Improving the Detection of Hydrophilic Peptides for Increased Protein Sequence Coverage and Enhanced Proteomic Analyses Brian S. Hampton 1 and Amos H.

Slides:



Advertisements
Similar presentations
Introduction to Chromatography
Advertisements

Comprehensive Profiling of the Proteome, Lipidome, and Metabolome Enabled Using a Prototype UPLC-Compatible Microfluidic Device J. Will Thompson 1, Jay.
GC & LC.
KROMATOGRAFİ Sedat Türe. HPLC Liquid Chromatography.
Introducing the EASY-nLC™
Gradient Manipulation and 1.8 µm LC Columns for High Resolution Analysis of Herbal Supplements John W Henderson Jr, Thierry Faye, Ulrik Witteg, Maureen.
* CORRESPONDING AUTHOR Bioanalysis of Exenatide: Intact Versus Signature Peptide Approach to Reach Optimal Sensitivity in Large Molecule Quantification.
Results Initial chromatographic conditions [Figure 2a caption] for the separation of the degradation products of aspirin were problematic due to the long.
In this contribution we present a new automatic procedure for background correction that, for the first time, can be successfully applied in both isocratic.
11 Determination of the Levels of Fungicides on Citrus Fruits By Miseung Borgers Chem 4101, Fall 2008.
Using Chromatography to Select Effective Biomineral Growth Modifiers Tissa J. Thomas and Ryan E. Sours Department of Chemistry, Towson University, Towson,
FIGURE 5. Plot of peptide charge state ratios. Quality Control Concept Figure 6 shows a concept for the implementation of quality control as system suitability.
Gel Filtration Chromatography.
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
Introduction : Standard methodologies for enzymatic digestions have changed little in the past 40 years. The same process for sample incubation with trypsin,
Production of polypeptides, Da, and middle-down analysis by LC-MSMS Catherine Fenselau 1, Joseph Cannon 1, Nathan Edwards 2, Karen Lohnes 1,
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Chromatography Separates components in mixture: Based on - polarity
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
High Performance Liquid Chromatography (HPLC) Jeannette Comeau CHEE April 2004.
CHROMATOGRAPHY. The general name given to methods by which two or more compounds in a mixture are physically separated by distributing themselves between.
GC Advantages 1. Very Large N (Very Long Columns) 2. No Packing Material (A=0) 3. Simple Mobile Phase (Compressed Gas) 4. Universal Detectors (FID) 5.
Simple Scale-up on a 940-LC Analytical to Preparative HPLC
INTRODUCTION Concentration-dependent peptide losses during the drying step in the sample preparation: influence of additives Adel Pezeshki 1,2, Valentijn.
Normal-phase chromatography is really not that normal. That is to say that it is used much less frequently than reversed-phase chromatography. The main.
INTRODUCTION TO CHROMATOGRAPY
Additional file 1 1.1Workflow of large-scale proteomic analysis of normal human kidney glomerulus 1.2Detailed procedure of LC-MS/MS analysis Additional.
In-Gel Digestion Why In-Gel Digest?
High Performance Liquid Chromatography. The chromatogram is a record of detector output Vs time as the analyte passes through the chromatography.
HPLC – High Performance Liquid Chromatography
Introduction  High-performance liquid chromatography (HPLC) is a form of liquid chromatography.liquid chromatography  The main purpose is to separate.
OPTIMIZATION OF BISPHENOL A, 4-t-OCTYLPHENOL, AND 4-NONYLPHENOL EXTRACTION FROM HUMAN BLOOD SERUM WITH HYBRID SOLID PHASE EXTRACTION – PROTEIN PRECIPITATION.
1 HPLC Lecture Displacement pumps Displacement pumps, on the other hand, is composed of a one directional motor driven plunger that pushes the mobile.
Introduction to Chromatography. Introduction Chromatography permit the scientist to separate closely related components of complex mixtures. In all chromatographic.
Best Broken into four categories
Chromatography High Performance Liquid Chromatography HPLC Chapter Dr Gihan Gawish.
HPLC.
Biochemical instrumental analysis - 11 Dr. Maha Al-Sedik 2015 CLS 332.
LC/MS Chromatography Systems 212-LC. 2 The Complete Solution Varian LC components, pumps, autosamplers and the New MS Workstation SW (V6.6) can be used.
Salamanca, March 16th 2010 Participants: Laboratori de Proteomica-HUVH Servicio de Proteómica-CNB-CSIC Participants: Laboratori de Proteomica-HUVH Servicio.
Liquid Chromatography 2: New Technology Lecture Date: April 3 rd, 2007.
HPLC.
Lecture 8 Peak Parameters and Quantitative chromatography
Toxicological Screening of 80 Drugs in Urine Using the High Resolution Exactive LC/MS Orbitrap Mass Spectrometer Coupled to Online Extraction and Turbulent.
The world leader in serving science For Research Use Only. Not for use in diagnostic procedures Quantitative Analysis of 4 Immunosuppressant Drugs in Whole.
Presented by Deepthi Ravipati. Barbiturates are derivatives of barbituric acid. They act as central nervous depressants. These drugs are frequently used.
Instrumental Analysis (I)  HPLC Tutorial #7 PHCMt561 – 5 th Sem. Pharm.
Protein Identification using 2D LC/MS/MS based on pH Gradient and Reverse Phase Separation Column Technology Inc.,
Results Protein Removal is shown in the silver stained SDS-PAGE gel in Figure 3 below: F IGURE 3: A 10% SDS-PAGE gel after silver staining showing the.
 Laboratory technique for the Separation of mixtures  Chroma -"color" and graphein - "to write”.  Colour bands - separation of individual compounds.
Experiments in Analytical Chemistry
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
H M Arif Ullah, Hye Jin Chung*
Martin-Luther University Halle-Wittenberg, Germany
Multi-Analyte LC-MS/MS Methods – Best Practice.
James Byrd, Marta Kozak 28 Apr 2011
A guide for A level students KNOCKHARDY PUBLISHING
Chem. 133 – 5/11 Lecture.
For Forensic Toxicology use Only
Agility WCX SPE Cartridges
Analysis of Anamorelin Stereoisomers in Human Plasma Using Coupled
Chromatographic separation
Bioinformatics Solutions Inc.
HPLC.
Chromatography Daheeya Alenazi.
Shotgun Proteomics in Neuroscience
A guide for A level students KNOCKHARDY PUBLISHING
Transferring LC-UV to LC-MS.
Presentation transcript:

Improving the Detection of Hydrophilic Peptides for Increased Protein Sequence Coverage and Enhanced Proteomic Analyses Brian S. Hampton 1 and Amos H. Heckendorf 2 1 Center for Vascular and Inflammatory Diseases, University of Maryland School of Medicine, Baltimore, Maryland, USA, 2 The Nest Group, Inc., Southborough, Massachusetts, USA Introduction Reversed-phase pre-columns, commonly referred to as trap columns, are widely used for capturing peptides from enzymatic digests of proteins to facilitate removal of interfering substances, or as a concentration step prior to their introduction (in-line) to a high resolution separation column and subsequent analysis by liquid chromatography tandem mass spectrometry (LC MS/MS). Binding of peptides to the trap column is therefore pivotal for a successful analysis. The parameters of contact time (flow rate) and loading solvent composition are examined to determine their effects on the ability of peptides to bind to a water wettable C18 stationary phase trap column. Methods Fifty picomoles of human low density lipoprotein receptor-related protein- associated protein-1(RAP) (kindly provided by D.R. Strickland laboratory) was digested with TPCK treated bovine trypsin (Worthington) at a final concentration of 0.5µM in 50µl of 25mM ammonium bicarbonate, 20% acetonitrile, 5mM CaCl 2 for 4 hrs at 37°C. The digested protein was dried by rotary evaporation and resuspended in 0.1% formic (FA), or trifluoroacetic acid (TFA) and was diluted to 50 femtomoles/µl prior to analysis by LC MS/MS (LCQ Advantage, Thermo Fisher). The stationary phase for both the trap and separation column was a 5µm, TARGA® C18 (Higgins Analytical). The HPLC consisted of a single Waters Alliance® 2695 that was modified with a standard Rheodyne® 2-position 6-port valve inserted in the solvent flow path between the pump and the autosampler to allow flow to be directed through the autosampler for loading samples onto the trap column, and subsequently switched to bypass the autosampler during gradient separation. This configuration eliminated the relatively large system volume contained in the autosampler of the HPLC during the gradient separation portion of the chromatographic run. In addition the flow from the HPLC pump was split to achieve the low flow rates used in this study. Samples consisting of 200fm of digested protein in a volume of 4µl of either 0.1% FA or 0.1% TFA were loaded onto a 250µ x 23mm trap column for 30 minutes at linear velocities (contact time) ranging from 1.6 to 7.2 column void-volumes/min (CV/min). To calculate linear velocity in CV/min, the void volume was estimated to be ~50% of the internal volume of the trap column. Bound peptides were eluted onto a 75µ x 200mm column equilibrated in 0.1% FA and eluted with a gradient of acetonitrile containing 0.1% FA at a flow rate of approximately 250nl/min. The gradient went from 0 to 5% acetonitrile in 5 min and then from 5 to 25% acetonitrile in 60 min. The trap and separation columns were re-equilibrated for 20 min prior to injection of the next sample. LC MS/MS analysis was carried out using a Thermo-Finnigan LCQ Advantage® ion trap mass spectrometer utilizing nanospray ionization. MS analysis consisted of repetitive cycles of full MS scans over the range of m/z followed by MS/MS analysis of the three most abundant ions from the full MS scan. These ions were subsequently excluded from further MS analysis for 3 minutes. Data from the raw files were extracted with Bioworks 3.1 and concatenated into a single file using the perl script Merge. The merged data from each run was used to search the human subset of the Swiss-Prot database using X! Tandem at ( Configuration of the 2-Way Valve for Trapping and Elution of Peptides A standard configuration of the 2-way valve allowing bound peptides to be back-flushed from the top of the trap column to the separation column where they are “refocused” providing minimal loss of resolution. Sample Loaded onto Trap column in 0.1% TFASample Loaded onto Trap column in 0.1% FA Increasing Contact Time Markedly Improves Trapping of Hydrophilic Peptides Partial Reconstructed Ion Chromatogram Showing Enhanced Retention of Specific Hydrophilic Peptides 7.2 CV/min 1.6 CV/min 3.6 CV/min 7.2 CV/min 1.6 CV/min 3.6 CV/min 7.2 CV/min Increased Retention of Hydrophilic Peptides Improves Database Search Confidence and Sequence Coverage X! Tandem Log (e) Score Sequence Coverage (%) Results Preliminary experiments where peptides were loaded onto a trap column at flow rates typically published in the literature (≥60 CV/min or equivalent to 15µl/min through a 0.5µl trap column) demonstrated a lower than expected yield of peptides in the early portion of the chromatogram. Adding TFA to the sample solution for trap loading modestly improved the overall retention of peptides but was unable to effect retention of the hydrophilic peptides at a flow rate ≥ 7.2 CV/min. Decreasing the flow rate at which peptides were loaded onto the trap had a dramatic effect on retention of hydrophilic peptides. These peptides were retained when the flow rate was reduced to 3.6 CV/min with maximal binding occurring at 1.6 CV/min. The presence of TFA in the sample solution during trap loading showed increased retention of hydrophilic peptides compared to FA. However a subset of these peptides were not retained when the flow rate was increased from 1.6 to 3.6 CV/min. The greater number of peptides retained when the sample was applied to the trap at lower flow rates and in the presence of 0.1% TFA improved sequence coverage, and the X! Tandem Log (e) score. Conclusions Increasing the contact time of the peptides with the stationary phase allows retention of hydrophilic peptides that otherwise would not bind to the trap column at higher flow rates. Contact time can be increased in either of two ways: lowering the flow rate during trap column loading increasing the trap column volume by making it longer (not wider which would have adverse effects) TFA in the sample solution improves retention of hydrophilic peptides at a low flow rate but not at a high flow rate compared to FA. Equilibration of the TARGA® C18 columns, a polar embedded stationary phase, in the complete absence of organic solvents provided more favorable conditions to retain hydrophilic peptides compared to other C18 stationary phases that require the presence of some organic solvent to allow access to the porous structure of the reversed-phase support. Providing adequate contact time increases the number of peptides bound and available for analysis during the chromatographic run. This improves sequence coverage and database search result confidence scores and allows structural analysis of peptides that would otherwise be lost during trap loading.