Solar Home System Standard Specification (Draft for Discussion )

Slides:



Advertisements
Similar presentations
Grid Connect Inverters NUER 19
Advertisements

Electrical Systems Chapter 9.
ERA SOLAR PRODUCTS ERA Renewable Energy. Solar energy is the ultimate source of energy from millions of years and it is a renewable energy. This energy.
MODULAR SMPS POWER PLANT
Rooftop Solar Systems Rooftop Solar System (Off-Grid) Reliance Solar Energy™, Ratnagiri.
Introduction Since the beginning of the oil crises, which remarkably influenced power development programs all over the world, massive technological and.
LP33 Series UPS kVA 400Vac/CE
Lecture 1: Safety and Protection. 1. A robot may not injure a human being or, through inaction, allow a human being to come to harm. 2. A robot must obey.
Electrical Power Systems
POWER SUPPILES LECTURE 20.
Photovoltaic Solar Cells and Solar Energy Systems for Home Usages Mohammad Anisuzzaman.
Solar Home UPS 850VA & 1400VA India’s first Sine wave inverter with in built Solar Charge Controller and Controlled DC Load Output. Simultaneous Charging.
To develop a small scale solar powered system that will power a DC load, which incorporates power management techniques, DC-DC conversion and a user interface.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE.
1. Presentation Overview  Solar Industry Overview  Intro into Solar Photovoltaics  Types of PV Systems  Solar Product Offering –Solar Combiner Boxes.
UDC ZERO ENERGY VISTOR CENTER. System Components Solar Array –Primary Power Generator –Array consists of 12 BP SX3190B Solar Modules.
How to determine whether solar energy is right for your site EE80S: Sustainability Engineering and Practice Fall 2007.
SOLAR CELL PRESENTED BY ANJALI PATRA ANKITA TRIPATHY BRANCH-EEE.
EGD ELECTRICAL ELECTRICAL SYMBOLS.
1 Introducing Solar Power!. 2 Background  Why are photovoltaic (solar power) panel assemblies needed? –cost effective alternative –to provide power where.
Inverters November 2007, Alex Righolt. Overview A&A Computers sell and install inverter systems as an alternative to UPS-es. Inverters are easily scaleable;
E8 / PPA Solar PV Design Implementation O&M Marshall Islands March 31-April 11, 8・5 - Field Inspection Items Visual inspection and verification.
Solar Lightings Solar Module. Charge Controller. Battery. Inverter. Loads Accessories.
Electrical Fundamentals
Solar PV Design Implementation O& M March 31- April 11, 2008 Marshall Islands 2. Solar Home Systems (SHS) 2. Solar Home Systems (SHS) Herb Wade PPA Consultant.
Off-Grid Power Using Enphase Micro-Inverters Off-grid inverter systems, using batteries, can be used to provide AC power when the grid is down. It is possible.
Station Battery Solar AC Source Home Batteries Battery Chargers.
150W Inverter - an optimal Presenter: Dr Gawie van der Merwe design in solar home systems.
Sustainable Energy Systems Engineering Peter Gevorkian Ch 2: Solar Power Generation Design Brevard Community College EST1830 Bruce Hesher.
Lesson 9: Electrical Components
Technician License Course Chapter 5 Amateur Radio Equipment Lesson Plan Module 12: Power Supplies and Batteries & RF Interference (RFI)
Designing Solar PV Systems (Rooftops ). Module 1 : Solar Technology Basics Module 2: Solar Photo Voltaic Module Technologies Module 3: Designing Solar.
POWER PLANT USED IN TELECOM
Photovoltaic (fo-to-vol-ta-ik) systems are solar systems that produce electricity directly from sunlight. The term "photo" comes from the Greek "phos,"
PV off Grid Design Eng. Laith Basha
Solar Home Lighting system. DESCRIPTION A distributed energy access model High efficiency electronics Can be assembled and customized by both large and.
Michael Ikerionwu 4 th year Electronic Engineering.
You and Your Solar Panel
Solar PV Tender Overview Ministry of Livestock, Fisheries and Rural Development Department of Rural Development Place - Sule Shangri-La Hotel Date- 4 -
The Vocabulary of Electrical Power Solar Under The Sun Solar School May 2010.
Solar tracker system.
Introduction to Solar Photovoltaic (PV) Systems – Part 2
INNOVATION BUS GROUP:INNOTHENTICTECH PHASE 1 REFURBISHED BUS THIS PRESENTATION CONCETRATES ON POWER SUPPLY AND LOADS ONLY.
Avoid _____________ _____________ _____________ _____________ _____________ _____________.
Abstract This presentation discusses a solution that provides efficiency and maximum output for a cheap and alternative source of power in Nigeria The.
Product Introduction Reported by Jerry Huang
What is PV System? Photovoltaic (PV) system is an electrical system consisting of array of one or more PV modules, conductors, electrical components,
1. 2 PRODUCTS OF C.E.L Solar Photovoltaic Cells Solar Photovoltaic Modules Cathodic Protection Electronic Ceramics Railway Electronics Microwave Electronics.
By:- Aliza Ibrahim RRIMT,Lucknow. Solar street lights are raised light sources which are powered by photovoltaic panels generally mounted on the lighting.
Assessment and Design of Rooftop Solar PV system
– S O L A R – – S T R E E T – – L I G H T –
PV STREET LIGHTING SYSTEM IN MARGINENI COMMON
Solar Energy Improvement Techniques
Photovoltaic Systems Engineering Electronic Control Devices (ECDs)
PV STREET LIGHTING SYSTEM IN MARGINENI COMMON
By: Raed Wa’el Ennab & Raja Sa’ed Anabtawi
SOLAR INSTALLATION AND DESIGN: THE DOS AND DON’TS
ECE 445 Senior Design, Spring 2018
Protecting you from the worst electrical problems
Photovoltaic (PV) Systems
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Online Emergency Lighting Inverter
Photovoltaic Systems Engineering Session 10
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
ANALYSIS, DESIGN & ESTIMATION OF residential building with p.v installation under the guidance of Mr. S.Bhanu Prakash, M.Tech Assistant Professor Department.
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Indoor Off-Grid and Grid Lighting
SMPS POWER PLANT SMR 48V/25A SALIENT FEATURES
Presentation transcript:

Solar Home System Standard Specification (Draft for Discussion ) Ministry of Livestock, Fisheries and Rural Development Department of Rural Development Place - Sule Shangri-La Hotel Date- 4 - 12 - 2015

System-1 Minimum power of solar PV array: 30Wp Minimum battery storage capacity : 12V/20Ah (Lead-acid)(50%DoD) : 12V/12Ah (Li-ion)(90% DoD) Charge controller : 12V/2A (PWM type) Minimum DC LED lumens: 240 Lumens ( 80lumen/watt)- 3nos -3.5hr DC socket outlet : USB type ( for cell-phone charging – 2.5hr) 12V/2A DC socket outlet: 15W DC TV (1.2hr) A wiring kit of appropriate size for All DC wiring Balance of system materials including: mounting structure, battery box, battery fuse, cabling, light switches, User Manual and O&M manual

System-2 Minimum power of solar PV array: 45Wp Minimum battery storage capacity : 12V/30Ah (Lead-acid)(50%DoD) : 12V/16Ah (Li-ion)(90% DoD) Charge controller : 12V/3A (PWM type) Minimum DC LED lumens: 240 Lumens ( 80lumen/watt)- 4nos -4hr DC socket outlet : USB type ( for cell-phone charging – 2.5hr) 12V/2A DC socket outlet: 15W DC TV (1.8hr) A wiring kit of appropriate size for All DC wiring Balance of system materials including: mounting structure, battery box, battery fuse, cabling, light switches, User Manual and O&M manual

System-3 Minimum power of solar PV array: 60Wp Minimum battery storage capacity : 12V/40Ah (Lead-acid)(50%DoD) : 12V/23Ah (Li-ion)(90% DoD) Charge controller : 12V/5A (PWM type) Minimum DC LED lumens: 240 Lumens ( 80lumen/watt)- 5nos -5hr DC socket outlet : USB type ( for cell-phone charging – 2.5hr) 12V/2A DC socket outlet: 15W DC TV (3hr) A wiring kit of appropriate size for All DC wiring Balance of system materials including: mounting structure, battery box, battery fuse, cabling, light switches, User Manual and O&M manual

PV modules Certification standards Crystalline Modules: Mono-crystalline , Poly-crystalline IEC 61215 (2005-04),IEC 61646 certified module, ISO 9001 certification Crystalline Modules have 36 cells for 12V batteries Tolerance of rated output of PV modules offered shall be positive only Warranty: 10 years

Continue - PV modules Solar Module shall be warranted to produce at least 80% of rated peak watt output for at least 10 years. Solar module should have a full replacement warranty if it fails within one year due to manufacturing or material defect. The module shall be labeled indicating at a minimum Manufacturer, Model Number, Serial Number, Peak Watt Ratting, Voltage and Current at peak power, Open Circuit Voltage and Short Circuit Current of each module.

Batteries Certification standards IEC 61427 Ed. 2.0 (2004-05), IEC 60896-11; Ed 1.0 (2002), IEC 60896-21 and 22 Ed 1 (2004) ,ISO 9001 Certificates or equivalent standards i.e IEEE, may be proposed by suppliers Lead-acid: deep-cycle, heavy-duty, tubular positive plate, with immobilized electrolyte and valve regulated operation(75%) loadshed DoD) Lead-acid: deep-cycle, heavy duty, tubular positive plate with vented and flooded electrolyte cell(75% loadshed DoD) Li-ion : deep-cycle, heavy-duty, sealed( 90% maximum loadshed DoD)

Continue- Batteries Battery capacity shall not be less than 80% of rated capacity over a period of 18 months 12V Lead acid battery wet weight of at least 0.35kg per rated ampere-hour(C/10rate)(eg. 58Ah battery must weigh at least 58 x 0.35 = 20.3 kg) Battery cycle life at 50% daily depth-of-discharge (DOD) must exceed 1,800 cycles Battery shall offer at least a four year useful life

The battery shall be housed in a vented compartment. All parts of the compartment subject to battery acid contact shall be acid resistant. This compartment shall be built strong enough to accommodate the weight of the battery. Fig 2.Sample of Battery

Charge controller Certification standards EC 62509 Ed.1, IEC 62109, IEC 62093 Ed.1.0, IEC 17025, IECEE standard, ISO 9001 certified manufacturer Solid state photovoltaic charge controller, Pulse Width Modulated(PWM) regulation Controller shall have a charging regime applicable to battery with voltage setpoints preset at factory Controller shall have LED indicator lights or meter to show state of charge and when the battery is in a charging mode Controller shall have protection against short circuit of input and output terminals as well as reverse polarity protection

Charge Controller configuration fig. Sample of charge controller Electronic automatically resettable cut-offs are required- mechanical fuses are not acceptable Controller shall be able to safely accept 125% of the module open-circuit voltage when battery is removed

LED luminaires Certification standards: Compliant with Lighting Global Standard, ISO 9001 DC LED lights has at least 240 lumens Minimum lumen efficiency of LED light should be 80 lumen/watt Provide minimum 90% of initial lumen output after 2,000 hours or 95% after 1,000 hours Increase in temperature of heat sink should not be more than 20ﹾCelsius after one hour operation Color of LED light shall be white LED light should be place at a height more 8 feet from ground Each light shall be controlled by a separate switch

Technical specifications for public facilities ( Draft for Discussion ) Ministry of Livestock, Fisheries and Rural Development Department of Rural Development Place - Sule Shangri-La Hotel Date - 4 - 12 - 2015

Minimum size of components for Public Facilities Description Design load grouth (Wh/day) Minimum PV array (Wp) Mimimum Battery (Ah@C20@V) Battery DoD MinimumCharge controller Minimum Inverter (VA) Battery Fuse Led (Qty) School -1 classroom 257 120Wp 55Ah 24V 75% 6A 100VA 9 School -2 admin+1 classroom(20’x24’) 726 310Wp 150Ah 16A 216VA 14 School-3 Admin+ 2 rooms(20’x24’) 897 375Wp 190Ah 20A 306VA 20 School-4 Admin+3rooms(20’x24’) 1154 475Wp 240Ah 25A 408VA 26 School-5 Admin+3rooms(30’x24’) 1411 575Wp 400Ah 30A 533VA 34 School-6 Admin+4rooms(30’x24’) 1668 675Wp 350Ah 35A 658VA 43 School-7 Admin+5rooms(30’x24’) 1925 775Wp 40A 783VA 52 Rural health centre 692 280Wp 15A 250VA Sub-rural health centre 432 180Wp 90Ah 9A 150VA 10A 6 Streetlight 147 70Wp 26Ah 12V 90% NA 8A 1 Pagoda lighting 383 1 x dormitary or ward 206 3

School -1 1 classroom (Example) Design load demand: 275Wh/day Minimum power of solar PV array: 120Wp Minimum battery storage capacity : 24V/55Ah (75%DoD-,fuse 6A ) Charge controller : 24V/6A (PWM type) Inverter: 100VA (sine wave inverter) AC interior LED : 720 lumen (strip luminaries-8 nos) AC exterior LED: 550 lumen ( bulkhead luminaries- 1nos ) A wiring kit of appropriate size for All DC and AC wiring Balance of system materials including: array mounting structure, battery box, battery fuse, AC distribution board, AC earthing, light switches, AC socket points, User Manual and O&M manual

Public streetlight systems Design load demand: 147Wh/day Minimum PV array: 70Wp Minimum Battery: 12V, 26Ah Minimum charge controller: 12V, 6A DC LED lamp: 1 nos, at least 1200lumens(12W), minimum 100lumens/watt 25,000 hour life to 80% of initial lumen output. Li-ion batteries are preferred. Battery life is at least 1500 charge-discharge cycles or 4 years. Battery capacity for on-time of a full 14 hours per day Streetlight unit shall switch on automatically at night and off during daylight hours The controller should control load switching using daylight sensing Concrete or wooden pole shall be suitable for mounting of luminaire at the sepecifie 5m heigh above ground level

Continue- Public streetlight systems Integrated housing for complete streetlight unit: Integrated housing for the lamp, PV module, charge controller, battery and electrical components The housing shall be corrosion protected, lockable, ventilated, and tamper proof The enclosure containing charge controller and battery shall be minimise heat transfer to the battery. The streetlight head mounting at shall attach at the top of the pole and the array to be oriented 10˚ to the horizontal.

Continue- Public streetlight systems Separate lamp head, PV module and battery enclosure: The solar array shall be mounted on an array mounting frame which attaches to the top of the pole and fixed angle of tilt of 10˚ to the horizontal. The charge controller, battery and battery enclosure shall be shaded and out of direct sunlight. The battery enclosure shall be corrosion protected, lockable, ventilated, and tamper proof housing. The battery and charge controller shall be mounted at the top of the pole in the shade of the solar array and the battery enclosure shall have a double skin to minimise heat transfer to the battery via the sun.

PV Modules for public facilities Certification Standards : ICE 61215(2005-04) : Design qualification and type approval Crystalline silicon terrestrial PV Modules PV array consists of one or more Mono-crystalline or Poly-crystalline Modules Thin film modules are not acceptable Rated power of each modules shall be at least 75Wp (except of streetlights) Only three standard sizes of modules shall be used to facilitate spares and parts management

Continue- PV module for public facilities All PV modules within an array shall be the same type Each Module must be factory equipped with either weather-proof junction box or a sealed weather proof termination for safe and solid wiring connection Crystalline Modules have a minimum of 36 cells connected in series for 12V batteries and 72 cells for 24V batteries Rated output tolerance of PV modules shall be positive only. Negative tolerance are not allowed. Warranty: (20) years Modules shall produce at least 80% of its nominal rated output at STC for at least 20 years.

Batteries for public facilities Certification standards: ICE 61427 Ed. 2.0(2004-05) ‘Secondary Cells and Batteries for Photovoltaic Energy Systems(PVES) IEC 60896-11,Ed 1.0(2002): ‘Stationary lead-acid batteries’ IEC 60896-21 and 22 Ed 1(2004);’ Stationary lead-acid batteries’ Certificates or equivalent standards i.e IEEE, may be proposed by suppliers Certificates for batteries will be accepted from same manufacturer and range, but of different capacity due to use of different numbers of plates

Continue- Batteries for public facilities Lead acid: deep-cycle, heavy-duty, tubular positive plate, with immobilized electrolyte and valve regulated operation (75% maximum loadshed DoD) Lead acid: deep-cycle, heavy-duty, tubular positive plate, with vented and flooded electrolyte cell( 75% loadshed DoD) Li-ion: deep-cycle, heavy-duty, sealed ( 90% maximum loadshed DoD) Battery cycle life at 50% daily depth-of-discharge (DOD) must exceed 1,800 cycles when tested in terms of IEC 61427 Ed. 2.0

Charge Controllers for public facilities Certification standards EC 62509 Ed.1: Performance and functioning of PV battery charge controllers IEC 62109: Safety of power converters for use in PV power systems IEC 62093 Ed. 1.0: Environmental reliability testing-Design qualification and type approval IECEE standard charge controller -PVRS6A Solid state photovoltaic charge controller Pulse width modulated (PWM) regulation type

Inverters for public facilities Certification Standards : IEC 62109 Safety of power converters for use in photovoltaic(PV )power systems.Part2: particular requirements for inverters. IEC 61683 Ed. 2.0: Photovoltaic systems- Power conditioners-Procedure for measuring efficiency IECEE,PVRS8A ‘Inverters for photovoltaic(PV) stand-alone systems’ For noise and emission , the following shall apply: IEC CISPR 22 Radio disturbance characteristics-limits and methods of measurement

Continue- Inverters IEC 61000-4-2 Electromagnetic compatibility(EMC) Testing and measurement techniques-electrostatic discharge immunity test IEC 61000-4-3 Electromagnetic compatibility (EMC) Testing and measurement techniques radiated, radio frequency, electromagnetic field immunity test. Only inverters with sine-wave outputs Only inverters with full galvanic isolation between DC and AC Sine wave inverters shall generate a sine-wave output of 230VAC +/- 5% and frequency of 50Hz +/- 0.5%. The real power(kW) output of the inverter shall not less than the rated kVA multiplied times 0.8(power factor).

LED interior/exterior luminaries(AC and DC) Certification Standards : Illumination Engineering Society’s(IES) IES-LM-79-08 Approved method of electrical and photometric measurements for solid state lighting products IES-LM-80-08 Approved method for measuring lumen maintenance of LED light sources LED lights only (AC LED , DC LED only for street lights) For AC LED, Energy star(US,Canada), Australian Energy Rating for appliances and European Eco-label for light bulbs certifications are allowable.

“Thank You for your attention ”