An Ultrasensitive LC-MS+NMR Platform Utilizing Segmented-Flow Microcoil NMR, Nanospray ESI, and 4 mm LC Columns Yiqing Lin, Paul Vouros, Jimmy Orjala 1,

Slides:



Advertisements
Similar presentations
Lecture 8b Gas Chromatography.
Advertisements

Gas Chromatography.
Roger Kautz, Principal Research Scientist In Collaboration with Protasis / MRM and Varian Instruments Routine Manual Injection of Trace Samples Our Optimized.
Protein Quantitation II: Multiple Reaction Monitoring
Improvements in Mass Spectrometry for Life Science Research – Does Agilent Have the Answer? Ashley Sage PhD.
SMASH 2008 Recap: Introducing Citation, Your Hard- Working Lab Assistant Dean Olson, Ph.D. Director of Customer Support Protasis Corporation.
Rapid, Small-scale Dereplication of Bioactive Extracts John Blunt University of Canterbury New Zealand 1.
C.Bi 1, Y.Yamaguchi 1, S.Bamba 1, H.Kumada 2, K.Nakai 3 and T.Morimoto 1 1 Research and Development Office, Japan Chemical Analysis Center 2 Proton Medical.
Analysis of Residues. Laboratory Analysis of Debris and Other Samples 1. Preparation of Liquid Samples: Liquid samples are simply drawn into a special.
Pesticide screening LC-QTOF, Agilent. National Food Institute, Technical University of Denmark Disposition National Food Institute –EURL –NRL –Personale.
Routine Analysis of Five-Microliter Samples using an automated microflow NMR system Bernhard H. Geierstanger, Ph.D. Protein Sciences Department Genomics.
Development of an Automated, Pyridine Free Method for Aerosol Cyanide Compounds and Hydrogen Cyanide. An Alternative to NIOSH LeRoy Dobson, Chemist.
In carbon-13 NMR, what do the number of peaks represent?
Tryptic digestion Proteomics Workflow for Gel-based and LC-coupled Mass Spectrometry Protein or peptide pre-fractionation is a prerequisite for the reduction.
Building High Throughput Natural Products Libraries
Principles of Chromatography. Chromatography is the most powerful tool for separating & measuring the components of a complex mixture. Quantitative &
Comparison of chicken light and dark meat using LC MALDI-TOF mass spectrometry as a model system for biomarker discovery WP 651 Jie Du; Stephen J. Hattan.
Chapter 6 - Chromatography
Quality-Assurance for the NMR Data Consumer Integrating NMR into Modern Laboratory Workflow Robert W. Albrecht Craig Milling PhD Dean Olson PhD Protasis.
Chemical Ideas 7.6 Chromatography. The general principle. Use – to separate and identify components of mixtures. Several different types - paper, thin.
High Performance Liquid Chromatography
Chromatography Chapter 6.
Quantitative Chemical Analysis Seventh Edition Quantitative Chemical Analysis Seventh Edition Chapter 0 The Analytical Process Copyright © 2007 by W. H.
Workflow of SeMet Protein Preparation Yingyi Fang Haleema Janjua.
Peak-purity by LC-MS and LC-DAD Knut Dyrstad Erlend Hvattum Sharon Jara Arnvid Lie.
Sample Preparation Strategies for Routine Trace Mixture Analysis by NMR David Detlefsen, Kenneth Ray & Jeffrey Whitney.
Using Linear Scale-up Principles and the Varian 940-LC with Scale-Up Module for the Isolation of 5-Hydroxytryptophan from Griffonia Simplicifolia Dennis.
William Kou Jonathan Mertz. Introduction The field of Mass Spectrometry using Ambient Ionization techniques has grown exponentially since The direct.
Integrated Targeted Quantitative Method for Insulin and its Therapeutic Analogs Eric Niederkofler 1, Dobrin Nedelkov 1, Urban Kiernan 1, David Phillips.
Chem. 231 – 2/18 Lecture. Announcements Set 2 Homework – Due Wednesday Quiz 2 – Next Monday Set 1 Labs –should be switching instruments today (or after.
Quality Assurance How do you know your results are correct? How confident are you?
A new "Molecular Scanner" design for interfacing gel electrophoresis with MALDI-TOF ThP Stephen J. Hattan; Kenneth C. Parker; Marvin L. Vestal SimulTof.
Innovative Paths to Better Medicines Design Considerations in Molecular Biomarker Discovery Studies Doris Damian and Robert McBurney June 6, 2007.
Improving the Detection of Hydrophilic Peptides for Increased Protein Sequence Coverage and Enhanced Proteomic Analyses Brian S. Hampton 1 and Amos H.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Introduction to Chromatography. Introduction Chromatography permit the scientist to separate closely related components of complex mixtures. In all chromatographic.
Stability Indicating Assays for Dose Formulation Stability Testing Teresa Fuller GSK.
Chapter 28 High Performance Liquid Chromatography.
Workflow of the Manual Purification of N/NC5-enriched proteins
Chem. 231 – 2/11 Lecture.
Chromatography and Instrumentation. Chromatography Separate Analyze Identify Purify Quantify Components Mixture Chromatography is used by scientists to:
PERFLUORINATED CARBOXYLIC ACIDS AND SULFONIC ACIDS IN WASTE SAMPLES Katsuya Y 1 *,Takemine S 1, Matsumura C 1, Tsurukawa M 1, Haga Y 1, Fujimori K 1, Nakano.
Microcoil NMR probes are well-established for analysis of trace (mass-limited) samples. This “microplug” loading method improves sensitivity by confining.
Lecture 8 Peak Parameters and Quantitative chromatography
3M Drug Delivery Systems 3 Introduction A family of hydrofluoroalkane-compatible excipients based on oligomeric lactic acid (OLA) has been proposed for.
EQUIPMENT and METHOD VALIDATION
Forensic Toxicology Use Only Analysis of ETG, ETS using the Thermo Scientific Exactive Mass Spectrometer Kent Johnson Fortes lab, Portland Oregon.
Yonsei Proteome Research Center Peptide Mass Finger-Printing Part II. MALDI-TOF 2013 생화학 실험 (1) 6 주차 자료 임종선 조교 내선 6625.
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
CHROMATOGRAPHY.
H M Arif Ullah, Hye Jin Chung*
Plasma Free Metanephrines Analysis using LC-MS/MS with Porous Graphitic Carbon Column Xiang He (Kevin) and Marta Kozak Thermo Fisher Scientific.
Multi-Analyte LC-MS/MS Methods – Best Practice.
James Byrd, Marta Kozak 28 Apr 2011
Chemical Ideas 7.6 Chromatography.
Chromatography- TLC & HPLC
LU 3: Separation Techniques
Profiling counterfeit Cialis, Viagra and analogs by UPLC–MS
Automation of Solid Phase Extraction Column Chromatographic Cleanup
Mass Spectrometry Vs. Immunoassay
Automation of Sample Preparation for Trace Analysis Haibin Wan
High Performance Liquid Chromatography HPLC
Chem. 31 – 11/1 Lecture.
Development of Antibiotic Activity Profile Screening for the Classification and Discovery of Natural Product Antibiotics  Weng Ruh Wong, Allen G. Oliver,
Peter Kovarik and Yves LeBlanc
High Resolution Quantitation of Microcystins with SCIEX X500R QTOF System KC Hyland.
Ultraviolet A Induces Generation of Squalene Monohydroperoxide Isomers in Human Sebum and Skin Surface Lipids In Vitro and In Vivo  Swarna Ekanayake Mudiyanselage,
Development of Antibiotic Activity Profile Screening for the Classification and Discovery of Natural Product Antibiotics  Weng Ruh Wong, Allen G. Oliver,
Electron Capture Detectors
CHROMATOGRAPHY.
Presentation transcript:

An Ultrasensitive LC-MS+NMR Platform Utilizing Segmented-Flow Microcoil NMR, Nanospray ESI, and 4 mm LC Columns Yiqing Lin, Paul Vouros, Jimmy Orjala 1, Roger Kautz* and NIH R01 GM The Barnett Institute of Chemical and Biological Analysis Boston, Massachusetts 1 Dept. Pharmacognosy, U. IL Chicago High Throughput Microcoil NMR Using Segmented Flow Sample Loading NanoSplitter LS-MS: Sampling Flat Region of Parabolic Flow Preserves Chromatographic Resolution. 40-fold Better S/N fold better mass sensitivity. Reduced Ion Suppression Microanalyical Methods In Natural Product Discovery (right). The traditional method of natural product drug discovery would be to use bioassay-guided fractionation to purify an active compound, then to scale up growth and fractionation to obtain enough of the compound for analysis and identification. With automated microanalytical methods, MS and NMR data can be obtained non-destructively during the separation before bioassay. Data may be examined retrospectively for fractions that are positive in subsequent bioassay, and known compounds can be recognized from MS and NMR data. Novelty and potency can thus be established prior to the laborious scale-up preparation. Total Ion Chromatogram min mAU DAD1 C,Sig=210,8 Ref=360,100 (YIQING\YIQING_092706_5.D) RT: SM:7B Time (min) Relative Abundance UV NMR cycloheximide 20 µg 1 µg.2 µg (1/15 y-scale) 1.5x y-scale 1x y-scale X 1 hr /fraction Sample Preparation: CyanobacterialCulture centrifugation freeze-dry SPE cleanup organic solvent extraction Silica gel column prefractionation 6 Fractions Example: Fraction 2 (30μginjection) UV chromatogram min mAU DAD1 A,Sig=254,4 Ref=360,100 (YL_090707_1903_FRC2_2.D) taxol HapalindoleH ambiguineI E new compound? HRMS: m/z Calculated for C21H24N2, error 0.6ppm Hapalindole H m/z : loss of HCN m/z : loss of HCN new compound? taxol (300 ng onto LC) taxol (reference) An offline approach to LC-NMR accommodates the disparate timescales and sample mass requirements of LC-MS and NMR. The 10-fold better mass sensitivity of microcoil NMR probes is accessible by concentrating collected LC fractions; a robust automated system for loading samples from 96-well plates is commercially available. This poster describes further optimizations to this approach using two recently-developed technologies from the Barnett Institute. LC-MS-NMR of entire separation NMR of fractions selected after LC-MS Evaluation The combination of MS and NMR data are the gold standard for identifying unknown compounds. LC-MS-NMR is thus desirable for profiling trace constituents of complex mixtures; however, where MS analysis takes under 1 second with 1 ng of analyte, NMR at the microgram level requires hours to days, depending on the information required (1D, 2D, Heteronuclear). The nanosplitter was developed to provide the advantages of true nano- electrospray MS with LC separations on normal bore (2 mm and larger) columns. The nanosplitter consumes only 0.1% of the LC eluent, allowing 99% to be collected for NMR. If the column capacity is 100 µg of the largest peak, then a 0.2% constituent will produce an interpretable spectrum in LC-NMR (below). This “microplug” automated loading system can pick up 2.0 µL of 2.5 µL in a 96- well plate, and load it into a microcoil NMR probe without additional dilution. The flow system is filled with a fluorocarbon fluid, immiscible with common NMR solvents. Sample plugs are formed by drawing alternately from a 96-well plate of samples and a vial of the immiscible fluid (Fluorinert FC43). 'Wash' plugs of clean DMSO are inserted between samples to eliminate 50 nL of carryover that occurs in non-ideal components. The wash plugs also provide a reproducible signal for positioning the following sample plug. Commercially available components were used to acquire all data below: a Protasis/MRM microcoil NMR probe and a Gilson 215 sample handler. (The figure above was made with a home built probe, from Kautz et al. 2005). It is planned to implement the microplug method with Protasis 1-minute NMR platform. UV-DAD LC-MS Nanosplitter ESI-MS Culture Bioactivity Segmented Flow Loading Sample Recovery LC–MS + offline microcoil NMR Metabolite Identification Platform Bioactive Fraction LC Separation Fraction Collection 200 µL Fractions NMR Microcoil Evaporate LC Solvent Resuspend in 2-4 uL NMR solvent LC-MS Lab NMR Lab Biochem Lab (Store in Freezer) An offline NMR approach has advantages: LC-MS is performed routinely, on familiar (or validated) equipment. NMR data can be requested retrospectively, after review of LC-MS data. All available sample mass from the entire LC peak width is pooled for NMR. The most mass-sensitive (smallest) NMR probes can be used. NMR time can be allocated according to the information needed: Time-based collection resembles on-line LC-NMR data, or Peak-based collection of components of specific interest. The limit of detection was confirmed by spiking the cyanobacterial extract (at right) with 300 ng of taxol (350 nmol). A 2 hr NMR acquisition of the fraction recovered after LC is shown below. Note the NMR sensitivity may be doubled or quadrupled by pooling 2 or 4 LC runs (30 min each). Comprehensive LC- NMR is illustrated in the following analysis of standards, a mixture of taxol, indapamide, and digitoxin. Time based fraction collection was used and NMR was acquired of all fractions, with 2 hr per fraction in an overnight automated NMR run. This comprehensive LC-NMR approach would be used to detect compounds with poor electrospray ionization and UV absorbance, such as glycans and lipids. A cyanobacterial extract found to be active in a proteasome inhibition assay was analyzed by LC-MS (30 µg loaded to LC). Fractions were collected of LC peaks and analyzed by microplug NMR (2 hr/peak). A number of known metabolites could be identified from the combined MS and NMR spectra; one was established as novel. Correlation of MS, UV, and NMR data. Retention times of standards MS and UV chromatogram correlated within 0.6 sec, in 6 replicates of 4 standards examined. Fraction breakpoints for NMR are recorded on the UV chromatogram. Recovery: Comparing the amount of indapamide loaded onto the column with the amount resuspended for NMR analysis, the recovery was 92% with an RSD of 1.1% over six repetitions. Limit of Detection. Injecting 250 ng of indapamide on-column produced an NMR spectrum with a S/N of 3 for its lowest-intensity peak. Linearity. From 0.25 to 25 µg indapamide were loaded onto LC. The NMR integral of recovered indapamide is plotted below against the amount loaded. The plot is linear with an R 2 of