has been demonstrated with a partial BGO PET ring (100cm dia.) and two high resolution silicon detectors (1.4mm res.) located close to a small (4cm) field-of- view. Reconstructed resolution phantom images shown are from BGO-BGO, BGO-Si, and Si-Si events (left-to-right). Spot diameters are 4.8, 4.0, 3.2, 2.4, 1.6, & 1.2mm. Note the “lever-arm” resolution improvement over BGO-BGO reconstruction with BGO-Si data (as for the prostate probe). Originally, aluminum was the material of choice for constructing prototypes; however, it was determined that ABS plastic was considerably less expensive and had the required strength. (Yield strength 42 MPa, highest stress is ~22 MPa.) Seams will be sealed with parylene, which is biocompatible and a good electrical and moisture barrier. Low-noise and accurate position-tracking is essential for maintaining high spatial resolution. Shown above right is a setup used for measuring linearity and resolution of the Ascension 3D Trakstar pulsed magnetic system as well as position, linearity, and residual plots. Range measured is considerably larger than will be needed in practice. Resolution (rms) is ~0.3mm, which will not significantly degrade performance of probe. Work to develop a high resolution prostate imaging add-on is proceeding rapidly in parallel along three fronts: detector design, probe theory and image reconstruction, and housing design for testing with human subjects. Progress toward our goal of better PET imaging of the prostate has been significant with development of several suitable high-resolution detectors, demonstration of the high resolution PET and PET imaging probe concepts, and design of a prototype housing suitable both for initial tests with phantoms and for eventual testing with prostate cancer patients. Work remains on interfacing the probe to a clinical PET/CT instrument; however, PET manufacturers have shown interest in the technology, which should be useful for guiding biopsy (especially when combined wth MRI or ultrasound images). C-11-choline PET image of prostate cancer. PET ring External probe insert Object position As an imaging modality in prostate cancer, positron emission tomography (PET) allows the possibility of “engineering” radiotracers to follow specific metabolic pathways or indicate the presence of biomarkers associated with disease. However, our considerable investment in tracer development cannot be used to full advantage if PET instrumentation is not capable of imaging small prostatic lesions well. Presently, PET can detect prostatic lesions of ~8mm diameter. This due to strong attenuation of the annihilation radiation from the prostate, intrinsic resolution limits of the scanner, and patient motion during scanning.