Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 25 Digital Imaging.

Slides:



Advertisements
Similar presentations
DIGITAL RADIOGRAPHY.
Advertisements

IMAGE FORMATION  Introduction  The Invisible and Visible Image  Image Characteristics.
Digital Imaging in Dentistry Applications and Challenges
RADIOLOGY. NEXT GENERATION SCIENCE / COMMON CORE STANDARDS ADDRESSED! CCSS.ELA-Literacy.RST Determine the central ideas or conclusions of a text;
Chapter 19 Bite-Wing Technique.
1 DIGITAL RADIOGRAPHY. 2 Digital Radiography A “filmless” imaging system introduced in 1987 Digital radiography uses an electronic sensor, instead of.
Imaging Systems X-Rays. Imaging Systems: Shared Elements 1.Where did the energy come from? 2.What happens when the energy interacts with matter? 3.How.
14 The Periapical Examination-Paralleling Technique.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 8 Dental X-Ray Image Characteristics.
Chapter 42 Extraoral and Digital Radiography
Basic Concepts of Other Imaging Modalities
Chapter 6 Cassetteless Equipment and Image Acquisition
14.2 Data Capture Digital Imaging using CCDs. Capacitors  A capacitor is a device that stores charge.  Def’n of Capacitance - The ratio of the charge.
Digital Radiography Chapter 22. History of Digital Radiography Slower process of conversion because no pressing need to convert to digital radiography.
Direct Digital Radiography or Direct Capture Radiography Bushong Ch. 27.
TERPSSC 2001Robert M. Gagne OVERVIEW OF DIGITAL IMAGING AND RADIATION PROTECTION ISSUES Robert M. Gagne MICAB/DECS/OST [From: Handbook.
 No film or processing chemistry is used.  Digital radiograph instead uses an electronic sensor and computerized image system that produce x-ray images.
Introduction To Digital Radiography And PACS
Digital Image Characteristic
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 24 Imaging of Patients with Special Needs.
Chapter 7 Dental X-Ray Film.
Digital Radiography.  Invention of digital imaging  Fundamentals of digital imaging & equipment  Radiation exposure  Advantages/disadvantages  Infection.
Define capacitance Describe the structure of a charge-coupled device (CCD) Explain how incident light causes charge to build up.
Write: “IB Physics 4 Life!” in binary. 8. Digital Technology Chapter 8.2 – Digital imaging with charge- coupled devices.
Computers in Imaging Q & A Robert Metzger, Ph.D..
DIGITAL RADIOGRAPHY DA 105.
© 1999 Rochester Institute of Technology Introduction to Digital Imaging.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 6 Dental X-Ray Equipment.
Elements of DR Imaging Systems
1 INTRODUCTION TO THE PHYSICS OF DIAGNOSTIC IMAGING Outline of Course Brief History Common Terminology Imaging Modalities.
23 Dental Radiography. 2 Extraoral Radiographs Panoramic –Common in general and specialty offices Cephalometric –Common with orthodontists Digital –Becoming.
Chapter 9. Copyright ©2012 by Pearson Education, Inc. All rights reserved. Essentials of Dental Radiography for Dental Assistants and Hygienists, Ninth.
Radiology started with simple traditional x-ray technology.
Chapter 10 Infection Control. Copyright ©2012 by Pearson Education, Inc. All rights reserved. Essentials of Dental Radiography for Dental Assistants and.
Sounds of Old Technology IB Assessment Statements Topic 14.2., Data Capture and Digital Imaging Using Charge-Coupled Devices (CCDs) Define capacitance.
©2013 Delmar, Cengage Learning. All Rights Reserved. May not be scanned, copied, duplicated, or posted to a publicly accessible website, in whole or in.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 23 Extraoral Imaging.
Digital Camera TAVITA SU’A. Overview ◦Digital Camera ◦Image Sensor ◦CMOS ◦CCD ◦Color ◦Aperture ◦Shutter Speed ◦ISO.
The Future of Photography. What is traditional photography? Lens Light tight box Light sensitive material Eos 1v Camera (no lens) ($1500) Canon EF mm.
Quality Assurance in the Dental Office
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 30 Introduction to Image Interpretation.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 18 Bisecting Technique.
Charge-Coupled Devices Astrophysics Lesson 5. Learning Objectives Describe and explain the structure and operation of the charge coupled device State.
DIGITAL CAMERAS THE IMAGE SENSORS. CCD: Charged Coupled Device CMOS: Complementary Metal Oxide Semiconductor The differences between these two sensors.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 14 Legal Issues and the Dental Radiographer.
Fundamentals of Digital Images & Photography. Pixels & Colors The pixel (a word invented from "picture element") is the basic unit of programmable color.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 28 Film Mounting and Viewing.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 21 Occlusal and Localization Techniques.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 20 Exposure and Technique Errors.
By Prof. Stelmark. Digital Imaging In digital imaging, the latent image is stored as digital data and must be processed by the computer for viewing on.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 1 Chapter 11 Dental Radiographs and the Dental Radiographer.
DIGITAL RADIOGRAPHY.
Direct Digital Radiography or Direct Capture Radiography
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 1 Extraoral Imaging.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 26 Three-Dimensional Digital Imaging.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 1 Digital Imaging Instead of Radiography.
Digital Cameras A digital camera ( or digital) is a camera that takes video or still photographs, or both, digitally by recording images by an electronic.
Digital Radiography Chapter 26. Digital radiographs Different from analog images (traditional radiographs). Filmless imaging using pixels. Instant images.
DIGITAL RADIOGRAPHY Dr. Rupak Sethuraman.
History of digital radiology 1980 Kinos L.T. ET all developed a portable radiographic X-ray camera made of tantalum and aluminum. Digital radiography.
P3 Physics Medical applications Section X – rays N-T 208: Longmans: 176 a) X-rays are part of the e …………………… s………..... They have a very _________.
Principles of Dental Imaging
Digital Image -M.V.Ramachandranwww.youtube.com/postmanchandru
NETWORK VIDEO SURVEILLANCE. CCTV Closed-Circuit Television (CCTV) is the use of video cameras to transmit signal to a specific place on a designated device.
Digital Radiography In Dentistry
Imaging Characteristics
כיצד נרכשת התמונה בסרט הרנטגני?
Computed Radiography Feb.
Radiology Basics Dental Assistant Registration Course
Digital radiography.
Presentation transcript:

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 25 Digital Imaging

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 2 Dental Radiography  Questions  What equipment is used in digital imaging?  What types of digital imaging are available?  What are advantages and disadvantages of digital imaging?

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 3 Dental Radiography  Chapter 25 Reading  Iannucci & Howerton (pp )

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 4 Dental Radiography  Chapter 25 Outline  Digital Imaging  Basic concepts  Types of digital imaging  Step-by-step procedures  Advantages and disadvantages

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 5 Introduction  Iannucci & Howerton (p. 301)  Purpose  To present the basic concepts of digital imaging  To introduce the types of digital imaging  To discuss the advantages and disadvantages of digital imaging

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 6 Basic Concepts  Iannucci & Howerton (p. 302)  Used to record radiographic images  No film or processing chemistry is used  Uses an electronic sensor and computerized imaging system that produces x-ray images almost instantly on a computer monitor

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 7 Terminology  Iannucci & Howerton (p. 302)  Charge-coupled device  Digital radiography  Digital subtraction  Digitize

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 8 Terminology  Direct digital imaging  Indirect digital imaging  Pixel  Sensor  Storage phosphor imaging

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 9 Purpose and Use  Iannucci & Howerton (p. 302)  To generate images that can be used in the diagnosis and assessment of dental disease

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 10 Purpose and Use  To detect lesions, diseases and conditions of the teeth and surrounding structures  To confirm or classify suspected disease  To provide information during dental procedures  To evaluate growth and development  To illustrate changes secondary to caries, periodontal disease, or trauma  To document the condition of a patient at a specific point in time

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 11 Fundamentals  Iannucci & Howerton (pp ) (Figs. 25-1, 25-2)  Digital imaging  A method of capturing a radiographic image using a sensor, breaking it into electronic pieces, and presenting and storing the image using a computer  Image used to describe the pictures that are produced  A sensor placed inside the mouth  The electronic signal is digitized

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 12 Radiation Exposure  Iannucci & Howerton (p. 303)  The typical sensor is more sensitive to x-rays than conventional film.  Exposure times are 50% to 80% less than that required for conventional radiography using E- speed film.

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 13 Equipment  Iannucci & Howerton (p. 303)  X-radiation source  Intraoral sensor  Charge-coupled device  Complementary metal oxide semiconductor/active pixel sensor  Charge injection device  Computer

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 14 X-Radiation Source  Iannucci & Howerton (pp ) (Fig. 25-3)  Most digital imaging systems use a conventional dental x-ray unit as the x- radiation source.  The x-ray unit timer must be adapted to allow exposures in a time frame of 1/100 of a second.

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 15 Intraoral Sensor  Iannucci & Howerton (p.304) (Figs. 25-4, 25-5)  A small detector that is placed in the mouth of the patient and used to capture the radiographic image  Wired The imaging sensor is linked by a fiber optic cable to a computer. The imaging sensor is linked by a fiber optic cable to a computer.  Wireless The imaging sensor is not linked by a cable. The imaging sensor is not linked by a cable.

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 16 Intraoral Sensor  Most popular types of direct sensor technologies  Charge-coupled device  Complementary metal oxide semiconductor/active pixel sensor

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 17 Charge-Coupled Device (CCD)  Iannucci & Howerton (p. 304)  The most common image receptor used in dental digital imaging  A solid-state detector that contains a silicon chip with an electronic circuit embedded in it  The electrons that make up the silicon CCD can be visualized as being divided into an arrangement of blocks or picture elements known as pixels  Pixel  A small box or “well” into which the electrons produced by the x-ray exposure are deposited

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 18 Charge-Coupled Device (CCD)  The x-ray photons that come into contact with the CCD cause electrons to be released from the silicon and produce a corresponding electronic charge.  Each pixel arrangement, or electron potential well, contains an electronic charge proportional to the number of electrons that reacted within the well.  Each electronic well corresponds to a specific area on the linked computer screen.

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 19 Complementary Metal Oxide Semiconductor/Active Pixel Sensor (CMOS/APS)  Iannucci & Howerton (pp )  One manufacturer uses a CMOS/APS sensor instead of a CCD.  The chip is less expensive to produce and offers greater durability than the CCD.

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 20 Computer  Iannucci & Howerton (p. 305) (Figs. 25-6, 25-7, 25-8)  Used to store the incoming electronic signal  Converts the electronic signal from the sensor into a shade of gray that is viewed on the computer monitor  The computer digitizes, processes, and stores information received from the sensor  An image is recorded on a computer monitor in 0.5 to 120 seconds  Has split screen and magnification capability.

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 21 Types of Digital Imaging  Direct Digital Imaging  Indirect Digital Imaging  Scanning traditional radiographs  Storage phosphor imaging

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 22 Direct Digital Imaging  Iannucci & Howerton (p. 306) (Fig. 25-9)  Components include an x-ray machine, an intraoral sensor, and computer monitor  A sensor is placed into the mouth of the patient and exposed  The sensor captures the radiographic image and transmits it to the computer monitor  Software is used to enhance and store the image

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 23 Indirect Digital Imaging  Iannucci & Howerton (p. 306)  Components include a CCD camera and a computer.  An existing x-ray film is digitized using a CCD camera.  The image is displayed on a computer monitor.

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 24 Storage Phosphor Imaging  Iannucci & Howerton (pp ) (Figs , 25-11)  A wireless digital imaging system  This is a reusable imaging plate coated with phosphors is used instead of a sensor with a fiber optic cable.  The phosphor-coated plates are flexible and fit into the mouth.  A high-speed scanner is used to convert the information into electronic files.  This type of digital imaging is less rapid than direct digital imaging.

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 25 Step-by-Step Procedures  Sensor Preparation  Sensor Placement

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 26 Step-by-Step Procedures  It is critical to refer to the manufacturer- provided instruction booklet for information concerning the operation of the system, equipment preparation, patient preparation, and exposure.

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 27 Sensor Preparation  Iannucci & Howerton (p. 307) (Figs , 25-13)  Each sensor is sealed and waterproofed.  The sensor must be covered with a disposable barrier because it cannot be sterilized.

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 28 Sensor Placement  Iannucci & Howerton (pp ) (Fig )  The sensor is held in the mouth by bite-block attachments or devices that aim the beam and sensor accurately.  The paralleling technique is the preferred exposure method.

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 29 Advantages and Disadvantages  Advantages of Digital Imaging  Disadvantages of Digital Imaging

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 30 Advantages of Digital Imaging  Iannucci & Howerton (pp ) (Figs , 25-16, 25-17, 25-18)  Superior gray-scale resolution  Reduced exposure to x-radiation  Increased speed of image viewing  Lower equipment and film cost  Increased efficiency  Enhancement of diagnostic image  Effective patient education tool

Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 31 Disadvantages of Digital Imaging  Iannucci & Howerton (pp )  Initial set-up costs  Image quality  Sensor size  Infection control  Legal issues