Practical aspects of thermodynamic analysis  Dynamic methods of phase equilibrium studies – DTA, HF-DSC a.Unary system; b. Binary and ternary systems.

Slides:



Advertisements
Similar presentations
Materials Research Laboratory
Advertisements

Thermal Analysis Differential Scanning Calorimetry (DSC) – Measure heat absorbed or liberated during heating or cooling Thermal Gravimetric Analysis (TGA)
Experimental Investigation and Mathematical Modeling of Cold-Cap Behavior in HLW Melter D. Pierce, J. Chun, P. Hrma, J. Rice, R. Pokorny, M. Schweiger.
Lecture 15. Phases of Pure Substances (Ch.5) Up to now we have dealt almost exclusively with systems consisting of a single phase. In this lecture, we.
Differential Scanning Calorimetry A bulk analytical technique
Mechanical & Aerospace Engineering West Virginia University Phase Diagram (1)
CHAPTER 8 Phase Diagrams 8-1.
Thermal Equilibrium Diagrams
Glass Transition & Melting
Chapter 6 Interpretation of Phase Diagrams Phase diagrams summarize in graphical form the ranges of temperature (or pressure) and composition over which.
1 Thermochemical and topological studies of systems constituted by transition metals (Co, Ni) with Sn and Bi G.P. Vassilev a, K.I. Lilova b, J.C. Gachon.
1 Thermal Analysis of Sn, Cu and Ag Nanopowders Pavel Brož, Jiří Sopoušek, Jan Vřešťál Masaryk University, Faculty of Science, Department of Chemistry,
Solidification and Grain Size Strengthening
Fig. 2In-Pd-Sn: Composition of the samples and position of the sections for calorimetry at 900°C. *Corresponding Author: Tel.-No , FAX-No.
Lead-Free Soldering: Phase Relationships and Thermochemistry of Ag-Cu-Ni-Sn H. Flandorfer, C. Schmetterer, U. Saeed and H. Ipser Department of Inorganic.
The Thermodynamics and Kinetics of Explosives Thomas M. Jerant Cindy D. Spangler.
Department of Food Science
Terry A. Ring Chemical Engineering University of Utah
ME4331 – DSC Review APR 29 , 2008 Jeung Hwan Choi.
DFG Priority Programme SPP 1473, WeNDeLIB:
EXPERIMENT # 9 Instructor: M.Yaqub
Phase Equilibria in the Ternary Ag-In-Pd-System Olga Semenova and Herbert Ipser Institut für Anorganische Chemie, Universität Wien, Währingerstr. 42, A-1090.
CHM 342 Thermal Methods of Analysis Background and Continued Evolution into Hyphenated Methods of Chemical Analysis.
First SIM² - WORKSHOP Thermal analysis (TGA/DSC): practical aspects TGA – Thermogravimetric Analysis DSC – Differential Scanning Calorimetry Jacek Chwast.
Introduction The properties and behavior of metals (and alloys) depend on their: Structure Processing history and Composition Engr 241.
Experimental determination of phase equilibria
Thermochemistry Chapter 17.
What is a DSC? What is DSC? Differential: measurement of the difference in heat flow from sample and reference side Scanning: the common operation.
1 Lecture: Solid State Chemistry (Festkörperchemie) Part 2 (Further spectroscopical methods, ) H.J. Deiseroth, SS 2004.
Unit 5: Matter and Energy I. Classification of Matter.
Interactive experimentation and thermodynamic modeling
How to calculate the total amount of  phase (both eutectic and primary)? Fraction of  phase determined by application of the lever rule across the entire.
Lecture 9 Phase Diagrams 8-1.
Thermal Equilibrium Diagrams Contain information about changes that take place in alloys.
Microstructure and Phase Transformations in Multicomponent Systems
Thermal Methods. It’s Hot in Here … Let’s talk Thermal By: Naaimat Muhammed.
Thermochemistry ( ) Enthalpy (ΔH) is related to the heat exchange that occurs during a chemical or physical process under constant pressure – Processes.
TGA/DTA Thermogravimetric analysis
Thermal Analysis Techniques
Differential Scanning Calorimetry (4.6) Differential scanning calorimetry (DSC) is a way of measuring energy changes associated with physical transitions.
20-1 Thermal Methods Theory Instrumentation Thermal methods §Physical properties of a substance are evaluated as a function of temperature àMay include.
Synthesis and Properties of Magnetic Ceramic Nanoparticles Monica Sorescu, Duquesne University, DMR Outcome Researchers at Duquesne University.
Other dynamic methods Phase diagram of ternary system and DTA
EBB 512 – Phase Diagram and Equilibria Lecture 1.
Analysis of DTA data for binary alloys
THERMAL ANALYSIS FOR PREFORMULATION TRIALS
1 Thermodynamic Equations (a)Heat, Work and the 1 st Law PV=nRT equation of state for ideal (perfect) gas work done against external pressure work done.
Some Analytical Tools. What is Thermal Analysis (TA)? A group of techniques in which a physical property (Enthalpy, thermal capacity or, Coefficient of.
DIFFERENTIAL THERMAL ANALYSIS (DTA)
Thermal Analysis.
Differential scanning calorimetry (dsc)
Experimental phase equilibrium study
Dynamic methods to construct phase diagrams
Material Science & Metallurgy Non Equilibrium Cooling
Thermal Analysis Differential Scanning Calorimetry (DSC) – Measure heat absorbed or liberated during heating or cooling Thermal Gravimetric Analysis (TGA)
Differential Scanning Calorimetry
Phase Diagrams 8-1.
THERMOGRAVIMETRIC ANALYSIS (TGA)
Thermal Analysis Differential Scanning Calorimetry (DSC) – Measure heat absorbed or liberated during heating or cooling Thermal Gravimetric Analysis (TGA)
Dnyanasadhana College, Thane.
Differential Scanning Calorimetry
TGA and DSC. Thermal analysis ○Thermal analysis is a branch of materials science where the properties of materials are studied as they change with temperature.
CHAPTER 8 Phase Diagrams 1.
CHAPTER 8 Phase Diagrams 1.
CHAPTER 8 Phase Diagrams 1.
Introduction to the Phase Diagrams MME 293: Lecture 05
Phase diagrams of pure substances
The States of matter.
Phase Diagram.
Thermal Analysis Techniques
Presentation transcript:

Practical aspects of thermodynamic analysis  Dynamic methods of phase equilibrium studies – DTA, HF-DSC a.Unary system; b. Binary and ternary systems c. TGA; d. heat capacity measurements using DSC  Isothermal methods (Phase equilibria, Diffusion couple);  Influence of kinetics  Applications 1.Classification of experimental methods 2.DTA/DSC for unary systems 3.Temperature and enthalpy calibration 4.Problems

Phase diagrams: relations to microstructure and properties

Eutectic phase diagram

Phase diagram with peritectic

Experimental methods used for phase diagram construction Static methods Dynamic methods Metals Ceramics Arc-melting Induction melting Solid state reactions Co-precipitation and pyrolysis DTA/TGA DSC Dilatometry HMA Charactirisation methods XRD – phase identification, phase boundary determination SEM/EDX microstructure examination, phase composition determination (for identification) EPMA for more precise phase identification EBSD for structure determination Diffusion couples Homogenisation Heat treatment: Natural cooling or quenching Quenching or in-situ study

Thermal Analysis: Dynamic Methods Measurement of physical property of a substance as a function of temperature using controlled temperature program MethodMeasured propertyApplication Differential Thermal Analysis (DTA) Temperature difference Phase reactions, phase transformations Differential Scanning Calorimetry (DSC) Heat flowSpecific heat, Heat of transition Thermal Gravimetric Analysis (TGA) Mass ChangeReactions with the gas phase, decomposition reactions DilatometrySize ChangePhase transformations, Thermal expansion Thermomechanical Analysis (TMA) Mechanical properties Materials testing

DTA/Heat-Flux DSC The temperature is not measured in the sample, but at the bottom of crucible. Temperature calibration is necessary. DTA/HF-DSC signal is difference between sample and reference thermocouples. It is usually given in mV. For some devices it is given as temperature difference; this means that reference table or equation was used by instrument to calculate temperature from voltage difference.

The DTA Signal T W is furnace temperature, T C is temperature of crucible T T is temperature of thermocouple, T S is sample temperature Idealized curve Real curve Heat is transferred between furnace, crucible, sample (reference) and thermocouple

DTA signal  r =L(T m -T S ) L is apparent thermal conductance to the sample, T m is measured temperature, T S is sample temperature  is heating rate

DTA responses to melting and freezing of pure substance: a- onset temperature, b- peak at temperature c. Due to dynamic character of experiment, the temperature distribution is never completely homogeneous. The temperature is not measured in the sample, but at the bottom of crucible. That is why temperature correction is necessary. DTA signal for unary system

Temperature calibration Temperature calibration: establishment of relation between measured temperature T meas indicated by the instrument and the true temperature T tr. At least three substances (usually pure metals) with melting temperature covering temperature range of interest should be selected. Mass should be corresponded to recommended mass for measurement in this instrument. Measurement should be done with different heating range  and extrapolated to  =0. Measured temperature vs. time and associated DTA plot for melting of pure Sn. Black is measurement with instrument thermocouple, red is results from a thermocouple immersed directly in the Sn sample.

Temperature calibration SubstanceT, °C Sn Al Ag Au Pd Extrapolated T melting of Sn to  =0 for different sample mass Temperature correction for Ga, In and Sn Measured temperature of thermal event depends on mass and cooling rate .

 T=T s -T ref is difference between sample temperature and reference Red line –  T vs. time Solid black line -  T vs. T s Dashed line –  T vs. T ref T ref =T 0 +  T DTA melting of pure Ag at 10 K/min Reference thermocouple T tc ref and sample thermocouple T tc sample vs. time Plotting DTA signal vs. Temperature or time  T vs. time is necessary for quantitative determination of enthalpy.  T vs T sample is better for determination of temperature of thermal event.

Enthalpy calibration K H is instrument sensitivity for Ga, In, Sn

Recommended values of temperatures and enthalpies of melting of metals ElementTmelt (°C)  Hm(J/g) Ga In Sn Zn Al Ag Au Enthalpy calibration factors for each calibration substance are represented as a function of transition temperature. Provided the dependence on heating rate  and sample mass are negligible (within scatter of individual experiments) the enthalpy calibration factor K H (T tr, m,  ) give the enthalpy calibration function K H (T).

Problems Influence of mass and heating rate: Larger mass and larger heating rate produce larger peak, but make detection of closely spaced thermal events more difficult. Blue 5 K/min, red-10 K/min, black – 15 K/min

Problems Sample shape is typically not conform to the shape of the sample cup. The thermal contact area between the sample and crucible will change during melting process. Possible solution is second heating. However in case of complicated phase diagram and not equilibrium freezing different phase assemblage can be present in the sample before second heating.

Undercooling problem with liquidus determination on cooling Many metals and alloys are prone to undercooling before the nucleation of solid phase start from melt. Nucleation temperature can differ from liquidus up to 100 or more degree depending on nature of alloy system and other factors. Determination of melting on heating is more reliable. Measured temperature vs. Time (a) and DTA signal vs. Temperature for freezing of pure Sn. The instrument thermocouple readings are black and from thermocouple immersed directly into Sn sample are red. For the immersed thermocouple the temperature reheats up to melting temperature as heat of fusion is released rapidly.

Powder sample increase oxidation, reduce heat flaw Solutions: Inert powder cover – to increase the thermal conduction to the sample cup Lid – to reduce material loss and contamination of the instrument, to prevent sample radiation loss and maintain an isothermal sample Atmosphere. Commercial purity inert gas is no adequate. Use of high purity inert gas to a Ti getter is recommended. Helium (He) has higher thermal conductivity than Ar; the choice can alter thermal transport rates in DTA instrument. Calibration should be performed with the same gas as used for samples Crucible selection/reaction. High purity Al 2 O 3 is standard DTA crucibles for metals investigation. Use of ZrO 2 and Y 2 O 3 crucibles can be recommended for highly reactive metals. Carbon crucibles can be recommended for metals not forming carbides. Pt, W crucibles can be used for ceramic materials Problems

Good praxis for DTA experiments Calibration: Based on the melting point of pure substances. Crucible, standard material, heating rate, sample mass, atmosphere are kept constant Characterisation: The composition of samples and crystal structure have to be investigated before and after the measurement Combination: DTA experiments tell us that something is happening at a specific temperature. They usually do not tell us, what is happening. Combination with other methods like X-ray diffraction, spectroscopy, microscopic investigation and composition analysis (e.g. Electron probe microanalysis) are required to interpret the results

DTA vs. DSC DTA DSC Heat-fluxPower compensation  T between sample and reference More robust, measurements can be done in wider T range, in more aggressive environment (oxidation atmosphere), possible combination with TGA to measure mass change HF-DSC is more sensitive than DTA, possible to measure heat capacity T and  H of transformation T and  H of transformation, Cp measurements Power compensation to keep the same temperature in both furnaces T and  H of transformation, Cp measurements More effective, since response time is shorter than in HF-DSC TT